-
1
-
-
79955615630
-
Results of the post-U.S. Food and Drug Administration-approval study with a continuous flow left ventricular assist device as a bridge to heart transplantation: a prospective study using the INTERMACS (Interagency Registry for Mechanically Assisted Circulatory Support)
-
1 Starling, R.C., Naka, Y., Boyle, A.J., et al. Results of the post-U.S. Food and Drug Administration-approval study with a continuous flow left ventricular assist device as a bridge to heart transplantation: a prospective study using the INTERMACS (Interagency Registry for Mechanically Assisted Circulatory Support). J Am Coll Cardiol 57 (2011), 1890–1898.
-
(2011)
J Am Coll Cardiol
, vol.57
, pp. 1890-1898
-
-
Starling, R.C.1
Naka, Y.2
Boyle, A.J.3
-
2
-
-
84958587026
-
Adverse events in contemporary continuous-flow left ventricular assist devices: a multi-institutional comparison shows significant differences
-
2 Stulak, J.M., Davis, M.E., Haglund, N., et al. Adverse events in contemporary continuous-flow left ventricular assist devices: a multi-institutional comparison shows significant differences. J Thorac Cardiovasc Surg 151 (2016), 177–189.
-
(2016)
J Thorac Cardiovasc Surg
, vol.151
, pp. 177-189
-
-
Stulak, J.M.1
Davis, M.E.2
Haglund, N.3
-
3
-
-
84892148459
-
Unexpected abrupt increase in left ventricular assist device thrombosis
-
3 Starling, R.C., Moazami, N., Silvestry, S.C., et al. Unexpected abrupt increase in left ventricular assist device thrombosis. N Engl J Med 370 (2014), 33–40.
-
(2014)
N Engl J Med
, vol.370
, pp. 33-40
-
-
Starling, R.C.1
Moazami, N.2
Silvestry, S.C.3
-
4
-
-
84892177900
-
Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) analysis of pump thrombosis in the HeartMate II left ventricular assist device
-
4 Kirklin, J.K., Naftel, D.C., Kormos, R.L., et al. Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) analysis of pump thrombosis in the HeartMate II left ventricular assist device. J Heart Lung Transplant 33 (2014), 12–22.
-
(2014)
J Heart Lung Transplant
, vol.33
, pp. 12-22
-
-
Kirklin, J.K.1
Naftel, D.C.2
Kormos, R.L.3
-
5
-
-
84939969295
-
Management of pump thrombosis in patients with left ventricular assist devices
-
5 Stulak, J.M., Sharma, S., Maltais, S., Management of pump thrombosis in patients with left ventricular assist devices. Am J Cardiovasc Drugs 15 (2015), 89–94.
-
(2015)
Am J Cardiovasc Drugs
, vol.15
, pp. 89-94
-
-
Stulak, J.M.1
Sharma, S.2
Maltais, S.3
-
6
-
-
84898754538
-
A different perspective on thrombosis and the HeartMate II
-
6 Stulak, J.M., Maltais, S., A different perspective on thrombosis and the HeartMate II. N Engl J Med 370 (2014), 1467–1468.
-
(2014)
N Engl J Med
, vol.370
, pp. 1467-1468
-
-
Stulak, J.M.1
Maltais, S.2
-
7
-
-
84892141967
-
An analysis of pump thrombus events in patients in the HeartWare ADVANCE bridge to transplant and continued access protocol trial
-
7 Najjar, S.S., Slaughter, M.S., Pagani, F.D., et al. An analysis of pump thrombus events in patients in the HeartWare ADVANCE bridge to transplant and continued access protocol trial. J Heart Lung Transplant 33 (2014), 23–34.
-
(2014)
J Heart Lung Transplant
, vol.33
, pp. 23-34
-
-
Najjar, S.S.1
Slaughter, M.S.2
Pagani, F.D.3
-
8
-
-
58249093243
-
Gastrointestinal bleeding rates in recipients of nonpulsatile and pulsatile left ventricular assist devices
-
8 Crow, S., John, R., Boyle, A., et al. Gastrointestinal bleeding rates in recipients of nonpulsatile and pulsatile left ventricular assist devices. J Thorac Cardiovasc Surg 137 (2009), 208–215.
-
(2009)
J Thorac Cardiovasc Surg
, vol.137
, pp. 208-215
-
-
Crow, S.1
John, R.2
Boyle, A.3
-
9
-
-
77957561535
-
Acquired von Willebrand syndrome after continuous-flow mechanical device support contributes to a high prevalence of bleeding during long-term support and at the time of transplantation
-
9 Uriel, N., Pak, S.W., Jorde, U.P., et al. Acquired von Willebrand syndrome after continuous-flow mechanical device support contributes to a high prevalence of bleeding during long-term support and at the time of transplantation. J Am Coll Cardiol 56 (2010), 1207–1213.
