-
1
-
-
0034044540
-
Reconstruction principles of icosahedral virus structure determination using electron microscopy
-
P.A. Thuman-Commike and W. Chiu, "Reconstruction principles of icosahedral virus structure determination using Electron Microscopy", Micron 31: 687-711, (2000).
-
(2000)
Micron
, vol.31
, pp. 687-711
-
-
Thuman-Commike, P.A.1
Chiu, W.2
-
2
-
-
1842409555
-
Determination of the fold of the core protein of hepatitis B virus by electron cryomicroscopy
-
B. Bottcher, S.A. Wynne & R.A. Crowther, "Determination of the fold of the core protein of hepatitis B virus by electron cryomicroscopy," Nature 386: 88-94, (1997).
-
(1997)
Nature
, vol.386
, pp. 88-94
-
-
Bottcher, B.1
Wynne, S.A.2
Crowther, R.A.3
-
3
-
-
0034598935
-
Solution structure of the E. coli 70S ribosome at 11.5 A resolution
-
I.S. Gabashvili, R.K. Agrawal, C.M. Spahn, R.A. Grassucci, D.I. Svergun, J. Frank, P. Penczek, "Solution structure of the E. coli 70S ribosome at 11.5 A resolution," Cell 100: 537-549, (2000).
-
(2000)
Cell
, vol.100
, pp. 537-549
-
-
Gabashvili, I.S.1
Agrawal, R.K.2
Spahn, C.M.3
Grassucci, R.A.4
Svergun, D.I.5
Frank, J.6
Penczek, P.7
-
4
-
-
0034053676
-
Three-dimensional cryo-electron microscopy of ribosomes
-
J. Frank et al., "Three-dimensional cryo-electron microscopy of ribosomes," Method of Enz. 317: 276-291, (2000).
-
(2000)
Method of Enz.
, vol.317
, pp. 276-291
-
-
Frank, J.1
-
5
-
-
0033774875
-
Digital imaging in transmission electron microscopy
-
G.Y. Fan and M.H. Ellisman, "Digital imaging in transmission electron microscopy," Journal of Microscopy 200(1): 1-13, (2000).
-
(2000)
Journal of Microscopy
, vol.200
, Issue.1
, pp. 1-13
-
-
Fan, G.Y.1
Ellisman, M.H.2
-
6
-
-
0031168569
-
Cooled CCD camera with tapered fibre optics for electron microscopy
-
A.R. Faruqi and M.N. Andrews. "Cooled CCD Camera with Tapered Fibre Optics for Electron Microscopy," Nucl. Inst. and Meth. A 392: 233-236, (1997).
-
(1997)
Nucl. Inst. and Meth. A
, vol.392
, pp. 233-236
-
-
Faruqi, A.R.1
Andrews, M.N.2
-
7
-
-
0034128552
-
Multiport-readout frame-transfer 5 megapixel CCD imaging system for TEM applications
-
G.Y. Fan, S. Peltier, S. Lamont, D. Dunkelberger, B. Burke, M.H. Ellisman, "Multiport-readout frame-transfer 5 megapixel CCD imaging system for TEM applications," Ultramicroscopy 84: 75-84, (2000).
-
(2000)
Ultramicroscopy
, vol.84
, pp. 75-84
-
-
Fan, G.Y.1
Peltier, S.2
Lamont, S.3
Dunkelberger, D.4
Burke, B.5
Ellisman, M.H.6
-
8
-
-
17644432461
-
ASIC-based event-driven 2D digital electron counter for TEM imaging
-
G.Y. Fan, M.H. Ellisman, N-H Xuong, et al., "ASIC-based event-driven 2D digital electron counter for TEM imaging," Ultramicroscopy 70: 107-113, (1998).
-
(1998)
Ultramicroscopy
, vol.70
, pp. 107-113
-
-
Fan, G.Y.1
Ellisman, M.H.2
Xuong, N.-H.3
-
9
-
-
0037375595
-
Evaluation of a hybrid pixel detector for electron microscopy
-
A.R. Faruqi et al., "Evaluation of a Hybrid Pixel Detector for Electron Microscopy," Ultramicroscopy 94: 263-276, (2002).
