메뉴 건너뛰기




Volumn 36, Issue 11, 2017, Pages 1164-1173

Bleeding and thrombosis associated with ventricular assist device therapy

Author keywords

anti thrombotic therapy; gastrointestinal bleeding; hemolysis; left ventricular assisted device; thrombosis

Indexed keywords

BIOLOGICAL MARKER; DABIGATRAN; DALTEPARIN; ENOXAPARIN; VON WILLEBRAND FACTOR;

EID: 85020066763     PISSN: 10532498     EISSN: 15573117     Source Type: Journal    
DOI: 10.1016/j.healun.2017.05.008     Document Type: Article
Times cited : (86)

References (70)
  • 1
    • 84949753718 scopus 로고    scopus 로고
    • Seventh INTERMACS annual report: 15,000 patients and counting
    • Kirklin, J.K., Naftel, D.C., Pagani, F.D., et al. Seventh INTERMACS annual report: 15,000 patients and counting. J Heart Lung Transplant 34 (2015), 1495–1504.
    • (2015) J Heart Lung Transplant , vol.34 , pp. 1495-1504
    • Kirklin, J.K.1    Naftel, D.C.2    Pagani, F.D.3
  • 2
    • 34548311569 scopus 로고    scopus 로고
    • Use of a continuous-flow device in patients awaiting heart transplantation
    • Miller, L.W., Pagani, F.D., Russell, S.D., et al. Use of a continuous-flow device in patients awaiting heart transplantation. N Engl J Med 357 (2007), 885–896.
    • (2007) N Engl J Med , vol.357 , pp. 885-896
    • Miller, L.W.1    Pagani, F.D.2    Russell, S.D.3
  • 3
    • 84863195802 scopus 로고    scopus 로고
    • Use of an intrapericardial, continuous-flow, centrifugal pump in patients awaiting heart transplantation
    • Aaronson, K.D., Slaughter, M.S., Miller, L.W., et al. Use of an intrapericardial, continuous-flow, centrifugal pump in patients awaiting heart transplantation. Circulation 125 (2012), 3191–3200.
    • (2012) Circulation , vol.125 , pp. 3191-3200
    • Aaronson, K.D.1    Slaughter, M.S.2    Miller, L.W.3
  • 4
    • 84892178504 scopus 로고    scopus 로고
    • Diagnosis of hemolysis and device thrombosis with lactate dehydrogenase during left ventricular assist device support
    • Shah, P., Mehta, V.M., Cowger, J.A., et al. Diagnosis of hemolysis and device thrombosis with lactate dehydrogenase during left ventricular assist device support. J Heart Lung Transplant 33 (2014), 102–104.
    • (2014) J Heart Lung Transplant , vol.33 , pp. 102-104
    • Shah, P.1    Mehta, V.M.2    Cowger, J.A.3
  • 5
    • 77951264913 scopus 로고    scopus 로고
    • Increased incidence of gastrointestinal bleeding following implantation of the HeartMate II LVAD
    • Stern, D.R., Kazam, J., Edwards, P., et al. Increased incidence of gastrointestinal bleeding following implantation of the HeartMate II LVAD. J Card Surg 25 (2010), 352–356.
    • (2010) J Card Surg , vol.25 , pp. 352-356
    • Stern, D.R.1    Kazam, J.2    Edwards, P.3
  • 6
    • 84892151754 scopus 로고    scopus 로고
    • Gastrointestinal bleeding and subsequent risk of thromboembolic events during support with a left ventricular assist device
    • Stulak, J.M., Lee, D., Haft, J.W., et al. Gastrointestinal bleeding and subsequent risk of thromboembolic events during support with a left ventricular assist device. J Heart Lung Transplant 33 (2014), 60–64.
    • (2014) J Heart Lung Transplant , vol.33 , pp. 60-64
    • Stulak, J.M.1    Lee, D.2    Haft, J.W.3
  • 7
    • 85011931414 scopus 로고    scopus 로고
    • intrapericardial left ventricular assist device for advanced heart failure
    • Rogers, J.G., Pagani, F.D., Tatooles, A.J., et al. intrapericardial left ventricular assist device for advanced heart failure. N Engl J Med 376 (2017), 451–460.
    • (2017) N Engl J Med , vol.376 , pp. 451-460
    • Rogers, J.G.1    Pagani, F.D.2    Tatooles, A.J.3
  • 8
    • 84872848201 scopus 로고    scopus 로고
    • The 2013 International Society for Heart and Lung Transplantation Guidelines for mechanical circulatory support: executive summary
    • Feldman, D., Pamboukian, S.V., Teuteberg, J.J., et al. The 2013 International Society for Heart and Lung Transplantation Guidelines for mechanical circulatory support: executive summary. J Heart Lung Transplant 32 (2013), 157–187.
