Volumn 36, Issue , 2016, Pages 246-251

Inferior vena cava diameter variation compared with pulse pressure variation as predictors of fluid responsiveness in patients with sepsis

Author keywords

Inferior vena cava diameter fluid; Inferior vena cava diameter ultrasound; Pulse pressure variation; Sepsis; Septic shock

Indexed keywords

ADULT; ARTICLE; BLOOD VESSEL PARAMETERS; CLINICAL ARTICLE; CONTROLLED STUDY; FEMALE; GOLD STANDARD; HEART OUTPUT; HEMODYNAMICS; HUMAN; INFERIOR VENA CAVA DIAMETER VARIATION; INTERMETHOD COMPARISON; MALE; MEDICAL PARAMETERS; OBSERVATIONAL STUDY; PREDICTION; PROSPECTIVE STUDY; PULSE PRESSURE; SENSITIVITY AND SPECIFICITY; SEPSIS; STROKE VOLUME VARIATIONN; AGED; BLOOD PRESSURE; DIAGNOSTIC IMAGING; ECHOCARDIOGRAPHY; FLUID THERAPY; HEART STROKE VOLUME; INFERIOR CAVA VEIN; MIDDLE AGED; ORGAN SIZE; PATHOLOGY; PATHOPHYSIOLOGY; PREDICTIVE VALUE; PROGNOSIS; RECEIVER OPERATING CHARACTERISTIC; SHOCK, SEPTIC; VERY ELDERLY;

EID: 84995578375     PISSN: 08839441     EISSN: 15578615     Source Type: Journal    
DOI: 10.1016/j.jcrc.2016.07.023     Document Type: Article
Times cited : (38)

References (43)
  • 1
    • 0035829842 scopus 로고    scopus 로고
    • Early goal-directed therapy in the treatment of severe sepsis and septic shock
    • [1] Rivers, E, Nguyen, B, Havstad, S, Ressler, J, Muzzin, A, Knoblich, B, et al. Early goal-directed therapy in the treatment of severe sepsis and septic shock. N Engl J Med 345:19 (2001), 1368–1377.
    • (2001) N Engl J Med , vol.345 , Issue.19 , pp. 1368-1377
    • Rivers, E.1    Nguyen, B.2    Havstad, S.3    Ressler, J.4    Muzzin, A.5    Knoblich, B.6
  • 2
    • 84873339299 scopus 로고    scopus 로고
    • Surviving sepsis campaign: international guidelines for management of severe sepsis and septic shock: 2012
    • [2] Dellinger, RP, Levy, MM, Rhodes, A, Annane, D, Gerlach, H, Opal, SM, et al. Surviving sepsis campaign: international guidelines for management of severe sepsis and septic shock: 2012. Crit Care Med 41:2 (2013), 580–637.
    • (2013) Crit Care Med , vol.41 , Issue.2 , pp. 580-637
    • Dellinger, R.P.1    Levy, M.M.2    Rhodes, A.3    Annane, D.4    Gerlach, H.5    Opal, S.M.6
  • 3
    • 0033924592 scopus 로고    scopus 로고
    • Relation between respiratory changes in arterial pulse pressure and fluid responsiveness in septic patients with acute circulatory failure
    • [3] Michard, F, Boussat, S, Chemla, D, Anguel, N, Mercat, A, Lecarpentier, Y, et al. Relation between respiratory changes in arterial pulse pressure and fluid responsiveness in septic patients with acute circulatory failure. Am J Respir Crit Care Med 162:1 (2000), 134–138.
    • (2000) Am J Respir Crit Care Med , vol.162 , Issue.1 , pp. 134-138
    • Michard, F.1    Boussat, S.2    Chemla, D.3    Anguel, N.4    Mercat, A.5    Lecarpentier, Y.6
  • 4
    • 0035092478 scopus 로고    scopus 로고
    • Respiratory changes in aortic blood velocity as an indicator of fluid responsiveness in ventilated patients with septic shock
    • [4] Feissel, M, Michard, F, Mangin, I, Ruyer, O, Faller, JP, Teboul, JL, Respiratory changes in aortic blood velocity as an indicator of fluid responsiveness in ventilated patients with septic shock. Chest 119:3 (2001), 867–873.
