메뉴 건너뛰기




Volumn 8, Issue , 2017, Pages 75-88

Techniques used for the screening of hemoglobin levels in blood donors: Current insights and future directions

Author keywords

Blood donors; Copper sulfate method; Cut off criteria; Hemoglobin estimation; Noninvasive spectrophotometry; Portable hemoglobinometers; Pre analytical variables

Indexed keywords

BIODIVERSITY; BLOOD DONOR; BLOOD SAMPLING; BODY POSITION; CAPILLARY BLOOD; COPPER SULFATE GRAVIMETRIC METHOD; CYANMETHEMOGLOBIN METHOD; HEMATOLOGY ANALYZER; HEMODILUTION; HEMOGLOBIN BLOOD LEVEL; HEMOGLOBIN COLOR SCALE; HUMAN; MEASUREMENT ACCURACY; MEASUREMENT PRECISION; PREDICTIVE VALUE; REVIEW; SCREENING TEST; SENSITIVITY AND SPECIFICITY; SPECTROPHOTOMETRY; SPUN MICROHEMATOCRIT; VEIN PUNCTURE;

EID: 85026452931     PISSN: None     EISSN: 11792736     Source Type: Journal    
DOI: 10.2147/JBM.S103788     Document Type: Review
Times cited : (43)

References (72)
  • 1
    • 0025312951 scopus 로고
    • Heterogeneity of common hematologic parameters among racial, ethnic and gender subgroups
    • Saxena S, Wong ET. Heterogeneity of common hematologic parameters among racial, ethnic and gender subgroups. Arch Pathol Lab Med. 1990;114(4):715-719.
    • (1990) Arch Pathol Lab Med , vol.114 , Issue.4 , pp. 715-719
    • Saxena, S.1    Wong, E.T.2
  • 2
    • 22144438628 scopus 로고    scopus 로고
    • Hemoglobin screening in prospective blood donors: Comparison of different blood samples and different quantitative methods
    • Radtke H, Polat G, Kalus U, Salama A, Kiesewetter H. Hemoglobin screening in prospective blood donors: comparison of different blood samples and different quantitative methods. Transfus Apher Sci. 2005;33(1):31-35.
    • (2005) Transfus Apher Sci , vol.33 , Issue.1 , pp. 31-35
    • Radtke, H.1    Polat, G.2    Kalus, U.3    Salama, A.4    Kiesewetter, H.5
  • 3
    • 85026449696 scopus 로고    scopus 로고
    • United States Code of Federal Regulations, Title 21, 640.3 (b) (3)
    • United States Code of Federal Regulations, Title 21, 640.3 (b) (3).
  • 7
    • 85026451989 scopus 로고    scopus 로고
    • Accessed June 2, 2017
    • Japanese Red Cross Society. Blood Services 2016. Available from: http://www.bpro.or.jp/english/pdf_annual/BPRO2001.pdf. Accessed June 2, 2017.
    • (2016) Blood Services
  • 8
    • 85026490461 scopus 로고    scopus 로고
    • Portaria no. 1.353, de 13 de junho de 2011. Aprova o RegulamentoTecnico de ProcedimentosHemoterapicos. Brasilia, DF: DiarioOficial da Uniao
    • Ministerio da Saude. Gabinete do Ministro. Portaria no. 1.353, de 13 de junho de 2011. Aprova o RegulamentoTecnico de ProcedimentosHemoterapicos. Brasilia, DF: DiarioOficial da Uniao; 2011.
    • (2011) Gabinete Do Ministro
  • 9
    • 85026449190 scopus 로고    scopus 로고
    • The Drugs and Cosmetics Act 1940 and the Drugs and Cosmetics Rules 1945, Amendment upto September 30
    • The Drugs and Cosmetics Act 1940 and the Drugs and Cosmetics Rules 1945, Amendment upto September 30, 1999.
    • (1999)
  • 10
    • 84876731478 scopus 로고    scopus 로고
    • Capillary versus venous haemoglobin determination in the assessment of healthy blood donors
    • Patel AJ, Wesley R, Leitman SF, Bryant BJ. Capillary versus venous haemoglobin determination in the assessment of healthy blood donors. Vox Sang. 2013;104(4):317-323.