    • (2013) J Heart Lung Transplant , vol.32 , pp. 157-187
    • Feldman, D.1    Pamboukian, S.V.2    Teuteberg, J.J.3
  • 9
    • 34247558233 scopus 로고    scopus 로고
    • The effect of surface roughness on activation of the coagulation system and platelet adhesion in rotary blood pumps
    • Linneweber, J., Dohmen, P.M., Kertzscher, U., et al. The effect of surface roughness on activation of the coagulation system and platelet adhesion in rotary blood pumps. Artif Organs 31 (2007), 345–351.
    • (2007) Artif Organs , vol.31 , pp. 345-351
    • Linneweber, J.1    Dohmen, P.M.2    Kertzscher, U.3
  • 10
    • 84864848430 scopus 로고    scopus 로고
    • A quantitative comparison of mechanical blood damage parameters in rotary ventricular assist devices: shear stress, exposure time and hemolysis index
    • Fraser, K.H., Zhang, T., Taskin, M.E., et al. A quantitative comparison of mechanical blood damage parameters in rotary ventricular assist devices: shear stress, exposure time and hemolysis index. J Biomech Eng, 134, 2012, 081002.
    • (2012) J Biomech Eng , vol.134 , pp. 081002
    • Fraser, K.H.1    Zhang, T.2    Taskin, M.E.3
  • 11
    • 84927968993 scopus 로고    scopus 로고
    • Histologic analysis of clots in explanted axial continuous-flow left ventricular assist devices
    • Prasad, S.M., Robertson, J.O., Itoh, A., et al. Histologic analysis of clots in explanted axial continuous-flow left ventricular assist devices. J Heart Lung Transplant 34 (2015), 616–618.
    • (2015) J Heart Lung Transplant , vol.34 , pp. 616-618
    • Prasad, S.M.1    Robertson, J.O.2    Itoh, A.3
  • 12
    • 63449130751 scopus 로고    scopus 로고
    • Surface coatings for ventricular assist devices
    • Sin, D.C., Kei, H.L., Miao, X., Surface coatings for ventricular assist devices. Exp Rev Med Dev 6 (2009), 51–60.
    • (2009) Exp Rev Med Dev , vol.6 , pp. 51-60
    • Sin, D.C.1    Kei, H.L.2    Miao, X.3
  • 13
    • 9144226905 scopus 로고    scopus 로고
    • Fibrinogen adsorption and platelet adhesion to metal and carbon coatings
    • Mikhalovska, L.I., Santin, M., Denyer, S.P., et al. Fibrinogen adsorption and platelet adhesion to metal and carbon coatings. Thromb Haemost 92 (2004), 1032–1039.
    • (2004) Thromb Haemost , vol.92 , pp. 1032-1039
    • Mikhalovska, L.I.1    Santin, M.2    Denyer, S.P.3
  • 14
    • 0037024107 scopus 로고    scopus 로고
    • Platelet adhesion to polystyrene-based surfaces preadsorbed with plasmas selectively depleted in fibrinogen, fibronectin, vitronectin, or von Willebrand׳s factor
    • Tsai, W.B., Grunkemeier, J.M., McFarland, C.D., et al. Platelet adhesion to polystyrene-based surfaces preadsorbed with plasmas selectively depleted in fibrinogen, fibronectin, vitronectin, or von Willebrand׳s factor. J Biomed Mater Res 60 (2002), 348–359.
    • (2002) J Biomed Mater Res , vol.60 , pp. 348-359
    • Tsai, W.B.1    Grunkemeier, J.M.2    McFarland, C.D.3
  • 15
    • 0030762784 scopus 로고    scopus 로고
    • Platelet damage caused by the centrifugal pump: in vitro evaluation by measuring the release of alpha-granule packing proteins
    • Kawahito, K., Mohara, J., Misawa, Y., et al. Platelet damage caused by the centrifugal pump: in vitro evaluation by measuring the release of alpha-granule packing proteins. Artif Organs 21 (1997), 1105–1109.
    • (1997) Artif Organs , vol.21 , pp. 1105-1109
    • Kawahito, K.1    Mohara, J.2    Misawa, Y.3
  • 16
    • 0016704314 scopus 로고
    • Functional changes in platelets during extracorporeal circulation
    • Tamari, Y., Aledort, L., Puszkin, E., et al. Functional changes in platelets during extracorporeal circulation. Ann Thorac Surg 19 (1975), 639–647.
    • (1975) Ann Thorac Surg , vol.19 , pp. 639-647
    • Tamari, Y.1    Aledort, L.2    Puszkin, E.3
  • 17
    • 77957329355 scopus 로고    scopus 로고
    • Enhanced microparticles in ventricular assist device patients predict platelet, leukocyte and endothelial cell activation
    • Diehl, P., Aleker, M., Helbing, T., et al. Enhanced microparticles in ventricular assist device patients predict platelet, leukocyte and endothelial cell activation. Interact Cardiovasc Thorac Surg 11 (2010), 133–137.