-
(2010)
J Am Coll Cardiol
, vol.56
, pp. 1207-1213
-
-
Uriel, N.1
Pak, S.W.2
Jorde, U.P.3
-
10
-
-
78650096247
-
The development of aortic insufficiency in left ventricular assist device-supported patients
-
10 Cowger, J., Pagani, F.D., Haft, J.W., Romano, M.A., Aaronson, K.D., Kolias, T.J., The development of aortic insufficiency in left ventricular assist device-supported patients. Circ Heart Fail 3 (2010), 668–674.
-
(2010)
Circ Heart Fail
, vol.3
, pp. 668-674
-
-
Cowger, J.1
Pagani, F.D.2
Haft, J.W.3
Romano, M.A.4
Aaronson, K.D.5
Kolias, T.J.6
-
11
-
-
84885295201
-
Surgical technique influences HeartMate II left ventricular assist device thrombosis
-
11 Taghavi, S., Ward, C., Jayarajan, S.N., Gaughan, J., Wilson, L.M., Mangi, A.A., Surgical technique influences HeartMate II left ventricular assist device thrombosis. Ann Thorac Surg 96 (2013), 1259–1265.
-
(2013)
Ann Thorac Surg
, vol.96
, pp. 1259-1265
-
-
Taghavi, S.1
Ward, C.2
Jayarajan, S.N.3
Gaughan, J.4
Wilson, L.M.5
Mangi, A.A.6
-
12
-
-
84892157543
-
Device thrombosis in HeartMate II continuous-flow left ventricular assist devices: a multifactorial phenomenon
-
12 Uriel, N., Han, J., Morrison, K.A., et al. Device thrombosis in HeartMate II continuous-flow left ventricular assist devices: a multifactorial phenomenon. J Heart Lung Transplant 33 (2014), 51–59.
-
(2014)
J Heart Lung Transplant
, vol.33
, pp. 51-59
-
-
Uriel, N.1
Han, J.2
Morrison, K.A.3
-
13
-
-
84951573411
-
Radiologic assessment of HeartMate II position: minimal pump migration after long-term support
-
13 Adamson, R.M., Bower, B.L., Sundareswaran, K.S., Farrar, D.J., Dembitsky, W.P., Radiologic assessment of HeartMate II position: minimal pump migration after long-term support. J Heart Lung Transplant 34 (2015), 1617–1623.
-
(2015)
J Heart Lung Transplant
, vol.34
, pp. 1617-1623
-
-
Adamson, R.M.1
Bower, B.L.2
Sundareswaran, K.S.3
Farrar, D.J.4
Dembitsky, W.P.5
-
14
-
-
84924158127
-
Principles of HeartMate II implantation to avoid pump malposition and migration
-
14 Adamson, R.M., Mangi, A.A., Kormos, R.L., Farrar, D.J., Dembitsky, W.P., Principles of HeartMate II implantation to avoid pump malposition and migration. J Card Surg 30 (2015), 296–299.
-
(2015)
J Card Surg
, vol.30
, pp. 296-299
-
-
Adamson, R.M.1
Mangi, A.A.2
Kormos, R.L.3
Farrar, D.J.4
Dembitsky, W.P.5
-
15
-
-
84942821512
-
Factors related to pump thrombosis with the Heartmate II left ventricular assist device
-
15 Klodell, C.T., Massey, H.T., Adamson, R.M., et al. Factors related to pump thrombosis with the Heartmate II left ventricular assist device. J Card Surg 30 (2015), 775–780.
-
(2015)
J Card Surg
, vol.30
, pp. 775-780
-
-
Klodell, C.T.1
Massey, H.T.2
Adamson, R.M.3
-
16
-
-
84962136646
-
Clinical trial design and rationale of the Multicenter Study of MagLev Technology in Patients Undergoing Mechanical Circulatory Support Therapy With HeartMate 3 (MOMENTUM 3) investigational device exemption clinical study protocol
-
16 Heatley, G., Sood, P., Goldstein, D., et al. Clinical trial design and rationale of the Multicenter Study of MagLev Technology in Patients Undergoing Mechanical Circulatory Support Therapy With HeartMate 3 (MOMENTUM 3) investigational device exemption clinical study protocol. J Heart Lung Transplant 35 (2016), 528–536.
-
(2016)
J Heart Lung Transplant
, vol.35
, pp. 528-536
-
-
Heatley, G.1
Sood, P.2
Goldstein, D.3
-
17
-
-
84949753718
-
Seventh INTERMACS annual report: 15,000 patients and counting
-
17 Kirklin, J.K., Naftel, D.C., Pagani, F.D., et al. Seventh INTERMACS annual report: 15,000 patients and counting. J Heart Lung Transplant 34 (2015), 1495–1504.
