메뉴 건너뛰기




Volumn 10, Issue 3, 2015, Pages 275-283

Fluoroscopy-based laser guidance system for linear surgical tool insertion depth control

Author keywords

Computer aided surgery; Fluoroscopic navigation; Laser guidance system; Percutaneous surgery; Surgical navigation

Indexed keywords

COMPUTER ASSISTED SURGERY; DEVICES; EQUIPMENT DESIGN; FLUOROSCOPY; HUMAN; IMAGE QUALITY; LASER; LOW LEVEL LASER THERAPY;

EID: 84939883150     PISSN: 18616410     EISSN: 18616429     Source Type: Journal    
DOI: 10.1007/s11548-014-1079-8     Document Type: Article
Times cited : (8)

References (27)
  • 1
    • 84947725944 scopus 로고    scopus 로고
    • Towards performing ultrasound-guided needle biopsies from within a head-mounted display
    • Fuchs H, State A, Pisano ED et al (1996) Towards performing ultrasound-guided needle biopsies from within a head-mounted display. Lect Notes Comput Sci 1131:591–600
    • (1996) Lect Notes Comput Sci , vol.1131 , pp. 591-600
    • Fuchs, H.1    State, A.2    Pisano, E.D.3
  • 2
    • 84947754221 scopus 로고    scopus 로고
    • An image overlay system for medical data visualization
    • Blackwell M, Nikou C, DiGioia AM et al (1998) An image overlay system for medical data visualization. Lect Notes Comput Sci 1496:232–240
    • (1998) Lect Notes Comput Sci , vol.1496 , pp. 232-240
    • Blackwell, M.1    Nikou, C.2    DiGioia, A.M.3
  • 3
    • 23844523025 scopus 로고    scopus 로고
    • Image overlay guidance for needle insertion in CT scanner
    • Fichtinger G, Deguet A, Masamune K et al (2005) Image overlay guidance for needle insertion in CT scanner. IEEE Trans Bioemed Eng 52(8):1415–1424
    • (2005) IEEE Trans Bioemed Eng , vol.52 , Issue.8 , pp. 1415-1424
    • Fichtinger, G.1    Deguet, A.2    Masamune, K.3
  • 4
    • 50249109568 scopus 로고    scopus 로고
    • Fusion of laser guidance and 3-d autostereoscopic image overlay for precision-guided surgery
    • Liao H, Ishihara H, Tran HH et al (2008) Fusion of laser guidance and 3-d autostereoscopic image overlay for precision-guided surgery. Lect Notes Comput Sci 5128:367–376
    • (2008) Lect Notes Comput Sci , vol.5128 , pp. 367-376
    • Liao, H.1    Ishihara, H.2    Tran, H.H.3
  • 5
    • 80052666613 scopus 로고    scopus 로고
    • Augmented reality and image overlary navigation with OsiriX in laparoscopic and robotic surgery: not only a matter of fashion
    • PID: 21487758
    • Volonte F, Pugin F, Bucher P et al (2011) Augmented reality and image overlary navigation with OsiriX in laparoscopic and robotic surgery: not only a matter of fashion. J Hepatobiliary Pancreat Sci 18:506–509
    • (2011) J Hepatobiliary Pancreat Sci , vol.18 , pp. 506-509
    • Volonte, F.1    Pugin, F.2    Bucher, P.3
  • 6
    • 0028798212 scopus 로고
    • Stereotactic laser-guided approach to distal middle cerebral artery aneurysms
    • COI: 1:STN:280:DyaK2M3nsVCluw%3D%3D, PID: 7754849
    • Malik JM, Kamiryo T, Goble J et al (1995) Stereotactic laser-guided approach to distal middle cerebral artery aneurysms. Acta Neurochirurgica 132:138–144
    • (1995) Acta Neurochirurgica , vol.132 , pp. 138-144
    • Malik, J.M.1    Kamiryo, T.2    Goble, J.3
  • 8
    • 0032413806 scopus 로고    scopus 로고
