메뉴 건너뛰기




Volumn 190, Issue 1, 2015, Pages 170-176

Incremental value of copeptin to highly sensitive cardiac Troponin i for rapid rule-out of myocardial infarction

Author keywords

Acute myocardial infarction; Copeptin; Highly sensitive Troponin I; Sensitivity and specificity

Indexed keywords

ANGIOTENSIN RECEPTOR ANTAGONIST; ANTITHROMBOCYTIC AGENT; BETA ADRENERGIC RECEPTOR BLOCKING AGENT; COPEPTIN; DIPEPTIDYL CARBOXYPEPTIDASE INHIBITOR; HYDROXYMETHYLGLUTARYL COENZYME A REDUCTASE INHIBITOR; TROPONIN I; BIOLOGICAL MARKER; GLYCOPEPTIDE;

EID: 84929191797     PISSN: 01675273     EISSN: 18741754     Source Type: Journal    
DOI: 10.1016/j.ijcard.2015.04.133     Document Type: Article
Times cited : (40)

References (42)
  • 1
    • 0030996001 scopus 로고    scopus 로고
    • Global mortality disability, and the contribution of risk factors: Global burden of disease study
    • C.J. Murray, A.D. Lopez, Global mortality, disability, and the contribution of risk factors: Global Burden of Disease Study, Lancet 349 (1997) 1436-1442.
    • (1997) Lancet , vol.349 , pp. 1436-1442
    • Murray, C.J.1    Lopez, A.D.2
  • 6
    • 84857937071 scopus 로고    scopus 로고
    • High-sensitive troponin T measurements: What do we gain and what are the challenges?
    • R. Twerenbold, A. Jaffe, T. Reichlin, M. Reiter, C. Mueller, High-sensitive troponin T measurements: What do we gain and what are the challenges? Eur. Heart J. 33 (2012) 579-586.
    • (2012) Eur. Heart J. , vol.33 , pp. 579-586
    • Twerenbold, R.1    Jaffe, A.2    Reichlin, T.3    Reiter, M.4    Mueller, C.5
  • 7
    • 77956943712 scopus 로고    scopus 로고
    • Recommendations for the use of cardiac troponin measurement in acute cardiac care
    • K. Thygesen, J. Mair, H. Katus,M. Plebani, P. Venge, P. Collinson, et al., Recommendations for the use of cardiac troponin measurement in acute cardiac care, Eur. Heart J. 31 (2010) 2197-2204.
    • (2010) Eur. Heart J. , vol.31 , pp. 2197-2204
    • Thygesen, K.1    Mair, J.2    Katusm. Plebani, H.3    Venge, P.4    Collinson, P.5
  • 8
    • 84856003210 scopus 로고    scopus 로고
    • Comparison of the temporal release pattern of copeptin with conventional biomarkers in acute myocardial infarction
    • Y. Gu, A. Voors, F. Zijlstra, H. Hillege, J. Struck, S. Masson, et al., Comparison of the temporal release pattern of copeptin with conventional biomarkers in acute myocardial infarction, Clin. Res. Cardiol. 100 (2011) 1069-1076.
    • (2011) Clin. Res. Cardiol. , vol.100 , pp. 1069-1076
    • Gu, Y.1    Voors, A.2    Zijlstra, F.3    Hillege, H.4    Struck, J.5    Masson, S.6
  • 10
    • 84879828614 scopus 로고    scopus 로고
    • Copeptin helps in the early detection of patients with acute myocardial infarction: Primary results of the CHOPIN trial (Copeptin Helps in the early detection of Patients with acute myocardial INfarction)
    • A. Maisel, C. Mueller, S.-X. Neath, R.H. Christenson, N.G. Morgenthaler, J. McCord, et al., Copeptin helps in the early detection of patients with acute myocardial infarction: Primary results of the CHOPIN trial (Copeptin Helps in the early detection Of Patients with acute myocardial INfarction), J. Am. Coll. Cardiol. 62 (2013) 150-160.