    • (2001) Chest , vol.119 , Issue.3 , pp. 867-873
    • Feissel, M.1    Michard, F.2    Mangin, I.3    Ruyer, O.4    Faller, J.P.5    Teboul, J.L.6
  • 5
    • 0032437998 scopus 로고    scopus 로고
    • Systolic pressure variation as a guide to fluid therapy in patients with sepsis-induced hypotension
    • [5] Tavernier, B, Makhotine, O, Lebuffe, G, Dupont, J, Scherpereel, P, Systolic pressure variation as a guide to fluid therapy in patients with sepsis-induced hypotension. Anesthesiology 89:6 (1998), 1313–1321.
    • (1998) Anesthesiology , vol.89 , Issue.6 , pp. 1313-1321
    • Tavernier, B.1    Makhotine, O.2    Lebuffe, G.3    Dupont, J.4    Scherpereel, P.5
  • 6
    • 0842284105 scopus 로고    scopus 로고
    • Assessing fluid responsiveness by stroke volume variation in mechanically ventilated patients with severe sepsis
    • [6] Marx, G, Cope, T, McCrossan, L, Swaraj, S, Cowan, C, Mostafa, SM, et al. Assessing fluid responsiveness by stroke volume variation in mechanically ventilated patients with severe sepsis. Eur J Anaesthesiol 21:2 (2004), 132–138.
    • (2004) Eur J Anaesthesiol , vol.21 , Issue.2 , pp. 132-138
    • Marx, G.1    Cope, T.2    McCrossan, L.3    Swaraj, S.4    Cowan, C.5    Mostafa, S.M.6
  • 7
    • 4644223327 scopus 로고    scopus 로고
    • Superior vena caval collapsibility as a gauge of volume status in ventilated septic patients
    • [7] Vieillard-Baron, A, Chergui, K, Rabiller, A, Peyrouset, O, Page, B, Beauchet, A, et al. Superior vena caval collapsibility as a gauge of volume status in ventilated septic patients. Intensive Care Med 30:9 (2004), 1734–1739.
    • (2004) Intensive Care Med , vol.30 , Issue.9 , pp. 1734-1739
    • Vieillard-Baron, A.1    Chergui, K.2    Rabiller, A.3    Peyrouset, O.4    Page, B.5    Beauchet, A.6
  • 8
    • 2542457136 scopus 로고    scopus 로고
    • The respiratory variation in inferior vena cava diameter as a guide to fluid therapy
    • [8] Feissel, M, Michard, F, Faller, JP, Teboul, JL, The respiratory variation in inferior vena cava diameter as a guide to fluid therapy. Intensive Care Med 30:9 (2004), 1834–1837.
    • (2004) Intensive Care Med , vol.30 , Issue.9 , pp. 1834-1837
    • Feissel, M.1    Michard, F.2    Faller, J.P.3    Teboul, J.L.4
  • 9
    • 4644226589 scopus 로고    scopus 로고
    • Respiratory changes in inferior vena cava diameter are helpful in predicting fluid responsiveness in ventilated septic patients
    • [9] Barbier, C, Loubieres, Y, Schmit, C, Hayon, J, Ricome, JL, Jardin, F, et al. Respiratory changes in inferior vena cava diameter are helpful in predicting fluid responsiveness in ventilated septic patients. Intensive Care Med 30:9 (2004), 1740–1746.
    • (2004) Intensive Care Med , vol.30 , Issue.9 , pp. 1740-1746
    • Barbier, C.1    Loubieres, Y.2    Schmit, C.3    Hayon, J.4    Ricome, J.L.5    Jardin, F.6
  • 10
    • 34247143973 scopus 로고    scopus 로고
    • Plethysmographic dynamic indices predict fluid responsiveness in septic ventilated patients
    • [10] Feissel, M, Teboul, JL, Merlani, P, Badie, J, Faller, JP, Bendjelid, K, Plethysmographic dynamic indices predict fluid responsiveness in septic ventilated patients. Intensive Care Med 33:6 (2007), 993–999.
    • (2007) Intensive Care Med , vol.33 , Issue.6 , pp. 993-999
    • Feissel, M.1    Teboul, J.L.2    Merlani, P.3    Badie, J.4    Faller, J.P.5    Bendjelid, K.6
  • 11
    • 0036283553 scopus 로고    scopus 로고
    • Predicting fluid responsiveness in ICU patients: a critical analysis of the evidence
    • [11] Michard, F, Teboul, JL, Predicting fluid responsiveness in ICU patients: a critical analysis of the evidence. Chest 121:6 (2002), 2000–2008.