    • Frameless laser-guided stereotaxis: a system for CT-monitored neurosurgical interventions
    • COI: 1:STN:280:DyaK1M7ovFemsA%3D%3D
    • Hussman KL, Chalouplca JC, Berger SB (1998) Frameless laser-guided stereotaxis: a system for CT-monitored neurosurgical interventions. Stereotect Funct Neurosurg 71:62–75
    • (1998) Stereotect Funct Neurosurg , vol.71 , pp. 62-75
    • Hussman, K.L.1    Chalouplca, J.C.2    Berger, S.B.3
  • 9
    • 0345686737 scopus 로고    scopus 로고
    • Laser projection augumented reality system for computer assited surgery
    • Glossop N, Wedlake C, Moore J et al (2002) Laser projection augumented reality system for computer assited surgery. Lect Notes Comput Sci 2879:239–246
    • (2002) Lect Notes Comput Sci , vol.2879 , pp. 239-246
    • Glossop, N.1    Wedlake, C.2    Moore, J.3
  • 10
    • 33645745111 scopus 로고    scopus 로고
    • Image-guided laser projection for port placement in minimally invasive surgery
    • PID: 16404080
    • Marmurek J, Wedlake C, Pardasani U et al (2006) Image-guided laser projection for port placement in minimally invasive surgery. Stud Health Technol Inform 119:367–372
    • (2006) Stud Health Technol Inform , vol.119 , pp. 367-372
    • Marmurek, J.1    Wedlake, C.2    Pardasani, U.3
  • 11
    • 34447630651 scopus 로고    scopus 로고
    • Laser-guided computed tomography puncture system: simulation experiments using artificial phantom lesions and preliminary clinical experience
    • PID: 17514371
    • Nitta N, Takahashi M, Tanaka T et al (2007) Laser-guided computed tomography puncture system: simulation experiments using artificial phantom lesions and preliminary clinical experience. Radiat Med 25(4):187–193
    • (2007) Radiat Med , vol.25 , Issue.4 , pp. 187-193
    • Nitta, N.1    Takahashi, M.2    Tanaka, T.3
  • 12
    • 84944050357 scopus 로고    scopus 로고
    • A novel laser guidance system for alignment of linear surgical tools: its principles and performance evaluation as a man–machine system medical image computing and computer-assisted intervention—MICCAI 2002. In: Dohi T, Kikinis R (eds) vol 2489. Lecture notes in computer science. Springer, Berlin, pp 25–132
    • Sasama T, Sugano N, Sato Y, Momoi Y, Koyama T, Nakajima Y, Sakuma I, Fujie M, Yonenobu K, Ochi T, Tamura S (2002) A novel laser guidance system for alignment of linear surgical tools: its principles and performance evaluation as a man–machine system medical image computing and computer-assisted intervention—MICCAI 2002. In: Dohi T, Kikinis R (eds) vol 2489. Lecture notes in computer science. Springer, Berlin, pp 25–132. doi:10.1007/3-540-45787-9_16
    • (2002) doi:10.1007/3-540-45787-9_16
    • Sasama, T.1    Sugano, N.2    Sato, Y.3    Momoi, Y.4    Koyama, T.5    Nakajima, Y.6    Sakuma, I.7    Fujie, M.8    Yonenobu, K.9    Ochi, T.10    Tamura, S.11
  • 15
    • 0034655412 scopus 로고    scopus 로고
    • Com-plications of pedicle screw fixation in reconstructive surgery of the cervicalspine
    • COI: 1:STN:280:DC%2BD3c3jt1Sgtw%3D%3D, PID: 10767809
    • Abumi K, Shono Y, Ito M, Taneichi H, Kotani Y, Kaneda K (2000) Com-plications of pedicle screw fixation in reconstructive surgery of the cervicalspine. Spine 25:962–969