    • (2013) J. Am. Coll. Cardiol. , vol.62 , pp. 150-160
    • Maisel, A.1    Mueller, C.2    Neath, S.-X.3    Christenson, R.H.4    Morgenthaler, N.G.5    McCord, J.6
  • 12
    • 84879788026 scopus 로고    scopus 로고
    • Comparison of the performances of cardiac troponins, including sensitive assays, and copeptin in the diagnostic of acute myocardial infarction and long-term prognosis between women and men
    • C. Balmelli, C.Meune, R. Twerenbold, T. Reichlin, S. Rieder, B. Drexler, et al., Comparison of the performances of cardiac troponins, including sensitive assays, and copeptin in the diagnostic of acute myocardial infarction and long-term prognosis between women and men, Am. Heart J. 166 (2013) 30-37.
    • (2013) Am Heart J. , vol.166 , pp. 30-37
    • Balmelli, C.1    Meune, C.2    Twerenbold, R.3    Reichlin, T.4    Rieder, S.5    Drexler, B.6
  • 13
    • 84856069184 scopus 로고    scopus 로고
    • Counterpoint: Detection of myocardial infarction-is it all troponin? Role of new markers
    • C. Mueller, Counterpoint: Detection of myocardial infarction-is it all troponin? Role of new markers, Clin. Chem. 58 (2012) 162-164.
    • (2012) Clin. Chem. , vol.58 , pp. 162-164
    • Mueller, C.1
  • 14
    • 84856012705 scopus 로고    scopus 로고
    • Combined determination of highly sensitive troponin T and copeptin for early exclusion of acute myocardial infarction: First experience in an emergency department of a general hospital
    • U. Lotze, H. Lemm, A. Heyer, K. Muller, Combined determination of highly sensitive troponin T and copeptin for early exclusion of acute myocardial infarction: First experience in an emergency department of a general hospital, Vasc. Health Risk Manag. 7 (2011) 509-515.
    • (2011) Vasc. Health Risk Manag. , vol.7 , pp. 509-515
    • Lotze, U.1    Lemm, H.2    Heyer, A.3    Muller, K.4
  • 15
    • 79961087161 scopus 로고    scopus 로고
    • Copeptin does not add diagnostic information to high-sensitivity troponin T in low-to intermediate-risk patients with acute chest pain: Results from the rule out myocardial infarction by computed tomography (ROMICAT) study
    • M. Karakas, J.L. Januzzi, J. Meyer, H. Lee, C.L. Schlett, Q.A. Truong, et al., Copeptin does not add diagnostic information to high-sensitivity troponin T in low-to intermediate-risk patients with acute chest pain: Results from the rule out myocardial infarction by computed tomography (ROMICAT) study, Clin. Chem. 57 (2011) 1137-1145.
    • (2011) Clin. Chem. , vol.57 , pp. 1137-1145
    • Karakas, M.1    Januzzi, J.L.2    Meyer, J.3    Lee, H.4    Schlett, C.L.5    Truong, Q.A.6
  • 16
    • 84899984249 scopus 로고    scopus 로고
    • The utility of copeptin in the emergency department for non-ST-elevation myocardial infarction rapid rule out: COPED-MIRRO study
    • P. Llorens, M. Sánchez, P. Herrero, F.J. Martín-Sánchez, P. Piñera, O. Miró, The utility of copeptin in the emergency department for non-ST-elevation myocardial infarction rapid rule out: COPED-MIRRO study, Eur. J. Emerg. Med. 21 (2013) 220-229.
    • (2013) Eur. J. Emerg. Med. , vol.21 , pp. 220-229
    • Llorens, P.1    Sánchez, M.2    Herrero, P.3    Martín-Sánchez, F.J.4    Piñera, P.5    Miró, O.6
  • 17
    • 84884818044 scopus 로고    scopus 로고
    • Impact of copeptin on diagnosis, risk stratification, and intermediate-term prognosis of acute coronary syndromes
    • D. Afzali, M. Erren, H.-J. Pavenstädt, J.O. Vollert, S. Hertel, J. Waltenberger, et al., Impact of copeptin on diagnosis, risk stratification, and intermediate-term prognosis of acute coronary syndromes, Clin. Res. Cardiol. 102 (2013) 755-763.
