메뉴 건너뛰기




Volumn 6, Issue 3, 2017, Pages 218-222

Rapid rule out of acute myocardial infarction: novel biomarker-based strategies

Author keywords

Acute myocardial infarction; diagnosis; rule out

Indexed keywords

BIOLOGICAL MARKER; COPEPTIN; TROPONIN; TROPONIN I; TROPONIN T;

EID: 85034967540     PISSN: 20488726     EISSN: 20488734     Source Type: Journal    
DOI: 10.1177/2048872616653229     Document Type: Article
Times cited : (68)

References (26)
  • 1
    • 84925480988 scopus 로고    scopus 로고
    • Early discharge using single cardiac troponin and copeptin testing in patients with suspected ACS: a randomized, controlled clinical process study
    • Möckel M, Searle J, Hamm C. Early discharge using single cardiac troponin and copeptin testing in patients with suspected ACS: a randomized, controlled clinical process study. Eur Heart J 2015; 36: 369–376.
    • (2015) Eur Heart J , vol.36 , pp. 369-376
    • Möckel, M.1    Searle, J.2    Hamm, C.3
  • 2
    • 69349100568 scopus 로고    scopus 로고
    • Sensitive troponin I assay in early diagnosis of acute myocardial infarction
    • Keller T, Zeller T, Peetz D. Sensitive troponin I assay in early diagnosis of acute myocardial infarction. N Engl J Med 2009; 361: 868–877.
    • (2009) N Engl J Med , vol.361 , pp. 868-877
    • Keller, T.1    Zeller, T.2    Peetz, D.3
  • 3
    • 84930382031 scopus 로고    scopus 로고
    • Two-hour algorithm for triage toward rule-out and rule-in of acute myocardial infarction using high-sensitivity cardiac troponin T
    • Reichlin T, Cullen L, Parsonage WA. Two-hour algorithm for triage toward rule-out and rule-in of acute myocardial infarction using high-sensitivity cardiac troponin T. Am J Med 2015; 128: 369–379.
    • (2015) Am J Med , vol.128 , pp. 369-379
    • Reichlin, T.1    Cullen, L.2    Parsonage, W.A.3
  • 4
    • 79960431247 scopus 로고    scopus 로고
    • Utility of absolute and relative changes in cardiac troponin concentrations in the early diagnosis of acute myocardial infarction
    • Reichlin T, Irfan A, Twerenbold R. Utility of absolute and relative changes in cardiac troponin concentrations in the early diagnosis of acute myocardial infarction. Circulation 2011; 124: 136–145.
    • (2011) Circulation , vol.124 , pp. 136-145
    • Reichlin, T.1    Irfan, A.2    Twerenbold, R.3
  • 5
    • 84866103717 scopus 로고    scopus 로고
    • One 10 hour rule-out and rule-in of acute myocardial infarction using high-sensitivity cardiac troponin t
    • Reichlin T, Schindler C, Drexler B. One 10 hour rule-out and rule-in of acute myocardial infarction using high-sensitivity cardiac troponin t. Arch Intern Med 2012; 172: 1211–1218.
    • (2012) Arch Intern Med , vol.172 , pp. 1211-1218
    • Reichlin, T.1    Schindler, C.2    Drexler, B.3
  • 6
    • 84906258958 scopus 로고    scopus 로고
    • Diagnostic accuracy of combined cardiac troponin and copeptin assessment for early rule-out of myocardial infarction: a systematic review and meta-analysis
    • Raskovalova T, Twerenbold R, Collinson PO. Diagnostic accuracy of combined cardiac troponin and copeptin assessment for early rule-out of myocardial infarction: a systematic review and meta-analysis. Eur Heart J Acute Cardiovasc Care 2014; 3: 18–27.
    • (2014) Eur Heart J Acute Cardiovasc Care , vol.3 , pp. 18-27
    • Raskovalova, T.1    Twerenbold, R.2    Collinson, P.O.3
  • 7
    • 84929191797 scopus 로고    scopus 로고
    • Incremental value of copeptin to highly sensitive cardiac troponin I for rapid rule-out of myocardial infarction
