메뉴 건너뛰기




Volumn 29, Issue 6, 2010, Pages 616-624

Post-operative heparin may not be required for transitioning patients with a HeartMate II left ventricular assist system to long-term warfarin therapy

Author keywords

anticoagulation management; HeartMate II; heparin; LVAD; thrombosis

Indexed keywords

ACETYLSALICYLIC ACID; CLOPIDOGREL; DIPYRIDAMOLE; HEPARIN; PENTOXIFYLLINE; WARFARIN; ANTICOAGULANT AGENT;

EID: 77952583879     PISSN: 10532498     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.healun.2010.02.003     Document Type: Article
Times cited : (120)

References (17)
  • 1
    • 0035892018 scopus 로고    scopus 로고
    • Long-term mechanical left ventricular assistance for end-stage heart failure
    • Rose E.A., Gelijns A.C., Moskowitz A.J., et al. Long-term mechanical left ventricular assistance for end-stage heart failure. N Engl J Med 345 (2001) 1435-1443
    • (2001) N Engl J Med , vol.345 , pp. 1435-1443
    • Rose, E.A.1    Gelijns, A.C.2    Moskowitz, A.J.3
  • 2
    • 0035783884 scopus 로고    scopus 로고
    • Multicenter clinical evaluation of the HeartMate vented electric left ventricular assist system in patients awaiting heart transplantation
    • Frazier O.H., Rose E.A., Oz M.C., et al. Multicenter clinical evaluation of the HeartMate vented electric left ventricular assist system in patients awaiting heart transplantation. J Thorac Cardiovasc Surg 122 (2001) 1186-1195
    • (2001) J Thorac Cardiovasc Surg , vol.122 , pp. 1186-1195
    • Frazier, O.H.1    Rose, E.A.2    Oz, M.C.3
  • 3
    • 34548311569 scopus 로고    scopus 로고
    • Use of a continuous-flow device in patients awaiting heart transplantation
    • Miller L.W., Pagani F.D., Russell S.D., et al. Use of a continuous-flow device in patients awaiting heart transplantation. N Engl J Med 357 (2007) 885-896
    • (2007) N Engl J Med , vol.357 , pp. 885-896
    • Miller, L.W.1    Pagani, F.D.2    Russell, S.D.3
  • 4
    • 67650093608 scopus 로고    scopus 로고
    • Extended mechanical circulatory support with a continuous-flow rotary left ventricular assist device
    • Pagani F.D., Miller L.W., Russell S.D., et al. Extended mechanical circulatory support with a continuous-flow rotary left ventricular assist device. J Am Coll Cardiol 54 (2009) 312-321
    • (2009) J Am Coll Cardiol , vol.54 , pp. 312-321
    • Pagani, F.D.1    Miller, L.W.2    Russell, S.D.3
  • 5
    • 73349129701 scopus 로고    scopus 로고
    • Advanced heart failure treated with continuous-flow left ventricular assist device
    • Slaughter M.S., Rogers J.G., Milano C.A., et al. Advanced heart failure treated with continuous-flow left ventricular assist device. N Engl J Med 361 (2009) 2241-2251
    • (2009) N Engl J Med , vol.361 , pp. 2241-2251
    • Slaughter, M.S.1    Rogers, J.G.2    Milano, C.A.3
  • 6
    • 56249139674 scopus 로고    scopus 로고
    • Low thromboembolic risk for patients with the HeartMate II left ventricular assist device
    • John R., Kamdar F., Liao K., et al. Low thromboembolic risk for patients with the HeartMate II left ventricular assist device. J Thorac Cardiovasc Surg 136 (2008) 1318-1323
    • (2008) J Thorac Cardiovasc Surg , vol.136 , pp. 1318-1323
    • John, R.1    Kamdar, F.2    Liao, K.3
  • 7
    • 68949202239 scopus 로고    scopus 로고
    • Low thromboembolism and pump thrombosis with the HeartMate II left ventricular assist device: analysis of outpatient anti-coagulation
    • Boyle A.J., Russell S.D., Teuteberg J.J., et al. Low thromboembolism and pump thrombosis with the HeartMate II left ventricular assist device: analysis of outpatient anti-coagulation. J Heart Lung Transplant 28 (2009) 881-887
    • (2009) J Heart Lung Transplant , vol.28 , pp. 881-887
    • Boyle, A.J.1    Russell, S.D.2    Teuteberg, J.J.3
  • 8
    • 74249110561 scopus 로고    scopus 로고
    • European results with a continuous-flow ventricular assist device for advanced heart-failure patients
    • in press
    • Lahpor J, Khaghani A, Hetzer R, et al. European results with a continuous-flow ventricular assist device for advanced heart-failure patients. Eur J Cardiothorac Surg (in press).
    • Eur J Cardiothorac Surg
    • Lahpor, J.1    Khaghani, A.2    Hetzer, R.3
