-
1
-
-
51849108672
-
-
WHO Global Database on Anemia, B. de Benoist, E. McLean, I. Egli & M. Cogswell, Eds. Geneva World Health Organization. Accessed October 25, 2018
-
World Health Organization (WHO). 2008. Worldwide prevalence of anemia, 1993–2005. In WHO Global Database on Anemia. B. de Benoist, E. McLean, I. Egli & M. Cogswell, Eds. Geneva: World Health Organization. Accessed October 25, 2018. http://whqlibdoc.who.int/publications/2008/9789241596657_eng.pdf?ua=1.
-
(2008)
Worldwide prevalence of anemia, 1993–2005
-
-
-
2
-
-
65449184945
-
Worldwide prevalence of anaemia, WHO Vitamin and Mineral Nutrition System, 1993–2005
-
McLean, E., M. Cogswell, I. Egli, et al. 2009. Worldwide prevalence of anaemia, WHO Vitamin and Mineral Nutrition System, 1993–2005. Public Health Nutr. 12: 444–454.
-
(2009)
Public Health Nutr
, vol.12
, pp. 444-454
-
-
McLean, E.1
Cogswell, M.2
Egli, I.3
-
4
-
-
84963706401
-
The global burden of anemia
-
Kassebaum, N.J. 2016. GBD 2013 Anemia Collaborators. The global burden of anemia. Hematol. Oncol. Clin. North Am. 30: 247–308.
-
(2016)
Hematol. Oncol. Clin. North Am
, vol.30
, pp. 247-308
-
-
Kassebaum, N.J.1
-
5
-
-
83955164266
-
Anaemia in low-income and middle-income countries
-
Balarajan, Y., U. Ramakrishnan, E. Ozaltin, et al. 2011. Anaemia in low-income and middle-income countries. Lancet 378: 2123–2135.
-
(2011)
Lancet
, vol.378
, pp. 2123-2135
-
-
Balarajan, Y.1
Ramakrishnan, U.2
Ozaltin, E.3
-
6
-
-
84860543263
-
Haemoglobin variants and Plasmodium falciparum malaria in children under five years of age living in a high and seasonal malaria transmission area of Burkina Faso
-
Bougouma, E.C., A.B. Tiono, A. Ouedraogo, et al. 2012. Haemoglobin variants and Plasmodium falciparum malaria in children under five years of age living in a high and seasonal malaria transmission area of Burkina Faso. Malaria J. 11: 154.
-
(2012)
Malaria J
, vol.11
, pp. 154
-
-
Bougouma, E.C.1
Tiono, A.B.2
Ouedraogo, A.3
-
8
-
-
85015197947
-
Accuracy of capillary hemoglobin measurements for the detection of anemia in the U.S. low-income toddlers and pregnant women
-
Boghani, S., Z. Mei, G.S. Perry, et al. 2017. Accuracy of capillary hemoglobin measurements for the detection of anemia in the U.S. low-income toddlers and pregnant women. Nutrients 9: E253.
-
(2017)
Nutrients
, vol.9
-
-
Boghani, S.1
Mei, Z.2
Perry, G.S.3
-
9
-
-
85026452931
-
Techniques used for blood screening of hemoglobin levels in blood donors: current insights and future directions
-
Chaudhary, R., A. Dubey & A. Sonker. 2017. Techniques used for blood screening of hemoglobin levels in blood donors: current insights and future directions. J. Blood Med. 8: 75–88.
-
(2017)
J. Blood Med
, vol.8
, pp. 75-88
-
-
Chaudhary, R.1
Dubey, A.2
Sonker, A.3
-
11
-
-
85017513639
-
Effects of preanalytical factors on hemoglobin measurement: a comparison of two HemoCue® point-of-care analyzers
-
Whitehead, Jr., R.D., M. Zhang, M.R. Sternberg, et al. 2017. Effects of preanalytical factors on hemoglobin measurement: a comparison of two HemoCue® point-of-care analyzers. Clin. Biochem. 50: 513–520.
-
(2017)
Clin. Biochem
, vol.50
, pp. 513-520
-
-
Whitehead, R.D.1
Zhang, M.2
Sternberg, M.R.3
-
12
-
-
85066971766
-
Comparison between field research and controlled laboratory research
-
Aziz, H.A. 2017. Comparison between field research and controlled laboratory research. Arch. Clin. Biomed. Res. 1: 101–104.
-
(2017)
Arch. Clin. Biomed. Res
, vol.1
, pp. 101-104
-
-
Aziz, H.A.1
-
13
-
-
48549092221
-
Design, analysis and interpretation of method-comparison studies
-
Hanneman, S.K. 2008. Design, analysis and interpretation of method-comparison studies. AACN Adv. Crit. Care 19: 223–234.
-
(2008)
AACN Adv. Crit. Care
, vol.19
, pp. 223-234
-
-
Hanneman, S.K.1
-
14
-
-
84868295836
-
Biological variation of hematology tests based on the 1999–2002 National Health and Nutrition Examination Survey
-
Lacher, D.A., J. Barletta & J.P. Hughes. 2012. Biological variation of hematology tests based on the 1999–2002 National Health and Nutrition Examination Survey. Natl. Health Stat. Rep. 54: 1–10.
-
(2012)
Natl. Health Stat. Rep
, vol.54
, pp. 1-10
-
-
Lacher, D.A.1
Barletta, J.2
Hughes, J.P.3
-
15
-
-
35348956391
-
Laboratory costs of a hospital-based blood transfusion service in Malawi
-
Lara, A.M., J. Kandulu, L. Chisuwo, et al. 2007. Laboratory costs of a hospital-based blood transfusion service in Malawi. J. Clin. Pathol. 60: 1117–1120.
-
(2007)
J. Clin. Pathol
, vol.60
, pp. 1117-1120
-
-
Lara, A.M.1
Kandulu, J.2
Chisuwo, L.3
-
16
-
-
0024521543
-
A concordance correlation coefficient to evaluate reproducibility
-
Lin, L.I.K. 1989. A concordance correlation coefficient to evaluate reproducibility. Biometrics 45: 255–268.
-
(1989)
Biometrics
, vol.45
, pp. 255-268
-
-
Lin, L.I.K.1
-
17
-
-
84922434841
-
Development, history, and future of automated cell counters
-
Green, R. & S. Wachsmann-Hogiu. 2015. Development, history, and future of automated cell counters. Clin. Lab. Med. 35: 1–10.
-
(2015)
Clin. Lab. Med
, vol.35
, pp. 1-10
-
-
Green, R.1
Wachsmann-Hogiu, S.2
-
18
-
-
84963668249
-
Diagnostic accuracy of the HemoCue Hb 301, STAT-Site MHgb and URIT-12 Point-of-Care hemoglobin meters in a central laboratory and a community based clinic in Durban, South Africa
-
Jaggernath, M., R. Naicker, S. Madurai, et al. 2016. Diagnostic accuracy of the HemoCue Hb 301, STAT-Site MHgb and URIT-12 Point-of-Care hemoglobin meters in a central laboratory and a community based clinic in Durban, South Africa. PLoS One 11: e0152184.
-
(2016)
PLoS One
, vol.11
-
-
Jaggernath, M.1
Naicker, R.2
Madurai, S.3
-
19
-
-
41849147528
-
Comparison of the analytic performance between the B-HB and HB-201+ HemoCue® hemoglobinometers for venous and capillary blood under field work conditions
-
Monárrez-Espino, J. & N. Roos. 2008. Comparison of the analytic performance between the B-HB and HB-201+ HemoCue® hemoglobinometers for venous and capillary blood under field work conditions. Ecol. Food Nutr. 47: 159–169.
-
(2008)
Ecol. Food Nutr.
, vol.47
, pp. 159-169
-
-
Monárrez-Espino, J.1
Roos, N.2
-
20
-
-
50349105074
-
The use of the copper sulfate method of hemoglobin estimation for screening blood donors
-
Boynton, M.H. 1946. The use of the copper sulfate method of hemoglobin estimation for screening blood donors. Transl. Res. 31: 40–44.
-
(1946)
Transl. Res.
, vol.31
, pp. 40-44
-
-
Boynton, M.H.1
-
21
-
-
0023869643
-
Haemoglobin estimate—reliability of the copper sulphate specific gravity v. cyanmethaemoglobin colorimetric method
-
Politzer, W.M., W.M. Myburgh & J.F. Van der Merwe. 1988. Haemoglobin estimate—reliability of the copper sulphate specific gravity v. cyanmethaemoglobin colorimetric method. S. Afr. Med. J. 73: 111–112.
-
(1988)
S. Afr. Med. J.
, vol.73
, pp. 111-112
-
-
Politzer, W.M.1
Myburgh, W.M.2
Van der Merwe, J.F.3
-
22
-
-
0015323897
-
Evaluation of cyanmethaemoglobin method for haemoglobin estimation
-
Prakash, N. & H.N. Banerji. 1972. Evaluation of cyanmethaemoglobin method for haemoglobin estimation. Indian J. Chest Dis. 14: 102–105.
-
(1972)
Indian J. Chest Dis.
, vol.14
, pp. 102-105
-
-
Prakash, N.1
Banerji, H.N.2
-
24
-
-
0031889562
-
An inexpensive and reliable new haemoglobin colour scale for assessing anaemia
-
Lewis, S.M., G.J. Stott & K.J. Wynn. 1998. An inexpensive and reliable new haemoglobin colour scale for assessing anaemia. J. Clin. Pathol. 51: 21–24.
-
(1998)
J. Clin. Pathol.
, vol.51
, pp. 21-24
-
-
Lewis, S.M.1
Stott, G.J.2
Wynn, K.J.3
-
25
-
-
84891534564
-
Simple paper-based test for measuring blood hemoglobin concentration in resource-limited settings
-
Yang, X., N. Piety, S.M. Vignes, et al. 2013. Simple paper-based test for measuring blood hemoglobin concentration in resource-limited settings. Clin. Chem. 59: 1506–1513.