    • (2002) Chest , vol.121 , Issue.6 , pp. 2000-2008
    • Michard, F.1    Teboul, J.L.2
  • 12
    • 0032988086 scopus 로고    scopus 로고
    • Clinical use of respiratory changes in arterial pulse pressure to monitor the hemodynamic effects of PEEP
    • [12] Michard, F, Chemla, D, Richard, C, Wysocki, M, Pinsky, MR, Lecarpentier, Y, et al. Clinical use of respiratory changes in arterial pulse pressure to monitor the hemodynamic effects of PEEP. Am J Respir Crit Care Med 159:3 (1999), 935–939.
    • (1999) Am J Respir Crit Care Med , vol.159 , Issue.3 , pp. 935-939
    • Michard, F.1    Chemla, D.2    Richard, C.3    Wysocki, M.4    Pinsky, M.R.5    Lecarpentier, Y.6
  • 13
    • 17444414557 scopus 로고    scopus 로고
    • Pulse pressure variations to predict fluid responsiveness: influence of tidal volume
    • [13] De Backer, D, Heenen, S, Piagnerelli, M, Koch, M, Vincent, JL, Pulse pressure variations to predict fluid responsiveness: influence of tidal volume. Intensive Care Med 31:4 (2005), 517–523.
    • (2005) Intensive Care Med , vol.31 , Issue.4 , pp. 517-523
    • De Backer, D.1    Heenen, S.2    Piagnerelli, M.3    Koch, M.4    Vincent, J.L.5
  • 14
    • 23744504093 scopus 로고    scopus 로고
    • Stroke volume and pulse pressure variation for prediction of fluid responsiveness in patients undergoing off-pump coronary artery bypass grafting
    • [14] Hofer, CK, Muller, SM, Furrer, L, Klaghofer, R, Genoni, M, Zollinger, A, Stroke volume and pulse pressure variation for prediction of fluid responsiveness in patients undergoing off-pump coronary artery bypass grafting. Chest 128:2 (2005), 848–854.
    • (2005) Chest , vol.128 , Issue.2 , pp. 848-854
    • Hofer, C.K.1    Muller, S.M.2    Furrer, L.3    Klaghofer, R.4    Genoni, M.5    Zollinger, A.6
  • 15
    • 24744434154 scopus 로고    scopus 로고
    • Assessment of fluid responsiveness in mechanically ventilated cardiac surgical patients
    • [15] Wiesenack, C, Fiegl, C, Keyser, A, Prasser, C, Keyl, C, Assessment of fluid responsiveness in mechanically ventilated cardiac surgical patients. Eur J Anaesthesiol 22:9 (2005), 658–665.
    • (2005) Eur J Anaesthesiol , vol.22 , Issue.9 , pp. 658-665
    • Wiesenack, C.1    Fiegl, C.2    Keyser, A.3    Prasser, C.4    Keyl, C.5
  • 16
    • 27944432971 scopus 로고    scopus 로고
    • Pre-ejection period variations predict the fluid responsiveness of septic ventilated patients
    • [16] Feissel, M, Badie, J, Merlani, PG, Faller, JP, Bendjelid, K, Pre-ejection period variations predict the fluid responsiveness of septic ventilated patients. Crit Care Med 33:11 (2005), 2534–2539.
    • (2005) Crit Care Med , vol.33 , Issue.11 , pp. 2534-2539
    • Feissel, M.1    Badie, J.2    Merlani, P.G.3    Faller, J.P.4    Bendjelid, K.5
  • 17
    • 41349122492 scopus 로고    scopus 로고
    • The ability of a novel algorithm for automatic estimation of the respiratory variations in arterial pulse pressure to monitor fluid responsiveness in the operating room
    • [table of contents]
    • [17] Cannesson, M, Slieker, J, Desebbe, O, Bauer, C, Chiari, P, Henaine, R, et al. The ability of a novel algorithm for automatic estimation of the respiratory variations in arterial pulse pressure to monitor fluid responsiveness in the operating room. Anesth Analg 106:4 (2008), 1195–1200 [table of contents].