    • (2013) Vox Sang , vol.104 , Issue.4 , pp. 317-323
    • Patel, A.J.1    Wesley, R.2    Leitman, S.F.3    Bryant, B.J.4
  • 11
    • 78650544509 scopus 로고
    • Blood from the ear lobe; preliminary reports
    • Bruckmann G. Blood from the ear lobe; preliminary reports. J Lab Clin Med. 1942;27:487.
    • (1942) J Lab Clin Med , vol.27 , pp. 487
    • Bruckmann, G.1
  • 12
    • 84924923754 scopus 로고
    • Fortuitous factors affecting the leucocyte count in blood from the ear
    • Lucy HC. Fortuitous factors affecting the leucocyte count in blood from the ear. J Clin Pathol. 1950;3:146-151.
    • (1950) J Clin Pathol , vol.3 , pp. 146-151
    • Lucy, H.C.1
  • 13
    • 0017682341 scopus 로고
    • Hemoglobin screening in prospective blood donors: A comparison of methods
    • Avoy DR, Canuel ML, Otton BM, Mileski EB. Hemoglobin screening in prospective blood donors: a comparison of methods. Transfusion. 1977;17(3):261-264.
    • (1977) Transfusion , vol.17 , Issue.3 , pp. 261-264
    • Avoy, D.R.1    Canuel, M.L.2    Otton, B.M.3    Mileski, E.B.4
  • 14
    • 0035078852 scopus 로고    scopus 로고
    • Accuracy of predonation Hct sampling affects donor safety, eligibility, and deferral rates
    • Wood EM, Kim DM, Miller JP. Accuracy of predonation Hct sampling affects donor safety, eligibility, and deferral rates. Transfusion. 2001;41(3):353-359.
    • (2001) Transfusion , vol.41 , Issue.3 , pp. 353-359
    • Wood, E.M.1    Kim, D.M.2    Miller, J.P.3
  • 15
    • 0017647452 scopus 로고
    • Unacceptable variability of hemoglobin estimation on samples obtained from ear punctures
    • Coburn TJ, Miller WV, Parrill WD. Unacceptable variability of hemoglobin estimation on samples obtained from ear punctures. Transfusion. 1977;17(3):265-268.
    • (1977) Transfusion , vol.17 , Issue.3 , pp. 265-268
    • Coburn, T.J.1    Miller, W.V.2    Parrill, W.D.3
  • 16
    • 0028158273 scopus 로고
    • Reappraisal of optimal hemoglobin standards for female blood donors in Canada
    • Pi DW, Krikler SH, Sparling TG, Carter CJ, Wadsworth LD. Reappraisal of optimal hemoglobin standards for female blood donors in Canada. Transfusion. 1994;31(1):7-10.
    • (1994) Transfusion , vol.31 , Issue.1 , pp. 7-10
    • Pi, D.W.1    Krikler, S.H.2    Sparling, T.G.3    Carter, C.J.4    Wadsworth, L.D.5
  • 17
    • 39049085682 scopus 로고    scopus 로고
    • The capillary haemoglobin level is a more physiological measure than the venous level and is less susceptible to seasonal fluctuation when the donor haemoglobin level is close to the regulatory cut-off
    • Darragh E, McSweeney E, Ekin C, Kinsella A, Murphy WG. The capillary haemoglobin level is a more physiological measure than the venous level and is less susceptible to seasonal fluctuation when the donor haemoglobin level is close to the regulatory cut-off. Transfus Med. 2006;16(s1):13-14.
    • (2006) Transfus Med , vol.16 , Issue.s1 , pp. 13-14
    • Darragh, E.1    McSweeney, E.2    Ekin, C.3    Kinsella, A.4    Murphy, W.G.5
  • 19
    • 83555174543 scopus 로고    scopus 로고
    • Reliability of capillary hemoglobin screening under routine conditions
    • Ziemann M, Lizardo B, Geusendam G, Schlenke P. Reliability of capillary hemoglobin screening under routine conditions. Transfusion. 2011;51(12):2714-2719.