    • (2010) Interact Cardiovasc Thorac Surg , vol.11 , pp. 133-137
    • Diehl, P.1    Aleker, M.2    Helbing, T.3
  • 18
    • 84898808086 scopus 로고    scopus 로고
    • Association between cell-derived microparticles and adverse events in patients with nonpulsatile left ventricular assist devices
    • Nascimbene, A., Hernandez, R., George, J.K., et al. Association between cell-derived microparticles and adverse events in patients with nonpulsatile left ventricular assist devices. J Heart Lung Transplant 33 (2014), 470–477.
    • (2014) J Heart Lung Transplant , vol.33 , pp. 470-477
    • Nascimbene, A.1    Hernandez, R.2    George, J.K.3
  • 19
    • 77952583879 scopus 로고    scopus 로고
    • Post-operative heparin may not be required for transitioning patients with a HeartMate II left ventricular assist system to long-term warfarin therapy
    • Slaughter, M.S., Naka, Y., John, R., et al. Post-operative heparin may not be required for transitioning patients with a HeartMate II left ventricular assist system to long-term warfarin therapy. J Heart Lung Transplant 29 (2010), 616–624.
    • (2010) J Heart Lung Transplant , vol.29 , pp. 616-624
    • Slaughter, M.S.1    Naka, Y.2    John, R.3
  • 20
    • 84949851555 scopus 로고    scopus 로고
    • Fully magnetically levitated left ventricular assist system for treating advanced HF: a multicenter study
    • Netuka, I., Sood, P., Pya, Y., et al. Fully magnetically levitated left ventricular assist system for treating advanced HF: a multicenter study. J Am Coll Cardiol 66 (2015), 2579–2589.
    • (2015) J Am Coll Cardiol , vol.66 , pp. 2579-2589
    • Netuka, I.1    Sood, P.2    Pya, Y.3
  • 21
    • 40649123746 scopus 로고    scopus 로고
    • Non-surgical bleeding in patients with ventricular assist devices could be explained by acquired von Willebrand disease
    • Geisen, U., Heilmann, C., Beyersdorf, F., et al. Non-surgical bleeding in patients with ventricular assist devices could be explained by acquired von Willebrand disease. Eur J Cardiothorac Surg 33 (2008), 679–684.
    • (2008) Eur J Cardiothorac Surg , vol.33 , pp. 679-684
    • Geisen, U.1    Heilmann, C.2    Beyersdorf, F.3
  • 22
    • 84897485515 scopus 로고    scopus 로고
    • Acquired von Willebrand syndrome in patients with a centrifugal or axial continuous flow left ventricular assist device
    • Meyer, A.L., Malehsa, D., Budde, U., et al. Acquired von Willebrand syndrome in patients with a centrifugal or axial continuous flow left ventricular assist device. JACC Heart Fail 2 (2014), 141–145.
    • (2014) JACC Heart Fail , vol.2 , pp. 141-145
    • Meyer, A.L.1    Malehsa, D.2    Budde, U.3
  • 23
    • 0029858896 scopus 로고    scopus 로고
    • Shear-dependent changes in the three-dimensional structure of human von Willebrand factor
    • Siedlecki, C.A., Lestini, B.J., Kottke-Marchant, K.K., et al. Shear-dependent changes in the three-dimensional structure of human von Willebrand factor. Blood 88 (1996), 2939–2950.
    • (1996) Blood , vol.88 , pp. 2939-2950
    • Siedlecki, C.A.1    Lestini, B.J.2    Kottke-Marchant, K.K.3
  • 24
    • 84874852831 scopus 로고    scopus 로고
    • Mechanistic pathway(s) of acquired von Willebrand syndrome with a continuous-flow ventricular assist device: in vitro findings
    • Dassanayaka, S., Slaughter, M.S., Bartoli, C.R., Mechanistic pathway(s) of acquired von Willebrand syndrome with a continuous-flow ventricular assist device: in vitro findings. ASAIO J 59 (2013), 123–129.
    • (2013) ASAIO J , vol.59 , pp. 123-129
    • Dassanayaka, S.1    Slaughter, M.S.2    Bartoli, C.R.3
  • 25
    • 77953400352 scopus 로고    scopus 로고
    • The biological basis of thrombosis and bleeding in patients with ventricular assist devices
    • John, R., Lee, S., The biological basis of thrombosis and bleeding in patients with ventricular assist devices. J Cardiovasc Transl Res 2 (2009), 63–70.
    • (2009) J Cardiovasc Transl Res , vol.2 , pp. 63-70
    • John, R.1    Lee, S.2
  • 26
    • 0027394454 scopus 로고
    • Real-time analysis of shear-dependent thrombus formation and its blockade by inhibitors of von Willebrand factor binding to platelets
    • Alevriadou, B.R., Moake, J.L., Turner, N.A., et al. Real-time analysis of shear-dependent thrombus formation and its blockade by inhibitors of von Willebrand factor binding to platelets. Blood 81 (1993), 1263–1276.