    • Wildi K, Zellweger C, Twerenbold R. Incremental value of copeptin to highly sensitive cardiac troponin I for rapid rule-out of myocardial infarction. Int J Cardiol 2015; 190: 170–176.
    • (2015) Int J Cardiol , vol.190 , pp. 170-176
    • Wildi, K.1    Zellweger, C.2    Twerenbold, R.3
  • 8
    • 84971619896 scopus 로고    scopus 로고
    • 2015 ESC Guidelines for the management of acute coronary syndromes in patients presenting without persistent ST-segment elevation: Task Force for the Management of Acute Coronary Syndromes in Patients Presenting without Persistent ST-Segment Elevation of the European Society of Cardiology (ESC)
    • Roffi M, Patrono C, Collet JP. 2015 ESC Guidelines for the management of acute coronary syndromes in patients presenting without persistent ST-segment elevation: Task Force for the Management of Acute Coronary Syndromes in Patients Presenting without Persistent ST-Segment Elevation of the European Society of Cardiology (ESC). Eur Heart J 2016; 37: 267–315.
    • (2016) Eur Heart J , vol.37 , pp. 267-315
    • Roffi, M.1    Patrono, C.2    Collet, J.P.3
  • 9
    • 84868089883 scopus 로고    scopus 로고
    • Determination of 19 cardiac troponin I and T assay 99th percentile values from a common presumably healthy population
    • Apple FS, Ler R, Murakami MM. Determination of 19 cardiac troponin I and T assay 99th percentile values from a common presumably healthy population. Clin Chem 2012; 58(11): 1574–1581.
    • (2012) Clin Chem , vol.58 , Issue.11 , pp. 1574-1581
    • Apple, F.S.1    Ler, R.2    Murakami, M.M.3
  • 10
    • 84861607690 scopus 로고    scopus 로고
    • 2-Hour accelerated diagnostic protocol to assess patients with chest pain symptoms using contemporary troponins as the only biomarker
    • Than M, Cullen L, Aldous S. 2-Hour accelerated diagnostic protocol to assess patients with chest pain symptoms using contemporary troponins as the only biomarker. J Am Coll Cardiol 2012; 59: 2091–2098.
    • (2012) J Am Coll Cardiol , vol.59 , pp. 2091-2098
    • Than, M.1    Cullen, L.2    Aldous, S.3
  • 11
    • 84881480711 scopus 로고    scopus 로고
    • Validation of high-sensitivity troponin I in a 2-h diagnostic strategy to assess 30-day outcomes in emergency-department patients with possible acute coronary syndrome
    • Cullen L, Mueller C, Parsonage WA. Validation of high-sensitivity troponin I in a 2-h diagnostic strategy to assess 30-day outcomes in emergency-department patients with possible acute coronary syndrome. J Am Coll Cardiol 2013; 62: 1242–1249.
    • (2013) J Am Coll Cardiol , vol.62 , pp. 1242-1249
    • Cullen, L.1    Mueller, C.2    Parsonage, W.A.3
  • 12
    • 84889647667 scopus 로고    scopus 로고
    • A 2-hour diagnostic protocol for possible cardiac chest pain in the emergency department: a randomized clinical trial
    • Than M, Aldous S, Lord SJ. A 2-hour diagnostic protocol for possible cardiac chest pain in the emergency department: a randomized clinical trial. JAMA Intern Med 2014; 174(1): 51–58.
    • (2014) JAMA Intern Med , vol.174 , Issue.1 , pp. 51-58
    • Than, M.1    Aldous, S.2    Lord, S.J.3
  • 13
    • 84933529143 scopus 로고    scopus 로고
    • Accelerated diagnostic protocol using high-sensitivity cardiac troponin T in acute chest pain patients
    • Meller B, Cullen L, Parsonage WA. Accelerated diagnostic protocol using high-sensitivity cardiac troponin T in acute chest pain patients. Int J Cardiol 2015; 184: 208–215.
