Volumn 9, Issue 4, 2015, Pages 895-910

Performance of cleared blood glucose monitors

Author keywords

Accuracy; BG monitor; FDA; Glucose; ISO; Performance

Indexed keywords

ANALYTICAL ERROR; BLOOD GLUCOSE MONITORING; CLINICAL ASSESSMENT; COST EFFECTIVENESS ANALYSIS; DECISION MAKING; ECONOMIC EVALUATION; EMPIRICISM; HEART INFARCTION; HUMAN; HYPOGLYCEMIA; MEDICAL DEVICE; REVIEW; SIMULATION; TREATMENT OUTCOME; UNITED STATES; ALGORITHM; ANALYSIS; BLOOD; CALIBRATION; DEVICES; DIABETES MELLITUS; FOOD AND DRUG ADMINISTRATION; GLUCOSE BLOOD LEVEL; POSTMARKETING SURVEILLANCE; REPRODUCIBILITY; STANDARD;

EID: 85018220249     PISSN: None     EISSN: 19322968     Source Type: Journal    
DOI: 10.1177/1932296815584797     Document Type: Review
Times cited : (53)

References (38)
  • 1
    • 85028548194 scopus 로고    scopus 로고
    • Endocrine Today, October 1, Accessed April 8, 2015
    • Endocrine Today. Poor performance of blood glucose monitors prompts call to action. October 1, 2013. http://www. healio.com/endocrinology/diabetes/news/print/endocrinetoday/% 7B9119eae5-4781-4c64-a2ac-7476ca45aa98%7D/poor-performance-of-blood-glucose-monitors-prompts-callto-action. Accessed April 8, 2015.
    • (2013) Poor Performance of Blood Glucose Monitors Prompts Call to Action
  • 3
    • 84900540435 scopus 로고    scopus 로고
    • Assessing the analytical performance of systems for self-monitoring of blood glucose: Concepts of performance evaluation and definition of metrological key terms
    • Schnell O, Hinzmann R, Kulzer B, et al. Assessing the analytical performance of systems for self-monitoring of blood glucose: concepts of performance evaluation and definition of metrological key terms. J Diabetes Sci Technol. 2013;7(6):1585-1594.
    • (2013) J Diabetes Sci Technol , vol.7 , Issue.6 , pp. 1585-1594
    • Schnell, O.1    Hinzmann, R.2    Kulzer, B.3
  • 4
    • 78349287412 scopus 로고    scopus 로고
    • The Food and Drug Administration is now preparing to establish tighter performance requirements for blood glucose monitors
    • Klonoff DC. The Food and Drug Administration is now preparing to establish tighter performance requirements for blood glucose monitors. J Diabetes Sci Technol. 2010;4(3): 499-504.
    • (2010) J Diabetes Sci Technol , vol.4 , Issue.3 , pp. 499-504
    • Klonoff, D.C.1
  • 8
    • 84942921165 scopus 로고    scopus 로고
    • Setting the bar for blood glucose meter performance
    • January 9, Accessed April 8, 2015
    • Lias C. Setting the bar for blood glucose meter performance. FDA Voice; January 9, 2014. http://blogs.fda.gov/fdavoice/? s=Setting+the+Bar+for+Blood+Glucose+Meter+Performance. Accessed April 8, 2015
    • (2014) FDA Voice
    • Lias, C.1
  • 9
    • 77249122160 scopus 로고    scopus 로고
    • System accuracy evaluation of 27 blood glucose monitoring systems according to DIN en ISO 15197
    • Freckmann G, Baumstark A, Jendrike N, et al. System accuracy evaluation of 27 blood glucose monitoring systems according to DIN EN ISO 15197. Diabetes Technol Ther. 2010;12(3):221-231.
    • (2010) Diabetes Technol Ther , vol.12 , Issue.3 , pp. 221-231
    • Freckmann, G.1    Baumstark, A.2    Jendrike, N.3
  • 10
    • 77957660358 scopus 로고    scopus 로고
    • The accuracy of home glucose meters in hypoglycemia
    • Sonmez A, Yilmaz Z, Uckaya G, et al. The accuracy of home glucose meters in hypoglycemia. Diabetes Technol Ther. 2010;12(8):619-626.
    • (2010) Diabetes Technol Ther , vol.12 , Issue.8 , pp. 619-626
    • Sonmez, A.1    Yilmaz, Z.2    Uckaya, G.3
  • 11
    • 84859313151 scopus 로고    scopus 로고
    • Accuracy evaluation of five blood glucose monitoring systems obtained from the pharmacy: A European multicenter study with 453 subjects
    • Tack C, Pohlmeier H, Behnke T, et al. Accuracy evaluation of five blood glucose monitoring systems obtained from the pharmacy: a European multicenter study with 453 subjects. Diabetes Technol Ther. 2012;14(4):330-337.
    • (2012) Diabetes Technol Ther , vol.14 , Issue.4 , pp. 330-337
