-
1
-
-
84885219584
-
Global, regional, and national trends in haemoglobin concentration and prevalence of total and severe anaemia in children and pregnant and non-pregnant women for 1995-2011: A systematic analysis of population-representative data
-
Stevens GA, Finucane MM, De-Regil LM, et al. Global, regional, and national trends in haemoglobin concentration and prevalence of total and severe anaemia in children and pregnant and non-pregnant women for 1995-2011: a systematic analysis of population-representative data. Lancet Glob Health 2013;1:e16-25.
-
(2013)
Lancet Glob Health
, vol.1
, pp. e16-e25
-
-
Stevens, G.A.1
Finucane, M.M.2
De-Regil, L.M.3
-
2
-
-
84881182352
-
Maternal and child undernutrition and overweight in low-income and middle-income countries
-
Black RE, Victora CG, Walker SP, et al. Maternal and child undernutrition and overweight in low-income and middle-income countries. Lancet 2013;382:427-51.
-
(2013)
Lancet
, vol.382
, pp. 427-451
-
-
Black, R.E.1
Victora, C.G.2
Walker, S.P.3
-
3
-
-
83955164266
-
Anaemia in low-income and middle-income countries
-
Balarajan Y, Ramakrishnan U, Ozaltin E, et al. Anaemia in low-income and middle-income countries. Lancet 2011;378:2123-35.
-
(2011)
Lancet
, vol.378
, pp. 2123-2135
-
-
Balarajan, Y.1
Ramakrishnan, U.2
Ozaltin, E.3
-
8
-
-
84880093829
-
Anaemia, prenatal iron use, and risk of adverse pregnancy outcomes: Systematic review and meta-analysis
-
Haider BA, Olofin I, Wang M, et al. Anaemia, prenatal iron use, and risk of adverse pregnancy outcomes: systematic review and meta-analysis. BMJ 2013;346:f3443.
-
(2013)
BMJ
, vol.346
, pp. f3443
-
-
Haider, B.A.1
Olofin, I.2
Wang, M.3
-
9
-
-
84856476213
-
Haemoglobin concentrations for the diagnosis of anaemia and assessment of severity
-
WHO. Geneva
-
WHO. Haemoglobin concentrations for the diagnosis of anaemia and assessment of severity. vitamin and mineral nutrition information system. Geneva, 2011.
-
(2011)
Vitamin and Mineral Nutrition Information System
-
-
-
10
-
-
0032973798
-
Precision, accuracy, and reliability of hemoglobin assessment with use of capillary blood
-
Morris SS, Ruel MT, Cohen RJ, et al. Precision, accuracy, and reliability of hemoglobin assessment with use of capillary blood. Am J Clin Nutr 1999;69:1243-8.
-
(1999)
Am J Clin Nutr
, vol.69
, pp. 1243-1248
-
-
Morris, S.S.1
Ruel, M.T.2
Cohen, R.J.3
-
11
-
-
0035213196
-
Cytometry E-colorflow. A powerful tool for elucidation of the complex immune system
-
De Rosa SC, Roederer M, cytometry E-colorflow. A powerful tool for elucidation of the complex immune system. Clin Lab Med 2001;21:697-712.
-
(2001)
Clin Lab Med
, vol.21
, pp. 697-712
-
-
De Rosa, S.C.1
Roederer, M.2
-
12
-
-
56149124411
-
Hookworm-related anaemia among pregnant women: A systematic review
-
Brooker S, Hotez PJ, Bundy DA. Hookworm-related anaemia among pregnant women: a systematic review. PLoS Negl Trop Dis 2008;2:e291.
-
(2008)
PLoS Negl Trop Dis
, vol.2
-
-
Brooker, S.1
Hotez, P.J.2
Bundy, D.A.3
-
13
-
-
0029052546
-
A simple and reliable method for estimating haemoglobin
-
Stott GJ, Lewis SM. A simple and reliable method for estimating haemoglobin. Bull World Health Organ 1995;73:369-73.
-
(1995)
Bull World Health Organ
, vol.73
, pp. 369-373
-
-
Stott, G.J.1
Lewis, S.M.2
-
15
-
-
33750214936
-
Simple method for estimation of hemoglobin in human blood using color analysis
-
Ranganathan H, Gunasekaran N. Simple method for estimation of hemoglobin in human blood using color analysis. IEEE Trans Inf Technol Biomed 2006;10:657-62.
