메뉴 건너뛰기




Volumn 90, Issue 12, 2015, Pages 1122-1127

An accurate and inexpensive color-based assay for detecting severe anemia in a limited-resource setting

Author keywords

[No Author keywords available]

Indexed keywords

HEMOGLOBIN;

EID: 84954286829     PISSN: 03618609     EISSN: 10968652     Source Type: Journal    
DOI: 10.1002/ajh.24180     Document Type: Article
Times cited : (14)

References (28)
  • 1
    • 84894067309 scopus 로고    scopus 로고
    • A systematic analysis of global anemia burden from 1990 to 2010
    • Kassebaum NJ, Jasrasaria R, Naghavi M, et al. A systematic analysis of global anemia burden from 1990 to 2010. Blood 2014;123:615-624.
    • (2014) Blood , vol.123 , pp. 615-624
    • Kassebaum, N.J.1    Jasrasaria, R.2    Naghavi, M.3
  • 2
    • 65449184945 scopus 로고    scopus 로고
    • Worldwide prevalence of anemia, WHO Vitamin and Mineral Nutrition Information System, 1993-2005
    • McLean E, Cogswell M, Egli I, et al. Worldwide prevalence of anemia, WHO Vitamin and Mineral Nutrition Information System, 1993-2005. Public Health Nutr 2009;12:444-454.
    • (2009) Public Health Nutr , vol.12 , pp. 444-454
    • McLean, E.1    Cogswell, M.2    Egli, I.3
  • 3
    • 84888429328 scopus 로고    scopus 로고
    • The blood supply in Sub-Saharan Africa: Needs, challenges, and solutions
    • Lund TC, Hume H, Allain JP, et al. The blood supply in Sub-Saharan Africa: Needs, challenges, and solutions. Transfus Apher Sci 2013;49:416-421.
    • (2013) Transfus Apher Sci , vol.49 , pp. 416-421
    • Lund, T.C.1    Hume, H.2    Allain, J.P.3
  • 4
    • 0031560184 scopus 로고    scopus 로고
    • Integrated management of childhood illness
    • Costello A. Integrated management of childhood illness. Lancet 1997;350:1266.
    • (1997) Lancet , vol.350 , pp. 1266
    • Costello, A.1
  • 5
    • 0031851942 scopus 로고    scopus 로고
    • Integrated Management of Childhood Illness: Conclusions WHO Division of Child Health and Development
    • Integrated Management of Childhood Illness: Conclusions WHO Division of Child Health and Development. Bull World Health Organ 1997;75:119-128.
    • (1997) Bull World Health Organ , vol.75 , pp. 119-128
  • 6
    • 29244491121 scopus 로고    scopus 로고
    • Accuracy of clinical pallor in the diagnosis of anemia in children: A meta-analysis
    • Chalco JP, Huicho L, Alamo C, et al. Accuracy of clinical pallor in the diagnosis of anemia in children: A meta-analysis. BMC Pediatr 2005;5:46.
    • (2005) BMC Pediatr , vol.5 , pp. 46
    • Chalco, J.P.1    Huicho, L.2    Alamo, C.3
  • 7
    • 84954241683 scopus 로고    scopus 로고
    • Geneva, Switzerland: World Health Organization, Available at:(Last accessed September 5, 2015)
    • Review of the Hemoglobin Colour Scale: Report of an informal consultation. Geneva, Switzerland: World Health Organization, 2004. Available at: http://www.who.int/medical_devices/publications/en/HbCS_Research_AgendaStudyDesign.pdf (Last accessed September 5, 2015)
    • (2004) Review of the Hemoglobin Colour Scale: Report of an informal consultation
  • 8
    • 33749343994 scopus 로고    scopus 로고
    • Geneva, Switzerland: World Health Organization, Available at:(Last accessed September 5, 2015)
    • Hemoglobin Colour Scale: Operational Research Agenda and Study Design. Geneva, Switzerland: World Health Organization, 2004. Available at: http://www.who.int/medical_devices/publications/en/HbCS_Research_AgendaStudyDesign.pdf (Last accessed September 5, 2015)
    • (2004) Hemoglobin Colour Scale: Operational Research Agenda and Study Design
  • 9
    • 84907484215 scopus 로고    scopus 로고
    • Disposable platform provides visual and color-based point-of-care anemia self-testing
    • Tyburski EA, Gillespie SE, Stoy WA, et al. Disposable platform provides visual and color-based point-of-care anemia self-testing. J Clin Invest 2014;124:4387-4394.
    • (2014) J Clin Invest , vol.124 , pp. 4387-4394
    • Tyburski, E.A.1    Gillespie, S.E.2    Stoy, W.A.3
