-
1
-
-
12244299864
-
Upscaling and automation of electrophysiology: Toward high throughput screening in ion channel drug discovery
-
Asmild M, Oswald N, Krzywkowski KM, Friis S, Jacobsen RB, Reuter D, Taboryski R, Kutchinsky J, Vestergaard RK, Schroder RL, Sorensen CB, Bech M, Korsgaard MP, Willumsen NJ (2003) Upscaling and automation of electrophysiology: toward high throughput screening in ion channel drug discovery. Recept Channels 9:49-58
-
(2003)
Recept Channels
, vol.9
, pp. 49-58
-
-
Asmild, M.1
Oswald, N.2
Krzywkowski, K.M.3
Friis, S.4
Jacobsen, R.B.5
Reuter, D.6
Taboryski, R.7
Kutchinsky, J.8
Vestergaard, R.K.9
Schroder, R.L.10
Sorensen, C.B.11
Bech, M.12
Korsgaard, M.P.13
Willumsen, N.J.14
-
2
-
-
1942465537
-
High quality ion channel analysis on a chip with the NPC technology
-
Bruggemann A, George M, Klau M, Beckler M, Steindl J, Behrends JC, Fertig N (2003) High quality ion channel analysis on a chip with the NPC technology. Assay Drug Dev Technol 1:665-673
-
(2003)
Assay Drug Dev Technol
, vol.1
, pp. 665-673
-
-
Bruggemann, A.1
George, M.2
Klau, M.3
Beckler, M.4
Steindl, J.5
Behrends, J.C.6
Fertig, N.7
-
3
-
-
0037858858
-
High-throughput screening for ion channel modulators
-
Falconer M, Smith F, Surah-Narwal S, Congrave G, Liu Z, Hayter P, Ciaramella G, Keighley W, Haddock P, Waldron G, Sewing A (2002) High-throughput screening for ion channel modulators. J Biomol Screen 7:460-465
-
(2002)
J Biomol Screen
, vol.7
, pp. 460-465
-
-
Falconer, M.1
Smith, F.2
Surah-Narwal, S.3
Congrave, G.4
Liu, Z.5
Hayter, P.6
Ciaramella, G.7
Keighley, W.8
Haddock, P.9
Waldron, G.10
Sewing, A.11
-
4
-
-
0036106307
-
Whole cell patch clamp recording performed on a planar glass chip
-
Fertig N, Blick RH, Behrends JC (2002) Whole cell patch clamp recording performed on a planar glass chip. Biophys J 82:3056-3062
-
(2002)
Biophys J
, vol.82
, pp. 3056-3062
-
-
Fertig, N.1
Blick, R.H.2
Behrends, J.C.3
-
5
-
-
2542484682
-
Flux assays in high throughput screening of ion channels in drug discovery
-
Gill S, Gill R, Lee SS, Hesketh JC, Fedida D, Rezazadeh S, Stankovich L, Liang D (2003) Flux assays in high throughput screening of ion channels in drug discovery. Assay Drug Dev Technol 1:709-717
-
(2003)
Assay Drug Dev Technol
, vol.1
, pp. 709-717
-
-
Gill, S.1
Gill, R.2
Lee, S.S.3
Hesketh, J.C.4
Fedida, D.5
Rezazadeh, S.6
Stankovich, L.7
Liang, D.8
-
6
-
-
0019441262
-
Improved patch-clamp techniques for high-resolution current recording from cells and cell-free membrane patches
-
Hamill OP, Marty A, Neher E, Sakmann B, Sigworth FJ (1981) Improved patch-clamp techniques for high-resolution current recording from cells and cell-free membrane patches. Pflugers Arch 391:85-100
-
(1981)
Pflugers Arch
, vol.391
, pp. 85-100
-
-
Hamill, O.P.1
Marty, A.2
Neher, E.3
Sakmann, B.4
Sigworth, F.J.5
-
7
-
-
0042895988
-
High throughput ion-channel pharmacology: Planar-array-based voltage clamp
-
Kiss L, Bennett PB, Uebele VN, Koblan KS, Kane SA, Neagle B, Schroeder K (2003) High throughput ion-channel pharmacology: planar-array-based voltage clamp. Assay Drug Dev Technol 1:127-135
-
(2003)
Assay Drug Dev Technol
, vol.1
, pp. 127-135
-
-
Kiss, L.1
Bennett, P.B.2
Uebele, V.N.3
Koblan, K.S.4
Kane, S.A.5
Neagle, B.6
Schroeder, K.7
-
8
-
-
0037178198
-
Micromolded PDMS planar electrode allows patch clamp electrical recordings from cells
-