    • (2011) Transfusion , vol.51 , Issue.12 , pp. 2714-2719
    • Ziemann, M.1    Lizardo, B.2    Geusendam, G.3    Schlenke, P.4
  • 20
    • 84888395703 scopus 로고    scopus 로고
    • Comparison between two portable hemoglobinometers and a reference method to verify the reliability of screening in blood donors
    • Rudolf-Oliveira RC, Gonçalves KT, Martignago ML, et al. Comparison between two portable hemoglobinometers and a reference method to verify the reliability of screening in blood donors. Transfus Apher Sci. 2013;49(3):578-582.
    • (2013) Transfus Apher Sci , vol.49 , Issue.3 , pp. 578-582
    • Rudolf-Oliveira, R.C.1    Gonçalves, K.T.2    Martignago, M.L.3
  • 21
    • 84927522128 scopus 로고    scopus 로고
    • Evaluation of various methods of point-of-care testing of haemoglobin concentration in blood donors
    • Singh A, Dubey A, Sonker A, Chaudhary R. Evaluation of various methods of point-of-care testing of haemoglobin concentration in blood donors. Blood Transfus. 2015;13(2):233-239.
    • (2015) Blood Transfus , vol.13 , Issue.2 , pp. 233-239
    • Singh, A.1    Dubey, A.2    Sonker, A.3    Chaudhary, R.4
  • 22
    • 0022638746 scopus 로고
    • Evaluation of haemoglobin screening methods in prospective blood donors
    • Ross DG, Gillfillan AC, Housten DE, Heaton WA. Evaluation of haemoglobin screening methods in prospective blood donors. Vox Sang. 1986;50(2):78-80.
    • (1986) Vox Sang , vol.50 , Issue.2 , pp. 78-80
    • Ross, D.G.1    Gillfillan, A.C.2    Housten, D.E.3    Heaton, W.A.4
  • 23
    • 62949240353 scopus 로고    scopus 로고
    • Anemia screening in potential female blood donors: Comparison of two different quantitative methods
    • Mendrone A, Sabino EC, Sampaio L, et al. Anemia screening in potential female blood donors: comparison of two different quantitative methods. Transfusion. 2009;49(4):662-668.
    • (2009) Transfusion , vol.49 , Issue.4 , pp. 662-668
    • Mendrone, A.1    Sabino, E.C.2    Sampaio, L.3
  • 24
    • 77958154549 scopus 로고    scopus 로고
    • Estimation of hemoglobin in blood donors: A comparative study using hemocue and cell counter
    • Bahadur S, Jain S, Jain M. Estimation of hemoglobin in blood donors: a comparative study using hemocue and cell counter. Transfus Apher Sci. 2010;43(2):155-157.
    • (2010) Transfus Apher Sci , vol.43 , Issue.2 , pp. 155-157
    • Bahadur, S.1    Jain, S.2    Jain, M.3
  • 25
    • 0023792468 scopus 로고
    • A comparison between haematological parameters in ‘capillary’ and venous blood from healthy adults
    • Daae LN, Halvorsen S, Mathisen PM, Mironska K. A comparison between haematological parameters in ‘capillary’ and venous blood from healthy adults. Scand J Clin Lab Invest. 1988;48:723-726.
    • (1988) Scand J Clin Lab Invest , vol.48 , pp. 723-726
    • Daae, L.N.1    Halvorsen, S.2    Mathisen, P.M.3    Mironska, K.4
  • 26
    • 18244408525 scopus 로고    scopus 로고
    • Postural pseudoanemia: Posturedependent change in hematocrit
    • Jacob G, Raj SR, Keitch T, et al. Postural pseudoanemia: posturedependent change in hematocrit. Mayo Clin Proc. 2005;80(5):611-614.
    • (2005) Mayo Clin Proc , vol.80 , Issue.5 , pp. 611-614
    • Jacob, G.1    Raj, S.R.2    Keitch, T.3
  • 27
    • 77951138250 scopus 로고    scopus 로고
    • Capillary and venous haemoglobin levels in blood donors: A 42-month study of 36 258 paired samples
    • Tong E, Murphy WG, Kinsella A, et al. Capillary and venous haemoglobin levels in blood donors: a 42-month study of 36 258 paired samples. Vox Sang. 2010;98(4):547-553.