-
(2015)
J Heart Lung Transplant
, vol.34
, pp. 1495-1504
-
-
Kirklin, J.K.1
Naftel, D.C.2
Pagani, F.D.3
-
18
-
-
84899643297
-
Results of the destination therapy post-Food and Drug Administration approval study with a continuous flow left ventricular assist device: a prospective study using the INTERMACS Registry (Interagency Registry for Mechanically Assisted Circulatory Support)
-
18 Jorde, U.P., Kushwaha, S.S., Tatooles, A.J., et al. Results of the destination therapy post-Food and Drug Administration approval study with a continuous flow left ventricular assist device: a prospective study using the INTERMACS Registry (Interagency Registry for Mechanically Assisted Circulatory Support). J Am Coll Cardiol 63 (2014), 1751–1757.
-
(2014)
J Am Coll Cardiol
, vol.63
, pp. 1751-1757
-
-
Jorde, U.P.1
Kushwaha, S.S.2
Tatooles, A.J.3
-
19
-
-
84895511147
-
Pre-operative risk factors of bleeding and stroke during left ventricular assist device support: an analysis of more than 900 HeartMate II outpatients
-
19 Boyle, A.J., Jorde, U.P., Sun, B., et al. Pre-operative risk factors of bleeding and stroke during left ventricular assist device support: an analysis of more than 900 HeartMate II outpatients. J Am Coll Cardiol 63 (2014), 880–888.
-
(2014)
J Am Coll Cardiol
, vol.63
, pp. 880-888
-
-
Boyle, A.J.1
Jorde, U.P.2
Sun, B.3
-
20
-
-
84949762286
-
Pump thrombosis in the Thoratec HeartMate II device: an update analysis of the INTERMACS Registry
-
20 Kirklin, J.K., Naftel, D.C., Pagani, F.D., et al. Pump thrombosis in the Thoratec HeartMate II device: an update analysis of the INTERMACS Registry. J Heart Lung Transplant 34 (2015), 1515–1526.
-
(2015)
J Heart Lung Transplant
, vol.34
, pp. 1515-1526
-
-
Kirklin, J.K.1
Naftel, D.C.2
Pagani, F.D.3
-
21
-
-
84942833950
-
High-speed visualization of disturbed pathlines in axial flow ventricular assist device under pulsatile conditions
-
21 Yang, F., Kormos, R.L., Antaki, J.F., High-speed visualization of disturbed pathlines in axial flow ventricular assist device under pulsatile conditions. J Thorac Cardiovasc Surg 150 (2015), 938–944.
-
(2015)
J Thorac Cardiovasc Surg
, vol.150
, pp. 938-944
-
-
Yang, F.1
Kormos, R.L.2
Antaki, J.F.3
-
22
-
-
85010031526
-
Factors related to pump thrombosis at select medium to high volume centers
-
Paper presented at: 34th Annual Meeting and Scientific Sessions, International Society of Heart and Lung Transplantation. April 10–13, San Diego, CA.
-
22 Klodell CT, Massey HT, Adamson R, et al. Factors related to pump thrombosis at select medium to high volume centers. Paper presented at: 34th Annual Meeting and Scientific Sessions, International Society of Heart and Lung Transplantation. April 10–13, 2014; San Diego, CA.
-
(2014)
-
-
Klodell, C.T.1
Massey, H.T.2
Adamson, R.3
-
23
-
-
84898763243
-
Increase in left ventricular assist device thrombosis
-
23 Hoefer, D., Velik-Salchner, C., Antretter, H., Increase in left ventricular assist device thrombosis. N Engl J Med, 370, 2014, 1464.
-
(2014)
N Engl J Med
, vol.370
, pp. 1464
-
-
Hoefer, D.1
Velik-Salchner, C.2
Antretter, H.3
-
24
-
-
84898746556
-
Increase in left ventricular assist device thrombosis
-
24 Schmitto, J.D., Avsar, M., Haverich, A., Increase in left ventricular assist device thrombosis. N Engl J Med 370 (2014), 1463–1464.
-
(2014)
N Engl J Med
, vol.370
, pp. 1463-1464
-
-
Schmitto, J.D.1
Avsar, M.2
Haverich, A.3
-
25
-
-
84864626166
-
Eptifibatide for the treatment of HeartMate II left ventricular assist device thrombosis
-
25 Al-Quthami, A.H., Jumean, M., Kociol, R., et al. Eptifibatide for the treatment of HeartMate II left ventricular assist device thrombosis. Circ Heart Fail 5 (2012), e68–e70.
-
(2012)
Circ Heart Fail
, vol.5
, pp. e68-e70
-
-
Al-Quthami, A.H.1
Jumean, M.2
Kociol, R.3
-
26
-
-
80053306096
-
Thrombosis and failure of a HeartMate II device in the absence of alarms
-
26 Bashir, J., Cheung, A., Kaan, A., Kearns, M., Ibey, A., Ignaszewski, A., Thrombosis and failure of a HeartMate II device in the absence of alarms. J Heart Lung Transplant 30 (2011), 1197–1199.