    • (1993) Blood , vol.81 , pp. 1263-1276
    • Alevriadou, B.R.1    Moake, J.L.2    Turner, N.A.3
  • 27
    • 66149135264 scopus 로고    scopus 로고
    • Severely impaired von Willebrand factor-dependent platelet aggregation in patients with a continuous-flow left ventricular assist device (HeartMate II)
    • Klovaite, J., Gustafsson, F., Mortensen, S.A., et al. Severely impaired von Willebrand factor-dependent platelet aggregation in patients with a continuous-flow left ventricular assist device (HeartMate II). J Am Coll Cardiol 53 (2009), 2162–2167.
    • (2009) J Am Coll Cardiol , vol.53 , pp. 2162-2167
    • Klovaite, J.1    Gustafsson, F.2    Mortensen, S.A.3
  • 28
    • 78650155308 scopus 로고    scopus 로고
    • Acquired von Willebrand syndrome in patients with an axial flow left ventricular assist device
    • Meyer, A.L., Malehsa, D., Bara, C., et al. Acquired von Willebrand syndrome in patients with an axial flow left ventricular assist device. Circ Heart Fail 3 (2010), 675–681.
    • (2010) Circ Heart Fail , vol.3 , pp. 675-681
    • Meyer, A.L.1    Malehsa, D.2    Bara, C.3
  • 29
    • 84952639662 scopus 로고    scopus 로고
    • Acquired von Willebrand factor deficiency caused by LVAD is ADAMTS-13 and platelet dependent
    • Jilma-Stohlawetz, P., Quehenberger, P., Schima, H., et al. Acquired von Willebrand factor deficiency caused by LVAD is ADAMTS-13 and platelet dependent. Thromb Res 137 (2016), 196–201.
    • (2016) Thromb Res , vol.137 , pp. 196-201
    • Jilma-Stohlawetz, P.1    Quehenberger, P.2    Schima, H.3
  • 30
    • 79960015603 scopus 로고    scopus 로고
    • Arteriovenous malformation and gastrointestinal bleeding in patients with the HeartMate II left ventricular assist device
    • Demirozu, Z.T., Radovancevic, R., Hochman, L.F., et al. Arteriovenous malformation and gastrointestinal bleeding in patients with the HeartMate II left ventricular assist device. J Heart Lung Transplant 30 (2011), 849–853.
    • (2011) J Heart Lung Transplant , vol.30 , pp. 849-853
    • Demirozu, Z.T.1    Radovancevic, R.2    Hochman, L.F.3
  • 31
    • 84871926950 scopus 로고    scopus 로고
    • Readmissions after implantation of axial flow left ventricular assist device
    • Hasin, T., Marmor, Y., Kremers, W., et al. Readmissions after implantation of axial flow left ventricular assist device. J Am Coll Cardiol 61 (2013), 153–163.
    • (2013) J Am Coll Cardiol , vol.61 , pp. 153-163
    • Hasin, T.1    Marmor, Y.2    Kremers, W.3
  • 32
    • 11844262604 scopus 로고    scopus 로고
    • Gastrointestinal bleeding from arteriovenous malformations in patients supported by the Jarvik 2000 axial-flow left ventricular assist device
    • Letsou, G.V., Shah, N., Gregoric, I.D., et al. Gastrointestinal bleeding from arteriovenous malformations in patients supported by the Jarvik 2000 axial-flow left ventricular assist device. J Heart Lung Transplant 24 (2005), 105–109.
    • (2005) J Heart Lung Transplant , vol.24 , pp. 105-109
    • Letsou, G.V.1    Shah, N.2    Gregoric, I.D.3
  • 33
    • 84855585557 scopus 로고    scopus 로고
    • Mechanisms of bleeding and approach to patients with axial-flow left ventricular assist devices
    • Suarez, J., Patel, C.B., Felker, G.M., et al. Mechanisms of bleeding and approach to patients with axial-flow left ventricular assist devices. Circ Heart Fail 4 (2011), 779–784.
    • (2011) Circ Heart Fail , vol.4 , pp. 779-784
    • Suarez, J.1    Patel, C.B.2    Felker, G.M.3
  • 34
    • 78650086786 scopus 로고    scopus 로고
    • Unforeseen consequences of therapy with continuous-flow pumps
    • Frazier, O.H., Unforeseen consequences of therapy with continuous-flow pumps. Circ Heart Fail 3 (2010), 647–649.
    • (2010) Circ Heart Fail , vol.3 , pp. 647-649
    • Frazier, O.H.1
  • 35
    • 84879239446 scopus 로고    scopus 로고
    • Pulsatility and the risk of nonsurgical bleeding in patients supported with the continuous-flow left ventricular assist device HeartMate II
    • Wever-Pinzon, O., Selzman, C.H., Drakos, S.G., et al. Pulsatility and the risk of nonsurgical bleeding in patients supported with the continuous-flow left ventricular assist device HeartMate II. Circ Heart Fail 6 (2013), 517–526.