    • (2010) Vox Sang , vol.98 , Issue.4 , pp. 547-553
    • Tong, E.1    Murphy, W.G.2    Kinsella, A.3
  • 28
    • 84923111991 scopus 로고    scopus 로고
    • Comparison of three noninvasive methods for haemoglobin screening of blood donors
    • Ardin S, Störmer M, Radojska S, Oustianskaia L, Hahn M, Gathof BS. Comparison of three noninvasive methods for haemoglobin screening of blood donors. Transfusion. 2015;55(2):379-387.
    • (2015) Transfusion , vol.55 , Issue.2 , pp. 379-387
    • Ardin, S.1    Störmer, M.2    Radojska, S.3    Oustianskaia, L.4    Hahn, M.5    Gathof, B.S.6
  • 29
    • 84861101245 scopus 로고    scopus 로고
    • NHLBI Retrovirus Epidemiology Donor Study-II (REDS-II). The difference between fingerstick and venous hemoglobin and hematocrit varies by sex and iron stores
    • Cable RG, Steele WR, Melmed RS, et al; NHLBI Retrovirus Epidemiology Donor Study-II (REDS-II). The difference between fingerstick and venous hemoglobin and hematocrit varies by sex and iron stores. Transfusion. 2012;52(5):1031-1040.
    • (2012) Transfusion , vol.52 , Issue.5 , pp. 1031-1040
    • Cable, R.G.1    Steele, W.R.2    Melmed, R.S.3
  • 30
    • 0001719183 scopus 로고
    • Effect of posture and position of the venous sampling site on the hematocrit and serum protein concentration
    • Eisenberg S. Effect of posture and position of the venous sampling site on the hematocrit and serum protein concentration. J Lab Clin Med. 1963;61:755-760.
    • (1963) J Lab Clin Med , vol.61 , pp. 755-760
    • Eisenberg, S.1
  • 31
    • 0028508075 scopus 로고
    • Improved strategy for screening prospective blood donors for anaemia
    • Boulton FE, Nightingale MJ, Reynolds W. Improved strategy for screening prospective blood donors for anaemia. Transfus Med. 1994;4(3):221-225.
    • (1994) Transfus Med , vol.4 , Issue.3 , pp. 221-225
    • Boulton, F.E.1    Nightingale, M.J.2    Reynolds, W.3
  • 32
    • 0037261653 scopus 로고    scopus 로고
    • Haematocrit: Within-subject and seasonal variation
    • Thirup P. Haematocrit: within-subject and seasonal variation. Sports Med. 2003;33(3):231-243.
    • (2003) Sports Med , vol.33 , Issue.3 , pp. 231-243
    • Thirup, P.1
  • 33
    • 0037346345 scopus 로고    scopus 로고
    • Hb screening of blood donors: How close is close enough?
    • Cable RG. Hb screening of blood donors: how close is close enough? Transfusion. 2003;43(3):306-308.
    • (2003) Transfusion , vol.43 , Issue.3 , pp. 306-308
    • Cable, R.G.1
  • 34
    • 0014153086 scopus 로고
    • Hemoglobin and hematocrit values of blood donors
    • Keating LJ, Gorman R, Moore R. Hemoglobin and hematocrit values of blood donors. Transfusion. 1967;7(6):420-424.
    • (1967) Transfusion , vol.7 , Issue.6 , pp. 420-424
    • Keating, L.J.1    Gorman, R.2    Moore, R.3
  • 35
    • 75549098988 scopus 로고
    • The determination of hemoglobin in blood banks
    • Pirofsky B, Nelson HM. The determination of hemoglobin in blood banks. Transfusion. 1964;4:45-49.
    • (1964) Transfusion , vol.4 , pp. 45-49
    • Pirofsky, B.1    Nelson, H.M.2
  • 36
    • 80053639020 scopus 로고    scopus 로고
    • Quality evaluation of four hemoglobin screening methods in a blood donor setting along with their comparative cost analysis in an Indian scenario
    • Tondon R, Verma A, Pandey P, Chaudhary R. Quality evaluation of four hemoglobin screening methods in a blood donor setting along with their comparative cost analysis in an Indian scenario. Asian J Transfus Sci. 2009;3(2):66-69.
