메뉴 건너뛰기




Volumn 12, Issue 4, 2017, Pages

A novel smart navigation system for intramedullary nailing in orthopedic surgery

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; BIOSENSOR; BONE DRILL; INTRAMEDULLARY NAILING; LASER; MATHEMATICAL COMPUTING; ORTHOPEDIC SURGERY; SURGICAL DRILL; SURGICAL NAVIGATION SYSTEM; WIRELESS COMMUNICATION; ALGORITHM; COMPUTER ASSISTED SURGERY; DEVICES; EQUIPMENT DESIGN; FLUOROSCOPY; HUMAN; MEDICAL ELECTRONICS; ROBOTIC SURGICAL PROCEDURE; STATISTICS AND NUMERICAL DATA; THREE DIMENSIONAL IMAGING; VIBRATION;

EID: 85017556964     PISSN: None     EISSN: 19326203     Source Type: Journal    
DOI: 10.1371/journal.pone.0174407     Document Type: Article
Times cited : (16)

References (20)
  • 3
    • 84873946819 scopus 로고    scopus 로고
    • A novel guiding device for distal locking of intramedullary nails
    • IEEE
    • Lee M-S, Wu S-Y, Wong T-H, Hsu W, Chung T-K, editors. A novel guiding device for distal locking of intramedullary nails. Sensors, 2012 IEEE.
    • (2012) Sensors
    • Lee, M.-S.1    Wu, S.-Y.2    Wong, T.-H.3    Hsu, W.4    Chung, T.-K.5
  • 4
    • 72049110240 scopus 로고    scopus 로고
    • Precision-guided surgical navigation system using laser guidance and 3D autostereoscopic image overlay
    • PMID: 19674871
    • Liao H, Ishihara H, Tran HH, Masamune K, Sakuma I, Dohi T. Precision-guided surgical navigation system using laser guidance and 3D autostereoscopic image overlay. Computerized Medical Imaging and Graphics. 2010; 34(1):46-54. https://doi.org/10.1016/j.compmedimag.2009.07.003 PMID: 19674871
    • (2010) Computerized Medical Imaging and Graphics , vol.34 , Issue.1 , pp. 46-54
    • Liao, H.1    Ishihara, H.2    Tran, H.H.3    Masamune, K.4    Sakuma, I.5    Dohi, T.6
  • 5
    • 68949164911 scopus 로고    scopus 로고
    • Reducing radiation exposure in intra-medullary nailing procedures: Intra-medullary endo-transilluminating (iMET)
    • PMID: 19524231
    • Chu W, Wang J, Young S-T, Chu WC. Reducing radiation exposure in intra-medullary nailing procedures: Intra-medullary endo-transilluminating (iMET). Injury. 2009; 40(10):1084-7. https://doi.org/10.1016/j.injury.2009.04.008 PMID: 19524231
    • (2009) Injury , vol.40 , Issue.10 , pp. 1084-1087
    • Chu, W.1    Wang, J.2    Young, S.-T.3    Chu, W.C.4
  • 7
    • 84939883150 scopus 로고    scopus 로고
    • Fluoroscopy-based laser guidance system for linear surgical tool insertion depth control
    • PMID: 24894992
    • Doke T, Liang JT, Onogi S, Nakajima Y. Fluoroscopy-based laser guidance system for linear surgical tool insertion depth control. International journal of computer assisted radiology and surgery. 2015; 10(3):275-83. https://doi.org/10.1007/s11548-014-1079-8 PMID: 24894992
    • (2015) International Journal of Computer Assisted Radiology and Surgery , vol.10 , Issue.3 , pp. 275-283
    • Doke, T.1    Liang, J.T.2    Onogi, S.3    Nakajima, Y.4
  • 8
  • 9
    • 0025739065 scopus 로고
    • An image intensifier laser guidance system for the distal locking of an intramedullary nail
    • PMID: 1937742
    • Goodall J. An image intensifier laser guidance system for the distal locking of an intramedullary nail. Injury. 1991; 22(4):339. PMID: 1937742
    • (1991) Injury , vol.22 , Issue.4 , pp. 339
    • Goodall, J.1
  • 10
    • 18844386278 scopus 로고    scopus 로고
    • Precise robot-assisted guide positioning for distal locking of intramedullary nails
    • PMID: 15889550