-
(2002)
Ultramicroscopy
, vol.94
, pp. 263-276
-
-
Faruqi, A.R.1
-
10
-
-
0001806649
-
Near 100% fill factor CMOS active pixels
-
Brugge, Belgium, 5-7 June. Proceedings
-
B. Dierickx, G. Meynants, D. Scheffer. "Near 100% fill factor CMOS active pixels," IEEE CCD & AIS workshop, Brugge, Belgium, 5-7 June (1997). Proceedings p. P1;
-
(1997)
IEEE CCD & AIS Workshop
-
-
Dierickx, B.1
Meynants, G.2
Scheffer, D.3
-
11
-
-
0032403659
-
CMOS active pixel image sensor with CCD performance
-
Zurich, 18-21 May
-
See also, G. Meynants, B. Dierickx and D. Scheffer, "CMOS active pixel image sensor with CCD performance," APFAEC Europto/SPIE, Zurich, 18-21 May 1998;
-
(1998)
APFAEC Europto/SPIE
-
-
Meynants, G.1
Dierickx, B.2
Scheffer, D.3
-
12
-
-
11844292408
-
-
Proc. SPIE 3410: 68-76, (1998).
-
(1998)
Proc. SPIE
, vol.3410
, pp. 68-76
-
-
-
13
-
-
0035252425
-
A monolithic active pixel sensor for charge particle tracking and imaging using standard VLSI CMOS technology
-
R. Turchetta et al., "A monolithic active pixel sensor for charge particle tracking and imaging using standard VLSI CMOS technology," N.I.M. in Physics Res. A458, 677-689, 2001;
-
(2001)
N.I.M. in Physics Res.
, vol.A458
, pp. 677-689
-
-
Turchetta, R.1
-
14
-
-
0035365890
-
Particle tracking using CMOS monolithic active pixel sensor
-
See also, G. Claus et al., "Particle tracking using CMOS monolithic active pixel sensor," N.I.M. in Physics Res. A 465: 120-124, (2001).
-
(2001)
N.I.M. in Physics Res. A
, vol.465
, pp. 120-124
-
-
Claus, G.1
-
15
-
-
85028988120
-
Integrated X-ray and charged particle active pixel CMOS sensor arrays using an epitaxial silicon sensitive region
-
S. Kleinfelder, H. Wieman, E. Yamamoto et al., "Integrated X-ray and charged particle active pixel CMOS sensor arrays using an epitaxial silicon sensitive region," Proc. SPIE 4784: 208-217, (2002).
-
(2002)
Proc. SPIE
, vol.4784
, pp. 208-217
-
-
Kleinfelder, S.1
Wieman, H.2
Yamamoto, E.3
-
16
-
-
0042427409
-
Charged particle detection using a CMOS active pixel sensor
-
LBNL-51911, Dec 2002. 6pp. Presented at IEEE 2002 Nuclear Science Symposium (NSS) and Medical Imaging Conference (MIC) and Symposium on Nuclear Power Systems, Norfolk, Virginia, 10-16 Nov 2002. Published
-
H.S. Matis et al., "Charged Particle Detection Using a CMOS Active Pixel Sensor" LBNL-51911, Dec 2002. 6pp. Presented at IEEE 2002 Nuclear Science Symposium (NSS) and Medical Imaging Conference (MIC) and Symposium on Nuclear Power Systems, Norfolk, Virginia, 10-16 Nov 2002. Published in IEEE Trans. Nucl. Sci. 50:1020-1025, (2003).
-
(2003)
IEEE Trans. Nucl. Sci.
, vol.50
, pp. 1020-1025
-
-
Matis, H.S.1
-
17
-
-
8344269520
-
Novel integrated CMOS sensor circuits
-
S. Kleinfelder, F. Bieser, Y. D. Chen, R. Gareus, H. S. Matis, M. Oldenburg, F. Retiere, H. G. Ritter, H. H. Wieman, and E. Yamamoto, "Novel integrated CMOS sensor circuits," Ieee Transactions on Nuclear Science, vol. 51, pp. 2328-2336, 2004.