    • (2009) Asian J Transfus Sci , vol.3 , Issue.2 , pp. 66-69
    • Tondon, R.1    Verma, A.2    Pandey, P.3    Chaudhary, R.4
  • 37
    • 0012513305 scopus 로고
    • Copper sulfate screening of blood donors: Report of a donor passing the test with less than eight grams of hemoglobin
    • Mannarino AD, MacPherson AR. Copper sulfate screening of blood donors: report of a donor passing the test with less than eight grams of hemoglobin. Transfusion. 1963;3:398-400.
    • (1963) Transfusion , vol.3 , pp. 398-400
    • Mannarino, A.D.1    Macpherson, A.R.2
  • 38
    • 0014151413 scopus 로고
    • The microhematocrit test as a method for evaluating deferment by copper sulfate
    • Kliman A. The microhematocrit test as a method for evaluating deferment by copper sulfate. Transfusion. 1967;7(6):425-431.
    • (1967) Transfusion , vol.7 , Issue.6 , pp. 425-431
    • Kliman, A.1
  • 40
    • 0020658661 scopus 로고
    • Rejection of prospective blood donors due to systematic errors in hematocrit measurement
    • Ross DG, Ross WB, Schreiner DE, Heaton WA. Rejection of prospective blood donors due to systematic errors in hematocrit measurement. Transfusion. 1983;23(1):75-77.
    • (1983) Transfusion , vol.23 , Issue.1 , pp. 75-77
    • Ross, D.G.1    Ross, W.B.2    Schreiner, D.E.3    Heaton, W.A.4
  • 41
    • 0026182606 scopus 로고
    • Comparison of conductivity measured haematocrit to microhematocrit
    • Gotch F, Torres L, Evans M, et al. Comparison of conductivity measured haematocrit to microhematocrit. Am Soc Artif Intern Organs Trans. 1991;37(3):138-139.
    • (1991) Am Soc Artif Intern Organs Trans , vol.37 , Issue.3 , pp. 138-139
    • Gotch, F.1    Torres, L.2    Evans, M.3
  • 42
    • 0022597579 scopus 로고
    • The effect of capillary tube diameter on microhematocrit value
    • Solomon HM, Grindon AJ. The effect of capillary tube diameter on microhematocrit value. Transfusion. 1986;26(2):199-202.
    • (1986) Transfusion , vol.26 , Issue.2 , pp. 199-202
    • Solomon, H.M.1    Grindon, A.J.2
  • 44
    • 73849178537 scopus 로고
    • Standards for rejection of blood donors: A comparison of CuSO, specific gravity, microhematocrit and electronic hematocrit values with hemoglobin values by the cyanmethemoglobin technic
    • Perkins HA, Torg B. Standards for rejection of blood donors: a comparison of CuSO, specific gravity, microhematocrit and electronic hematocrit values with hemoglobin values by the cyanmethemoglobin technic. Transfusion. 1962;2:392-397.
    • (1962) Transfusion , vol.2 , pp. 392-397
    • Perkins, H.A.1    Torg, B.2
  • 45
    • 0029052546 scopus 로고
    • A simple and reliable method for estimating haemoglobin
    • Stott GJ, Lewis SM. A simple and reliable method for estimating haemoglobin. Bull World Health Organ. 1995;73(3):369-373.
    • (1995) Bull World Health Organ , vol.73 , Issue.3 , pp. 369-373
    • Stott, G.J.1    Lewis, S.M.2
  • 46
    • 33750375205 scopus 로고    scopus 로고
    • Evaluation of the WHO Haemoglobin Colour Scale for diagnosis of anaemia in children and pregnant women as used by primary health care nurses and community health workers in western Kenya
    • Lindblade KA, Mwololo K, van Eijk AM, et al. Evaluation of the WHO Haemoglobin Colour Scale for diagnosis of anaemia in children and pregnant women as used by primary health care nurses and community health workers in western Kenya. Trop Med Int Health. 2006;11(11):1679-1687.