    • (2013) Circ Heart Fail , vol.6 , pp. 517-526
    • Wever-Pinzon, O.1    Selzman, C.H.2    Drakos, S.G.3
  • 36
    • 84960540625 scopus 로고    scopus 로고
    • Longitudinal changes in hemostatic parameters and reduced pulsatility contribute to non-surgical bleeding in patients with centrifugal continuous-flow left ventricular assist devices
    • Muthiah, K., Connor, D., Ly, K., et al. Longitudinal changes in hemostatic parameters and reduced pulsatility contribute to non-surgical bleeding in patients with centrifugal continuous-flow left ventricular assist devices. J Heart Lung Transplant 35 (2016), 743–751.
    • (2016) J Heart Lung Transplant , vol.35 , pp. 743-751
    • Muthiah, K.1    Connor, D.2    Ly, K.3
  • 37
    • 85007012266 scopus 로고    scopus 로고
    • PREVENtion of HeartMate II Pump Thrombosis Through Clinical Management: the PREVENT multi-center study
    • Maltais, S., Kilic, A., Nathan, S., et al. PREVENtion of HeartMate II Pump Thrombosis Through Clinical Management: the PREVENT multi-center study. J Heart Lung Transplant 36 (2017), 1–12.
    • (2017) J Heart Lung Transplant , vol.36 , pp. 1-12
    • Maltais, S.1    Kilic, A.2    Nathan, S.3
  • 38
    • 84920038382 scopus 로고    scopus 로고
    • Thalidomide for treatment of gastrointestinal angiodysplasia in patients with left ventricular assist devices: case series and treatment protocol
    • Draper, K., Kale, P., Martin, B., et al. Thalidomide for treatment of gastrointestinal angiodysplasia in patients with left ventricular assist devices: case series and treatment protocol. J Heart Lung Transplant 34 (2015), 132–134.
    • (2015) J Heart Lung Transplant , vol.34 , pp. 132-134
    • Draper, K.1    Kale, P.2    Martin, B.3
  • 39
    • 84860254527 scopus 로고    scopus 로고
    • Incidence and management of gastrointestinal bleeding with continuous flow assist devices
    • Aggarwal, A., Pant, R., Kumar, S., et al. Incidence and management of gastrointestinal bleeding with continuous flow assist devices. Ann Thorac Surg 93 (2012), 1534–1540.
    • (2012) Ann Thorac Surg , vol.93 , pp. 1534-1540
    • Aggarwal, A.1    Pant, R.2    Kumar, S.3
  • 40
    • 84978161622 scopus 로고    scopus 로고
    • Elevated angiopoietin-2 level in patients with continuous-flow left ventricular assist devices leads to altered angiogenesis and is associated with higher nonsurgical bleeding
    • Tabit, C.E., Chen, P., Kim, G.H., et al. Elevated angiopoietin-2 level in patients with continuous-flow left ventricular assist devices leads to altered angiogenesis and is associated with higher nonsurgical bleeding. Circulation 134 (2016), 141–152.
    • (2016) Circulation , vol.134 , pp. 141-152
    • Tabit, C.E.1    Chen, P.2    Kim, G.H.3
  • 41
    • 83455185433 scopus 로고    scopus 로고
    • Reactive oxygen species and endothelial function—role of nitric oxide synthase uncoupling and Nox family nicotinamide adenine dinucleotide phosphate oxidases
    • Montezano, A.C., Touyz, R.M., Reactive oxygen species and endothelial function—role of nitric oxide synthase uncoupling and Nox family nicotinamide adenine dinucleotide phosphate oxidases. Basic Clin Pharmacol Toxicol 110 (2012), 87–94.
    • (2012) Basic Clin Pharmacol Toxicol , vol.110 , pp. 87-94
    • Montezano, A.C.1    Touyz, R.M.2
  • 42
    • 84937547986 scopus 로고    scopus 로고
    • Left ventricular assist device-associated carbon monoxide and iron-enhanced hypercoagulation: impact of concurrent disease
    • Nielsen, V.G., Sobieski, M.A. 2nd, Slaughter, M.S., Left ventricular assist device-associated carbon monoxide and iron-enhanced hypercoagulation: impact of concurrent disease. ASAIO J 61 (2015), 417–423.
    • (2015) ASAIO J , vol.61 , pp. 417-423
    • Nielsen, V.G.1    Sobieski, M.A.2    Slaughter, M.S.3
  • 43
    • 84927691106 scopus 로고    scopus 로고
    • Iron and carbon monoxide enhance coagulation and attenuate fibrinolysis by different mechanisms
    • Nielsen, V.G., Pretorius, E., Iron and carbon monoxide enhance coagulation and attenuate fibrinolysis by different mechanisms. Blood Coagul Fibrinolysis 25 (2014), 695–702.
    • (2014) Blood Coagul Fibrinolysis , vol.25 , pp. 695-702
    • Nielsen, V.G.1    Pretorius, E.2
  • 44
    • 84855191428 scopus 로고    scopus 로고
    • Carbon monoxide and nitric oxide modulate alpha(2)-antiplasmin and plasmin activity: role of heme
    • Arkebauer, M.R., Kanaparthy, S.S., Malayaman, S.N., et al. Carbon monoxide and nitric oxide modulate alpha(2)-antiplasmin and plasmin activity: role of heme. Blood Coagul Fibrinolysis 22 (2011), 712–719.