-
(2013)
Clin. Chem.
, vol.59
, pp. 1506-1513
-
-
Yang, X.1
Piety, N.2
Vignes, S.M.3
-
26
-
-
0013870275
-
Haemoglobin estimation: a comparison of different techniques
-
Elwood, P.C. & A. Jacobs. 1966. Haemoglobin estimation: a comparison of different techniques. Br. Med. J. 1: 20–24.
-
(1966)
Br. Med. J
, vol.1
, pp. 20-24
-
-
Elwood, P.C.1
Jacobs, A.2
-
27
-
-
48749100326
-
Pattern of haemoglobin among high and low altitude children of southwestern Saudi Arabia
-
Al-Hashem, F.H. 2006. Pattern of haemoglobin among high and low altitude children of southwestern Saudi Arabia. J. Family Community Med. 13: 35–40.
-
(2006)
J. Family Community Med
, vol.13
, pp. 35-40
-
-
Al-Hashem, F.H.1
-
28
-
-
84949970845
-
-
Geneva World Health Organization;, Accessed October 25, 2018
-
World Health Organization (WHO). Global nutrition targets 2025: policy brief series. Geneva: World Health Organization; 2014. Accessed October 25, 2018. http://apps.who.int/iris/bitstream/10665/149018/1/WHO_NMH_NHD_14.2_eng.pdf?ua=1.
-
(2014)
Global nutrition targets 2025: policy brief series
-
-
-
29
-
-
0000656808
-
Measurement of specific gravities of whole blood and plasma by standard copper sulfate solutions
-
Phillips, R.A., D.D. Van Slyke, P.B. Hamilton, et al. 1950. Measurement of specific gravities of whole blood and plasma by standard copper sulfate solutions. J. Biol. Chem. 183: 305–330.
-
(1950)
J. Biol. Chem
, vol.183
, pp. 305-330
-
-
Phillips, R.A.1
Van Slyke, D.D.2
Hamilton, P.B.3
-
30
-
-
1842833629
-
Laboratory practice at the periphery in developing countries
-
Lewis, S.M. 2002. Laboratory practice at the periphery in developing countries. Int. J. Hematol. 76(Suppl. 1): 294–298.
-
(2002)
Int. J. Hematol
, vol.76
, pp. 294-298
-
-
Lewis, S.M.1
-
31
-
-
84961411532
-
Methods for hemoglobin estimation: a review of “what works
-
Srivastava, T., H. Negandhi, S.B. Neogi, et al. 2014. Methods for hemoglobin estimation: a review of “what works.” J. Hematol. Transfus. 2: 1028.
-
(2014)
J. Hematol. Transfus.
, vol.2
, pp. 1028
-
-
Srivastava, T.1
Negandhi, H.2
Neogi, S.B.3
-
32
-
-
0023006885
-
Quality control in hematology
-
Gulati, G.L. & B.H. Hyun. 1986. Quality control in hematology. Clin. Lab. Med. 6: 675–688.
-
(1986)
Clin. Lab. Med
, vol.6
, pp. 675-688
-
-
Gulati, G.L.1
Hyun, B.H.2
-
33
-
-
0022543618
-
Accurate and independent measurement of volume and hemoglobin concentration of individual red cells by laser light scattering
-
Mohandas, N., Y. Kim, D. Tycko, et al. 1986. Accurate and independent measurement of volume and hemoglobin concentration of individual red cells by laser light scattering. Blood 68: 506–513.
-
(1986)
Blood
, vol.68
, pp. 506-513
-
-
Mohandas, N.1
Kim, Y.2
Tycko, D.3
-
34
-
-
85067059746
-
-
World Health Organization;, Accessed October 25, 2018
-
World Health Organization (WHO). Review of the haemoglobin colour scale. World Health Organization; 2004. Accessed October 25, 2018. http://apps.who.int/iris/bitstream/10665/68734/2/WHO_EHT_04.12.pdf.
-
(2004)
Review of the haemoglobin colour scale
-
-
-
35
-
-
84900035442
-
Validation of the WHO Hemoglobin Color Scale method
-
Darshana, L.G. & D.I. Uluwaduge. 2014. Validation of the WHO Hemoglobin Color Scale method. Anemia 2014. https://doi.org/10.1155/2014/531670.
-
(2014)
Anemia
, vol.2014
-
-
Darshana, L.G.1
Uluwaduge, D.I.2
-
36
-
-
84962616586
-
Accuracy of the WHO Haemoglobin Colour Scale for the diagnosis of anaemia in primary health care settings in low-income countries: a systematic review and meta-analysis
-
Marn, H. & J.A. Critchley. 2016. Accuracy of the WHO Haemoglobin Colour Scale for the diagnosis of anaemia in primary health care settings in low-income countries: a systematic review and meta-analysis. Lancet Glob. Health 4: e251–e265.
-
(2016)
Lancet Glob. Health
, vol.4
, pp. e251-e265
-
-
Marn, H.1
Critchley, J.A.2
-
37
-
-
0032789976
-
Evaluation of the HB-Quick: a portable hemoglobinometer
-
Gong, A.K. & B. Backenstose. 1999. Evaluation of the HB-Quick: a portable hemoglobinometer. J. Clin. Monit. Comput. 15: 171–177.
-
(1999)
J. Clin. Monit. Comput
, vol.15
, pp. 171-177
-
-
Gong, A.K.1
Backenstose, B.2
-
38
-
-
85067081400
-
-
Accessed October 25, 2018
-
HemoCue America. Hb-201+ Product Sheet. Accessed October 25, 2018. http://www.hemocue.us/~/media/hemocue-images/hemocue_us-images/pdf/hemoglobin-lit1056-hb-201product-sheet.pdf?la=en-US.
-
Hb-201+ Product Sheet
-
-
-
39
-
-
85067082406
-
-
Accessed October 25, 2018
-
HemoCue America. Hb-301 Product Sheet. Accessed October 25, 2018. http://www.hemocue.us/~/media/hemocue-images/hemocue_us-images/pdf/hemoglobin-lit6052-hb-301-productprofile.pdf?la=en-US.
-
Hb-301 Product Sheet
-
-
-
40
-
-
84897026681
-
Validation of a non-invasive pulse CO-oximetry based hemoglobin estimation in normal blood donors
-
Al-Khabori, M., A.Z. Al-Riyami, K. Al-Farsi, et al. 2014. Validation of a non-invasive pulse CO-oximetry based hemoglobin estimation in normal blood donors. Transfus. Apher. Sci. 50: 95–98.
-
(2014)
Transfus. Apher. Sci
, vol.50
, pp. 95-98
-
-
Al-Khabori, M.1
Al-Riyami, A.Z.2
Al-Farsi, K.3
-
41
-
-
84890485688
-
Use of non-invasive total hemoglobin measurement as a screening tool for anemia in children
-
Amano, I. & A. Murakami. 2013. Use of non-invasive total hemoglobin measurement as a screening tool for anemia in children. Pediatr. Int. 55: 803–835.
-
(2013)
Pediatr. Int
, vol.55
, pp. 803-835
-
-
Amano, I.1
Murakami, A.2
-
42
-
-
84923111991
-
Comparison of three noninvasive methods for hemoglobin screening of blood donors
-
Ardin, S., M. Störmer, S. Radojska, et al. 2015. Comparison of three noninvasive methods for hemoglobin screening of blood donors. Transfusion 55: 379–387.
-
(2015)
Transfusion
, vol.55
, pp. 379-387
-
-
Ardin, S.1
Störmer, M.2
Radojska, S.3
-
43
-
-
84941743402
-
Clinical evaluation of a novel technology for non-invasive and continuous measurement of plasma haemoglobin concentration
-
Broderick, A.J., F. Desmond, G. Leen & G. Shorten. 2015. Clinical evaluation of a novel technology for non-invasive and continuous measurement of plasma haemoglobin concentration. Anaesthesia 70: 1165–1170.
-
(2015)
Anaesthesia
, vol.70
, pp. 1165-1170
-
-
Broderick, A.J.1
Desmond, F.2
Leen, G.3
Shorten, G.4
-
44
-
-
84958106545
-
Diagnostic accuracy of haemoglobin colour strip (HCS-HLL), a digital haemoglobinometer (TrueHb) and a non-invasive device (TouchHb) for screening patients with anaemia
-
Neogi, S.B., H. Negandhi, R. Kar, et al. 2016. Diagnostic accuracy of haemoglobin colour strip (HCS-HLL), a digital haemoglobinometer (TrueHb) and a non-invasive device (TouchHb) for screening patients with anaemia. J. Clin. Pathol. 69: 164–170.
-
(2016)
J. Clin. Pathol
, vol.69
, pp. 164-170
-
-
Neogi, S.B.1
Negandhi, H.2
Kar, R.3
-
45
-
-
85067011043
-
-
Accessed October 25, 2018
-
Biosense. ToucHb. Accessed October 25, 2018. http://www.biosense.in/touchb.html.
-
ToucHb
-
-
-
46
-
-
85067068629
-
-
Accessed October 25, 2018
-
Masimo. About Masimo. Accessed October 25, 2018. http://www.masimo.com/About-Masimo/about-masimo/.
-
About Masimo
-
-
-
47
-
-
84907484215
-
Disposable platform provides visual and color-based point-of-care anemia self-testing
-
Tyburski, E.A., S.E. Gillespie, W.A. Stoy, et al. 2014. Disposable platform provides visual and color-based point-of-care anemia self-testing. J. Clin. Invest. 124: 4387–4394.