    • (2013) Clin. Res. Cardiol. , vol.102 , pp. 755-763
    • Afzali, D.1    Erren, M.2    Pavenstädt, H.-J.3    Vollert, J.O.4    Hertel, S.5    Waltenberger, J.6
  • 18
    • 84876744807 scopus 로고    scopus 로고
    • Copeptin improves the diagnostic performance of sensitive troponin IUltra but cannot rapidly rule out non-ST-elevation myocardial infarction at presentation to an emergency department
    • S. Charpentier, B. Lepage, F. Maupas-Schwalm, C. Cinq-Frais, M. Bichard-Bréaud, J.M. Botella, et al., Copeptin improves the diagnostic performance of sensitive troponin IUltra but cannot rapidly rule out non-ST-elevation myocardial infarction at presentation to an emergency department, Ann. Emerg. Med. 61 (2013) 549.e1-549.e58.
    • (2013) Ann. Emerg. Med. , vol.61 , pp. 549e1-549e58
    • Charpentier, S.1    Lepage, B.2    Maupas-Schwalm, F.3    Cinq-Frais, C.4    Bichard-Bréaud, M.5    Botella, J.M.6
  • 19
    • 79960431247 scopus 로고    scopus 로고
    • Utility of absolute and relative changes in cardiac troponin concentrations in the early diagnosis of acute myocardial infarction
    • T. Reichlin, A. Irfan, R. Twerenbold, M. Reiter, W. Hochholzer, H. Burkhalter, et al., Utility of absolute and relative changes in cardiac troponin concentrations in the early diagnosis of acute myocardial infarction, Circulation 124 (2011) 136-145.
    • (2011) Circulation , vol.124 , pp. 136-145
    • Reichlin, T.1    Irfan, A.2    Twerenbold, R.3    Reiter, M.4    Hochholzer, W.5    Burkhalter, H.6
  • 20
    • 84860132016 scopus 로고    scopus 로고
    • Early diagnosis of acute myocardial infarction in patients with pre-existing coronary artery disease using more sensitive cardiac troponin assays
    • M. Reiter, R. Twerenbold, T. Reichlin, B. Benz, P. Haaf, J. Meissner, et al., Early diagnosis of acute myocardial infarction in patients with pre-existing coronary artery disease using more sensitive cardiac troponin assays, Eur. Heart J. 33 (2011) 988-997.
    • (2011) Eur. Heart J. , vol.33 , pp. 988-997
    • Reiter, M.1    Twerenbold, R.2    Reichlin, T.3    Benz, B.4    Haaf, P.5    Meissner, J.6
  • 21
    • 84863609086 scopus 로고    scopus 로고
    • Highsensitivity cardiac troponin in the distinction of acute myocardial infarction from acute cardiac noncoronary artery disease
    • P. Haaf, B. Drexler, T. Reichlin, R. Twerenbold, M. Reiter, J. Meissner, et al., Highsensitivity cardiac troponin in the distinction of acute myocardial infarction from acute cardiac noncoronary artery disease, Circulation 126 (2012) 31-40.
    • (2012) Circulation , vol.126 , pp. 31-40
    • Haaf, P.1    Drexler, B.2    Reichlin, T.3    Twerenbold, R.4    Reiter, M.5    Meissner, J.6
  • 22
    • 84866103717 scopus 로고    scopus 로고
    • One-hour rule-out and rule-in of acute myocardial infarction using highsensitivity cardiac troponin T
    • T. Reichlin, C. Schindler, B. Drexler, R. Twerenbold, M. Reiter, C. Zellweger, et al., One-hour rule-out and rule-in of acute myocardial infarction using highsensitivity cardiac troponin T, Arch. Intern. Med. 172 (2012) 1211-1218.
