-
1
-
-
0027540056
-
-
J. P. Cleveland, S. Manne, D. Bocek, and P. K. Hansma, Rev. Sci. Instrum. 64, 403 (1993).
-
(1993)
Rev. Sci. Instrum.
, vol.64
, pp. 403
-
-
Cleveland, J.P.1
Manne, S.2
Bocek, D.3
Hansma, P.K.4
-
7
-
-
0034736604
-
-
G. Bogdanovic, A. Meurk, and M. W. Rutland, Colloids Surf., B 19, 397 (2000).
-
(2000)
Colloids Surf., B
, vol.19
, pp. 397
-
-
Bogdanovic, G.1
Meurk, A.2
Rutland, M.W.3
-
14
-
-
3042756088
-
-
note
-
Using finite element analysis, (Ref. 20) it is found that the distance between the center of the mass and the neutral axis of the cantilever, when the mass is aligned with the major axis of the cantilever, has an insignificant effect on the torsional mode of deformation, i.e., coupling into other modes is negligible.
-
-
-
-
15
-
-
3042830371
-
-
note
-
This condition is typically satisfied in practice.
-
-
-
-
16
-
-
36449002856
-
-
J. E. Sader, I. Larson, P. Mulvaney, and L. R. White, Rev. Sci. Instrum. 66, 3789 (1995).
-
(1995)
Rev. Sci. Instrum.
, vol.66
, pp. 3789
-
-
Sader, J.E.1
Larson, I.2
Mulvaney, P.3
White, L.R.4
-
20
-
-
3042758423
-
-
LUSAS, Finite Element Analysis Ltd., Forge House, 66 High St., Kingston upon Thames, Surrey KT1 IHN, UK
-
LUSAS, Finite Element Analysis Ltd., Forge House, 66 High St., Kingston upon Thames, Surrey KT1 IHN, UK.
-
-
-
-
25
-
-
3042715169
-
-
Veeco, 1171 Borregas Ave., Sunnyvale, CA 94089
-
Veeco, 1171 Borregas Ave., Sunnyvale, CA 94089.
-
-
-
-
27
-
-
3042753735
-
-
note
-
The signal was collected and digitized using a data acquisition board (Ref. 28). Multiple measurements were taken. These were then windowed together using a Hanning function, fast Fourier transformed, and finally averaged together to obtain the required thermal noise spectra (Ref. 29).
-
-
-
-
28
-
-
3042837299
-
-
National Instruments, 6504 Bridge Point Parkway, Austin. TX 78730-5039. The model used was the AT-MIO-16E-1 DAQ
-
National Instruments, 6504 Bridge Point Parkway, Austin. TX 78730-5039. The model used was the AT-MIO-16E-1 DAQ.
-
-
-
-
29
-
-
50449090262
-
-
available from National Instruments (see Ref. 28)
-
LabVIEW software, available from National Instruments (see Ref. 28).
-
LabVIEW Software
-
-
-
30
-
-
3042796885
-
-
note
-
t, and Q.
-
-
-
-
31
-
-
3042787624
-
-
Digital Instruments, 112 Robin Hill Road, Santa Barbara, CA 93117
-
Digital Instruments, 112 Robin Hill Road, Santa Barbara, CA 93117.
-
-
-
-
32
-
-
3042799266
-
-
note
-
To ensure that the spheres were aligned with their center of mass as close to the major axis of the cantilever as possible, we measured the horizontal position of the spheres and only used those results in which the off-axis distance was small (≲ 1 μm).
-
-
-
-
33
-
-
0003918362
-
-
edited by M. Bauccio (ASM International, Materials Park, OH)
-
Engineering Materials Reference Book, 2nd ed., edited by M. Bauccio (ASM International, Materials Park, OH, 1994).
-
(1994)
Engineering Materials Reference Book, 2nd Ed.
-
-
-
34
-
-
0035504209
-
-
S. Ecke, R. Raiteri, E. Bonaccurso, C. Reiner, H. J. Deiseroth, and H. J. Butt, Rev. Sci. Instrum. 72, 4164 (2001).
-
(2001)
Rev. Sci. Instrum.
, vol.72
, pp. 4164
-
-
Ecke, S.1
Raiteri, R.2
Bonaccurso, E.3
Reiner, C.4
Deiseroth, H.J.5
Butt, H.J.6
|