    • (2015) Int J Cardiol , vol.184 , pp. 208-215
    • Meller, B.1    Cullen, L.2    Parsonage, W.A.3
  • 14
    • 84964696078 scopus 로고    scopus 로고
    • Prospective validation of a 1-hour algorithm to rule-out and rule-in acute myocardial infarction using a high-sensitivity cardiac troponin T assay
    • Reichlin T, Twerenbold R, Wildi K. Prospective validation of a 1-hour algorithm to rule-out and rule-in acute myocardial infarction using a high-sensitivity cardiac troponin T assay. CMAJ 2015; 187(8): E243–E252.
    • (2015) CMAJ , vol.187 , Issue.8 , pp. E243-E252
    • Reichlin, T.1    Twerenbold, R.2    Wildi, K.3
  • 15
    • 84937812627 scopus 로고    scopus 로고
    • One-hour rule-in and rule-out of acute myocardial infarction using high-sensitivity cardiac troponin I
    • Rubini Gimenez M, Twerenbold R, Jaeger C. One-hour rule-in and rule-out of acute myocardial infarction using high-sensitivity cardiac troponin I. Am J Med 2015; 128: 861–870.
    • (2015) Am J Med , vol.128 , pp. 861-870
    • Rubini Gimenez, M.1    Twerenbold, R.2    Jaeger, C.3
  • 16
    • 84954306118 scopus 로고    scopus 로고
    • Multicenter evaluation of a 0-hour/1-hour algorithm in the diagnosis of myocardial infarction with high-sensitivity cardiac troponin T
    • January, 8,. pii: [Epub ahead of print]
    • Mueller C, Giannitsis E, Christ M.; for the TRAPID-AMI Investigators. Multicenter evaluation of a 0-hour/1-hour algorithm in the diagnosis of myocardial infarction with high-sensitivity cardiac troponin T. Ann Emerg Med 2016 January 8. pii: S0196-0644(15)01501-2. doi: 10.1016/j.annemergmed.2015.11.013. [Epub ahead of print]
    • (2016) Ann Emerg Med
    • Mueller, C.1    Giannitsis, E.2    Christ, M.3
  • 17
    • 84951845137 scopus 로고    scopus 로고
    • One-hour rule-in and rule-out of acute myocardial infarction using high-sensitivity cardiac troponin I
    • Jaeger C, Wildi K, Twerenbold R. One-hour rule-in and rule-out of acute myocardial infarction using high-sensitivity cardiac troponin I. Am Heart J 2016; 171: 92–102.
    • (2016) Am Heart J , vol.171 , pp. 92-102
    • Jaeger, C.1    Wildi, K.2    Twerenbold, R.3
  • 18
    • 84902138306 scopus 로고    scopus 로고
    • Undetectable high sensitivity cardiac troponin T level in the emergency department and risk of myocardial infarction
    • Bandstein N, Ljung R, Johansson M. Undetectable high sensitivity cardiac troponin T level in the emergency department and risk of myocardial infarction. J Am Coll Cardiol 2014; 63: 2569–2578.
    • (2014) J Am Coll Cardiol , vol.63 , pp. 2569-2578
    • Bandstein, N.1    Ljung, R.2    Johansson, M.3
  • 19
    • 84921908439 scopus 로고    scopus 로고
    • Diagnostic accuracy of single baseline measurement of Elecsys Troponin T high-sensitive assay for diagnosis of acute myocardial infarction in emergency department: systematic review and meta-analysis
    • Zhelev Z, Hyde C, Youngman E. Diagnostic accuracy of single baseline measurement of Elecsys Troponin T high-sensitive assay for diagnosis of acute myocardial infarction in emergency department: systematic review and meta-analysis. BMJ 2015; 350: h15. doi: 10.1136/bmj.h15.
    • (2015) BMJ , vol.350 , pp. h15
    • Zhelev, Z.1    Hyde, C.2    Youngman, E.3
  • 20
    • 84937417944 scopus 로고    scopus 로고
    • High-sensitivity cardiac troponin T concentrations below the limit of detection to exclude acute myocardial infarction: a prospective evaluation