Klemic KG, Klemic JF, Reed MA, Sigworth FJ (2002) Micromolded PDMS planar electrode allows patch clamp electrical recordings from cells. Biosens Bioelectron 17:597-604
-
(2002)
Biosens Bioelectron
, vol.17
, pp. 597-604
-
-
Klemic, K.G.1
Klemic, J.F.2
Reed, M.A.3
Sigworth, F.J.4
-
9
-
-
0016818038
-
Effect of internal fluoride and phosphate on membrane currents during intracellular dialysis of nerve cells
-
Kostyuk PG, Krishtal OA, Pidoplichko VI (1975) Effect of internal fluoride and phosphate on membrane currents during intracellular dialysis of nerve cells. Nature 257:691-693
-
(1975)
Nature
, vol.257
, pp. 691-693
-
-
Kostyuk, P.G.1
Krishtal, O.A.2
Pidoplichko, V.I.3
-
10
-
-
0037234427
-
Flip the tip: An automated, high quality, cost-effective patch clamp screen
-
Lepple-Wienhues A, Ferlinz K, Seeger A, Schafer A (2003) Flip the tip: an automated, high quality, cost-effective patch clamp screen. Recept Channels 9:13-17
-
(2003)
Recept Channels
, vol.9
, pp. 13-17
-
-
Lepple-Wienhues, A.1
Ferlinz, K.2
Seeger, A.3
Schafer, A.4
-
11
-
-
0346881208
-
Ion channels in drug discovery and development
-
Mathes C (2003) Ion channels in drug discovery and development. Drug Discov Today 8:1022-1024
-
(2003)
Drug Discov Today
, vol.8
, pp. 1022-1024
-
-
Mathes, C.1
-
13
-
-
0141819130
-
Microfabricated teflon membranes for low-noise recordings of ion channels in planar lipid bilayers
-
Mayer M, Kriebel JK, Tosteson MT, Whitesides GM (2003) Microfabricated teflon membranes for low-noise recordings of ion channels in planar lipid bilayers. Biophys J 85:2684-2695
-
(2003)
Biophys J
, vol.85
, pp. 2684-2695
-
-
Mayer, M.1
Kriebel, J.K.2
Tosteson, M.T.3
Whitesides, G.M.4
-
14
-
-
3242770620
-
High throughput screening method of potassium channel regulators
-
Pan YP, Xu XH, Wang XL (2004) High throughput screening method of potassium channel regulators. Yao Xue Xue Bao 39:85-88
-
(2004)
Yao Xue Xue Bao
, vol.39
, pp. 85-88
-
-
Pan, Y.P.1
Xu, X.H.2
Wang, X.L.3
-
15
-
-
0034805579
-
Bilayer reconstitution of voltage-dependent ion channels using a microfabricated silicon chip
-
Pantoja R, Sigg D, Blunck R, Bezanilla F, Heath JR (2001) Bilayer reconstitution of voltage-dependent ion channels using a microfabricated silicon chip. Biophys J 81:2389-2394
-
(2001)
Biophys J
, vol.81
, pp. 2389-2394
-
-
Pantoja, R.1
Sigg, D.2
Blunck, R.3
Bezanilla, F.4
Heath, J.R.5
-
16
-
-
1842675219
-
+ channels: Ion flux studies by atomic absorption spectrometry
-
+ channels: ion flux studies by atomic absorption spectrometry. Assay Drug Dev Technol 1:647-654
-
(2003)
Assay Drug Dev Technol
, vol.1
, pp. 647-654
-
-
Parihar, A.S.1
Groebe, D.R.2
Scott, V.E.3
Feng, J.4
Zhang, X.F.5
Warrior, U.6
Gopalakrishnan, M.7
Shieh, C.C.8
-
17
-
-
0344492207
-
Relationships between preclinical cardiac electrophysiology, clinical QT interval prolongation and torsade de pointes for a broad range of drugs: Evidence for a provisional safety margin in drug development
-
Redfern WS, Carlsson L, Davis AS, Lynch WG, MacKenzie I, Palethorpe S, Siegl PK, Strang I, Sullivan AT, Wallis R, Camm AJ, Hammond TG (2003) Relationships between preclinical cardiac electrophysiology, clinical QT interval prolongation and torsade de pointes for a broad range of drugs: evidence for a provisional safety margin in drug development. Cardiovasc Res 58:32-45
-
(2003)
Cardiovasc Res
, vol.58
, pp. 32-45
-
-
Redfern, W.S.1
Carlsson, L.2
Davis, A.S.3
Lynch, W.G.4
MacKenzie, I.5