  • 9
    • 46949087096 scopus 로고    scopus 로고
    • HeartMate II left ventricular assist device; early European experience
    • Struber M., Sander K., Lahpor J., et al. HeartMate II left ventricular assist device; early European experience. Eur J Cardiothorac Surg 34 (2008) 289-294
    • (2008) Eur J Cardiothorac Surg , vol.34 , pp. 289-294
    • Struber, M.1    Sander, K.2    Lahpor, J.3
  • 10
    • 0035106218 scopus 로고    scopus 로고
    • HeartMate II left ventricular assist system: from concept to first clinical use
    • Griffith B.P., Kormos R.L., Borovetz H.S., et al. HeartMate II left ventricular assist system: from concept to first clinical use. Ann Thorac Surg 71 suppl (2001) S116-S120
    • (2001) Ann Thorac Surg , vol.71 , Issue.SUPPL
    • Griffith, B.P.1    Kormos, R.L.2    Borovetz, H.S.3
  • 11
    • 0034823947 scopus 로고    scopus 로고
    • HeartMate left ventricular assist devices: a multigeneration of implanted blood pumps
    • Maher T.R., Butler K.C., Poirier V.L., et al. HeartMate left ventricular assist devices: a multigeneration of implanted blood pumps. Artif Organs 25 (2001) 422-426
    • (2001) Artif Organs , vol.25 , pp. 422-426
    • Maher, T.R.1    Butler, K.C.2    Poirier, V.L.3
  • 12
    • 52949101656 scopus 로고    scopus 로고
    • INTERMACS database for durable devices for circulatory support: first annual report
    • Kirklin J.K., Naftel D.C., Stevenson L.W., et al. INTERMACS database for durable devices for circulatory support: first annual report. J Heart Lung Transplant 27 (2008) 1065-1072
    • (2008) J Heart Lung Transplant , vol.27 , pp. 1065-1072
    • Kirklin, J.K.1    Naftel, D.C.2    Stevenson, L.W.3
  • 13
    • 0032936154 scopus 로고    scopus 로고
    • Vitamin K reduces bleeding in left ventricular assist device recipients
    • Kaplon R.J., Gillinov A.M., Smedira N.G., et al. Vitamin K reduces bleeding in left ventricular assist device recipients. J Heart Lung Transplant 18 (1999) 346-350
    • (1999) J Heart Lung Transplant , vol.18 , pp. 346-350
    • Kaplon, R.J.1    Gillinov, A.M.2    Smedira, N.G.3
  • 14
    • 10244252721 scopus 로고    scopus 로고
    • Increased activation of the coagulation and fibrinolytic systems leads to hemorrhagic complications during left ventricular assist implantation
    • Livingston E.R., Fisher C.A., Bibidakis E.J., et al. Increased activation of the coagulation and fibrinolytic systems leads to hemorrhagic complications during left ventricular assist implantation. Circulation 94 (1996) II-227-II-234
    • (1996) Circulation , vol.94
    • Livingston, E.R.1    Fisher, C.A.2    Bibidakis, E.J.3
  • 15
    • 38349143974 scopus 로고    scopus 로고
    • Fibrinolytic activation during long-term support with the HeartMate II left ventricular assist device
    • Slaughter M.S., Sobieski M.A., Gallagher C., et al. Fibrinolytic activation during long-term support with the HeartMate II left ventricular assist device. ASAIO J 54 (2008) 115-119
    • (2008) ASAIO J , vol.54 , pp. 115-119
    • Slaughter, M.S.1    Sobieski, M.A.2    Gallagher, C.3
  • 16
    • 40649123746 scopus 로고    scopus 로고
    • Non-surgical bleeding in patients with ventricular assist devices could be explained by acquired von Willebrand disease
    • Geisen U., Heilmann C., Beyersdorf F., et al. Non-surgical bleeding in patients with ventricular assist devices could be explained by acquired von Willebrand disease. Eur J Cardiothorac Surg 33 (2008) 679-684
    • (2008) Eur J Cardiothorac Surg , vol.33 , pp. 679-684
    • Geisen, U.1    Heilmann, C.2    Beyersdorf, F.3
  • 17
    • 66149135264 scopus 로고    scopus 로고
    • Severely impaired von Willebrand factor-dependent platelet aggregation in patients with a continuous-flow left ventricular assist device (HeartMate II)
    • Klovaite J., Gustafsson F., Mortensen S.A., et al. Severely impaired von Willebrand factor-dependent platelet aggregation in patients with a continuous-flow left ventricular assist device (HeartMate II). J Am Coll Cardiol 53 (2009) 2162-2167
    • (2009) J Am Coll Cardiol , vol.53 , pp. 2162-2167
    • Klovaite, J.1    Gustafsson, F.2    Mortensen, S.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.