-
(2014)
J. Clin. Invest
, vol.124
, pp. 4387-4394
-
-
Tyburski, E.A.1
Gillespie, S.E.2
Stoy, W.A.3
-
48
-
-
0017682341
-
Hemoglobin screening in prospective blood donors: a comparison of methods
-
Avoy, D.R., M.L. Canuel, B.M. Otton & E.B. Mileski. 1977. Hemoglobin screening in prospective blood donors: a comparison of methods. Transfusion 17: 261–264.
-
(1977)
Transfusion
, vol.17
, pp. 261-264
-
-
Avoy, D.R.1
Canuel, M.L.2
Otton, B.M.3
Mileski, E.B.4
-
49
-
-
77049141431
-
The ear lobe as a source of blood in haemoglobin estimation
-
Henderson, A.S. 1953. The ear lobe as a source of blood in haemoglobin estimation. J. Physiol. 121: 43P–44P.
-
(1953)
J. Physiol
, vol.121
, pp. 43P-44P
-
-
Henderson, A.S.1
-
50
-
-
84924923754
-
Fortuitous factors affecting the leucocyte count in blood from the ear
-
Lucy, H.C. 1950. Fortuitous factors affecting the leucocyte count in blood from the ear. J. Clin. Pathol. 3: 146–151.
-
(1950)
J. Clin. Pathol
, vol.3
, pp. 146-151
-
-
Lucy, H.C.1
-
51
-
-
0026541825
-
A clinical evaluation of the HemoCue haemoglobinometer using capillary, venous, and arterial samples
-
Chen, P.P., T.G. Short, D.H.Y. Leung & T.E. Oh. 1992. A clinical evaluation of the HemoCue haemoglobinometer using capillary, venous, and arterial samples. Anaesth. Intensive Care 20: 497–503.
-
(1992)
Anaesth. Intensive Care
, vol.20
, pp. 497-503
-
-
Chen, P.P.1
Short, T.G.2
Leung, D.H.Y.3
Oh, T.E.4
-
52
-
-
0035724137
-
Comparison of blood counts in venous, fingertip and arterial blood and their measurement variation
-
Yang, Z.W., S.H. Yang, L. Chen, et al. 2001. Comparison of blood counts in venous, fingertip and arterial blood and their measurement variation. Clin. Lab. Haematol. 23: 155–159.
-
(2001)
Clin. Lab. Haematol
, vol.23
, pp. 155-159
-
-
Yang, Z.W.1
Yang, S.H.2
Chen, L.3
-
53
-
-
0022635586
-
2 tension: a mathematical analysis
-
2 tension: a mathematical analysis. Respir. Physiol. 63: 79–96.
-
(1986)
Respir. Physiol
, vol.63
, pp. 79-96
-
-
Gutierrez, G.1
-
54
-
-
84876731478
-
Capillary versus venous haemoglobin determination in the assessment of healthy blood donors
-
Patel, A.J., R. Wesley, S.F. Leitman & B.J. Bryant. 2013. Capillary versus venous haemoglobin determination in the assessment of healthy blood donors. Vox Sang. 104: 317–323.
-
(2013)
Vox Sang.
, vol.104
, pp. 317-323
-
-
Patel, A.J.1
Wesley, R.2
Leitman, S.F.3
Bryant, B.J.4
-
55
-
-
33846649444
-
Arterial versus capillary blood gases: a meta-analysis
-
Zavorsky, G.S., J. Cao, N.E. Mayo, et al. 2007. Arterial versus capillary blood gases: a meta-analysis. Respir. Physiol. Neurobiol. 155: 268–279.
-
(2007)
Respir. Physiol. Neurobiol
, vol.155
, pp. 268-279
-
-
Zavorsky, G.S.1
Cao, J.2
Mayo, N.E.3
-
56
-
-
1842846647
-
Hemoglobin measured by Hemocue and a reference method in venous and capillary blood: a validation study
-
Neufeld, L., A. García-Guerra, D. Sánchez-Francia, et al. 2002. Hemoglobin measured by Hemocue and a reference method in venous and capillary blood: a validation study. Salud Publica Mex. 44: 219–227.
-
(2002)
Salud Publica Mex
, vol.44
, pp. 219-227
-
-
Neufeld, L.1
García-Guerra, A.2
Sánchez-Francia, D.3
-
57
-
-
0023792468
-
A comparison between haematological parameters in ‘capillary’ and venous blood from healthy adults
-
Daae, L.N.W., S. Halvorsen, P.M. Mathisen & K. Mironska. 1988. A comparison between haematological parameters in ‘capillary’ and venous blood from healthy adults. Scand. J. Clin. Lab. Invest. 48: 723–726.
-
(1988)
Scand. J. Clin. Lab. Invest
, vol.48
, pp. 723-726
-
-
Daae, L.N.W.1
Halvorsen, S.2
Mathisen, P.M.3
Mironska, K.4
-
58
-
-
0024498170
-
Evaluation of methods and protocols for hemoglobin screening of prospective whole blood donors
-
Chambers, L.A. & J.M. McGuff. 1989. Evaluation of methods and protocols for hemoglobin screening of prospective whole blood donors. Am. J. Clin. Pathol. 91: 309–312.
-
(1989)
Am. J. Clin. Pathol
, vol.91
, pp. 309-312
-
-
Chambers, L.A.1
McGuff, J.M.2
-
59
-
-
0026317758
-
A comparison between haematological parameters in ‘capillary’ and venous blood from hospitalized children aged 3 months to 14 years
-
Daae, L.N.W., M. Hallerud & S. Halvorsen. 1991. A comparison between haematological parameters in ‘capillary’ and venous blood from hospitalized children aged 3 months to 14 years. Scand. J. Clin. Lab. Invest. 51: 651–654.
-
(1991)
Scand. J. Clin. Lab. Invest
, vol.51
, pp. 651-654
-
-
Daae, L.N.W.1
Hallerud, M.2
Halvorsen, S.3
-
60
-
-
4544365096
-
Comparison between the HemoCue and an automated counter for measuring hemoglobin
-
Paiva Ade, A., P.H. Rondó, S.S. Silva & R. Latorre Mdo. 2004. Comparison between the HemoCue and an automated counter for measuring hemoglobin. Rev. Saude Publica 38: 585–587.
-
(2004)
Rev. Saude Publica
, vol.38
, pp. 585-587
-
-
Paiva Ade, A.1
Rondó, P.H.2
Silva, S.S.3
Latorre Mdo, R.4
-
61
-
-
83555174543
-
Reliability of capillary hemoglobin screening under routine conditions
-
Ziemann, M., B. Lizardo, G. Geusendam & P. Schlenke. 2011. Reliability of capillary hemoglobin screening under routine conditions. Transfusion 51: 2714–2719.
-
(2011)
Transfusion
, vol.51
, pp. 2714-2719
-
-
Ziemann, M.1
Lizardo, B.2
Geusendam, G.3
Schlenke, P.4
-
62
-
-
85067002940
-
Evaluation of hemoglobin concentration of cord, capillary and venous sampling in neonates
-
Eslami, Z., R. Ghilian & F. Abbasi. 2012. Evaluation of hemoglobin concentration of cord, capillary and venous sampling in neonates. Iran J. Ped. Hematol. Oncol. 2: 159–163.
-
(2012)
Iran J. Ped. Hematol. Oncol.
, vol.2
, pp. 159-163
-
-
Eslami, Z.1
Ghilian, R.2
Abbasi, F.3
-
63
-
-
84947968161
-
Drop-to-drop variation in the cellular components of fingerprick blood
-
Bond, M.M. & R.R. Richards-Kortum. 2015. Drop-to-drop variation in the cellular components of fingerprick blood. Am. J. Clin. Pathol. 144: 885–894.
-
(2015)
Am. J. Clin. Pathol
, vol.144
, pp. 885-894
-
-
Bond, M.M.1
Richards-Kortum, R.R.2
-
64
-
-
84942989290
-
Portable hemoglobinometer is a reliable technology for the follow-up of venesections tolerance in hemochromatosis
-
Pawlowski, M., F. Latute, E. Bardou-Jacquet, et al. 2015. Portable hemoglobinometer is a reliable technology for the follow-up of venesections tolerance in hemochromatosis. Clin. Res. Hepatol. Gastroenterol. 39: 570–575.
-
(2015)
Clin. Res. Hepatol. Gastroenterol
, vol.39
, pp. 570-575
-
-
Pawlowski, M.1
Latute, F.2
Bardou-Jacquet, E.3
-
65
-
-
85031037330
-
Mean hemoglobin concentrations in fasting venous and non-fasting capillary blood of Cambodian women using a hemoglobinometer and an automated hematology analyzer
-
Karakochuk, C.D., A.I. Rappaport, S.I. Barr & T.J. Green. 2017. Mean hemoglobin concentrations in fasting venous and non-fasting capillary blood of Cambodian women using a hemoglobinometer and an automated hematology analyzer. Clin. Chem. Lab. Med. 95: e247–e250.
-
(2017)
Clin. Chem. Lab. Med
, vol.95
, pp. e247-e250
-
-
Karakochuk, C.D.1
Rappaport, A.I.2
Barr, S.I.3
Green, T.J.4
-
66
-
-
0031966529
-
Measurement of haemoglobin using single drops of skin puncture blood: is precision acceptable?
-
Conway, A.M., R.F. Hinchiffe, J. Earland & L.M. Anderson. 1998. Measurement of haemoglobin using single drops of skin puncture blood: is precision acceptable? J. Clin. Pathol. 51: 248–250.
-
(1998)
J. Clin. Pathol
, vol.51
, pp. 248-250
-
-
Conway, A.M.1
Hinchiffe, R.F.2
Earland, J.3
Anderson, L.M.4
-
67
-
-
85015267581
-
Patient posture for blood collection by venipuncture: recall for standardization after 28 years
-
Lima-Oliveira, G., G.C. Guidi, G.L. Salvagno, et al. 2017. Patient posture for blood collection by venipuncture: recall for standardization after 28 years. Rev. Bras. Hematol. Hemoter. 39: 127–132.