    • (2006) Trop Med Int Health , vol.11 , Issue.11 , pp. 1679-1687
    • Lindblade, K.A.1    Mwololo, K.2    Van Eijk, A.M.3
  • 47
    • 84859008324 scopus 로고    scopus 로고
    • Evaluation of the diagnostic accuracy of the Haemoglobin Colour Scale to detect anaemia in young children attending primary healthcare clinics in Zanzibar
    • Aldridge C, Foster HM, Albonico M, Ame SM, Montresor A. Evaluation of the diagnostic accuracy of the Haemoglobin Colour Scale to detect anaemia in young children attending primary healthcare clinics in Zanzibar. Trop Med Int Health. 2012;17(4):423-429.
    • (2012) Trop Med Int Health , vol.17 , Issue.4 , pp. 423-429
    • Aldridge, C.1    Foster, H.M.2    Albonico, M.3    Ame, S.M.4    Montresor, A.5
  • 48
    • 84864073792 scopus 로고    scopus 로고
    • Validity of hemoglobincolor scale in blood donor screening based on Standard Operating Procedures of Iranian Blood Transfusion Organization
    • Shahshahani HJ, Amiri F. Validity of hemoglobincolor scale in blood donor screening based on Standard Operating Procedures of Iranian Blood Transfusion Organization. Sci J Blood Transfus Organ. 2009;5(4):281-286.
    • (2009) Sci J Blood Transfus Organ , vol.5 , Issue.4 , pp. 281-286
    • Shahshahani, H.J.1    Amiri, F.2
  • 49
    • 0036032843 scopus 로고    scopus 로고
    • Evaluation of the Haemoglobin colour Scale and comparison with the HemoCue haemoglobin assay
    • Paddle JJ. Evaluation of the Haemoglobin colour Scale and comparison with the HemoCue haemoglobin assay. Bull World Health Organ. 2002;80(10):813-816.
    • (2002) Bull World Health Organ , vol.80 , Issue.10 , pp. 813-816
    • Paddle, J.J.1
  • 50
    • 0013870275 scopus 로고
    • Haemoglobin estimation: A comparison of different techniques
    • Elwood PC, Jacobs A. Haemoglobin estimation: a comparison of different techniques. Br Med J. 1966;1(5478):20-24.
    • (1966) Br Med J , vol.1 , Issue.5478 , pp. 20-24
    • Elwood, P.C.1    Jacobs, A.2
  • 51
    • 85026489454 scopus 로고
    • Abbott Park, IL: Abbott Diagnostics
    • Abbott Diagnostics. Operations Manual, Cell-Dyn 1700 System. Abbott Park, IL: Abbott Diagnostics; 1995.
    • (1995) Operations Manual, Cell-Dyn 1700 System
  • 52
    • 0020380220 scopus 로고
    • New method for hemoglobin determination by using sodium lauryl sulfate (SLS)
    • Oshiro I, Takenaka T, Maeda J. New method for hemoglobin determination by using sodium lauryl sulfate (SLS). Clin Biochem. 1982;15(2):83-88.
    • (1982) Clin Biochem , vol.15 , Issue.2 , pp. 83-88
    • Oshiro, I.1    Takenaka, T.2    Maeda, J.3
  • 53
    • 85026487243 scopus 로고    scopus 로고
    • HemoCue AB[homepage on the Internet], Accessed November 19, 2016
    • HemoCue AB [homepage on the Internet]. Available from: www.hemocue.com. Accessed November 19, 2016.
  • 54
    • 0023182451 scopus 로고
    • Evaluation of portable haemoglobinometer in general practice
    • Neville RG. Evaluation of portable haemoglobinometer in general practice. BMJ (Clin Res Ed). 1987;294(6582):1263-1265.
    • (1987) BMJ (Clin Res Ed) , vol.294 , Issue.6582 , pp. 1263-1265
    • Neville, R.G.1
  • 55
    • 34249830113 scopus 로고    scopus 로고
    • Evaluation of the utility of the HemoCue 301 haemoglobinometer for blood donor screening
    • Morris LD, Osei-Bimpong A, McKeown D, Roper D, Lewis SM. Evaluation of the utility of the HemoCue 301 haemoglobinometer for blood donor screening. Vox Sang. 2007;93(1):64-69.