    • Yaniv Z, Joskowicz L. Precise robot-assisted guide positioning for distal locking of intramedullary nails. IEEE transactions on medical imaging. 2005; 24(5):624-35. https://doi.org/10.1109/TMI.2005.844922 PMID: 15889550
    • (2005) IEEE Transactions on Medical Imaging , vol.24 , Issue.5 , pp. 624-635
    • Yaniv, Z.1    Joskowicz, L.2
  • 11
    • 41649094815 scopus 로고    scopus 로고
    • A robust and accurate two-stage approach for automatic recovery of distal locking holes in computer-assisted intramedullary nailing of femoral shaft fractures
    • PMID: 18334439
    • Zheng G, Zhang X, Haschtmann D, Gedet P, Dong X, Nolte L-P. A robust and accurate two-stage approach for automatic recovery of distal locking holes in computer-assisted intramedullary nailing of femoral shaft fractures. IEEE transactions on medical imaging. 2008; 27(2):171-87. https://doi.org/10.1109/TMI.2007.904692 PMID: 18334439
    • (2008) IEEE Transactions on Medical Imaging , vol.27 , Issue.2 , pp. 171-187
    • Zheng, G.1    Zhang, X.2    Haschtmann, D.3    Gedet, P.4    Dong, X.5    Nolte, L.-P.6
  • 13
    • 85024429815 scopus 로고
    • A new approach to linear filtering and prediction problems
    • Kalman RE. A new approach to linear filtering and prediction problems. Journal of basic Engineering. 1960; 82(1):35-45.
    • (1960) Journal of Basic Engineering , vol.82 , Issue.1 , pp. 35-45
    • Kalman, R.E.1
  • 16
    • 33746855962 scopus 로고    scopus 로고
    • Quaternion-based extended Kalman filter for determining orientation by inertial and magnetic sensing
    • PMID: 16830938
    • Sabatini AM. Quaternion-based extended Kalman filter for determining orientation by inertial and magnetic sensing. IEEE Transactions on Biomedical Engineering. 2006; 53(7):1346-56. https://doi.org/10.1109/TBME.2006.875664 PMID: 16830938
    • (2006) IEEE Transactions on Biomedical Engineering , vol.53 , Issue.7 , pp. 1346-1356
    • Sabatini, A.M.1
  • 17
    • 21344442617 scopus 로고    scopus 로고
    • Validation of a real-time wireless telemedicine system, using bluetooth protocol and a mobile phone, for remote monitoring patient in medical practice
    • PMID: 16033715
    • Yousef J, Lars AN. Validation of a real-time wireless telemedicine system, using bluetooth protocol and a mobile phone, for remote monitoring patient in medical practice. Eur J Med Res. 2005; 10(6):254-62 PMID: 16033715
    • (2005) Eur J Med Res , vol.10 , Issue.6 , pp. 254-262
    • Yousef, J.1    Lars, A.N.2
  • 19
    • 54449098074 scopus 로고    scopus 로고
    • A novel technique for distal locking of intramedullary nail based on two non-constrained fluoroscopic images and navigation
    • PMID: 18779062
    • Leloup T, El Kazzi W, Schuind F, Warzée N. A novel technique for distal locking of intramedullary nail based on two non-constrained fluoroscopic images and navigation. IEEE transactions on medical imaging. 2008; 27(9):1202-12. https://doi.org/10.1109/TMI.2008.920602 PMID: 18779062
    • (2008) IEEE Transactions on Medical Imaging , vol.27 , Issue.9 , pp. 1202-1212
    • Leloup, T.1    El Kazzi, W.2    Schuind, F.3    Warzée, N.4
  • 20
    • 84856620528 scopus 로고    scopus 로고
    • Distal locking of femoral nails. Mathematical analysis of the appropriate targeting range
    • Moor B, Ehlinger M, Arlettaz Y. Distal locking of femoral nails. Mathematical analysis of the appropriate targeting range. Orthopaedics & Traumatology: Surgery & Research. 2012; 98(1):85-9.
    • (2012) Orthopaedics & Traumatology: Surgery & Research , vol.98 , Issue.1 , pp. 85-89
    • Moor, B.1    Ehlinger, M.2    Arlettaz, Y.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.