메뉴 건너뛰기




Volumn 26, Issue 4, 2011, Pages 423-427

Determination of capillary hemoglobin levels using the HemoCue system in intensive care patients

Author keywords

Anemia; HemoCue; Hemoglobin measurement; Hemoglobinometer; Intensive care

Indexed keywords

HEMOGLOBIN;

EID: 79960699992     PISSN: 08839441     EISSN: 15578615     Source Type: Journal    
DOI: 10.1016/j.jcrc.2010.08.012     Document Type: Article
Times cited : (34)

References (15)
  • 1
    • 0030593838 scopus 로고    scopus 로고
    • Effect of anaemia and cardiovascular disease on surgical mortality and morbidity
    • Carson J.L., Duff A., Poses R.M., et al. Effect of anaemia and cardiovascular disease on surgical mortality and morbidity. Lancet 1996, 348:1055-1060.
    • (1996) Lancet , vol.348 , pp. 1055-1060
    • Carson, J.L.1    Duff, A.2    Poses, R.M.3
  • 2
    • 0035092672 scopus 로고    scopus 로고
    • Nutritional deficiencies and blunted erythropoietin response as causes of the anemia of critical illness
    • Rodriguez R.M., Corwin H.L., Gettinger A., et al. Nutritional deficiencies and blunted erythropoietin response as causes of the anemia of critical illness. J Crit Care 2001, 16:36-41.
    • (2001) J Crit Care , vol.16 , pp. 36-41
    • Rodriguez, R.M.1    Corwin, H.L.2    Gettinger, A.3
  • 3
    • 0033397526 scopus 로고    scopus 로고
    • Important role of nondiagnostic blood loss and blunted erythropoietic response in the anemia of medical intensive care patients
    • von Ahsen N., Muller C., Serke S., et al. Important role of nondiagnostic blood loss and blunted erythropoietic response in the anemia of medical intensive care patients. Crit Care Med 1999, 27:2630-2639.
    • (1999) Crit Care Med , vol.27 , pp. 2630-2639
    • von Ahsen, N.1    Muller, C.2    Serke, S.3
  • 4
    • 0029969747 scopus 로고    scopus 로고
    • Blood loss from diagnostic laboratory tests performed in intensive care units. Preliminary study
    • Alazia M., Colavolpe J.C., Botti G., et al. Blood loss from diagnostic laboratory tests performed in intensive care units. Preliminary study. Ann Fr Anesth Reanim 1996, 15:1004-1007.
    • (1996) Ann Fr Anesth Reanim , vol.15 , pp. 1004-1007
    • Alazia, M.1    Colavolpe, J.C.2    Botti, G.3
  • 5
    • 0023044723 scopus 로고
    • Medical vampires
    • Burnum J.F. Medical vampires. N Engl J Med 1986, 314:1250-1251.
    • (1986) N Engl J Med , vol.314 , pp. 1250-1251
    • Burnum, J.F.1
  • 6
    • 0023182451 scopus 로고
    • Evaluation of portable haemoglobinometer in general practice
    • Neville R.G. Evaluation of portable haemoglobinometer in general practice. Br Med J (Clin Res Ed) 1987, 294:1263-1265.
    • (1987) Br Med J (Clin Res Ed) , vol.294 , pp. 1263-1265
    • Neville, R.G.1
  • 7
    • 0026541825 scopus 로고
    • A clinical evaluation of the Hemocue haemoglobinometer using capillary, venous and arterial samples
    • Chen P.P., Short T.G., Leung D.H., et al. A clinical evaluation of the Hemocue haemoglobinometer using capillary, venous and arterial samples. Anaesth Intensive Care 1992, 20:497-500.
    • (1992) Anaesth Intensive Care , vol.20 , pp. 497-500
    • Chen, P.P.1    Short, T.G.2    Leung, D.H.3
  • 8
    • 33846852614 scopus 로고    scopus 로고
    • Reliability of HemoCue in patients with gastrointestinal bleeding
    • Van de Louw A., Lasserre N., Drouhin F., et al. Reliability of HemoCue in patients with gastrointestinal bleeding. Intensive Care Med 2007, 33:355-358.
    • (2007) Intensive Care Med , vol.33 , pp. 355-358
    • Van de Louw, A.1    Lasserre, N.2    Drouhin, F.3
  • 9
    • 1542465774 scopus 로고    scopus 로고
    • Evaluation of the blood analyzer Beckman Coulter LH 750: analytic performance, decision rules
    • Amouroux I., Balay M., Marfaing-Koka A. Evaluation of the blood analyzer Beckman Coulter LH 750: analytic performance, decision rules. Ann Biol Clin (Paris) 2003, 61:576-584.
    • (2003) Ann Biol Clin (Paris) , vol.61 , pp. 576-584
    • Amouroux, I.1    Balay, M.2    Marfaing-Koka, A.3
  • 10
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland J.M., Altman D.G. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986, 1:307-310.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 11
    • 0023792468 scopus 로고
    • A comparison between haematological parameters in 'capillary' and venous blood from healthy adults
    • Daae L.N., Halvorsen S., Mathisen P.M., et al. A comparison between haematological parameters in 'capillary' and venous blood from healthy adults. Scand J Clin Lab Invest 1988, 48:723-726.
    • (1988) Scand J Clin Lab Invest , vol.48 , pp. 723-726
    • Daae, L.N.1    Halvorsen, S.2    Mathisen, P.M.3
  • 12
    • 0035724137 scopus 로고    scopus 로고
    • Comparison of blood counts in venous, fingertip and arterial blood and their measurement variation
    • Yang Z.W., Yang S.H., Chen L., et al. Comparison of blood counts in venous, fingertip and arterial blood and their measurement variation. Clin Lab Haematol 2001, 23:155-159.
    • (2001) Clin Lab Haematol , vol.23 , pp. 155-159
    • Yang, Z.W.1    Yang, S.H.2    Chen, L.3
  • 13
    • 4544365096 scopus 로고    scopus 로고
    • Comparison between the HemoCue and an automated counter for measuring hemoglobin
    • Paiva Ade A., Rondo P.H., Silva S.S., et al. Comparison between the HemoCue and an automated counter for measuring hemoglobin. Rev Saude Publica 2004, 38:585-587.
    • (2004) Rev Saude Publica , vol.38 , pp. 585-587
    • Paiva Ade, A.1    Rondo, P.H.2    Silva, S.S.3
  • 14
    • 0031283092 scopus 로고    scopus 로고
    • Hemocue, an accurate bedside method of hemoglobin measurement?
    • Rippmann C.E., Nett P.C., Popovic D., et al. Hemocue, an accurate bedside method of hemoglobin measurement?. J Clin Monit 1997, 13:373-377.
    • (1997) J Clin Monit , vol.13 , pp. 373-377
    • Rippmann, C.E.1    Nett, P.C.2    Popovic, D.3
  • 15
    • 0032973798 scopus 로고    scopus 로고
    • Precision, accuracy, and reliability of hemoglobin assessment with use of capillary blood
    • Morris S.S., Ruel M.T., Cohen R.J., et al. Precision, accuracy, and reliability of hemoglobin assessment with use of capillary blood. Am J Clin Nutr 1999, 69:1243-1248.
    • (1999) Am J Clin Nutr , vol.69 , pp. 1243-1248
    • Morris, S.S.1    Ruel, M.T.2    Cohen, R.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.