    • Tack, C.1    Pohlmeier, H.2    Behnke, T.3
  • 12
    • 84875805117 scopus 로고    scopus 로고
    • System accuracy evaluation of 43 blood glucose monitoring systems for self-monitoring of blood glucose according to DIN en ISO 15197
    • Freckmann G, Schmid C, Baumstark A, Pleus S, Link M, Haug C. System accuracy evaluation of 43 blood glucose monitoring systems for self-monitoring of blood glucose according to DIN EN ISO 15197. J Diabetes Sci Technol. 2012;6(5):1060-1075.
    • (2012) J Diabetes Sci Technol , vol.6 , Issue.5 , pp. 1060-1075
    • Freckmann, G.1    Schmid, C.2    Baumstark, A.3    Pleus, S.4    Link, M.5    Haug, C.6
  • 13
    • 84875803673 scopus 로고    scopus 로고
    • Lot-to-lot variability of test strips and accuracy assessment of systems for self-monitoring of blood glucose according to ISO 15197
    • Baumstark A, Pleus S, Schmid C, Link M, Haug C, Freckmann G. Lot-to-lot variability of test strips and accuracy assessment of systems for self-monitoring of blood glucose according to ISO 15197. J Diabetes Sci Technol. 2012;6(5):1076-1086.
    • (2012) J Diabetes Sci Technol , vol.6 , Issue.5 , pp. 1076-1086
    • Baumstark, A.1    Pleus, S.2    Schmid, C.3    Link, M.4    Haug, C.5    Freckmann, G.6
  • 14
    • 84882939981 scopus 로고    scopus 로고
    • Performance variability of seven commonly used self-monitoring of blood glucose systems: Clinical considerations for patients and providers
    • Brazg RL, Klaff LJ, Parkin CG. Performance variability of seven commonly used self-monitoring of blood glucose systems: clinical considerations for patients and providers. J Diabetes Sci Technol. 2013;7(1):144-152.
    • (2013) J Diabetes Sci Technol , vol.7 , Issue.1 , pp. 144-152
    • Brazg, R.L.1    Klaff, L.J.2    Parkin, C.G.3
  • 15
    • 84892649142 scopus 로고    scopus 로고
    • Evaluation of 12 blood glucose monitoring systems for selftesting: System accuracy and measurement reproducibility
    • Freckmann G, Baumstark A, Schmid C, Pleus S, Link M, Haug C. Evaluation of 12 blood glucose monitoring systems for selftesting: system accuracy and measurement reproducibility. Diabetes Technol Ther. 2014;16(2):113-122.
    • (2014) Diabetes Technol Ther , vol.16 , Issue.2 , pp. 113-122
    • Freckmann, G.1    Baumstark, A.2    Schmid, C.3    Pleus, S.4    Link, M.5    Haug, C.6
  • 16
    • 84893247079 scopus 로고    scopus 로고
    • Performance of blood glucose meters in compliance with current and future clinical ISO15197 accuracy criteria
    • Pfützner A, Hengesbach C, Demircik F, Schipper C, Forst T, Musholt PB. Performance of blood glucose meters in compliance with current and future clinical ISO15197 accuracy criteria. Curr Med Res Opin. 2014;30(2):185-190.
    • (2014) Curr Med Res Opin , vol.30 , Issue.2 , pp. 185-190
    • Pfützner, A.1    Hengesbach, C.2    Demircik, F.3    Schipper, C.4    Forst, T.5    Musholt, P.B.6
  • 17
    • 84900791705 scopus 로고    scopus 로고
    • Accuracy evaluation of three systems for self-monitoring of blood glucose with three different test strip lots following ISO 15197
    • Link M, Pleus S, Schmid C, et al. Accuracy evaluation of three systems for self-monitoring of blood glucose with three different test strip lots following ISO 15197. J Diabetes Sci Technol. 2014;8(2):422-424.
    • (2014) J Diabetes Sci Technol , vol.8 , Issue.2 , pp. 422-424
    • Link, M.1    Pleus, S.2    Schmid, C.3
  • 18
    • 84900823184 scopus 로고    scopus 로고
    • Analytical performance of glucose monitoring systems at different blood glucose ranges and analysis of outliers in a clinical setting
    • Hasslacher C, Kulozik F, Platten I. Analytical performance of glucose monitoring systems at different blood glucose ranges and analysis of outliers in a clinical setting. J Diabetes Sci Technol. 2014;8(3):466-472.
    • (2014) J Diabetes Sci Technol , vol.8 , Issue.3 , pp. 466-472
    • Hasslacher, C.1    Kulozik, F.2    Platten, I.3
  • 19
    • 84896124490 scopus 로고    scopus 로고