    • (2007) Vox Sang , vol.93 , Issue.1 , pp. 64-69
    • Morris, L.D.1    Osei-Bimpong, A.2    McKeown, D.3    Roper, D.4    Lewis, S.M.5
  • 57
    • 0036042209 scopus 로고    scopus 로고
    • High humidity affects HemoCue cuvette function and HemoCue haemoglobin estimation in tropical Australia
    • Nguyen HT. High humidity affects HemoCue cuvette function and HemoCue haemoglobin estimation in tropical Australia. J Paediatr Child Health. 2002;38(4):427-428.
    • (2002) J Paediatr Child Health , vol.38 , Issue.4 , pp. 427-428
    • Nguyen, H.T.1
  • 58
    • 84983750761 scopus 로고    scopus 로고
    • Validation of a hemoglobinometer for use in outdoor blood donation camps
    • Dubey A, Murti S. Validation of a hemoglobinometer for use in outdoor blood donation camps. Asian J Transfus Sci. 2016;10(2):164-165.
    • (2016) Asian J Transfus Sci , vol.10 , Issue.2 , pp. 164-165
    • Dubey, A.1    Murti, S.2
  • 59
    • 34547112295 scopus 로고    scopus 로고
    • Evaluation of four rapid methods for hemoglobin screening of whole blood donors in mobile collection settings
    • Gómez-Simón A, Navarro-Núñez L, Pérez-Ceballos E, et al. Evaluation of four rapid methods for hemoglobin screening of whole blood donors in mobile collection settings. Transfus Apher Sci. 2007;36(3): 235-242.
    • (2007) Transfus Apher Sci , vol.36 , Issue.3 , pp. 235-242
    • Gómez-Simón, A.1    Navarro-Núñez, L.2    Pérez-Ceballos, E.3
  • 60
    • 84863635746 scopus 로고    scopus 로고
    • Validation and implementation of a new hemoglobinometer for donor screening at Canadian Blood Services
    • Goldman M, Uzicanin S, Yi QL, Acker J, Ramirez-Arcos S. Validation and implementation of a new hemoglobinometer for donor screening at Canadian Blood Services. Transfusion. 2012;52(7):1607-1613.
    • (2012) Transfusion , vol.52 , Issue.7 , pp. 1607-1613
    • Goldman, M.1    Uzicanin, S.2    Yi, Q.L.3    Acker, J.4    Ramirez-Arcos, S.5
  • 61
    • 34248199333 scopus 로고    scopus 로고
    • Evaluation of hemoglobin of blood donors deferred by the copper sulphate method for haemoglobin estimation
    • Sawant RB, Bharucha ZS, Rajadhyaksha SB. Evaluation of hemoglobin of blood donors deferred by the copper sulphate method for haemoglobin estimation. Transfus Apher Sci. 2007;36(2):143-148.
    • (2007) Transfus Apher Sci , vol.36 , Issue.2 , pp. 143-148
    • Sawant, R.B.1    Bharucha, Z.S.2    Rajadhyaksha, S.B.3
  • 62
    • 84880387451 scopus 로고    scopus 로고
    • Comparison of the accuracy of noninvasive hemoglobin sensor (NBM-200) and portable hemoglobinometer (HemoCue) with an automated hematology analyzer (LH500) in blood donor screening
    • Kim MJ, Park Q, Kim MH, Shin JW, Kim HO. Comparison of the accuracy of noninvasive hemoglobin sensor (NBM-200) and portable hemoglobinometer (HemoCue) with an automated hematology analyzer (LH500) in blood donor screening. Ann Lab Med. 2013;33(4): 261-267.
    • (2013) Ann Lab Med , vol.33 , Issue.4 , pp. 261-267
    • Kim, M.J.1    Park, Q.2    Kim, M.H.3    Shin, J.W.4    Kim, H.O.5
  • 63
    • 84880308380 scopus 로고    scopus 로고
    • Noninvasive methods for haemoglobin screening in prospective blood donors
    • Belardinelli A, Benni M, Tazzari PL, Pagliaro P. Noninvasive methods for haemoglobin screening in prospective blood donors. Vox Sang. 2013;105(2):116-120.