    • (2008) Anesth Analg , vol.106 , Issue.4 , pp. 1195-1200
    • Cannesson, M.1    Slieker, J.2    Desebbe, O.3    Bauer, C.4    Chiari, P.5    Henaine, R.6
  • 18
    • 69349089330 scopus 로고    scopus 로고
    • Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: a systematic review of the literature
    • [18] Marik, PE, Cavallazzi, R, Vasu, T, Hirani, A, Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: a systematic review of the literature. Crit Care Med 37:9 (2009), 2642–2647.
    • (2009) Crit Care Med , vol.37 , Issue.9 , pp. 2642-2647
    • Marik, P.E.1    Cavallazzi, R.2    Vasu, T.3    Hirani, A.4
  • 19
    • 71749103572 scopus 로고    scopus 로고
    • Automated pulse pressure and stroke volume variations from radial artery: evaluation during major abdominal surgery
    • [19] Derichard, A, Robin, E, Tavernier, B, Costecalde, M, Fleyfel, M, Onimus, J, et al. Automated pulse pressure and stroke volume variations from radial artery: evaluation during major abdominal surgery. Br J Anaesth 103:5 (2009), 678–684.
    • (2009) Br J Anaesth , vol.103 , Issue.5 , pp. 678-684
    • Derichard, A.1    Robin, E.2    Tavernier, B.3    Costecalde, M.4    Fleyfel, M.5    Onimus, J.6
  • 20
    • 79953827557 scopus 로고    scopus 로고
    • Arterial pressure-based cardiac output monitoring: a multicenter validation of the third-generation software in septic patients
    • [20] De Backer, D, Marx, G, Tan, A, Junker, C, Van Nuffelen, M, Huter, L, et al. Arterial pressure-based cardiac output monitoring: a multicenter validation of the third-generation software in septic patients. Intensive Care Med 37:2 (2011), 233–240.
    • (2011) Intensive Care Med , vol.37 , Issue.2 , pp. 233-240
    • De Backer, D.1    Marx, G.2    Tan, A.3    Junker, C.4    Van Nuffelen, M.5    Huter, L.6
  • 21
    • 84856769201 scopus 로고    scopus 로고
    • Prediction of fluid responsiveness in septic shock patients: comparing stroke volume variation by FloTrac/Vigileo and automated pulse pressure variation
    • [21] Khwannimit, B, Bhurayanontachai, R, Prediction of fluid responsiveness in septic shock patients: comparing stroke volume variation by FloTrac/Vigileo and automated pulse pressure variation. Eur J Anaesthesiol 29:2 (2012), 64–69.
    • (2012) Eur J Anaesthesiol , vol.29 , Issue.2 , pp. 64-69
    • Khwannimit, B.1    Bhurayanontachai, R.2
  • 22
    • 0141613115 scopus 로고    scopus 로고
    • Stroke volume variations
    • [22] De Backer, D, Stroke volume variations. Minerva Anestesiol 69:4 (2003), 285–288.
    • (2003) Minerva Anestesiol , vol.69 , Issue.4 , pp. 285-288
    • De Backer, D.1
  • 23
    • 56449113016 scopus 로고    scopus 로고
    • Uncalibrated pulse contour-derived stroke volume variation predicts fluid responsiveness in mechanically ventilated patients undergoing liver transplantation
    • [23] Biais, M, Nouette-Gaulain, K, Cottenceau, V, Revel, P, Sztark, F, Uncalibrated pulse contour-derived stroke volume variation predicts fluid responsiveness in mechanically ventilated patients undergoing liver transplantation. Br J Anaesth 101:6 (2008), 761–768.
    • (2008) Br J Anaesth , vol.101 , Issue.6 , pp. 761-768
    • Biais, M.1    Nouette-Gaulain, K.2    Cottenceau, V.3    Revel, P.4    Sztark, F.5
  • 24
    • 47149111264 scopus 로고    scopus 로고
    • Assessment of stroke volume variation for prediction of fluid responsiveness using the modified FloTrac and PiCCOplus system
    • [24] Hofer, CK, Senn, A, Weibel, L, Zollinger, A, Assessment of stroke volume variation for prediction of fluid responsiveness using the modified FloTrac and PiCCOplus system. Crit Care, 12(3), 2008, R82.