    • Evaluation of accuracy of FAD-GDH- and mutant Q-GDH-based blood glucose monitors in multi-patient populations
    • Huang TY, Chang HW, Tsao MF, et al. Evaluation of accuracy of FAD-GDH- and mutant Q-GDH-based blood glucose monitors in multi-patient populations. Clin Chim Acta. 2014;433:28-33.
    • (2014) Clin Chim Acta , vol.433 , pp. 28-33
    • Huang, T.Y.1    Chang, H.W.2    Tsao, M.F.3
  • 20
    • 84983493051 scopus 로고    scopus 로고
    • US Food and Drug Administration, Accessed February 15
    • US Food and Drug Administration. 510(k) premarket notification. http://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfPMN/pmn.cfm. Accessed February 15, 2015.
    • (2015) 510(k) Premarket Notification
  • 21
    • 85028526153 scopus 로고    scopus 로고
    • U.S. Food and Drug Administration, Accessed February 15
    • U.S. Food and Drug Administration. "CLIA - Clinical Laboratory Improvement Amendments - Currently Waived Analytes." Accessed February 15, 2015. http://www.access data.fda.gov/scripts/cdrh/cfdocs/cfClia/analyteswaived.cfm? start-search=G.
    • (2015) CLIA - Clinical Laboratory Improvement Amendments - Currently Waived Analytes
  • 22
    • 0035130886 scopus 로고    scopus 로고
    • Quality specifications for glucose meters: Assessment by simulation modeling of errors in insulin dose
    • Boyd JC, Bruns DE. Quality specifications for glucose meters: assessment by simulation modeling of errors in insulin dose. Clin Chem. 2001;47(2):209-214.
    • (2001) Clin Chem , vol.47 , Issue.2 , pp. 209-214
    • Boyd, J.C.1    Bruns, D.E.2
  • 23
    • 71549156881 scopus 로고    scopus 로고
    • Monte Carlo simulation in establishing analytical quality requirements for clinical laboratory tests meeting clinical needs
    • Boyd JC, Bruns DE. Monte Carlo simulation in establishing analytical quality requirements for clinical laboratory tests meeting clinical needs. Methods Enzymol. 2009;467:411-433.
    • (2009) Methods Enzymol , vol.467 , pp. 411-433
    • Boyd, J.C.1    Bruns, D.E.2
  • 24
    • 78149382135 scopus 로고    scopus 로고
    • Impact of blood glucose self-monitoring errors on glucose variability, risk for hypoglycemia, and average glucose control in type 1 diabetes: An in silico study
    • Breton MD, Kovatchev BP. Impact of blood glucose self-monitoring errors on glucose variability, risk for hypoglycemia, and average glucose control in type 1 diabetes: an in silico study. J Diabetes Sci Technol. 2010;4(3):562-570.
    • (2010) J Diabetes Sci Technol , vol.4 , Issue.3 , pp. 562-570
    • Breton, M.D.1    Kovatchev, B.P.2
  • 25
    • 84860672792 scopus 로고    scopus 로고
    • Evaluating the efficacy of closed-loop glucose regulation via control-variability grid analysis
    • Magni L, Raimondo DM, Man CD, et al. Evaluating the efficacy of closed-loop glucose regulation via control-variability grid analysis. J Diabetes Sci Technol. 2008;2(4):630-635.
    • (2008) J Diabetes Sci Technol , vol.2 , Issue.4 , pp. 630-635
    • Magni, L.1    Raimondo, D.M.2    Man, C.D.3
  • 26
    • 77953148918 scopus 로고    scopus 로고
    • Glucose meter performance criteria for tight glycemic control estimated by simulation modeling
    • Karon BS, Boyd JC, Klee GG. Glucose meter performance criteria for tight glycemic control estimated by simulation modeling. Clin Chem. 2010;56(7):1091-1097.
    • (2010) Clin Chem , vol.56 , Issue.7 , pp. 1091-1097
    • Karon, B.S.1    Boyd, J.C.2    Klee, G.G.3
  • 27
    • 84873189111 scopus 로고    scopus 로고
    • Importance of blood glucose meter and carbohydrate estimation accuracy
    • Virdi NS, Mahoney JJ. Importance of blood glucose meter and carbohydrate estimation accuracy. J Diabetes Sci Technol. 2012;6(4):921-926.
    • (2012) J Diabetes Sci Technol , vol.6 , Issue.4 , pp. 921-926
    • Virdi, N.S.1    Mahoney, J.J.2
  • 28
    • 84889666505 scopus 로고    scopus 로고
    • Empiric validation of simulation models for estimating glucose meter performance criteria for moderate levels of glycemic control