-
(2006)
IEEE Trans Inf Technol Biomed
, vol.10
, pp. 657-662
-
-
Ranganathan, H.1
Gunasekaran, N.2
-
16
-
-
46149090832
-
An integrated optofluidic platform for Raman-activated cell sorting
-
Lau AY, Lee LP, Chan JW. An integrated optofluidic platform for Raman-activated cell sorting. Lab Chip 2008;8:1116-20.
-
(2008)
Lab Chip
, vol.8
, pp. 1116-1120
-
-
Lau, A.Y.1
Lee, L.P.2
Chan, J.W.3
-
17
-
-
84858600400
-
Comparison of HemoCue® hemoglobin-meter and automated hematology analyzer in measurement of hemoglobin levels in pregnant women at Khartoum hospital, Sudan
-
Adam I, Ahmed S, Mahmoud MH, et al. Comparison of HemoCue® hemoglobin-meter and automated hematology analyzer in measurement of hemoglobin levels in pregnant women at Khartoum hospital, Sudan. Diagn Pathol 2012;7:30.
-
(2012)
Diagn Pathol
, vol.7
, pp. 30
-
-
Adam, I.1
Ahmed, S.2
Mahmoud, M.H.3
-
18
-
-
80052966840
-
Reliability of the HemoCue® hemoglobinometer in critically ill patients: A prospective observational study
-
Mimoz O, Frasca D, Médard A, et al. Reliability of the HemoCue® hemoglobinometer in critically ill patients: a prospective observational study. Minerva Anestesiol 2011;77:979-85.
-
(2011)
Minerva Anestesiol
, vol.77
, pp. 979-985
-
-
Mimoz, O.1
Frasca, D.2
Médard, A.3
-
19
-
-
0034955316
-
Estimating the prevalence of anaemia: A comparison of three methods
-
Sari M, de Pee S, Martini E, et al. Estimating the prevalence of anaemia: a comparison of three methods. Bull World Health Organ 2001;79:506-11.
-
(2001)
Bull World Health Organ
, vol.79
, pp. 506-511
-
-
Sari, M.1
De Pee, S.2
Martini, E.3
-
20
-
-
84888395703
-
Comparison between two portable hemoglobinometers and a reference method to verify the reliability of screening in blood donors
-
Rudolf-Oliveira RC, Gonçalves KT, Martignago ML, et al. Comparison between two portable hemoglobinometers and a reference method to verify the reliability of screening in blood donors. Transfus Apher Sci 2013;49:578-82.
-
(2013)
Transfus Apher Sci
, vol.49
, pp. 578-582
-
-
Rudolf-Oliveira, R.C.1
Gonçalves, K.T.2
Martignago, M.L.3
-
21
-
-
84920896721
-
Evaluation of two methods to measure hemoglobin concentration among women with genetic hemoglobin disorders in Cambodia: A method-comparison study
-
Karakochuk CD, Janmohamed A, Whitfield KC, et al. Evaluation of two methods to measure hemoglobin concentration among women with genetic hemoglobin disorders in Cambodia: a method-comparison study. Clin Chim Acta 2015;441:148-55.
-
(2015)
Clin Chim Acta
, vol.441
, pp. 148-155
-
-
Karakochuk, C.D.1
Janmohamed, A.2
Whitfield, K.C.3
-
22
-
-
80052177803
-
Comparison of the accuracy of noninvasive hemoglobin monitoring by spectrophotometry (SpHb) and HemoCue® with automated laboratory hemoglobin measurement
-
Lamhaut L, Apriotesei R, Combes X, et al. Comparison of the accuracy of noninvasive hemoglobin monitoring by spectrophotometry (SpHb) and HemoCue® with automated laboratory hemoglobin measurement. Anesthesiology 2011;115:548-54.
-
(2011)
Anesthesiology
, vol.115
, pp. 548-554
-
-
Lamhaut, L.1
Apriotesei, R.2
Combes, X.3
-
23
-
-
0026541825
-
A clinical evaluation of the Hemocue haemoglobinometer using capillary, venous and arterial samples
-
Chen PP, Short TG, Leung DH, et al. A clinical evaluation of the Hemocue haemoglobinometer using capillary, venous and arterial samples. Anaesth Intensive Care 1992;20:497-500.