    • (2012) Arch. Intern. Med. , vol.172 , pp. 1211-1218
    • Reichlin, T.1    Schindler, C.2    Drexler, B.3    Twerenbold, R.4    Reiter, M.5    Zellweger, C.6
  • 23
    • 35448971466 scopus 로고    scopus 로고
    • Joint ESCAAHAWHFTF for the R of MI. Universal definition of myocardial infarction
    • K. Thygesen, J.S. Alpert, H.D.White, Joint ESCAAHAWHFTF for the R of MI. Universal definition of myocardial infarction, Eur. Heart J. 28 (2007) 2525-2538.
    • (2007) Eur. Heart J. , vol.28 , pp. 2525-2538
    • Thygesen, K.1    Alpert, J.S.2    White, H.D.3
  • 25
    • 34548404811 scopus 로고    scopus 로고
    • National academy of clinical biochemistry and ifcc committee for standardization of markers of cardiac damage laboratory medicine practice guidelines: Analytical issues for biomarkers of heart failure
    • F.S. Apple, A.H.Wu, A.S. Jaffe, M. Panteghini, R.H. Christenson, C.P. Cannon, et al., National Academy of Clinical Biochemistry and IFCC Committee for Standardization of Markers of Cardiac Damage Laboratory Medicine practice guidelines: Analytical issues for biomarkers of heart failure, Circulation 116 (2007) e95-e98.
    • (2007) Circulation , vol.116 , pp. e95-e98
    • Apple, F.S.1    Wu, A.H.2    Jaffe, A.S.3    Panteghini, M.4    Christenson, R.H.5    Cannon, C.P.6
  • 26
    • 33947662426 scopus 로고    scopus 로고
    • Cardiac troponin monitoring for detection of myocardial infarction: Newer generation assays are here to stay
    • F.S. Apple, Cardiac troponin monitoring for detection of myocardial infarction: Newer generation assays are here to stay, Clin. Chim. Acta 380 (2007) 1-6.
    • (2007) Clin. Chim. Acta , vol.380 , pp. 1-6
    • Apple, F.S.1
  • 27
    • 42449136582 scopus 로고    scopus 로고
    • Use of the centaur tniultra assay for detection of myocardial infarction and adverse events in patients presenting with symptoms suggestive of acute coronary syndrome
    • F.S. Apple, S.W. Smith, L.A. Pearce, R. Ler, M.M. Murakami, Use of the Centaur TnIUltra assay for detection of myocardial infarction and adverse events in patients presenting with symptoms suggestive of acute coronary syndrome, Clin. Chem. 54 (2008) 723-728.
    • (2008) Clin. Chem. , vol.54 , pp. 723-728
    • Apple, F.S.1    Smith, S.W.2    Pearce, L.A.3    Ler, R.4    Murakami, M.M.5
  • 28
    • 34547918353 scopus 로고    scopus 로고
    • Earlier detection of myocardial injury in a preliminary evaluation using a new troponin i assay with improved sensitivity
    • S.E. Melanson, D.A. Morrow, P. Jarolim, Earlier detection of myocardial injury in a preliminary evaluation using a new troponin I assay with improved sensitivity, Am. J. Clin. Pathol. 128 (2007) 282-286.
    • (2007) Am. J. Clin. Pathol. , vol.128 , pp. 282-286
    • Melanson, S.E.1    Morrow, D.A.2    Jarolim, P.3
  • 29
    • 62149091831 scopus 로고    scopus 로고
    • Analytic and clinical utility of a nextgeneration, highly sensitive cardiac troponin i assay for early detection of myocardial injury
    • P.A. Kavsak, A.R. MacRae, M.J. Yerna, A.S. Jaffe, Analytic and clinical utility of a nextgeneration, highly sensitive cardiac troponin I assay for early detection of myocardial injury, Clin. Chem. 55 (2009) 573-577.