-
(2017)
Rev. Bras. Hematol. Hemoter
, vol.39
, pp. 127-132
-
-
Lima-Oliveira, G.1
Guidi, G.C.2
Salvagno, G.L.3
-
68
-
-
55349142107
-
Effects of delayed sample processing and freezing on serum concentrations of selected nutritional indicators
-
Drammeh, B.S., R.L. Schleicher, C.M. Pfeiffer, et al. 2008. Effects of delayed sample processing and freezing on serum concentrations of selected nutritional indicators. Clin. Chem. 54: 1883–1891.
-
(2008)
Clin. Chem
, vol.54
, pp. 1883-1891
-
-
Drammeh, B.S.1
Schleicher, R.L.2
Pfeiffer, C.M.3
-
70
-
-
0034884646
-
Use of a new HemoCue system for measuring haemoglobin at low concentrations
-
Morris, L.D., A. Pont & S.M. Lewis. 2001. Use of a new HemoCue system for measuring haemoglobin at low concentrations. Clin. Lab. Haematol. 23: 91–96.
-
(2001)
Clin. Lab. Haematol
, vol.23
, pp. 91-96
-
-
Morris, L.D.1
Pont, A.2
Lewis, S.M.3
-
71
-
-
0036042209
-
High humidity affects HemoCue cuvette function and HemoCue haemoglobin estimation in tropical Australia
-
Nguyen, H.T. 2002. High humidity affects HemoCue cuvette function and HemoCue haemoglobin estimation in tropical Australia. J. Paediatr. Child Health 38: 427–428.
-
(2002)
J. Paediatr. Child Health
, vol.38
, pp. 427-428
-
-
Nguyen, H.T.1
-
72
-
-
0025195608
-
An evaluation of the HemoCue for correcting the haemoglobin value of lipaemic samples
-
Nicholls, P.D. 1990. An evaluation of the HemoCue for correcting the haemoglobin value of lipaemic samples. Med. Lab. Sci. 47: 226–229.
-
(1990)
Med. Lab. Sci
, vol.47
, pp. 226-229
-
-
Nicholls, P.D.1
-
73
-
-
0029314397
-
High humidity affects HemoCue microcuvette function
-
Henderson, M.A. & M.G. Irwin. 1995. High humidity affects HemoCue microcuvette function. Anaesth. Intensive Care 23: 407.
-
(1995)
Anaesth. Intensive Care
, vol.23
, pp. 407
-
-
Henderson, M.A.1
Irwin, M.G.2
-
74
-
-
0035240945
-
Validity of the haemoglobin colour scale in blood donor screening
-
Lewis, S.M. & J. Emmanuel. 2001. Validity of the haemoglobin colour scale in blood donor screening. Vox Sang. 80: 28–33.
-
(2001)
Vox Sang
, vol.80
, pp. 28-33
-
-
Lewis, S.M.1
Emmanuel, J.2
-
76
-
-
0029792511
-
Haemoglobin values in venous and skin puncture blood
-
Hinchliffe, R.F. & L.M. Anderson. 1996. Haemoglobin values in venous and skin puncture blood. Arch. Dis. Child. 75: 170–171.
-
(1996)
Arch. Dis. Child
, vol.75
, pp. 170-171
-
-
Hinchliffe, R.F.1
Anderson, L.M.2
-
79
-
-
80053639020
-
Quality evaluation of four hemoglobin screening methods in a blood donor setting along with their comparative cost analysis in an Indian scenario
-
Tondon, R., A. Verma, P. Pandey & R. Chaudhary. 2009. Quality evaluation of four hemoglobin screening methods in a blood donor setting along with their comparative cost analysis in an Indian scenario. Asian J. Transfus. Sci. 3: 66–69.
-
(2009)
Asian J. Transfus. Sci
, vol.3
, pp. 66-69
-
-
Tondon, R.1
Verma, A.2
Pandey, P.3
Chaudhary, R.4
-
80
-
-
85018730543
-
Anemia in prospective blood donors deferred by the copper sulphate technique of hemoglobin estimation
-
Antwi-Baffour, S., D.K. Annor, J.K. Adjei, et al. 2015. Anemia in prospective blood donors deferred by the copper sulphate technique of hemoglobin estimation. BMC Hematol. 15: 15.
-
(2015)
BMC Hematol
, vol.15
, pp. 15
-
-
Antwi-Baffour, S.1
Annor, D.K.2
Adjei, J.K.3
-
82
-
-
0032977421
-
Diagnosing anaemia in pregnancy in rural clinics: assessing the potential of the Haemoglobin Colour Scale
-
van den Broek, N.R., C. Ntonya, E. Mhango & S.A. White. 1999. Diagnosing anaemia in pregnancy in rural clinics: assessing the potential of the Haemoglobin Colour Scale. Bull. World Health Organ. 77: 15–21.
-
(1999)
Bull. World Health Organ
, vol.77
, pp. 15-21
-
-
van den Broek, N.R.1
Ntonya, C.2
Mhango, E.3
White, S.A.4
-
83
-
-
0033665809
-
Clinical use of WHO haemoglobin colour scale: validation and critique
-
Ingram, C.F. & S.M. Lewis. 2000. Clinical use of WHO haemoglobin colour scale: validation and critique. J. Clin. Pathol. 53: 933–937.
-
(2000)
J. Clin. Pathol
, vol.53
, pp. 933-937
-
-
Ingram, C.F.1
Lewis, S.M.2
-
84
-
-
34248199333
-
Evaluation of hemoglobin of blood donors deferred by the copper sulphate method for hemoglobin estimation
-
Sawant, R.B., Z.S. Bharucha & S.B. Rajadhyaksha. 2007. Evaluation of hemoglobin of blood donors deferred by the copper sulphate method for hemoglobin estimation. Transfus. Apher. Sci. 36: 143–148.
-
(2007)
Transfus. Apher. Sci
, vol.36
, pp. 143-148
-
-
Sawant, R.B.1
Bharucha, Z.S.2
Rajadhyaksha, S.B.3
-
85
-
-
84940200369
-
Accuracy and use of WHO Hemoglobin Color Scale for diagnosis of anemia among pregnant women by health care providers in periurban settings in Karachi, Pakistan
-
Khan, A.A., Z. Fatmi & M.M. Kadir. 2015. Accuracy and use of WHO Hemoglobin Color Scale for diagnosis of anemia among pregnant women by health care providers in periurban settings in Karachi, Pakistan. Asia Pac. J. Public Health 27: 610–619.
-
(2015)
Asia Pac. J. Public Health
, vol.27
, pp. 610-619
-
-
Khan, A.A.1
Fatmi, Z.2
Kadir, M.M.3
-
86
-
-
84954286829
-
An accurate and inexpensive color-based assay for detecting severe anemia in a limited-resource setting
-
McGann, P.T., E.A. Tyburski, V. de Oliveira, et al. 2015. An accurate and inexpensive color-based assay for detecting severe anemia in a limited-resource setting. Am. J. Hematol. 90: 1122–1127.
-
(2015)
Am. J. Hematol
, vol.90
, pp. 1122-1127
-
-
McGann, P.T.1
Tyburski, E.A.2
de Oliveira, V.3
-
87
-
-
77951138250
-
Capillary and venous haemoglobin levels in blood donors: a 42-month study of 36,258 paired samples
-
Tong, E., W.G. Murphy, A. Kinsella, et al. 2010. Capillary and venous haemoglobin levels in blood donors: a 42-month study of 36,258 paired samples. Vox Sang. 98: 547–553.
-
(2010)
Vox Sang
, vol.98
, pp. 547-553
-
-
Tong, E.1
Murphy, W.G.2
Kinsella, A.3
-
88
-
-
0023821099
-
HemoCue system for hemoglobin measurement. Evaluation in anemic and nonanemic children
-
Cohen, A.R. & J. Seidl-Friedman. 1988. HemoCue system for hemoglobin measurement. Evaluation in anemic and nonanemic children. Am. J. Clin. Pathol. 90: 302–325.
-
(1988)
Am. J. Clin. Pathol.
, vol.90
, pp. 302-325
-
-
Cohen, A.R.1
Seidl-Friedman, J.2
-
89
-
-
0024367057
-
Screening for anaemia: evaluation of a haemoglobinometer
-
Mills, A.F. & N. Meadows. 1989. Screening for anaemia: evaluation of a haemoglobinometer. Arch. Dis. Child. 64: 1468–1471.
-
(1989)
Arch. Dis. Child
, vol.64
, pp. 1468-1471
-
-
Mills, A.F.1
Meadows, N.2
-
90
-
-
0028508075
-
Improved strategy for screening prospective blood donors for anaemia
-
Boulton, F.E., M.J. Nightingale & W. Reynolds. 1994. Improved strategy for screening prospective blood donors for anaemia. Transfus. Med. 4: 221–225.
-
(1994)
Transfus. Med
, vol.4
, pp. 221-225
-
-
Boulton, F.E.1
Nightingale, M.J.2
Reynolds, W.3
-
91
-
-
0028085648
-
An evaluation of the HemoCue for measuring haemoglobin in field studies in Jamaica
-
Hudson-Thomas, M., K.C. Bingham & W.K. Simmons. 1994. An evaluation of the HemoCue for measuring haemoglobin in field studies in Jamaica. Bull. World Health Organ. 72: 423–436.
-
(1994)
Bull. World Health Organ
, vol.72
, pp. 423-436
-
-
Hudson-Thomas, M.1
Bingham, K.C.2
Simmons, W.K.3
-
92
-
-
0029773897
-
Perioperative on-site haemoglobin determination: as accurate as laboratory values?
-
Jaeger, M., T. Ashbury, M. Adams & P. Duncan. 1996. Perioperative on-site haemoglobin determination: as accurate as laboratory values? Can. J. Anaesth. 43: 795–798.