    • (2011) Blood Coagul Fibrinolysis , vol.22 , pp. 712-719
    • Arkebauer, M.R.1    Kanaparthy, S.S.2    Malayaman, S.N.3
  • 45
    • 85031851673 scopus 로고    scopus 로고
    • Accessed February 8.
    • Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS). http://www.intermacs.org/. Accessed February 8, 2013.
    • (2013)
  • 46
    • 84892185289 scopus 로고    scopus 로고
    • Hemolysis: a harbinger of adverse outcome after left ventricular assist device implant
    • Cowger, J.A., Romano, M.A., Shah, P., et al. Hemolysis: a harbinger of adverse outcome after left ventricular assist device implant. J Heart Lung Transplant 33 (2014), 35–43.
    • (2014) J Heart Lung Transplant , vol.33 , pp. 35-43
    • Cowger, J.A.1    Romano, M.A.2    Shah, P.3
  • 47
    • 84892148459 scopus 로고    scopus 로고
    • Unexpected abrupt increase in left ventricular assist device thrombosis
    • Starling, R.C., Moazami, N., Silvestry, S.C., et al. Unexpected abrupt increase in left ventricular assist device thrombosis. N Engl J Med 370 (2014), 33–40.
    • (2014) N Engl J Med , vol.370 , pp. 33-40
    • Starling, R.C.1    Moazami, N.2    Silvestry, S.C.3
  • 48
    • 84892177900 scopus 로고    scopus 로고
    • Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) analysis of pump thrombosis in the HeartMate II left ventricular assist device
    • Kirklin, J.K., Naftel, D.C., Kormos, R.L., et al. Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) analysis of pump thrombosis in the HeartMate II left ventricular assist device. J Heart Lung Transplant 33 (2014), 12–22.
    • (2014) J Heart Lung Transplant , vol.33 , pp. 12-22
    • Kirklin, J.K.1    Naftel, D.C.2    Kormos, R.L.3
  • 49
    • 85009224966 scopus 로고    scopus 로고
    • Left ventricular assist device outcomes based on flow configuration and pre-operative left ventricular dimension: an Interagency Registry for Mechanically Assisted Circulatory Support analysis.
    • Shah, P, Birk, S., Maltais, S., et al. Left ventricular assist device outcomes based on flow configuration and pre-operative left ventricular dimension: an Interagency Registry for Mechanically Assisted Circulatory Support analysis. J Heart Lung Transplant 36 (2017), 640–649.
    • (2017) J Heart Lung Transplant , vol.36 , pp. 640-649
    • Shah, P.1    Birk, S.2    Maltais, S.3
  • 50
    • 84892141967 scopus 로고    scopus 로고
    • An analysis of pump thrombus events in patients in the HeartWare ADVANCE bridge to transplant and continued access protocol trial
    • Najjar, S.S., Slaughter, M.S., Pagani, F.D., et al. An analysis of pump thrombus events in patients in the HeartWare ADVANCE bridge to transplant and continued access protocol trial. J Heart Lung Transplant 33 (2014), 23–34.
    • (2014) J Heart Lung Transplant , vol.33 , pp. 23-34
    • Najjar, S.S.1    Slaughter, M.S.2    Pagani, F.D.3
  • 51
    • 84958587026 scopus 로고    scopus 로고
    • Adverse events in contemporary continuous-flow left ventricular assist devices: a multi-institutional comparison shows significant differences
    • Stulak, J.M., Davis, M.E., Haglund, N., et al. Adverse events in contemporary continuous-flow left ventricular assist devices: a multi-institutional comparison shows significant differences. J Thorac Cardiovasc Surg 151 (2016), 177–189.
    • (2016) J Thorac Cardiovasc Surg , vol.151 , pp. 177-189
    • Stulak, J.M.1    Davis, M.E.2    Haglund, N.3
  • 52
    • 84949762286 scopus 로고    scopus 로고
    • Pump thrombosis in the Thoratec HeartMate II device: an update analysis of the INTERMACS Registry
    • Kirklin, J.K., Naftel, D.C., Pagani, F.D., et al. Pump thrombosis in the Thoratec HeartMate II device: an update analysis of the INTERMACS Registry. J Heart Lung Transplant 34 (2015), 1515–1526.
    • (2015) J Heart Lung Transplant , vol.34 , pp. 1515-1526
    • Kirklin, J.K.1    Naftel, D.C.2    Pagani, F.D.3
  • 53
    • 84949817077 scopus 로고    scopus 로고
    • Treatment of device thrombus in the HeartWare HVAD: Success and outcomes depend significantly on the initial treatment strategy
    • Stulak, J.M., Dunlay, S.M., Sharma, S., et al. Treatment of device thrombus in the HeartWare HVAD: Success and outcomes depend significantly on the initial treatment strategy. J Heart Lung Transplant 34 (2015), 1535–1541.