  • 10
    • 84891534564 scopus 로고    scopus 로고
    • Simple paper-based test for measuring blood hemoglobin concentration in resource-limited settings
    • Yang X, Piety NZ, Vignes SM, et al. Simple paper-based test for measuring blood hemoglobin concentration in resource-limited settings. Clin Chem 2013;59:1506-1513.
    • (2013) Clin Chem , vol.59 , pp. 1506-1513
    • Yang, X.1    Piety, N.Z.2    Vignes, S.M.3
  • 11
    • 84947934800 scopus 로고    scopus 로고
    • Performance analysis of newly developed point-of-care hemoglobinometer (TrueHb) against an automated hematology analyzer (Sysmex XT 1800i) in terms of precision in hemoglobin measurement
    • Srivastava A, Koul V, Dwivedi SN, et al. Performance analysis of newly developed point-of-care hemoglobinometer (TrueHb) against an automated hematology analyzer (Sysmex XT 1800i) in terms of precision in hemoglobin measurement. Int J Lab Hematol 2014;37:483-485. doi: 10.1111/ijlh.12314.
    • (2014) Int J Lab Hematol , vol.37 , pp. 483-485
    • Srivastava, A.1    Koul, V.2    Dwivedi, S.N.3
  • 12
    • 84969424196 scopus 로고    scopus 로고
    • Validity of point-of-care testing mission plus in detecting anemia
    • Ahmad NA, Awaluddin SM, Samad R, et al. Validity of point-of-care testing mission plus in detecting anemia. Int J Biomed 2015;5:91-94.
    • (2015) Int J Biomed , vol.5 , pp. 91-94
    • Ahmad, N.A.1    Awaluddin, S.M.2    Samad, R.3
  • 13
    • 0020478887 scopus 로고
    • The horseradish peroxidase-catalyzed oxidation of 3,5,3′,5′-tetramethylbenzidine. Free radical and charge-transfer complex intermediates
    • Josephy PD, Eling T, Mason RP. The horseradish peroxidase-catalyzed oxidation of 3, 5, 3′, 5′-tetramethylbenzidine. Free radical and charge-transfer complex intermediates. J Biol Chem 1982;257:3669-3675.
    • (1982) J Biol Chem , vol.257 , pp. 3669-3675
    • Josephy, P.D.1    Eling, T.2    Mason, R.P.3
  • 14
    • 0019829934 scopus 로고
    • Use of 3,3′,5,5′-tetramethylbenzidine (TMB) in the identification of erythroid colonies
    • Reynolds M, Lawlor E, McCann SR, Temperley U. Use of 3, 3′, 5, 5′-tetramethylbenzidine (TMB) in the identification of erythroid colonies. J Clin Pathol 1981;34:448-449.
    • (1981) J Clin Pathol , vol.34 , pp. 448-449
    • Reynolds, M.1    Lawlor, E.2    McCann, S.R.3    Temperley, U.4
  • 15
    • 0020055759 scopus 로고
    • Measuring hemoglobin in plasma by reaction with tetramethylbenzidine
    • Levinson SS, Goldman JJ. Measuring hemoglobin in plasma by reaction with tetramethylbenzidine. Clin Chem 1982;28:471-474.
    • (1982) Clin Chem , vol.28 , pp. 471-474
    • Levinson, S.S.1    Goldman, J.J.2
  • 16
    • 0021804683 scopus 로고
    • Occult blood testing using tetramethylbenzidine in an extraction procedure for patients on unrestricted diets
    • Zierdt WS, Zierdt CH. Occult blood testing using tetramethylbenzidine in an extraction procedure for patients on unrestricted diets. Am J Clin Pathol 1985;83:486-488.
    • (1985) Am J Clin Pathol , vol.83 , pp. 486-488
    • Zierdt, W.S.1    Zierdt, C.H.2
  • 17
    • 84876043276 scopus 로고    scopus 로고
    • Medical device donations: Considerations for solicitation and provision: WHO Medical device technical series
    • Geneva, Switzerland: World Health Organization, Available at:(Last accessed September 5, 2015)
    • Medical device donations: Considerations for solicitation and provision: WHO Medical device technical series. Geneva, Switzerland: World Health Organization, 2011. Available at: http://whqlibdoc.who.int/publications/2011/9789241501408_eng.pdf (Last accessed September 5, 2015)
    • (2011)
  • 18
    • 84906482950 scopus 로고    scopus 로고
    • Validation of the hemoglobin colour scale for screening blood donors in Malawi
    • M'Baya B, Mbingwani I, Mgawi L, et al. Validation of the hemoglobin colour scale for screening blood donors in Malawi. Malawi Med J 2014;26:30-33.
    • (2014) Malawi Med J , vol.26 , pp. 30-33