-
(1996)
Can. J. Anaesth
, vol.43
, pp. 795-798
-
-
Jaeger, M.1
Ashbury, T.2
Adams, M.3
Duncan, P.4
-
93
-
-
0030280751
-
Comparative study of bedside and laboratory measurements of hemoglobin
-
Krenzischek, D.A. & F.V. Tanseco. 1996. Comparative study of bedside and laboratory measurements of hemoglobin. Am. J. Crit. Care 5: 427–432.
-
(1996)
Am. J. Crit. Care
, vol.5
, pp. 427-432
-
-
Krenzischek, D.A.1
Tanseco, F.V.2
-
94
-
-
0036245366
-
Evaluation of the HemoCue compared with the Coulter STKS for measurement of neonatal haemoglobin
-
Rechner, I.J., A. Twigg, A.F. Davies & S. Imong. 2002. Evaluation of the HemoCue compared with the Coulter STKS for measurement of neonatal haemoglobin. Arch. Dis. Child. Fetal Neonatal Ed. 86: F188–F189.
-
(2002)
Arch. Dis. Child. Fetal Neonatal Ed
, vol.86
, pp. F188-F189
-
-
Rechner, I.J.1
Twigg, A.2
Davies, A.F.3
Imong, S.4
-
95
-
-
17144364724
-
Utility of point-of-care haemoglobin measurement in the HemoCue-B haemoglobin for the initial diagnosis of anaemia
-
Muñoz, M., A. Romero, J.F. Gómez, et al. 2005. Utility of point-of-care haemoglobin measurement in the HemoCue-B haemoglobin for the initial diagnosis of anaemia. Clin. Lab. Haematol. 27: 99–104.
-
(2005)
Clin. Lab. Haematol
, vol.27
, pp. 99-104
-
-
Muñoz, M.1
Romero, A.2
Gómez, J.F.3
-
96
-
-
33846852614
-
Reliability of HemoCue in patients with gastrointestinal bleeding
-
Van de Louw, A., N. Lasserre, F. Drouhin, et al. 2007. Reliability of HemoCue in patients with gastrointestinal bleeding. Intensive Care Med. 33: 355–358.
-
(2007)
Intensive Care Med
, vol.33
, pp. 355-358
-
-
Van de Louw, A.1
Lasserre, N.2
Drouhin, F.3
-
97
-
-
68749114145
-
Evaluation of a portable hemoglobin photometer in pregnant women in a high altitude area: a pilot study
-
Zhou, X., H. Yan, Y. Xing, et al. 2009. Evaluation of a portable hemoglobin photometer in pregnant women in a high altitude area: a pilot study. BMC Public Health 9: 228.
-
(2009)
BMC Public Health
, vol.9
, pp. 228
-
-
Zhou, X.1
Yan, H.2
Xing, Y.3
-
98
-
-
80052682414
-
Evaluation of a portable hemoglobinometer (HemoCue) to control anemia in hepatitis C liver transplant recipients undergoing antiviral therapy
-
Mariño, Z., J.A. Carrión, J.L. Bedini, et al. 2011. Evaluation of a portable hemoglobinometer (HemoCue) to control anemia in hepatitis C liver transplant recipients undergoing antiviral therapy. Eur. J. Gastroenterol. Hepatol. 23: 942–927.
-
(2011)
Eur. J. Gastroenterol. Hepatol
, vol.23
, pp. 942-927
-
-
Mariño, Z.1
Carrión, J.A.2
Bedini, J.L.3
-
99
-
-
79954594760
-
Hemoglobin estimation by the HemoCue® portable hemoglobin photometer in a resource poor setting
-
Nkrumah, B., S.B. Nguah, N. Sarpong, et al. 2011. Hemoglobin estimation by the HemoCue® portable hemoglobin photometer in a resource poor setting. BMC Clin. Pathol. 11: 5.
-
(2011)
BMC Clin. Pathol
, vol.11
, pp. 5
-
-
Nkrumah, B.1
Nguah, S.B.2
Sarpong, N.3
-
100
-
-
84858600400
-
Comparison of HemoCue® hemoglobin-meter and automated hematology analyzer in measurement of hemoglobin levels in pregnant women at Khartoum hospital, Sudan
-
Adam, I., S. Ahmed, M.H. Mahmoud & M.I. Yassin. 2012. Comparison of HemoCue® hemoglobin-meter and automated hematology analyzer in measurement of hemoglobin levels in pregnant women at Khartoum hospital, Sudan. Diagn. Pathol. 7: 30.
-
(2012)
Diagn. Pathol.
, vol.7
, pp. 30
-
-
Adam, I.1
Ahmed, S.2
Mahmoud, M.H.3
Yassin, M.I.4
-
101
-
-
84880387451
-
Comparison of the accuracy of noninvasive hemoglobin sensor (NBM-200) and portable hemoglobinometer (HemoCue) with an automated hematology analyzer (LH500) in blood donor screening
-
Kim, M.J., Q. Park, M.H. Kim, et al. 2013. Comparison of the accuracy of noninvasive hemoglobin sensor (NBM-200) and portable hemoglobinometer (HemoCue) with an automated hematology analyzer (LH500) in blood donor screening. Ann. Lab. Med. 33: 261–267.
-
(2013)
Ann. Lab. Med
, vol.33
, pp. 261-267
-
-
Kim, M.J.1
Park, Q.2
Kim, M.H.3
-
102
-
-
84888395703
-
Comparison between two portable hemoglobinometers and a reference method to verify the reliability of screening in blood donors
-
Rudolf-Oliveira, R.C., K.T. Gonçalves, M.L. Martignago, et al. 2013. Comparison between two portable hemoglobinometers and a reference method to verify the reliability of screening in blood donors. Transfus. Apher. Sci. 49: 578–582.
-
(2013)
Transfus. Apher. Sci
, vol.49
, pp. 578-582
-
-
Rudolf-Oliveira, R.C.1
Gonçalves, K.T.2
Martignago, M.L.3
-
103
-
-
84882388733
-
Evaluation of the validity of a rapid method for measuring high and low haemoglobin levels in whole blood donors
-
Shahshahani, H.J., N. Meraat & F. Mansouri. 2013. Evaluation of the validity of a rapid method for measuring high and low haemoglobin levels in whole blood donors. Blood Transfus. 11: 385–390.
-
(2013)
Blood Transfus
, vol.11
, pp. 385-390
-
-
Shahshahani, H.J.1
Meraat, N.2
Mansouri, F.3
-
105
-
-
84902651539
-
Assessing diagnostic accuracy of Haemoglobin Colour Scale in real-life setting
-
Shah, P.P., S.A. Desai, D.K. Modi & S.P. Shah. 2014. Assessing diagnostic accuracy of Haemoglobin Colour Scale in real-life setting. J. Health Popul. Nutr. 32: 51–57.
-
(2014)
J. Health Popul. Nutr
, vol.32
, pp. 51-57
-
-
Shah, P.P.1
Desai, S.A.2
Modi, D.K.3
Shah, S.P.4
-
106
-
-
84945314582
-
Comparison of the accuracy of hemoglobin point of care testing using HemoCue and GEM Premier 3000 with automated hematology analyzer in emergency room
-
Zatloukal, J., J. Pouska, J. Kletecka, et al. 2016. Comparison of the accuracy of hemoglobin point of care testing using HemoCue and GEM Premier 3000 with automated hematology analyzer in emergency room. J. Clin. Monit. Comput. 30: 949–956.
-
(2016)
J. Clin. Monit. Comput
, vol.30
, pp. 949-956
-
-
Zatloukal, J.1
Pouska, J.2
Kletecka, J.3
-
107
-
-
84887945134
-
Comparison of haemoglobin measurement methods in the operating theatre
-
Giraud, B., D. Frasca, B. Debaene & O. Mimoz. 2013;. Comparison of haemoglobin measurement methods in the operating theatre. Br. J. Anaesth. 111: 946–954.
-
(2013)
Br. J. Anaesth
, vol.111
, pp. 946-954
-
-
Giraud, B.1
Frasca, D.2
Debaene, B.3
Mimoz, O.4
-
108
-
-
62949240353
-
Anemia screening in potential female blood donors: comparison of two different quantitative methods
-
Mendrone, A. Jr., E.C. Sabino, L. Sampaio, et al. 2009. Anemia screening in potential female blood donors: comparison of two different quantitative methods. Transfusion 49: 662–668.
-
(2009)
Transfusion
, vol.49
, pp. 662-668
-
-
Mendrone, A.1
Sabino, E.C.2
Sampaio, L.3
-
109
-
-
80052177803
-
Comparison of the accuracy of noninvasive hemoglobin monitoring by spectrophotometry (SpHb) and HemoCue® with automated laboratory hemoglobin measurement
-
Lamhaut, L., R. Apriotesei, X. Combes, et al. 2011. Comparison of the accuracy of noninvasive hemoglobin monitoring by spectrophotometry (SpHb) and HemoCue® with automated laboratory hemoglobin measurement. Anesthesiology 115: 548–554.
-
(2011)
Anesthesiology
, vol.115
, pp. 548-554
-
-
Lamhaut, L.1
Apriotesei, R.2
Combes, X.3
-
110
-
-
84863635746
-
Validation and implementation of a new hemoglobinometer for donor screening at Canadian Blood Services
-
Goldman, M., S. Uzicanin, Q.L. Yi, et al. 2012. Validation and implementation of a new hemoglobinometer for donor screening at Canadian Blood Services. Transfusion 52: 1607–1613.
-
(2012)
Transfusion
, vol.52
, pp. 1607-1613
-
-
Goldman, M.1
Uzicanin, S.2
Yi, Q.L.3
-
111
-
-
80052966840
-
Reliability of the HemoCue® hemoglobinometer in critically ill patients: a prospective observational study
-
Mimoz, O., D. Frasca, A. Médard, et al. 2011. Reliability of the HemoCue® hemoglobinometer in critically ill patients: a prospective observational study. Minerva Anestesiol. 77: 979–985.