-
(1992)
Anaesth Intensive Care
, vol.20
, pp. 497-500
-
-
Chen, P.P.1
Short, T.G.2
Leung, D.H.3
-
24
-
-
0031283092
-
Hemocue, an accurate bedside method of hemoglobin measurement?
-
Rippmann CE, Nett PC, Popovic D, et al. Hemocue, an accurate bedside method of hemoglobin measurement? J Clin Monit 1997;13:373-7.
-
(1997)
J Clin Monit
, vol.13
, pp. 373-377
-
-
Rippmann, C.E.1
Nett, P.C.2
Popovic, D.3
-
25
-
-
79954594760
-
Hemoglobin estimation by the HemoCue® portable hemoglobin photometer in a resource poor setting
-
Nkrumah B, Nguah SB, Sarpong N, et al. Hemoglobin estimation by the HemoCue® portable hemoglobin photometer in a resource poor setting. BMC Clin Pathol 2011;11:5.
-
(2011)
BMC Clin Pathol
, vol.11
, pp. 5
-
-
Nkrumah, B.1
Nguah, S.B.2
Sarpong, N.3
-
26
-
-
84876731478
-
Capillary versus venous haemoglobin determination in the assessment of healthy blood donors
-
Patel AJ, Wesley R, Leitman SF, et al. Capillary versus venous haemoglobin determination in the assessment of healthy blood donors. Vox Sang 2013;104:317-23.
-
(2013)
Vox Sang
, vol.104
, pp. 317-323
-
-
Patel, A.J.1
Wesley, R.2
Leitman, S.F.3
-
27
-
-
0023821099
-
HemoCue system for hemoglobin measurement. Evaluation in anemic and nonanemic children
-
Cohen AR, Seidl-Friedman J. HemoCue system for hemoglobin measurement. Evaluation in anemic and nonanemic children. Am J Clin Pathol 1988;90:302-5.
-
(1988)
Am J Clin Pathol
, vol.90
, pp. 302-305
-
-
Cohen, A.R.1
Seidl-Friedman, J.2
-
28
-
-
0024367057
-
Screening for anaemia: Evaluation of a haemoglobinometer
-
Mills AF, Meadows N. Screening for anaemia: evaluation of a haemoglobinometer. Arch Dis Child 1989;64:1468-71.
-
(1989)
Arch Dis Child
, vol.64
, pp. 1468-1471
-
-
Mills, A.F.1
Meadows, N.2
-
29
-
-
1842846647
-
Hemoglobin measured by Hemocue and a reference method in venous and capillary blood: A validation study
-
Neufeld L, García-Guerra A, Sánchez-Francia D, et al. Hemoglobin measured by Hemocue and a reference method in venous and capillary blood: a validation study. Salud Publica Mex 2002;44:219-27.
-
(2002)
Salud Publica Mex
, vol.44
, pp. 219-227
-
-
Neufeld, L.1
García-Guerra, A.2
Sánchez-Francia, D.3
-
30
-
-
84942257824
-
Evaluation of the diagnostic accuracy of the HemoCue device for detecting anaemia in healthy school-aged children in KwaZulu-Natal, South Africa
-
Gwetu TP, Chhagan MK. Evaluation of the diagnostic accuracy of the HemoCue device for detecting anaemia in healthy school-aged children in KwaZulu-Natal, South Africa. S Afr Med J 2015;105:596-9.
-
(2015)
S Afr Med J
, vol.105
, pp. 596-599
-
-
Gwetu, T.P.1
Chhagan, M.K.2
-
31
-
-
85006137707
-
Sample Size for assessing agreement between two methods of measurement by bland-altman method
-
Lu MJ, Zhong WH, Liu YX, et al. Sample Size for assessing agreement between two methods of measurement by bland-altman method. Int J Biostat 2016;12.
-
(2016)
Int J Biostat
, vol.12
-
-
Lu, M.J.1
Zhong, W.H.2
Liu, Y.X.3
-
33
-
-
84867866490
-
Statistics corner: A guide to appropriate use of correlation coefficient in medical research
-
Mukaka MM. Statistics corner: A guide to appropriate use of correlation coefficient in medical research. Malawi Med J 2012;24:69-71.
-
(2012)
Malawi Med J
, vol.24
, pp. 69-71
-
-
Mukaka, M.M.1
-
34
-
-
0024521543
-
A concordance correlation coefficient to evaluate reproducibility
-
Lin LI. A concordance correlation coefficient to evaluate reproducibility. Biometrics 1989;45:255-68.
