메뉴 건너뛰기




Volumn 82, Issue 2, 2002, Pages 76-79

Evaluation of the HemoCue plasma haemoglobin analyser for assessing haemolysis in red cell concentrates during storage

Author keywords

Haemoglobin; Haemolysis; Red cell concentrate; Storage

Indexed keywords

ANALYZER; ARTICLE; CORRELATION ANALYSIS; DIAGNOSTIC ACCURACY; ERYTHROCYTE CONCENTRATE; ERYTHROCYTE PRESERVATION; EVALUATION; HEMOGLOBIN ANALYSIS; HEMOLYSIS; HUMAN; PRIORITY JOURNAL; RELIABILITY; SPECTROPHOTOMETRY; STATISTICAL ANALYSIS; SUPERNATANT; BLOOD SAMPLING; ERYTHROCYTE COUNT; HEMOGLOBIN DETERMINATION; HOSPITAL INFORMATION SYSTEM; INSTRUMENTATION; METHODOLOGY; REPRODUCIBILITY; SENSITIVITY AND SPECIFICITY; STANDARD;

EID: 0036485122     PISSN: 00429007     EISSN: None     Source Type: Journal    
DOI: 10.1046/j.0042-9007.2001.00149.x     Document Type: Article
Times cited : (15)

References (7)
  • 2
    • 84963086883 scopus 로고
    • Studies on hemoglobin: Ultra-method for determination of hemoglobin as peroxidase
    • Wu H: Studies on hemoglobin: ultra-method for determination of hemoglobin as peroxidase. Biochem J 1923; 2:189
    • (1923) Biochem J , vol.2 , pp. 189
    • Wu, H.1
  • 3
    • 0001237653 scopus 로고
    • A modification of the benzidine method for measurement of hemoglobin in plasma and urine
    • Crosby WH, Furth FW: A modification of the benzidine method for measurement of hemoglobin in plasma and urine. Blood 1956; 11:380
    • (1956) Blood , vol.11 , pp. 380
    • Crosby, W.H.1    Furth, F.W.2
  • 4
    • 0017328337 scopus 로고
    • Use of tetramethylbenzidine in plasma hemoglobin assay
    • Standefer JC, Vanderjagt D: Use of tetramethylbenzidine in plasma hemoglobin assay. Clin Chem 1977; 23:749-751
    • (1977) Clin Chem , vol.23 , pp. 749-751
    • Standefer, J.C.1    Vanderjagt, D.2
  • 5
    • 0018665544 scopus 로고
    • Tetramethylbenzidine - A substitute for benzidine in hemoglobin analysis
    • Lijana RC, Williams MC: Tetramethylbenzidine - a substitute for benzidine in hemoglobin analysis. J Laboratory Clin Med 1979; 94:266-276
    • (1979) J Laboratory Clin Med , vol.94 , pp. 266-276
    • Lijana, R.C.1    Williams, M.C.2
  • 6
    • 0029937808 scopus 로고    scopus 로고
    • Recommendations for reference method for haemoglobinometry in human blood (ICSH Standard 1995) and specifications for international haemiglobinocyanide standard, 4th edition
    • Zwart A, van Assendelft OW, Bull BS, England JM, Lewis SM, Zijlstra WG: Recommendations for Reference Method for Haemoglobinometry in Human Blood (ICSH Standard 1995) and Specifications for International Haemiglobinocyanide Standard, 4th edition. J Clin Pathol 1996; 49:271-274
    • (1996) J Clin Pathol , vol.49 , pp. 271-274
    • Zwart, A.1    Van Assendelft, O.W.2    Bull, B.S.3    England, J.M.4    Lewis, S.M.5    Zijlstra, W.G.6
  • 7
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland LM, Altman DG: Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; i:307-310
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, L.M.1    Altman, D.G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.