Palethorpe, S.6
Siegl, P.K.7
Strang, I.8
Sullivan, A.T.9
Wallis, R.10
Camm, A.J.11
Hammond, T.G.12
-
18
-
-
0041888478
-
Ionworks HT: A new high-throughput electrophysiology measurement platform
-
Schroeder K, Neagle B, Trezise DJ, Worley J (2003) Ionworks HT: a new high-throughput electrophysiology measurement platform. J Biomol Screen 8:50-64
-
(2003)
J Biomol Screen
, vol.8
, pp. 50-64
-
-
Schroeder, K.1
Neagle, B.2
Trezise, D.J.3
Worley, J.4
-
19
-
-
2942567934
-
Automated high-throughput patch-clamp techniques
-
Shieh CC (2004) Automated high-throughput patch-clamp techniques. Drug Discov Today 9:551-552
-
(2004)
Drug Discov Today
, vol.9
, pp. 551-552
-
-
Shieh, C.C.1
-
20
-
-
0037232042
-
CYTOCENTERING: A novel technique enabling automated cell-by-cell patch clamping with the CYTOPATCH chip
-
Stett A, Burkhardt C, Weber U, van Stiphout P, Knott T (2003) CYTOCENTERING: a novel technique enabling automated cell-by-cell patch clamping with the CYTOPATCH chip. Recept Channels 9:59-66
-
(2003)
Recept Channels
, vol.9
, pp. 59-66
-
-
Stett, A.1
Burkhardt, C.2
Weber, U.3
Van Stiphout, P.4
Knott, T.5
-
21
-
-
0035122587
-
Recombinant maxi-K channels on transistor, a prototype of iono-electronic interfacing
-
Straub B, Meyer E, Fromherz P (2001) Recombinant maxi-K channels on transistor, a prototype of iono-electronic interfacing. Nat Biotechnol 19:121-124
-
(2001)
Nat Biotechnol
, vol.19
, pp. 121-124
-
-
Straub, B.1
Meyer, E.2
Fromherz, P.3
-
22
-
-
10244245061
-
Automated tight seal electrophysiology for assessing the potential hERG liability of pharmaceutical compounds
-
Tao H, Santa Ana D, Guia A, Huang M, Ligutti J, Walker G, Sithiphong K, Chan F, Guoliang T, Zozulya Z, Saya S, Phimmachack R, Sie C, Yuan J, Wu L, Xu J, Ghetti A (2004) Automated tight seal electrophysiology for assessing the potential hERG liability of pharmaceutical compounds. Assay Drug Dev Technol 2:497-506
-
(2004)
Assay Drug Dev Technol
, vol.2
, pp. 497-506
-
-
Tao, H.1
Santa Ana, D.2
Guia, A.3
Huang, M.4
Ligutti, J.5
Walker, G.6
Sithiphong, K.7
Chan, F.8
Guoliang, T.9
Zozulya, Z.10
Saya, S.11
Phimmachack, R.12
Sie, C.13
Yuan, J.14
Wu, L.15
Xu, J.16
Ghetti, A.17
-
23
-
-
0033179793
-
Functional analysis of native and recombinant ion channels using a high-capacity nonradioactive rubidium efflux assay
-
Terstappen GC (1999) Functional analysis of native and recombinant ion channels using a high-capacity nonradioactive rubidium efflux assay. Anal Biochem 272:149-155
-
(1999)
Anal Biochem
, vol.272
, pp. 149-155
-
-
Terstappen, G.C.1
-
24
-
-
10244237790
-
Nonradioactive rubidium ion efflux assay and its applications in drug discovery and development
-
Terstappen GC (2004) Nonradioactive rubidium ion efflux assay and its applications in drug discovery and development. Assay Drug Dev Technol 2:553-559
-
(2004)
Assay Drug Dev Technol
, vol.2
, pp. 553-559
-
-
Terstappen, G.C.1
-
25
-
-
29144470622
-
Development of a novel automated ion channel recording method using "inside-out" whole-cell membranes
-
Vasilyev DV, Merrill TL, Bowlby MR (2005) Development of a novel automated ion channel recording method using "inside-out" whole-cell membranes. J Biomol Screen 10:806-813
-
(2005)
J Biomol Screen
, vol.10
, pp. 806-813
-
-
Vasilyev, D.V.1
Merrill, T.L.2
Bowlby, M.R.3
-
26
-
-
19344375316
-
Differential inhibition of rat alpha3* and alpha7 nicotinic acetylcholine receptors by tetrandrine and closely related bis- benzylisoquinoline derivatives