-
(2011)
Minerva Anestesiol
, vol.77
, pp. 979-985
-
-
Mimoz, O.1
Frasca, D.2
Médard, A.3
-
112
-
-
84880308380
-
Noninvasive methods for haemoglobin screening in prospective blood donors
-
Belardinelli, A., M. Benni, P.L. Tazzari & P. Pagliaro. 2013. Noninvasive methods for haemoglobin screening in prospective blood donors. Vox Sang. 105: 116–120.
-
(2013)
Vox Sang
, vol.105
, pp. 116-120
-
-
Belardinelli, A.1
Benni, M.2
Tazzari, P.L.3
Pagliaro, P.4
-
113
-
-
84982872963
-
Hemoglobin assessment: precision and practicability evaluated in the Netherlands—the HAPPEN study
-
Baart, A.M., W.L. de Kort, K. van den Hurk & P.C. Pasker-de Jong. 2016. Hemoglobin assessment: precision and practicability evaluated in the Netherlands—the HAPPEN study. Transfusion 56: 1984–1993.
-
(2016)
Transfusion
, vol.56
, pp. 1984-1993
-
-
Baart, A.M.1
de Kort, W.L.2
van den Hurk, K.3
Pasker-de Jong, P.C.4
-
114
-
-
84920896721
-
Evaluation of two methods to measure hemoglobin concentration among women with genetic hemoglobin disorders in Cambodia: a method-comparison study
-
Karakochuk, C.D., A. Janmohamed, K.C. Whitfield, et al. 2015. Evaluation of two methods to measure hemoglobin concentration among women with genetic hemoglobin disorders in Cambodia: a method-comparison study. Clin. Chim. Acta 441: 148–155.
-
(2015)
Clin. Chim. Acta
, vol.441
, pp. 148-155
-
-
Karakochuk, C.D.1
Janmohamed, A.2
Whitfield, K.C.3
-
115
-
-
79960699992
-
Determination of capillary hemoglobin levels using the HemoCue system in intensive care patients
-
Seguin, P., A. Kleiber, C. Chanavaz, et al. 2011. Determination of capillary hemoglobin levels using the HemoCue system in intensive care patients. J. Crit. Care 26: 423–427.
-
(2011)
J. Crit. Care
, vol.26
, pp. 423-427
-
-
Seguin, P.1
Kleiber, A.2
Chanavaz, C.3
-
116
-
-
80052968149
-
Accuracy of a continuous noninvasive hemoglobin monitor in intensive care unit patients
-
Frasca, D., C. Dahyot-Fizelier, K. Catherine, et al. 2011. Accuracy of a continuous noninvasive hemoglobin monitor in intensive care unit patients. Crit. Care Med. 39: 2277–2282.
-
(2011)
Crit. Care Med
, vol.39
, pp. 2277-2282
-
-
Frasca, D.1
Dahyot-Fizelier, C.2
Catherine, K.3
-
117
-
-
84959470603
-
The impact of noninvasive, capillary, and venous hemoglobin screening on donor deferrals and the hemoglobin content of red blood cells concentrates: a prospective study
-
Sümnig, A., G. Hron, A. Westphal, et al. 2015. The impact of noninvasive, capillary, and venous hemoglobin screening on donor deferrals and the hemoglobin content of red blood cells concentrates: a prospective study. Transfusion 55: 2847–2854.
-
(2015)
Transfusion
, vol.55
, pp. 2847-2854
-
-
Sümnig, A.1
Hron, G.2
Westphal, A.3
-
118
-
-
84992053110
-
Evaluation of capillary haemoglobin determination for anaemia screening in blood donation settings
-
Daves, M., R. Cemin, E.M. Zagler, et al. 2016. Evaluation of capillary haemoglobin determination for anaemia screening in blood donation settings. Blood Transfus. 14: 387–390.
-
(2016)
Blood Transfus
, vol.14
, pp. 387-390
-
-
Daves, M.1
Cemin, R.2
Zagler, E.M.3
-
119
-
-
85047894504
-
Comparison of haemoglobin assessments by HemoCue and two automated hematology analyzers in young Laotian children
-
Hinnoucho, G.M., M.A. Barffour, K.R. Wessells, et al. 2018. Comparison of haemoglobin assessments by HemoCue and two automated hematology analyzers in young Laotian children. J. Clin. Pathol. 71: 532–538.
-
(2018)
J. Clin. Pathol
, vol.71
, pp. 532-538
-
-
Hinnoucho, G.M.1
Barffour, M.A.2
Wessells, K.R.3
-
120
-
-
0028827014
-
A comparison of four bedside methods of hemoglobin assessment during cardiac surgery
-
McNulty, S.E., M. Torjman, W. Grodecki, et al. 1995. A comparison of four bedside methods of hemoglobin assessment during cardiac surgery. Anesth. Analg. 81: 1197–1202.
-
(1995)
Anesth. Analg
, vol.81
, pp. 1197-1202
-
-
McNulty, S.E.1
Torjman, M.2
Grodecki, W.3
-
121
-
-
84927522128
-
Evaluation of various methods of point-of-care testing of haemoglobin concentration in blood donors
-
Singh, A., A. Dubey, A. Sonker & R. Chaudhary. 2015. Evaluation of various methods of point-of-care testing of haemoglobin concentration in blood donors. Blood Transfus. 13: 233–239.
-
(2015)
Blood Transfus
, vol.13
, pp. 233-239
-
-
Singh, A.1
Dubey, A.2
Sonker, A.3
Chaudhary, R.4
-
122
-
-
84947934800
-
Performance analysis of newly developed point-of-care hemoglobinometer (TrueHb) against an automated hematology analyzer (Sysmex XT 1800i) in terms of precision in hemoglobin measurement
-
Srivastava, A., V. Koul, S.N. Dwivedi, et al. 2015. Performance analysis of newly developed point-of-care hemoglobinometer (TrueHb) against an automated hematology analyzer (Sysmex XT 1800i) in terms of precision in hemoglobin measurement. Int. J. Lab. Hematol. 37: 483–485.
-
(2015)
Int. J. Lab. Hematol
, vol.37
, pp. 483-485
-
-
Srivastava, A.1
Koul, V.2
Dwivedi, S.N.3
-
123
-
-
84945491700
-
Continuous and noninvasive hemoglobin monitoring reduces red blood cell transfusion during neurosurgery: a prospective cohort study
-
Awada, W.N., M.F. Mohmoued, T.M. Radwan, et al. 2015. Continuous and noninvasive hemoglobin monitoring reduces red blood cell transfusion during neurosurgery: a prospective cohort study. J. Clin. Monit. Comput. 29: 733–740.
-
(2015)
J. Clin. Monit. Comput
, vol.29
, pp. 733-740
-
-
Awada, W.N.1
Mohmoued, M.F.2
Radwan, T.M.3
-
124
-
-
84938781858
-
The changes of non-invasive hemoglobin and perfusion index of Pulse CO-Oximetry during induction of general anesthesia
-
Park, S.G., O.H. Lee, Y.H. Park, et al. 2015. The changes of non-invasive hemoglobin and perfusion index of Pulse CO-Oximetry during induction of general anesthesia. Korean J. Anesthesiol. 68: 352–357.
-
(2015)
Korean J. Anesthesiol
, vol.68
, pp. 352-357
-
-
Park, S.G.1
Lee, O.H.2
Park, Y.H.3
-
125
-
-
84925483795
-
Does a non-invasive hemoglobin monitor correlate with a venous blood sample in the acutely ill?
-
von Schweinitz, B.A., R.A. De Lorenzo, P.J. Cuenca, et al. 2015. Does a non-invasive hemoglobin monitor correlate with a venous blood sample in the acutely ill? Intern. Emerg. Med. 10: 55–61.
-
(2015)
Intern. Emerg. Med
, vol.10
, pp. 55-61
-
-
von Schweinitz, B.A.1
De Lorenzo, R.A.2
Cuenca, P.J.3
-
126
-
-
85018983492
-
Accuracy of non-invasive hemoglobin monitoring by pulse CO-oximeter during liver transplantation
-
Erdogan Kayhan, G., Y.Z. Colak, M. Sanli, et al. 2017. Accuracy of non-invasive hemoglobin monitoring by pulse CO-oximeter during liver transplantation. Minerva Anestesiol. 83: 485–492.
-
(2017)
Minerva Anestesiol
, vol.83
, pp. 485-492
-
-
Erdogan Kayhan, G.1
Colak, Y.Z.2
Sanli, M.3
-
127
-
-
85025163423
-
Evaluation of non-invasive hemoglobin monitoring in trauma patients with low hemoglobin levels
-
Gamal, M., B. Abdelhamid, D. Zakaria, et al. 2018. Evaluation of non-invasive hemoglobin monitoring in trauma patients with low hemoglobin levels. Shock 49: 150–153.
-
(2018)
Shock
, vol.49
, pp. 150-153
-
-
Gamal, M.1
Abdelhamid, B.2
Zakaria, D.3
-
128
-
-
84879196822
-
Accuracy of the Masimo Pronto-7® system in patients with left ventricular assist device
-
Bruells, C.S., A.K. Menon, R. Rossaint, et al. 2013. Accuracy of the Masimo Pronto-7® system in patients with left ventricular assist device. J. Cardiothorac. Surg. 8: 159.
-
(2013)
J. Cardiothorac. Surg
, vol.8
, pp. 159
-
-
Bruells, C.S.1
Menon, A.K.2
Rossaint, R.3
-
129
-
-
84855465225
-
Non-invasive measurement of hemoglobin: assessment of two different point-of-care technologies
-
Gayat, E., J. Aulagnier, E. Matthieu, et al. 2012. Non-invasive measurement of hemoglobin: assessment of two different point-of-care technologies. PLoS One 7: e30065.