    • Body R, Burrows G, Carley S. High-sensitivity cardiac troponin T concentrations below the limit of detection to exclude acute myocardial infarction: a prospective evaluation. Clin Chem 2015; 61(7): 983–989.
    • (2015) Clin Chem , vol.61 , Issue.7 , pp. 983-989
    • Body, R.1    Burrows, G.2    Carley, S.3
  • 21
    • 84960327828 scopus 로고    scopus 로고
    • High-sensitivity cardiac troponin I at presentation in patients with suspected acute coronary syndrome: a cohort study
    • December, 19, 8, October, 2015,.,. Epub ahead of print
    • Shah AS, Anand A, Sandoval Y.; High-STEACS investigators. High-sensitivity cardiac troponin I at presentation in patients with suspected acute coronary syndrome: a cohort study. Lancet 2015 December 19; 386(10012): 2481–2488. doi: 10.1016/S0140-6736(15)00391-8. Epub ahead of print 8 October 2015.
    • (2015) Lancet , vol.386 , Issue.10012 , pp. 2481-2488
    • Shah, A.S.1    Anand, A.2    Sandoval, Y.3
  • 22
    • 85164551953 scopus 로고    scopus 로고
    • Two-hour algorithm for triage towards rule-out and rule-in of acute myocardial infarction by use of high-sensitivity cardiac troponin I
    • 21, January,. Epub ahead of print,. pii: clinchem
    • Boeddinghaus J, Reichlin T, Cullen L. Two-hour algorithm for triage towards rule-out and rule-in of acute myocardial infarction by use of high-sensitivity cardiac troponin I. Clin Chem. Epub ahead of print 21 January 2016. pii: clinchem.2015.249508.
    • (2016) Clin Chem , vol.2015 , pp. 249508
    • Boeddinghaus, J.1    Reichlin, T.2    Cullen, L.3
  • 23
    • 84957999136 scopus 로고    scopus 로고
    • Characterization of the observe zone of the ESC 2015 high-sensitivity cardiac troponin 0 h/1 h-algorithm for the early diagnosis of acute myocardial infarction
    • Nestelberger T, Wildi K, Boeddinghaus J. Characterization of the observe zone of the ESC 2015 high-sensitivity cardiac troponin 0 h/1 h-algorithm for the early diagnosis of acute myocardial infarction. Int J Cardiol 2016; 207: 238–245.
    • (2016) Int J Cardiol , vol.207 , pp. 238-245
    • Nestelberger, T.1    Wildi, K.2    Boeddinghaus, J.3
  • 24
    • 79959723393 scopus 로고    scopus 로고
    • Biological variation and reference change value of high-sensitivity troponin T in healthy individuals during short and intermediate follow-up periods
    • Frankenstein L, Wu AH, Hallermayer K. Biological variation and reference change value of high-sensitivity troponin T in healthy individuals during short and intermediate follow-up periods. Clin Chem 2011; 57(7): 1068–1071.
    • (2011) Clin Chem , vol.57 , Issue.7 , pp. 1068-1071
    • Frankenstein, L.1    Wu, A.H.2    Hallermayer, K.3
  • 25
    • 84868105856 scopus 로고    scopus 로고
    • Clinical implications of a recent adjustment to the high sensitivity cardiac troponin T assay: user beware
    • Apple FS, Jaffe AS. Clinical implications of a recent adjustment to the high sensitivity cardiac troponin T assay: user beware. Clin Chem 2012; 58(11): 1599–1600.
    • (2012) Clin Chem , vol.58 , Issue.11 , pp. 1599-1600
    • Apple, F.S.1    Jaffe, A.S.2
  • 26
    • 34547110373 scopus 로고    scopus 로고
    • The effect of freezing and long-term storage on the stability of cardiac troponin T
    • Basit M, Bakshi N, Hashem M. The effect of freezing and long-term storage on the stability of cardiac troponin T. Am J Clin Pathol 2007; 128(1): 164–167.
    • (2007) Am J Clin Pathol , vol.128 , Issue.1 , pp. 164-167
    • Basit, M.1    Bakshi, N.2    Hashem, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.