-
Virginio C, Graziani F, Terstappen GC (2005) Differential inhibition of rat alpha3* and alpha7 nicotinic acetylcholine receptors by tetrandrine and closely related bis-benzylisoquinoline derivatives. Neurosci Lett 381:299-304
-
(2005)
Neurosci Lett
, vol.381
, pp. 299-304
-
-
Virginio, C.1
Graziani, F.2
Terstappen, G.C.3
-
27
-
-
0032904759
-
Inhibition of HERG channels stably expressed in a mammalian cell line by the antianginal agent perhexiline maleate
-
Walker BD, Valenzuela SM, Singleton CB, Tie H, Bursill JA, Wyse KR, Qiu MR, Breit SN, Campbell TJ (1999) Inhibition of HERG channels stably expressed in a mammalian cell line by the antianginal agent perhexiline maleate. Br J Pharmacol 127:243-251
-
(1999)
Br J Pharmacol
, vol.127
, pp. 243-251
-
-
Walker, B.D.1
Valenzuela, S.M.2
Singleton, C.B.3
Tie, H.4
Bursill, J.A.5
Wyse, K.R.6
Qiu, M.R.7
Breit, S.N.8
Campbell, T.J.9
-
28
-
-
1942529811
-
Automated electrophysiology: High throughput of art
-
Wang X, Li M (2003) Automated electrophysiology: high throughput of art. Assay Drug Dev Technol 1:695-708
-
(2003)
Assay Drug Dev Technol
, vol.1
, pp. 695-708
-
-
Wang, X.1
Li, M.2
-
29
-
-
0034753261
-
Validation of FLIPR membrane potential dye for high throughput screening of potassium channel modulators
-
Whiteaker KL, Gopalakrishnan SM, Groebe D, Shieh CC, Warrior U, Burns DJ, Coghlan MJ, Scott VE, Gopalakrishnan M (2001) Validation of FLIPR membrane potential dye for high throughput screening of potassium channel modulators. J Biomol Screen 6:305-312
-
(2001)
J Biomol Screen
, vol.6
, pp. 305-312
-
-
Whiteaker, K.L.1
Gopalakrishnan, S.M.2
Groebe, D.3
Shieh, C.C.4
Warrior, U.5
Burns, D.J.6
Coghlan, M.J.7
Scott, V.E.8
Gopalakrishnan, M.9
-
31
-
-
0035892592
-
Ion-channel assay technologies: Quo vadis?
-
Xu J, Wang X, Ensign B, Li M, Wu L, Guia A (2001) Ion-channel assay technologies: quo vadis? Drug Discov Today 6:1278-1287
-
(2001)
Drug Discov Today
, vol.6
, pp. 1278-1287
-
-
Xu, J.1
Wang, X.2
Ensign, B.3
Li, M.4
Wu, L.5
Guia, A.6
-
32
-
-
1942433697
-
A benchmark study with sealchip planar patch-clamp technology
-
Xu J, Guia A, Rothwarf D, Huang M, Sithiphong K, Ouang J, Tao G, Wang X, Wu L (2003) A benchmark study with sealchip planar patch-clamp technology. Assay Drug Dev Technol 1:675-684
-
(2003)
Assay Drug Dev Technol
, vol.1
, pp. 675-684
-
-
Xu, J.1
Guia, A.2
Rothwarf, D.3
Huang, M.4
Sithiphong, K.5
Ouang, J.6
Tao, G.7
Wang, X.8
Wu, L.9
-
33
-
-
0037799798
-
Functional properties of homomeric, human alpha 7-nicotinic acetylcholine receptors heterologously expressed in the SH-EP1 human epithelial cell line
-
Zhao L, Kuo YP, George AA, Peng JH, Purandare MS, Schroeder KM, Lukas RJ, Wu J (2003) Functional properties of homomeric, human alpha 7-nicotinic acetylcholine receptors heterologously expressed in the SH-EP1 human epithelial cell line. J Pharmacol Exp Ther 305:1132-1141
-
(2003)
J Pharmacol Exp Ther
, vol.305
, pp. 1132-1141
-
-
Zhao, L.1
Kuo, Y.P.2
George, A.A.3
Peng, J.H.4
Purandare, M.S.5
Schroeder, K.M.6
Lukas, R.J.7
Wu, J.8
-
34
-
-
10244264821
-
High throughput assay technologies for ion channel drug discovery
-
Zheng W, Spencer RH, Kiss L (2004) High throughput assay technologies for ion channel drug discovery. Assay Drug Dev Technol 2:543-552
-
(2004)
Assay Drug Dev Technol
, vol.2
, pp. 543-552
-
-
Zheng, W.1
Spencer, R.H.2
Kiss, L.3
|