    • (2009) Clin. Chem. , vol.55 , pp. 573-577
    • Kavsak, P.A.1    Macrae, A.R.2    Yerna, M.J.3    Jaffe, A.S.4
  • 30
    • 31844445039 scopus 로고    scopus 로고
    • Performance evaluation and subsequent clinical experience with the Abbott Automated Architect STAT Troponin-I assay
    • Q. Lam, M. Black, O. Youdell, H. Spilsbury, H.-G. Schneider, Performance evaluation and subsequent clinical experience with the Abbott Automated Architect STAT Troponin-I assay, Clin. Chem. 52 (2006) 298-300.
    • (2006) Clin. Chem. , vol.52 , pp. 298-300
    • Lam, Q.1    Black, M.2    Youdell, O.3    Spilsbury, H.4    Schneider, H.-G.5
  • 31
    • 0023710206 scopus 로고
    • Comparing the areas under two or more correlated receiver operating characteristic curves: A nonparametric approach
    • E.R. DeLong, D.M. DeLong, D.L. Clarke-Pearson, Comparing the areas under two or more correlated receiver operating characteristic curves: A nonparametric approach, Biometrics 44 (1988) 837-845.
    • (1988) Biometrics , vol.44 , pp. 837-845
    • Delong, E.R.1    Delong, D.M.2    Clarke-Pearson, D.L.3
  • 32
    • 38849091997 scopus 로고    scopus 로고
    • Evaluating the added predictive ability of a newmarker: Fromarea under the ROC curve to reclassification and beyond
    • M.J. Pencina, R.B. D'Agostino Sr., R.B. D'Agostino Jr., R.S. Vasan, Evaluating the added predictive ability of a newmarker: Fromarea under the ROC curve to reclassification and beyond, Stat. Med. 27 (2008) 112-157.
    • (2008) Stat. Med. , vol.27 , pp. 112-157
    • Pencina, M.J.1    D'Agostino, R.B.2    D'Agostino, R.B.3    Vasan, R.S.4
  • 33
    • 84879056337 scopus 로고    scopus 로고
    • The combination of high sensitivity troponin T and copeptin facilitates early rule-out of ACS: A prospective observational study
    • J. Thelin, C. Borna, D. Erlinge, B. Ohlin, The combination of high sensitivity troponin T and copeptin facilitates early rule-out of ACS: A prospective observational study, BMC Cardiovasc. Disord. 13 (2013) 42.
    • (2013) BMC Cardiovasc. Disord. , vol.13 , pp. 42
    • Thelin, J.1    Borna, C.2    Erlinge, D.3    Ohlin, B.4
  • 34
    • 84883799405 scopus 로고    scopus 로고
    • Early rule out of acute myocardial infarction in ED patients: Value of combined high-sensitivity cardiac troponin T and ultrasensitive copeptin assays at admission
    • M. Sebbane, S. Lefebvre, N. Kuster, R. Jreige, E. Jacques, S. Badiou, et al., Early rule out of acute myocardial infarction in ED patients: Value of combined high-sensitivity cardiac troponin T and ultrasensitive copeptin assays at admission, Am. J. Emerg. Med. 31 (2013) 1302-1308.
    • (2013) Am. J. Emerg. Med. , vol.31 , pp. 1302-1308
    • Sebbane, M.1    Lefebvre, S.2    Kuster, N.3    Jreige, R.4    Jacques, E.5    Badiou, S.6
  • 35
    • 80053405636 scopus 로고    scopus 로고
    • Combined testing of high-sensitivity troponin T and copeptin on presentation at prespecified cutoffs improves rapid ruleout of non-ST-segment elevation myocardial infarction
    • E. Giannitsis, T. Kehayova,M. Vafaie, H.A. Katus, Combined testing of high-sensitivity troponin T and copeptin on presentation at prespecified cutoffs improves rapid ruleout of non-ST-segment elevation myocardial infarction, Clin. Chem. 57 (2011) 1452-1455.