-
(2004)
Ieee Transactions on Nuclear Science
, vol.51
, pp. 2328-2336
-
-
Kleinfelder, S.1
Bieser, F.2
Chen, Y.D.3
Gareus, R.4
Matis, H.S.5
Oldenburg, M.6
Retiere, F.7
Ritter, H.G.8
Wieman, H.H.9
Yamamoto, E.10
-
18
-
-
0042427409
-
Charged particle detection using a CMOS active pixel sensor
-
H.S. Matis, F. Bieser, S. Kleinfelder, G. Rai, F. Retiere, H.G. Ritter, K. Singh, S.E. Wurzel, H. Weiman, E. Yamamoto, "Charged Particle Detection using a CMOS Active Pixel Sensor," IEEE Transactions on Nuclear Science, 50(4):1020-1025, (2003).
-
(2003)
IEEE Transactions on Nuclear Science
, vol.50
, Issue.4
, pp. 1020-1025
-
-
Matis, H.S.1
Bieser, F.2
Kleinfelder, S.3
Rai, G.4
Retiere, F.5
Ritter, H.G.6
Singh, K.7
Wurzel, S.E.8
Weiman, H.9
Yamamoto, E.10
-
19
-
-
33645654693
-
Novel pixel structures for vertex detectors
-
Conference Record of the 2003 IEEE
-
S. Kleinfelder, F. Bieser, Y. Chen, R. Gareus, H.S. Matis, M. Oldenburg, F. Retiere, H.G. Ritter, H.H. Wieman, E. Yamamoto, "Novel Pixel Structures for Vertex Detectors," Nuclear Science Symposium, 2003, Conference Record of the 2003 IEEE, (2003).
-
(2003)
Nuclear Science Symposium, 2003
-
-
Kleinfelder, S.1
Bieser, F.2
Chen, Y.3
Gareus, R.4
Matis, H.S.5
Oldenburg, M.6
Retiere, F.7
Ritter, H.G.8
Wieman, H.H.9
Yamamoto, E.10
-
20
-
-
0142241335
-
A CMOS active pixel sensor for charged particle detection
-
H.S. Matis, F. Bieser, S. Kleinfelder, G. Rai, F. Retiere, H.G. Ritter, K. Singh, S.E. Wurzell, H. Wieman, E. Yamamoto, "A CMOS Active Pixel Sensor for Charged Particle Detection," Nuclear Science Symposium, 2002. ConferenceRecord of the 2002 IEEE, 1: 259-263, (2002)
-
(2002)
Nuclear Science Symposium, 2002. ConferenceRecord of the 2002 IEEE
, vol.1
, pp. 259-263
-
-
Matis, H.S.1
Bieser, F.2
Kleinfelder, S.3
Rai, G.4
Retiere, F.5
Ritter, H.G.6
Singh, K.7
Wurzell, S.E.8
Wieman, H.9
Yamamoto, E.10
-
21
-
-
8844275950
-
First use of a high sensitivity active pixel sensor array as a detector for electron microscopy
-
N.H. Xuong et al., "First Use of a High Sensitivity Active Pixel Sensor Array as a Detector for Electron Microscopy," Proc. SPIE 5301: 243-249, (2004).
-
(2004)
Proc. SPIE
, vol.5301
, pp. 243-249
-
-
Xuong, N.H.1
-
22
-
-
20544451502
-
Active pixel sensor array as a detector for electron microscopy
-
A. C. Milazzo, P. Leblanc, F. Duttweiler, L. Jin, J. C. Bouwer, S. Peltier, M. Ellisman, F. Bieser, H. S. Matis, H. Wieman, P. Denes, S. Kleinfelder, and N. H. Xuong, "Active pixel sensor array as a detector for electron microscopy," Ultramicroscopy, vol. 104, pp. 152-159, 2005.
-
(2005)
Ultramicroscopy
, vol.104
, pp. 152-159
-
-
Milazzo, A.C.1
Leblanc, P.2
Duttweiler, F.3
Jin, L.4
Bouwer, J.C.5
Peltier, S.6
Ellisman, M.7
Bieser, F.8
Matis, H.S.9
Wieman, H.10
Denes, P.11
Kleinfelder, S.12
Xuong, N.H.13
|