-
(2012)
PLoS One
, vol.7
-
-
Gayat, E.1
Aulagnier, J.2
Matthieu, E.3
-
130
-
-
84926681222
-
Usefulness of non-invasive spectrophotometric haemoglobin estimation for detecting low haemoglobin levels when compared with a standard laboratory assay for preoperative assessment
-
Khalafallah, A.A., C.R. Chilvers, M. Thomas, et al. 2015. Usefulness of non-invasive spectrophotometric haemoglobin estimation for detecting low haemoglobin levels when compared with a standard laboratory assay for preoperative assessment. Br. J. Anaesth. 144: 669–676.
-
(2015)
Br. J. Anaesth
, vol.144
, pp. 669-676
-
-
Khalafallah, A.A.1
Chilvers, C.R.2
Thomas, M.3
-
131
-
-
84931053744
-
Noninvasive assessment of excessive erythrocytosis as a screening method for chronic mountain sickness at high altitude
-
Vyas, K.J., D. Danz, R.H. Gilman, et al. 2015. Noninvasive assessment of excessive erythrocytosis as a screening method for chronic mountain sickness at high altitude. High Alt. Med. Biol. 16: 162–168.
-
(2015)
High Alt. Med. Biol
, vol.16
, pp. 162-168
-
-
Vyas, K.J.1
Danz, D.2
Gilman, R.H.3
-
132
-
-
85008333289
-
Results of a prospective study evaluating a noninvasive method of hemoglobin adjustment for determining the diffusing capacity of the lung
-
Foster, K.E., R.D. Sahay, N. Zhang & W.D. Hardie. 2017. Results of a prospective study evaluating a noninvasive method of hemoglobin adjustment for determining the diffusing capacity of the lung. Ann. Am. Thorac. Soc. 14: 41–48.
-
(2017)
Ann. Am. Thorac. Soc
, vol.14
, pp. 41-48
-
-
Foster, K.E.1
Sahay, R.D.2
Zhang, N.3
Hardie, W.D.4
-
133
-
-
85011966460
-
Validation of Masimo Pronto 7 and HemoCue 201 for hemoglobin determination in children from 1 to 5 years of age
-
Shamah Levy, T., I. Méndez-Gómez-Humarán, M.D. Morales Ruán, et al. 2017. Validation of Masimo Pronto 7 and HemoCue 201 for hemoglobin determination in children from 1 to 5 years of age. PLoS One 12: e0170990.
-
(2017)
PLoS One
, vol.12
-
-
Shamah Levy, T.1
Méndez-Gómez-Humarán, I.2
Morales Ruán, M.D.3
-
134
-
-
77954231286
-
Spectroscopic noninvasive measurement of hemoglobin compared with capillary and venous values in neonates
-
Rabe, H., R.F. Alvarez, T. Whitfield, et al. 2010. Spectroscopic noninvasive measurement of hemoglobin compared with capillary and venous values in neonates. Neonatology 98: 1–5.
-
(2010)
Neonatology
, vol.98
, pp. 1-5
-
-
Rabe, H.1
Alvarez, R.F.2
Whitfield, T.3
-
135
-
-
84894076310
-
Anaemia: a comprehensive global estimate
-
Pasricha, S.R. 2014. Anaemia: a comprehensive global estimate. Blood 123: 611–612.
-
(2014)
Blood
, vol.123
, pp. 611-612
-
-
Pasricha, S.R.1
-
136
-
-
84961602273
-
Overview of the Biomarkers Reflecting Inflammation and Nutritional Determinants of Anaemia (BRINDA) Project
-
Suchdev, P.S., S.M. Namaste, G.J. Aaron, et al. 2016. Overview of the Biomarkers Reflecting Inflammation and Nutritional Determinants of Anaemia (BRINDA) Project. Adv. Nutr. 7: 349–356.
-
(2016)
Adv. Nutr
, vol.7
, pp. 349-356
-
-
Suchdev, P.S.1
Namaste, S.M.2
Aaron, G.J.3
-
137
-
-
7944233269
-
Combined measurement of ferritin, soluble transferrin receptor, retinol binding protein, and C-reactive protein by an inexpensive, sensitive, and simple sandwich enzyme-linked immunosorbent assay technique
-
Erhardt, J.G., J.E. Estes, C.M. Pfeiffer, et al. 2004. Combined measurement of ferritin, soluble transferrin receptor, retinol binding protein, and C-reactive protein by an inexpensive, sensitive, and simple sandwich enzyme-linked immunosorbent assay technique. J. Nutr. 134: 3127–3132.
-
(2004)
J. Nutr
, vol.134
, pp. 3127-3132
-
-
Erhardt, J.G.1
Estes, J.E.2
Pfeiffer, C.M.3
-
138
-
-
84155189164
-
Accuracy and precision of hemoglobin point-of-care testing during major pediatric surgery
-
Spielmann, N., J. Mauch, C. Madjdpour, et al. 2012. Accuracy and precision of hemoglobin point-of-care testing during major pediatric surgery. Int. J. Lab. Hematol. 34: 86–90.
-
(2012)
Int. J. Lab. Hematol
, vol.34
, pp. 86-90
-
-
Spielmann, N.1
Mauch, J.2
Madjdpour, C.3
-
139
-
-
84892483949
-
Accuracy of noninvasive hemoglobin and invasive point-of-care hemoglobin testing compared with a laboratory analyzer
-
Shah, N., E.A. Osea & G.J. Martinez. 2014. Accuracy of noninvasive hemoglobin and invasive point-of-care hemoglobin testing compared with a laboratory analyzer. Int. J. Lab. Hematol. 36: 56–61.
-
(2014)
Int. J. Lab. Hematol
, vol.36
, pp. 56-61
-
-
Shah, N.1
Osea, E.A.2
Martinez, G.J.3
-
140
-
-
0032973798
-
Precision, accuracy, and reliability of hemoglobin assessment with use of capillary blood
-
Morris, S.S., M.T. Ruel, R.J. Cohen, et al. 1999. Precision, accuracy, and reliability of hemoglobin assessment with use of capillary blood. Am. J. Clin. Nutr. 69: 1243–1248.
-
(1999)
Am. J. Clin. Nutr
, vol.69
, pp. 1243-1248
-
-
Morris, S.S.1
Ruel, M.T.2
Cohen, R.J.3
-
141
-
-
0025143118
-
Rapid assessment of fetal hemoglobin concentration with the HemoCue system
-
Laifer, S.A., J.A. Kuller & L.M. Hill. 1990. Rapid assessment of fetal hemoglobin concentration with the HemoCue system. Obstet. Gynecol. 76: 723–724.
-
(1990)
Obstet. Gynecol
, vol.76
, pp. 723-724
-
-
Laifer, S.A.1
Kuller, J.A.2
Hill, L.M.3
-
142
-
-
0027409329
-
Fetal hemoglobin quantitations using the Hemocue system are rapid and accurate
-
Berry, S.M., M.P. Dombrowski, W.B. Blessed, et al. 1993. Fetal hemoglobin quantitations using the Hemocue system are rapid and accurate. Obstet. Gynecol. 81: 417–420.
-
(1993)
Obstet. Gynecol
, vol.81
, pp. 417-420
-
-
Berry, S.M.1
Dombrowski, M.P.2
Blessed, W.B.3
-
143
-
-
0028473361
-
Hemoglobin screening for normal newborns
-
Herzog, B. & B. Felton. 1994. Hemoglobin screening for normal newborns. J. Perinatol. 14: 285–259.
-
(1994)
J. Perinatol
, vol.14
, pp. 285-259
-
-
Herzog, B.1
Felton, B.2
-
144
-
-
0031595797
-
Evaluation of the HemoCue for measuring intra-operative haemoglobin concentrations: a comparison with the Coulter Max-M
-
Lardi, A.M., C. Hirst, A.J. Mortimer & C.N. McCollum. 1998. Evaluation of the HemoCue for measuring intra-operative haemoglobin concentrations: a comparison with the Coulter Max-M. Anaesthesia 53: 349–352.
-
(1998)
Anaesthesia
, vol.53
, pp. 349-352
-
-
Lardi, A.M.1
Hirst, C.2
Mortimer, A.J.3
McCollum, C.N.4
-
145
-
-
0033205881
-
Utility of HemoCue in estimation of hemoglobin against standard blood cell counter method
-
Prakash, S., U. Kapil, G. Singh, et al. 1999. Utility of HemoCue in estimation of hemoglobin against standard blood cell counter method. J. Assoc. Physicians India 47: 995–997.
-
(1999)
J. Assoc. Physicians India
, vol.47
, pp. 995-997
-
-
Prakash, S.1
Kapil, U.2
Singh, G.3
-
146
-
-
34249830113
-
Evaluation of the utility of the HemoCue 301 haemoglobinometer for blood donor screening
-
Morris, L.D., A. Osei-Bimpong, D. McKeown, et al. 2007. Evaluation of the utility of the HemoCue 301 haemoglobinometer for blood donor screening. Vox Sang. 93: 64–69.
-
(2007)
Vox Sang
, vol.93
, pp. 64-69
-
-
Morris, L.D.1
Osei-Bimpong, A.2
McKeown, D.3
-
147
-
-
84942257824
-
Evaluation of the diagnostic accuracy of the HemoCue device for detecting anaemia in healthy school-aged children in KwaZulu-Natal, South Africa
-
Gwetu, T.P. & M.K. Chhagan. 2015. Evaluation of the diagnostic accuracy of the HemoCue device for detecting anaemia in healthy school-aged children in KwaZulu-Natal, South Africa. S. Afr. Med. J. 105: 596–599.