    • Karon BS, Boyd JC, Klee GG. Empiric validation of simulation models for estimating glucose meter performance criteria for moderate levels of glycemic control. Diabetes Technol Ther. 2013;15(12):996-1003.
    • (2013) Diabetes Technol Ther , vol.15 , Issue.12 , pp. 996-1003
    • Karon, B.S.1    Boyd, J.C.2    Klee, G.G.3
  • 29
    • 84900810008 scopus 로고    scopus 로고
    • Continuous glucose monitoring in newborn infants: How do errors in calibration measurements affect detected hypoglycemia?
    • Thomas F, Signal M, Harris DL, et al. Continuous glucose monitoring in newborn infants: how do errors in calibration measurements affect detected hypoglycemia? J Diabetes Sci Technol. 2014;8(3):543-550.
    • (2014) J Diabetes Sci Technol , vol.8 , Issue.3 , pp. 543-550
    • Thomas, F.1    Signal, M.2    Harris, D.L.3
  • 30
    • 84891446217 scopus 로고    scopus 로고
    • Clinical implications and economic impact of accuracy differences among commercially available blood glucose monitoring systems
    • Budiman ES, Samant N, Resch A. Clinical implications and economic impact of accuracy differences among commercially available blood glucose monitoring systems. J Diabetes Sci Technol. 2013;7(2):365-380.
    • (2013) J Diabetes Sci Technol , vol.7 , Issue.2 , pp. 365-380
    • Budiman, E.S.1    Samant, N.2    Resch, A.3
  • 31
    • 84900540435 scopus 로고    scopus 로고
    • Assessing the analytical performance of systems for self-monitoring of blood glucose: Concepts of performance evaluation and definition of metrological key terms
    • Schnell O, Hinzmann R, Kulzer B, et al. Assessing the analytical performance of systems for self-monitoring of blood glucose: concepts of performance evaluation and definition of metrological key terms. J Diabetes Sci Technol. 2013;7(6):1585-1594.
    • (2013) J Diabetes Sci Technol , vol.7 , Issue.6 , pp. 1585-1594
    • Schnell, O.1    Hinzmann, R.2    Kulzer, B.3
  • 32
    • 84900801034 scopus 로고    scopus 로고
    • Impact of a reduced error range of SMBG in insulin-treated patients in Germany
    • Schnell O, Erbach M. Impact of a reduced error range of SMBG in insulin-treated patients in Germany. J Diabetes Sci Technol. 2014;8(3):479-482.
    • (2014) J Diabetes Sci Technol , vol.8 , Issue.3 , pp. 479-482
    • Schnell, O.1    Erbach, M.2
  • 33
    • 84928313470 scopus 로고    scopus 로고
    • US Food and Drug Administration, Accessed April 8
    • US Food and Drug Administration. National medical device postmarket surveillance plan. http://www.fda.gov/AboutFDA/CentersOffices/OfficeofMedicalProductsandTobacco/CDRH/CDRHReports/ucm301912.htm. Accessed April 8, 2015.
    • (2015) National Medical Device Postmarket Surveillance Plan
  • 34
    • 78149349684 scopus 로고    scopus 로고
    • US Food and Drug Administration, Accessed April 8
    • US Food and Drug Administration. FDA's sentinel initiative. http://www.fda.gov/Safety/FDAsSentinelInitiative/default. htm. Accessed April 8, 2015.
    • (2015) FDA's Sentinel Initiative
  • 35
    • 84867748876 scopus 로고    scopus 로고
    • US Food and Drug Administration, September, Accessed April 8, 2015
    • US Food and Drug Administration. Strengthening our national system for medical device postmarket surveillance. September 2012. http://www.fda.gov/downloads/AboutFDA/CentersOffices/OfficeofMedicalProductsandTobacco/CDRH/CDRHReports/UCM301924.pdf. Accessed April 8, 2015.
    • (2012) Strengthening Our National System for Medical Device Postmarket Surveillance
  • 38
    • 84897122879 scopus 로고    scopus 로고
    • Do currently available blood glucose monitors meet regulatory standards? 1-day public meeting in Arlington, Virginia
    • Klonoff DC, Reyes JS. Do currently available blood glucose monitors meet regulatory standards? 1-day public meeting in Arlington, Virginia. J Diabetes Sci Technol. 2013;7(4):1071-1083.
    • (2013) J Diabetes Sci Technol , vol.7 , Issue.4 , pp. 1071-1083
    • Klonoff, D.C.1    Reyes, J.S.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.