    • (2015) J Heart Lung Transplant , vol.34 , pp. 1535-1541
    • Stulak, J.M.1    Dunlay, S.M.2    Sharma, S.3
  • 54
    • 84978264031 scopus 로고    scopus 로고
    • Diagnosis and treatment algorithm for blood flow obstructions in patients with left ventricular assist device
    • Scandroglio, A.M., Kaufmann, F., Pieri, M., et al. Diagnosis and treatment algorithm for blood flow obstructions in patients with left ventricular assist device. J Am Coll Cardiol 67 (2016), 2758–2768.
    • (2016) J Am Coll Cardiol , vol.67 , pp. 2758-2768
    • Scandroglio, A.M.1    Kaufmann, F.2    Pieri, M.3
  • 55
    • 68949202239 scopus 로고    scopus 로고
    • Low thromboembolism and pump thrombosis with the HeartMate II left ventricular assist device: analysis of outpatient anti-coagulation
    • Boyle, A.J., Russell, S.D., Teuteberg, J.J., et al. Low thromboembolism and pump thrombosis with the HeartMate II left ventricular assist device: analysis of outpatient anti-coagulation. J Heart Lung Transplant 28 (2009), 881–887.
    • (2009) J Heart Lung Transplant , vol.28 , pp. 881-887
    • Boyle, A.J.1    Russell, S.D.2    Teuteberg, J.J.3
  • 56
    • 84955261488 scopus 로고    scopus 로고
    • Antiplatelet therapy and adverse hematologic events during Heart Mate II support
    • Saeed, O., Shah, A., Kargoli, F., et al. Antiplatelet therapy and adverse hematologic events during Heart Mate II support. Circ Heart Fail, 9, 2016, e002296.
    • (2016) Circ Heart Fail , vol.9 , pp. e002296
    • Saeed, O.1    Shah, A.2    Kargoli, F.3
  • 57
    • 85031855789 scopus 로고    scopus 로고
    • Minimal adverse events in HeartMate II patients with no antiplatelet therapy: preliminary results from the european TRACE study
    • Netuka, I., Litzler, P.Y., Berchtold-Herz, M., et al. Minimal adverse events in HeartMate II patients with no antiplatelet therapy: preliminary results from the european TRACE study. J Heart Lung Transplant, 33(suppl), 2014, S11.
    • (2014) J Heart Lung Transplant , vol.33 , pp. S11
    • Netuka, I.1    Litzler, P.Y.2    Berchtold-Herz, M.3
  • 58
    • 85031848141 scopus 로고    scopus 로고
    • https://clinicaltrials.gov/ct2/show/NCT02836652?term=NCT02836652&rank=1/, Prevention of non-surgical bleeding by management of HeartMate II patients without antiplatelet therapy (PREVENT II). Accessed May 3.
    • Clinicaltrials.gov. Prevention of non-surgical bleeding by management of HeartMate II patients without antiplatelet therapy (PREVENT II). https://clinicaltrials.gov/ct2/show/NCT02836652?term=NCT02836652&rank=1/. Accessed May 3, 2017.
    • (2017)
  • 59
    • 34249011417 scopus 로고    scopus 로고
    • Design features, developmental status, and experimental results with the HeartMate III centrifugal left ventricular assist system with a magnetically levitated rotor
    • Farrar, D.J., Bourque, K., Dague, C.P., et al. Design features, developmental status, and experimental results with the HeartMate III centrifugal left ventricular assist system with a magnetically levitated rotor. ASAIO J 53 (2007), 310–315.
    • (2007) ASAIO J , vol.53 , pp. 310-315
    • Farrar, D.J.1    Bourque, K.2    Dague, C.P.3
  • 60
    • 85011890991 scopus 로고    scopus 로고
    • A fully magnetically levitated circulatory pump for advanced heart failure
    • Mehra, M.R., Naka, Y., Uriel, N., et al. A fully magnetically levitated circulatory pump for advanced heart failure. N Engl J Med 376 (2017), 440–450.
    • (2017) N Engl J Med , vol.376 , pp. 440-450
    • Mehra, M.R.1    Naka, Y.2    Uriel, N.3
  • 61
    • 84990922492 scopus 로고    scopus 로고
    • Evaluation of von Willebrand factor with a fully magnetically levitated centrifugal continuous-flow left ventricular assist device in advanced heart failure
    • Netuka, I., Kvasnicka, T., Kvasnicka, J., et al. Evaluation of von Willebrand factor with a fully magnetically levitated centrifugal continuous-flow left ventricular assist device in advanced heart failure. J Heart Lung Transplant 35 (2016), 860–867.
    • (2016) J Heart Lung Transplant , vol.35 , pp. 860-867
    • Netuka, I.1    Kvasnicka, T.2    Kvasnicka, J.3
  • 62
    • 84961140672 scopus 로고    scopus 로고
    • Anticoagulation with apixaban in a patient with a left ventricular assist device and gastrointestinal bleeding: a viable alternative to warfarin?