    • (2000) Spine , vol.25 , pp. 962-969
    • Abumi, K.1    Shono, Y.2    Ito, M.3    Taneichi, H.4    Kotani, Y.5    Kaneda, K.6
  • 16
    • 0038638437 scopus 로고    scopus 로고
    • Temperature measurement during polymerization of polymethylmethacrylate cement used for vertebroplasty
    • PID: 12865844
    • Belkoff S, Molloy S (2003) Temperature measurement during polymerization of polymethylmethacrylate cement used for vertebroplasty. Spine 28:1555–1559
    • (2003) Spine , vol.28 , pp. 1555-1559
    • Belkoff, S.1    Molloy, S.2
  • 17
    • 84865738069 scopus 로고    scopus 로고
    • Evaluation of a portable image overlay projector for the visualization of surgical navigation data: phantom studies
    • COI: 1:STN:280:DC%2BC38zms1yrsA%3D%3D
    • Gavaghan K, Oliveira-Santos T, Peterhans M, Reyes M, Kim H, Anderegg S, Weber S (2012) Evaluation of a portable image overlay projector for the visualization of surgical navigation data: phantom studies. Int J Comp Assis Radio Surg 7:547–556
    • (2012) Int J Comp Assis Radio Surg , vol.7 , pp. 547-556
    • Gavaghan, K.1    Oliveira-Santos, T.2    Peterhans, M.3    Reyes, M.4    Kim, H.5    Anderegg, S.6    Weber, S.7
  • 19
    • 0032822724 scopus 로고    scopus 로고
    • Fluoroscopy as an imaging means for computer-assisted surgical navigation
    • COI: 1:STN:280:DyaK1MvisFequw%3D%3D
    • Hofstetter R, Slomczykowski M, Sati M, Nolte L (1999) Fluoroscopy as an imaging means for computer-assisted surgical navigation. Comp Assis Surg 4:65–76
    • (1999) Comp Assis Surg , vol.4 , pp. 65-76
    • Hofstetter, R.1    Slomczykowski, M.2    Sati, M.3    Nolte, L.4
  • 22
    • 0036747233 scopus 로고    scopus 로고
    • Technique of microendoscopy in medial lumbar disc herniation
    • Schick U, Dohnert J (2002) Technique of microendoscopy in medial lumbar disc herniation. Minim Invasive Neurosurg 45:139–141
    • (2002) Minim Invasive Neurosurg , vol.45 , pp. 139-141
    • Schick, U.1    Dohnert, J.2
  • 23
    • 0035708541 scopus 로고    scopus 로고
    • Clinical results of percutaneous pelvic surgery. Computer assisted surgery using ultrasound compared to standard fluoroscopy
    • COI: 1:STN:280:DC%2BD387gtlKqug%3D%3D
    • Tonetti J, Carrat L, Blendea S, Merloz P, Troccaz J, Lavallee S, Chirossel J (2001) Clinical results of percutaneous pelvic surgery. Computer assisted surgery using ultrasound compared to standard fluoroscopy. Comp Aided Surg 6:204–211
    • (2001) Comp Aided Surg , vol.6 , pp. 204-211
    • Tonetti, J.1    Carrat, L.2    Blendea, S.3    Merloz, P.4    Troccaz, J.5    Lavallee, S.6    Chirossel, J.7
  • 26
    • 84957077730 scopus 로고    scopus 로고
    • Camera-augmented mobile c-arm (camc) application: 3d reconstruction using a low-cost mobile c-arm. In: Lecture notes in computer science, vol 1679. MICCAI’99
    • Navab N, Mitschke M, Schutz O (1999), Camera-augmented mobile c-arm (camc) application: 3d reconstruction using a low-cost mobile c-arm. In: Lecture notes in computer science, vol 1679. MICCAI’99, pp 688–697
    • (1999) pp 688–697
    • Navab, N.1    Mitschke, M.2    Schutz, O.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.