-
(2015)
S. Afr. Med. J.
, vol.105
, pp. 596-599
-
-
Gwetu, T.P.1
Chhagan, M.K.2
-
148
-
-
85067021785
-
-
Accessed October 25, 2018
-
Centers for Disease Control and Prevention (CDC). Micronutrient survey manual. 2017. Accessed October 25, 2018. http://surveytoolkit.micronutrient.org/.
-
(2017)
Micronutrient survey manual
-
-
-
149
-
-
85067037797
-
-
Accessed October 25, 2018
-
Centers for Disease Control and Prevention (CDC). Micronutrient survey toolkit. 2016. Accessed October 25, 2018. http://surveytoolkit.micronutrient.org/.
-
(2016)
Micronutrient survey toolkit
-
-
-
150
-
-
0022898207
-
Evaluation of “HemoCue,” a new device for determining hemoglobin
-
von Schenck, H., M. Falkensson & B. Lundberg. 1986. Evaluation of “HemoCue,” a new device for determining hemoglobin. Clin. Chem. 32: 526–529.
-
(1986)
Clin. Chem
, vol.32
, pp. 526-529
-
-
von Schenck, H.1
Falkensson, M.2
Lundberg, B.3
-
153
-
-
0031263071
-
Blood donor rejection rate: hemoCue hemoglobin analyzer vs. microhematocrit
-
Russell, B.L. & S.M. Martin. 1997. Blood donor rejection rate: hemoCue hemoglobin analyzer vs. microhematocrit. Clin. Lab. Sci. 10: 321–324.
-
(1997)
Clin. Lab. Sci
, vol.10
, pp. 321-324
-
-
Russell, B.L.1
Martin, S.M.2
-
154
-
-
0034114063
-
Field trial of a haemoglobin colour scale: an effective tool to detect anaemia in preschool children
-
Montresor, A., M. Albonico, N. Khalfan, et al. 2000. Field trial of a haemoglobin colour scale: an effective tool to detect anaemia in preschool children. Trop. Med. Int. Health 5: 129–133.
-
(2000)
Trop. Med. Int. Health
, vol.5
, pp. 129-133
-
-
Montresor, A.1
Albonico, M.2
Khalfan, N.3
-
155
-
-
0036485122
-
Evaluation of the HemoCue plasma haemoglobin analyser for assessing haemolysis in red cell concentrates during storage
-
Cardigan, R. & K. Smith. 2002. Evaluation of the HemoCue plasma haemoglobin analyser for assessing haemolysis in red cell concentrates during storage. Vox Sang. 82: 76–79.
-
(2002)
Vox Sang
, vol.82
, pp. 76-79
-
-
Cardigan, R.1
Smith, K.2
-
156
-
-
0036171692
-
Taking a medical history and using a colour scale during clinical examination of pallor improves detection of anaemia
-
Chowdhury, M.E., V. Chongsuvivatwong, A.F. Geater, et al. 2002. Taking a medical history and using a colour scale during clinical examination of pallor improves detection of anaemia. Trop. Med. Int. Health 7: 133–139.
-
(2002)
Trop. Med. Int. Health
, vol.7
, pp. 133-139
-
-
Chowdhury, M.E.1
Chongsuvivatwong, V.2
Geater, A.F.3
-
157
-
-
0036676660
-
Comparison of HemoCue method with cyanmethemoglobin method for estimation of hemoglobin
-
Kapoor, S.K., U. Kapil, S.N. Dwivedi, et al. 2002. Comparison of HemoCue method with cyanmethemoglobin method for estimation of hemoglobin. Indian Pediatr. 39: 743–746.
-
(2002)
Indian Pediatr
, vol.39
, pp. 743-746
-
-
Kapoor, S.K.1
Kapil, U.2
Dwivedi, S.N.3
-
158
-
-
0036032843
-
Evaluation of the Haemoglobin Colour Scale and comparison with the HemoCue haemoglobin assay
-
Paddle, J.J. 2002. Evaluation of the Haemoglobin Colour Scale and comparison with the HemoCue haemoglobin assay. Bull. World Health Organ. 80: 813–816.
-
(2002)
Bull. World Health Organ
, vol.80
, pp. 813-816
-
-
Paddle, J.J.1
-
160
-
-
0038574482
-
Performance of the Haemoglobin Colour Scale in diagnosing severe and very severe anaemia
-
Montresor, A., M. Ramsan, N. Khalfan, et al. 2003. Performance of the Haemoglobin Colour Scale in diagnosing severe and very severe anaemia. Trop. Med. Int. Health 8: 619–624.
-
(2003)
Trop. Med. Int. Health
, vol.8
, pp. 619-624
-
-
Montresor, A.1
Ramsan, M.2
Khalfan, N.3
-
162
-
-
33750375205
-
Evaluation of the WHO Haemoglobin Colour Scale for diagnosis of anaemia in children and pregnant women as used by primary health care nurses and community health workers in western Kenya
-
Lindblade, K.A., K. Mwololo, A.M. van Eijk, et al. 2006. Evaluation of the WHO Haemoglobin Colour Scale for diagnosis of anaemia in children and pregnant women as used by primary health care nurses and community health workers in western Kenya. Trop. Med. Int. Health 11: 1679–1687.
-
(2006)
Trop. Med. Int. Health
, vol.11
, pp. 1679-1687
-
-
Lindblade, K.A.1
Mwololo, K.2
van Eijk, A.M.3
-
163
-
-
58449107140
-
HemoCue photometer: a better alternative of hemoglobin estimation in blood donors?
-
Akhtar, K., R.K. Sherwani, K. Rahman, et al. 2008. HemoCue photometer: a better alternative of hemoglobin estimation in blood donors? Indian J. Hematol. Blood Transfus. 24: 170–172.
-
(2008)
Indian J. Hematol. Blood Transfus
, vol.24
, pp. 170-172
-
-
Akhtar, K.1
Sherwani, R.K.2
Rahman, K.3
-
164
-
-
58549088363
-
Evaluation of WHO haemoglobin colour scale & palmar pallor for screening of anaemia among children (6–35 months) in rural Wardha, India
-
Sinha, N., P.R. Deshmukh & B.S. Garg. 2008. Evaluation of WHO haemoglobin colour scale & palmar pallor for screening of anaemia among children (6–35 months) in rural Wardha, India. Indian J. Med. Res. 128: 278–281.
-
(2008)
Indian J. Med. Res.
, vol.128
, pp. 278-281
-
-
Sinha, N.1
Deshmukh, P.R.2
Garg, B.S.3
-
165
-
-
84859008324
-
Evaluation of the diagnostic accuracy of the Haemoglobin Colour Scale to detect anaemia in young children attending primary healthcare clinics in Zanzibar
-
Aldridge, C., H.M. Foster, M. Albonico, et al. 2012. Evaluation of the diagnostic accuracy of the Haemoglobin Colour Scale to detect anaemia in young children attending primary healthcare clinics in Zanzibar. Trop. Med. Int. Health 17: 423–429.
-
(2012)
Trop. Med. Int. Health
, vol.17
, pp. 423-429
-
-
Aldridge, C.1
Foster, H.M.2
Albonico, M.3
-
166
-
-
84906482950
-
Validation of the haemoglobin colour scale for screening blood donors in Malawi
-
M'baya, B., I. Mbingwani, L. Mgawi, et al. 2014. Validation of the haemoglobin colour scale for screening blood donors in Malawi. Malawi Med. J. 26: 30–33.
-
(2014)
Malawi Med. J
, vol.26
, pp. 30-33
-
-
M'baya, B.1
Mbingwani, I.2
Mgawi, L.3
-
167
-
-
85014129653
-
Comparison of haemoglobin estimates using direct & indirect cyanmethaemoglobin methods
-
Bansal, P.G., G.S. Toteja, N. Bhatia, et al. 2016. Comparison of haemoglobin estimates using direct & indirect cyanmethaemoglobin methods. Indian J. Med. Res. 144: 566–571.
-
(2016)
Indian J. Med. Res
, vol.144
, pp. 566-571
-
-
Bansal, P.G.1
Toteja, G.S.2
Bhatia, N.3
-
168
-
-
84950303206
-
Accuracy of non-invasive continuous total hemoglobin measurement by Pulse CO-Oximetry in severe traumatized and surgical bleeding patients
-
Baulig, W., B. Seifert, D.R. Spahn & O.M. Theusinger. 2017. Accuracy of non-invasive continuous total hemoglobin measurement by Pulse CO-Oximetry in severe traumatized and surgical bleeding patients. J. Clin. Monit. Comput. 31: 177–185.
-
(2017)
J. Clin. Monit. Comput
, vol.31
, pp. 177-185
-
-
Baulig, W.1
Seifert, B.2
Spahn, D.R.3
Theusinger, O.M.4
-
169
-
-
0034955316
-
Estimating the prevalence of anaemia: a comparison of three methods
-
Sari, M., S. de Pee, E. Martini, et al. 2001. Estimating the prevalence of anaemia: a comparison of three methods. Bull. World Health Organ. 79: 506–511.
-
(2001)
Bull. World Health Organ
, vol.79
, pp. 506-511
-
-
Sari, M.1
de Pee, S.2
Martini, E.3
-
171
-
-
85067050366
-
-
CLIA requirements for analytical quality., Accessed October 25, 2018
-
Westgard. CLIA requirements for analytical quality. Westgard. Accessed October 25, 2018. https://www.westgard.com/clia.htm.
-
Westgard
-
-
-
173
-
-
0031283092
-
Hemocue, an accurate bedside method of hemoglobin measurement?
-
Rippmann, C.E., P.C. Nett, D. Popovic, et al. 1997. Hemocue, an accurate bedside method of hemoglobin measurement? J. Clin. Monit.13: 373–377.
-
(1997)
J. Clin. Monit
, vol.13
, pp. 373-377
-
-
Rippmann, C.E.1
Nett, P.C.2
Popovic, D.3
|