    • M'Baya, B.1    Mbingwani, I.2    Mgawi, L.3
  • 19
    • 29244439567 scopus 로고    scopus 로고
    • Hemoglobin colour scale for anemia diagnosis where there is no laboratory: A systematic review
    • Critchley J, Bates I. Hemoglobin colour scale for anemia diagnosis where there is no laboratory: A systematic review. Int J Epidemiol 2005;34:1425-1434.
    • (2005) Int J Epidemiol , vol.34 , pp. 1425-1434
    • Critchley, J.1    Bates, I.2
  • 20
    • 84859008324 scopus 로고    scopus 로고
    • Evaluation of the diagnostic accuracy of the hemoglobin colour scale to detect anemia in young children attending primary healthcare clinics in Zanzibar
    • Aldridge C, Foster HM, Albonico M, et al. Evaluation of the diagnostic accuracy of the hemoglobin colour scale to detect anemia in young children attending primary healthcare clinics in Zanzibar. Trop Med Int Health 2012;17:423-429.
    • (2012) Trop Med Int Health , vol.17 , pp. 423-429
    • Aldridge, C.1    Foster, H.M.2    Albonico, M.3
  • 21
    • 0037398837 scopus 로고    scopus 로고
    • Comparison of screening methods for anemia in pregnant women in Awassa, Ethiopia
    • Gies S, Brabin BJ, Yassin MA, Cuevas LE. Comparison of screening methods for anemia in pregnant women in Awassa, Ethiopia. Trop Med Int Health 2003;8:301-309.
    • (2003) Trop Med Int Health , vol.8 , pp. 301-309
    • Gies, S.1    Brabin, B.J.2    Yassin, M.A.3    Cuevas, L.E.4
  • 22
    • 0022898207 scopus 로고
    • Evaluation of "HemoCue," a new device for determining hemoglobin
    • von Schenck H, Falkensson M, Lundberg B. Evaluation of "HemoCue, " a new device for determining hemoglobin. Clin Chem 1986;32:526-529.
    • (1986) Clin Chem , vol.32 , pp. 526-529
    • von Schenck, H.1    Falkensson, M.2    Lundberg, B.3
  • 23
    • 0036032843 scopus 로고    scopus 로고
    • Evaluation of the hemoglobin colour scale and comparison with the HemoCue hemoglobin assay
    • Paddle JJ. Evaluation of the hemoglobin colour scale and comparison with the HemoCue hemoglobin assay. Bull World Health Organ 2002;80:813-816.
    • (2002) Bull World Health Organ , vol.80 , pp. 813-816
    • Paddle, J.J.1
  • 25
    • 79954594760 scopus 로고    scopus 로고
    • Hemoglobin estimation by the HemoCue(R) portable hemoglobin photometer in a resource poor setting
    • Nkrumah B, Blay Nguah S, Sarpong N, et al. Hemoglobin estimation by the HemoCue(R) portable hemoglobin photometer in a resource poor setting. BMC Clin Pathol 2011;11:5.
    • (2011) BMC Clin Pathol , vol.11 , pp. 5
    • Nkrumah, B.1    Blay Nguah, S.2    Sarpong, N.3
  • 26
    • 0036042209 scopus 로고    scopus 로고
    • High humidity affects HemoCue cuvette function and HemoCue hemoglobin estimation in tropical Australia
    • Nguyen HT. High humidity affects HemoCue cuvette function and HemoCue hemoglobin estimation in tropical Australia. J Paediatr Child Health 2002;38:427-428.
    • (2002) J Paediatr Child Health , vol.38 , pp. 427-428
    • Nguyen, H.T.1
  • 27
    • 0026541825 scopus 로고
    • A clinical evaluation of the Hemocue hemoglobinometer using capillary, venous, and arterial samples
    • Chen PP, Short TG, Leung DH, Oh TE. A clinical evaluation of the Hemocue hemoglobinometer using capillary, venous, and arterial samples. Anaesth Intensive Care 1992;20:497-500.
    • (1992) Anaesth Intensive Care , vol.20 , pp. 497-500
    • Chen, P.P.1    Short, T.G.2    Leung, D.H.3    Oh, T.E.4
  • 28
    • 1842846647 scopus 로고    scopus 로고
    • Hemoglobin measured by Hemocue and a reference method in venous and capillary blood: A validation study
    • Neufeld L, García-Guerra A, Sánchez-Francia D, et al. Hemoglobin measured by Hemocue and a reference method in venous and capillary blood: A validation study. Salud Publica Mex 2002;44:219-227.
    • (2002) Salud Publica Mex , vol.44 , pp. 219-227
    • Neufeld, L.1    García-Guerra, A.2    Sánchez-Francia, D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.