    • (2011) Clin. Chem. , vol.57 , pp. 1452-1455
    • Giannitsis, E.1    Kehayova, T.2    Vafaie, M.3    Katus, H.A.4
  • 36
    • 80054785407 scopus 로고    scopus 로고
    • Copeptin and high sensitive troponin for a rapid rule out of acute myocardial infarction?
    • D. Giavarina, M. Carta, A. Fortunato,M.L. Wratten, O. Hartmann, G. Soffiati, Copeptin and high sensitive troponin for a rapid rule out of acute myocardial infarction? Clin. Lab. 57 (2011) 725-730.
    • (2011) Clin Lab. , vol.57 , pp. 725-730
    • Giavarina, D.1    Carta, M.2    Fortunatom, A.3    Wratten, M.L.4    Hartmann, O.5    Soffiati, G.6
  • 38
    • 84555195443 scopus 로고    scopus 로고
    • Serial changes in highly sensitive troponin i assay and early diagnosis of myocardial infarction
    • T. Keller, T. Zeller, F. Ojeda, S. Tzikas, L. Lillpopp, C. Sinning, et al., Serial changes in highly sensitive troponin I assay and early diagnosis of myocardial infarction, JAMA 306 (2011) 2684-2693.
    • (2011) JAMA , vol.306 , pp. 2684-2693
    • Keller, T.1    Zeller, T.2    Ojeda, F.3    Tzikas, S.4    Lillpopp, L.5    Sinning, C.6
  • 39
    • 84856070725 scopus 로고    scopus 로고
    • Absolute and relative kinetic changes of high-sensitivity cardiac troponin T in acute coronary syndrome and in patients with increased troponin in the absence of acute coronary syndrome
    • M. Mueller, M. Biener, M. Vafaie, S. Doerr, T. Keller, S. Blankenberg, et al., Absolute and relative kinetic changes of high-sensitivity cardiac troponin T in acute coronary syndrome and in patients with increased troponin in the absence of acute coronary syndrome, Clin. Chem. 58 (2012) 209-218.
    • (2012) Clin. Chem. , vol.58 , pp. 209-218
    • Mueller, M.1    Biener, M.2    Vafaie, M.3    Doerr, S.4    Keller, T.5    Blankenberg, S.6
  • 41
    • 84856158305 scopus 로고    scopus 로고
    • ESC Guidelines for the management of acute coronary syndromes in patients presenting without persistent ST-segment elevation: The Task Force for the management of acute coronary syndromes (ACS) in patients presenting without persistent ST-segment elevation of the European Society of Cardiology (ESC)
    • C.W. Hamm, J.-P. Bassand, S. Agewall, J. Bax, E. Boersma, H. Bueno, et al., ESC Guidelines for the management of acute coronary syndromes in patients presenting without persistent ST-segment elevation: The Task Force for the management of acute coronary syndromes (ACS) in patients presenting without persistent ST-segment elevation of the European Society of Cardiology (ESC), Eur. Heart J. 32 (2011) 2999-3054.
    • (2011) Eur. Heart J. , vol.32 , pp. 2999-3054
    • Hamm, C.W.1    Bassand, J.-P.2    Agewall, S.3    Bax, J.4    Boersma, E.5    Bueno, H.6
  • 42
    • 84857868710 scopus 로고    scopus 로고
    • Troponin T percentiles from a random population sample, emergency room patients and patients with myocardial infarction
    • O. Hammarsten, M.L.X. Fu, R. Sigurjonsdottir, M. Petzold, L. Said, K. Landin-Wilhelmsen, et al., Troponin T percentiles from a random population sample, emergency room patients and patients with myocardial infarction, Clin. Chem. 58 (2012) 628-637.
    • (2012) Clin. Chem. , vol.58 , pp. 628-637
    • Hammarsten, O.1    Fu, M.L.X.2    Sigurjonsdottir, R.3    Petzold, M.4    Said, L.5    Landin-Wilhelmsen, K.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.