-
(2011)
J Heart Lung Transplant
, vol.30
, pp. 1197-1199
-
-
Bashir, J.1
Cheung, A.2
Kaan, A.3
Kearns, M.4
Ibey, A.5
Ignaszewski, A.6
-
27
-
-
84892163123
-
Hemolysis in left ventricular assist device: a retrospective analysis of outcomes
-
27 Ravichandran, A.K., Parker, J., Novak, E., et al. Hemolysis in left ventricular assist device: a retrospective analysis of outcomes. J Heart Lung Transplant 33 (2014), 44–50.
-
(2014)
J Heart Lung Transplant
, vol.33
, pp. 44-50
-
-
Ravichandran, A.K.1
Parker, J.2
Novak, E.3
-
28
-
-
84892151754
-
Gastrointestinal bleeding and subsequent risk of thromboembolic events during support with a left ventricular assist device
-
28 Stulak, J.M., Lee, D., Haft, J.W., et al. Gastrointestinal bleeding and subsequent risk of thromboembolic events during support with a left ventricular assist device. J Heart Lung Transplant 33 (2014), 60–64.
-
(2014)
J Heart Lung Transplant
, vol.33
, pp. 60-64
-
-
Stulak, J.M.1
Lee, D.2
Haft, J.W.3
-
29
-
-
84892158176
-
The vexing problem of thrombosis in long-term mechanical circulatory support
-
29 Mehra, M.R., Stewart, G.C., Uber, P.A., The vexing problem of thrombosis in long-term mechanical circulatory support. J Heart Lung Transplant 33 (2014), 1–11.
-
(2014)
J Heart Lung Transplant
, vol.33
, pp. 1-11
-
-
Mehra, M.R.1
Stewart, G.C.2
Uber, P.A.3
-
30
-
-
84892177900
-
Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) analysis of pump thrombosis in the HeartMate II left ventricular assist device
-
30 Kirkin, J.K., Naftel, D.C., Kormos, R.L., et al. Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) analysis of pump thrombosis in the HeartMate II left ventricular assist device. J Heart Lung Transplant 33 (2014), 12–22.
-
(2014)
J Heart Lung Transplant
, vol.33
, pp. 12-22
-
-
Kirkin, J.K.1
Naftel, D.C.2
Kormos, R.L.3
-
31
-
-
84905089756
-
Early elevations in pump power with the HeartMate II left ventricular assist device do not predict late adverse events
-
31 Salerno, C.T., Sundareswaran, K.S., Schleeter, T.P., Moanie, S.L., Farrar, D.J., Walsh, M.N., Early elevations in pump power with the HeartMate II left ventricular assist device do not predict late adverse events. J Heart Lung Transplant 33 (2014), 809–815.
-
(2014)
J Heart Lung Transplant
, vol.33
, pp. 809-815
-
-
Salerno, C.T.1
Sundareswaran, K.S.2
Schleeter, T.P.3
Moanie, S.L.4
Farrar, D.J.5
Walsh, M.N.6
-
32
-
-
84862840835
-
Successful treatment of early thrombosis of HeartWare left ventricular assist device with intraventricular thrombolytics
-
32 Kamouh, A., John, R., Eckman, P., Successful treatment of early thrombosis of HeartWare left ventricular assist device with intraventricular thrombolytics. Ann Thorac Surg 94 (2012), 281–283.
-
(2012)
Ann Thorac Surg
, vol.94
, pp. 281-283
-
-
Kamouh, A.1
John, R.2
Eckman, P.3
-
33
-
-
84894589687
-
Thrombolytic therapy for thrombosis of continuous flow ventricular assist devices
-
33 Schlendorf, K., Patel, C.B., Gehrig, T., et al. Thrombolytic therapy for thrombosis of continuous flow ventricular assist devices. J Card Fail 20 (2014), 91–97.
-
(2014)
J Card Fail
, vol.20
, pp. 91-97
-
-
Schlendorf, K.1
Patel, C.B.2
Gehrig, T.3
-
34
-
-
84949817077
-
Treatment of device thrombus in the HeartWare HVAD: success and outcomes depend significantly on the initial treatment strategy
-
34 Stulak, J.M., Dunlay, S.M., Sharma, S., et al. Treatment of device thrombus in the HeartWare HVAD: success and outcomes depend significantly on the initial treatment strategy. J Heart Lung Transplant 34 (2015), 1535–1541.
-
(2015)
J Heart Lung Transplant
, vol.34
, pp. 1535-1541
-
-
Stulak, J.M.1
Dunlay, S.M.2
Sharma, S.3
|