    • Pollari, F., Fischlein, T., Fittkau, M., et al. Anticoagulation with apixaban in a patient with a left ventricular assist device and gastrointestinal bleeding: a viable alternative to warfarin?. J Thorac Cardiovasc Surg 151 (2016), e79–e81.
    • (2016) J Thorac Cardiovasc Surg , vol.151 , pp. e79-e81
    • Pollari, F.1    Fischlein, T.2    Fittkau, M.3
  • 63
    • 84884512133 scopus 로고    scopus 로고
    • Dabigatran versus warfarin in patients with mechanical heart valves
    • Eikelboom, J.W., Connolly, S.J., Brueckmann, M., et al. Dabigatran versus warfarin in patients with mechanical heart valves. N Engl J Med 369 (2013), 1206–1214.
    • (2013) N Engl J Med , vol.369 , pp. 1206-1214
    • Eikelboom, J.W.1    Connolly, S.J.2    Brueckmann, M.3
  • 64
    • 84897573638 scopus 로고    scopus 로고
    • Primary anticoagulation with bivalirudin for patients with implantable ventricular assist devices
    • Pieri, M., Agracheva, N., Di Prima, A.L., et al. Primary anticoagulation with bivalirudin for patients with implantable ventricular assist devices. Artif Organs 38 (2014), 342–346.
    • (2014) Artif Organs , vol.38 , pp. 342-346
    • Pieri, M.1    Agracheva, N.2    Di Prima, A.L.3
  • 65
    • 84857572411 scopus 로고    scopus 로고
    • Argatroban anticoagulation for heparin induced thrombocytopenia in patients with ventricular assist devices
    • Pappalardo, F., Scandroglio, A.M., Potapov, E., et al. Argatroban anticoagulation for heparin induced thrombocytopenia in patients with ventricular assist devices. Minerva Anestesiol 78 (2012), 330–335.
    • (2012) Minerva Anestesiol , vol.78 , pp. 330-335
    • Pappalardo, F.1    Scandroglio, A.M.2    Potapov, E.3
  • 66
    • 84908017020 scopus 로고    scopus 로고
    • Prior hematologic conditions carry a high morbidity and mortality in patients supported with continuous-flow left ventricular assist devices
    • Fried, J., Levin, A.P., Mody, K.M., et al. Prior hematologic conditions carry a high morbidity and mortality in patients supported with continuous-flow left ventricular assist devices. J Heart Lung Transplant 33 (2014), 1119–1125.
    • (2014) J Heart Lung Transplant , vol.33 , pp. 1119-1125
    • Fried, J.1    Levin, A.P.2    Mody, K.M.3
  • 67
    • 84890025521 scopus 로고    scopus 로고
    • Consensus and update on the definition of on-treatment platelet reactivity to adenosine diphosphate associated with ischemia and bleeding
    • Tantry, U.S., Bonello, L., Aradi, D., et al. Consensus and update on the definition of on-treatment platelet reactivity to adenosine diphosphate associated with ischemia and bleeding. J Am Coll Cardiol 62 (2013), 2261–2273.
    • (2013) J Am Coll Cardiol , vol.62 , pp. 2261-2273
    • Tantry, U.S.1    Bonello, L.2    Aradi, D.3
  • 68
    • 85010931638 scopus 로고    scopus 로고
    • assessment of bleeding and thrombosis based on aspirin responsiveness after continuous-flow left ventricular assist device placement
    • Floroff, C.K., Rieger, K.L., Veasey, T.M., et al. assessment of bleeding and thrombosis based on aspirin responsiveness after continuous-flow left ventricular assist device placement. ASAIO J, 2017.
    • (2017) ASAIO J
    • Floroff, C.K.1    Rieger, K.L.2    Veasey, T.M.3
  • 69
    • 85006897194 scopus 로고    scopus 로고
    • Shear-mediated platelet activation in the free flow: perspectives on the emerging spectrum of cell mechanobiological mechanisms mediating cardiovascular implant thrombosis
    • Slepian, M.J., Sheriff, J., Hutchinson, M., et al. Shear-mediated platelet activation in the free flow: perspectives on the emerging spectrum of cell mechanobiological mechanisms mediating cardiovascular implant thrombosis. J Biomech 50 (2017), 20–25.
    • (2017) J Biomech , vol.50 , pp. 20-25
    • Slepian, M.J.1    Sheriff, J.2    Hutchinson, M.3
  • 70
    • 84892182928 scopus 로고    scopus 로고
    • Ambient hemolysis and activation of coagulation is different between HeartMate II and HeartWare left ventricular assist devices
    • Birschmann, I., Dittrich, M., Eller, T., et al. Ambient hemolysis and activation of coagulation is different between HeartMate II and HeartWare left ventricular assist devices. J Heart Lung Transplant 33 (2014), 80–87.
    • (2014) J Heart Lung Transplant , vol.33 , pp. 80-87
    • Birschmann, I.1    Dittrich, M.2    Eller, T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.