    • (2013) Vox Sang , vol.105 , Issue.2 , pp. 116-120
    • Belardinelli, A.1    Benni, M.2    Tazzari, P.L.3    Pagliaro, P.4
  • 64
    • 84982872963 scopus 로고    scopus 로고
    • Hemoglobin assessment: Precision and practicability evaluated in the Netherlands-the HAPPEN study
    • Baart AM, de Kort WL, van den Hurk K, Pasker-de Jong PC. Hemoglobin assessment: precision and practicability evaluated in the Netherlands-the HAPPEN study. Transfusion. 2016;56(8):1984-1993.
    • (2016) Transfusion , vol.56 , Issue.8 , pp. 1984-1993
    • Baart, A.M.1    De Kort, W.L.2    Van Den Hurk, K.3    Pasker-De Jong, P.C.4
  • 65
    • 84959470603 scopus 로고    scopus 로고
    • The impact of noninvasive, capillary, and venous haemoglobin screening on donor deferrals and the haemoglobin content of red blood cells concentrates: A prospective study
    • Sümnig A, Hron G, Westphal A, et al. The impact of noninvasive, capillary, and venous haemoglobin screening on donor deferrals and the haemoglobin content of red blood cells concentrates: a prospective study. Transfusion. 2015;55(12):2847-2854.
    • (2015) Transfusion , vol.55 , Issue.12 , pp. 2847-2854
    • Sümnig, A.1    Hron, G.2    Westphal, A.3
  • 67
    • 84876134626 scopus 로고    scopus 로고
    • The new noninvasive occlusion spectroscopy hemoglobin measurement method: A reliable and easy anemia screening test for blood donors
    • Pinto M, Barjas-Castro ML, Nascimento S, Falconi MA, Zulli R, Castro V. The new noninvasive occlusion spectroscopy hemoglobin measurement method: a reliable and easy anemia screening test for blood donors. Transfusion. 2013;53(4):766-769.
    • (2013) Transfusion , vol.53 , Issue.4 , pp. 766-769
    • Pinto, M.1    Barjas-Castro, M.L.2    Nascimento, S.3    Falconi, M.A.4    Zulli, R.5    Castro, V.6
  • 68
  • 69
    • 84897026681 scopus 로고    scopus 로고
    • Validation of a noninvasive pulse CO-oximetry based hemoglobin estimation in normal blood donors
    • Al-Khabori M, Al-Riyami AZ, Al-Farsi K, et al. Validation of a noninvasive pulse CO-oximetry based hemoglobin estimation in normal blood donors. Transfus Apher Sci. 2014;50(1):95-98.
    • (2014) Transfus Apher Sci , vol.50 , Issue.1 , pp. 95-98
    • Al-Khabori, M.1    Al-Riyami, A.Z.2    Al-Farsi, K.3
  • 70
    • 27744584205 scopus 로고    scopus 로고
    • A noninvasive strategy for screening prospective blood donors for anemia
    • Lotfi R, Wernet D, Starke U, Northoff H, Cassens U. A noninvasive strategy for screening prospective blood donors for anemia. Transfusion. 2005;45(10):1585-1592.
    • (2005) Transfusion , vol.45 , Issue.10 , pp. 1585-1592
    • Lotfi, R.1    Wernet, D.2    Starke, U.3    Northoff, H.4    Cassens, U.5
  • 71
    • 27744447331 scopus 로고    scopus 로고
    • Another stab at donor haemoglobin screening
    • Goldman MR. Another stab at donor haemoglobin screening. Transfusion. 2005;45(10):1552-1553.
    • (2005) Transfusion , vol.45 , Issue.10 , pp. 1552-1553
    • Goldman, M.R.1
  • 72
    • 33751383276 scopus 로고    scopus 로고
    • Selection of whole-blood donors for hemoglobin testing by use of historical hemoglobin values
    • Ziemann M, Steppat D, Brockmann C, Washington G, Kirchner H, Schlenke P. Selection of whole-blood donors for hemoglobin testing by use of historical hemoglobin values. Transfusion. 2006;46(12):2176-2183.
    • (2006) Transfusion , vol.46 , Issue.12 , pp. 2176-2183
    • Ziemann, M.1    Steppat, D.2    Brockmann, C.3    Washington, G.4    Kirchner, H.5    Schlenke, P.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.