-
(1989)
Biometrics
, vol.45
, pp. 255-268
-
-
Lin, L.I.1
-
35
-
-
84908219488
-
Statistical methods for assessing agreement between two methods of clinical measurement
-
Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986;1:307-10.
-
(1986)
Lancet
, vol.1
, pp. 307-310
-
-
Bland, J.M.1
Altman, D.G.2
-
36
-
-
4544365096
-
Comparison between the HemoCue and an automated counter for measuring hemoglobin
-
Paiva AA, Rondó PH, Silva SS, et al. Comparison between the HemoCue and an automated counter for measuring hemoglobin. Rev Saude Publica 2004;38:585-7.
-
(2004)
Rev Saude Publica
, vol.38
, pp. 585-587
-
-
Paiva, A.A.1
Rondó, P.H.2
Silva, S.S.3
-
37
-
-
0019428934
-
On the composition of capillary and venous blood serum
-
Kupke IR, Kather B, Zeugner S. On the composition of capillary and venous blood serum. Clin Chim Acta 1981;112:177-85.
-
(1981)
Clin Chim Acta
, vol.112
, pp. 177-185
-
-
Kupke, I.R.1
Kather, B.2
Zeugner, S.3
-
38
-
-
77951138250
-
Capillary and venous haemoglobin levels in blood donors: A 42-month study of 36,258 paired samples
-
Tong E, Murphy WG, Kinsella A, et al. Capillary and venous haemoglobin levels in blood donors: a 42-month study of 36,258 paired samples. Vox Sang 2010;98:547-53.
-
(2010)
Vox Sang
, vol.98
, pp. 547-553
-
-
Tong, E.1
Murphy, W.G.2
Kinsella, A.3
-
39
-
-
0028508075
-
Improved strategy for screening prospective blood donors for anaemia
-
Boulton FE, Nightingale MJ, Reynolds W. Improved strategy for screening prospective blood donors for anaemia. Transfus Med 1994;4:221-5.
-
(1994)
Transfus Med
, vol.4
, pp. 221-225
-
-
Boulton, F.E.1
Nightingale, M.J.2
Reynolds, W.3
-
40
-
-
0026731563
-
Plasma volume, osmolarity, total protein and electrolytes during treadmill running and cycle ergometer exercise
-
Gore CJ, Scroop GC, Marker JD, et al. Plasma volume, osmolarity, total protein and electrolytes during treadmill running and cycle ergometer exercise. Eur J Appl Physiol Occup Physiol 1992;65:302-10.
-
(1992)
Eur J Appl Physiol Occup Physiol
, vol.65
, pp. 302-310
-
-
Gore, C.J.1
Scroop, G.C.2
Marker, J.D.3
-
41
-
-
85031037330
-
Mean hemoglobin concentrations in fasting venous and non-fasting capillary blood of Cambodian women using a hemoglobinometer and an automated hematology analyzer
-
Karakochuk CD, Rappaport AI, Barr SI, et al. Mean hemoglobin concentrations in fasting venous and non-fasting capillary blood of Cambodian women using a hemoglobinometer and an automated hematology analyzer. Clin Chem Lab Med 2017;55:e247-e50.
-
(2017)
Clin Chem Lab Med
, vol.55
, pp. e247-e250
-
-
Karakochuk, C.D.1
Rappaport, A.I.2
Barr, S.I.3
-
42
-
-
85021244991
-
Variation in haemoglobin measurement across different HemoCue devices and device operators in rural Cambodia
-
Rappaport AI, Barr SI, Green TJ, et al. Variation in haemoglobin measurement across different HemoCue devices and device operators in rural Cambodia. J Clin Pathol 2017;70:615-8.
-
(2017)
J Clin Pathol
, vol.70
, pp. 615-618
-
-
Rappaport, A.I.1
Barr, S.I.2
Green, T.J.3
-
43
-
-
0022898207
-
Evaluation of "HemoCue," a new device for determining hemoglobin
-
von Schenck H, Falkensson M, Lundberg B. Evaluation of "HemoCue," a new device for determining hemoglobin. Clin Chem 1986;32:526-9.
-
(1986)
Clin Chem
, vol.32
, pp. 526-529
-
-
Von Schenck, H.1
Falkensson, M.2
Lundberg, B.3
|