    • (2008) Crit Care , vol.12 , Issue.3 , pp. R82
    • Hofer, C.K.1    Senn, A.2    Weibel, L.3    Zollinger, A.4
  • 25
    • 59649123027 scopus 로고    scopus 로고
    • The ability of stroke volume variations obtained with Vigileo/FloTrac system to monitor fluid responsiveness in mechanically ventilated patients
    • [25] Cannesson, M, Musard, H, Desebbe, O, Boucau, C, Simon, R, Henaine, R, et al. The ability of stroke volume variations obtained with Vigileo/FloTrac system to monitor fluid responsiveness in mechanically ventilated patients. Anesth Analg 108:2 (2009), 513–517.
    • (2009) Anesth Analg , vol.108 , Issue.2 , pp. 513-517
    • Cannesson, M.1    Musard, H.2    Desebbe, O.3    Boucau, C.4    Simon, R.5    Henaine, R.6
  • 26
    • 77949403336 scopus 로고    scopus 로고
    • Abilities of pulse pressure variations and stroke volume variations to predict fluid responsiveness in prone position during scoliosis surgery
    • [26] Biais, M, Bernard, O, Ha, JC, Degryse, C, Sztark, F, Abilities of pulse pressure variations and stroke volume variations to predict fluid responsiveness in prone position during scoliosis surgery. Br J Anaesth 104:4 (2010), 407–413.
    • (2010) Br J Anaesth , vol.104 , Issue.4 , pp. 407-413
    • Biais, M.1    Bernard, O.2    Ha, J.C.3    Degryse, C.4    Sztark, F.5
  • 27
    • 0036137453 scopus 로고    scopus 로고
    • Kilger E, Schmidt C, Lamm P, Goetz AE. Optimizing fluid therapy in mechanically ventilated patients after cardiac surgery by on-line monitoring of left ventricular stroke volume variations. Comparison with aortic systolic pressure variations
    • [27] Reuter, DA, Felbinger, TW, Kilger E, Schmidt C, Lamm P, Goetz AE. Optimizing fluid therapy in mechanically ventilated patients after cardiac surgery by on-line monitoring of left ventricular stroke volume variations. Comparison with aortic systolic pressure variations. Br J Anaesth 88:1 (2002), 124–126.
    • (2002) Br J Anaesth , vol.88 , Issue.1 , pp. 124-126
    • Reuter, D.A.1    Felbinger, T.W.2
  • 28
    • 33845650245 scopus 로고    scopus 로고
    • Arterial versus plethysmographic dynamic indices to test responsiveness for testing fluid administration in hypotensive patients: a clinical trial
    • [28] Natalini, G, Rosano, A, Taranto, M, Faggian, B, Vittorielli, E, Bernardini, A, Arterial versus plethysmographic dynamic indices to test responsiveness for testing fluid administration in hypotensive patients: a clinical trial. Anesth Analg 103:6 (2006), 1478–1484.
    • (2006) Anesth Analg , vol.103 , Issue.6 , pp. 1478-1484
    • Natalini, G.1    Rosano, A.2    Taranto, M.3    Faggian, B.4    Vittorielli, E.5    Bernardini, A.6
  • 29
    • 0033966058 scopus 로고    scopus 로고
    • The use of transesophageal echocardiography for preload assessment in critically ill patients
    • [29] Tousignant, CP, Walsh, F, Mazer, CD, The use of transesophageal echocardiography for preload assessment in critically ill patients. Anesth Analg 90:2 (2000), 351–355.
    • (2000) Anesth Analg , vol.90 , Issue.2 , pp. 351-355
    • Tousignant, C.P.1    Walsh, F.2    Mazer, C.D.3
  • 30
    • 77949394030 scopus 로고    scopus 로고
    • Brachial artery peak velocity variation to predict fluid responsiveness in mechanically ventilated patients
    • [30] Monge Garcia, MI, Gil Cano, A, Diaz Monrove, JC, Brachial artery peak velocity variation to predict fluid responsiveness in mechanically ventilated patients. Crit Care, 13(5), 2009, R142.
    • (2009) Crit Care , vol.13 , Issue.5 , pp. R142
    • Monge Garcia, M.I.1    Gil Cano, A.2    Diaz Monrove, J.C.3
  • 31
    • 3843116717 scopus 로고    scopus 로고
    • Arterial cannulation: a critical review
    • [31] Cousins, TR, O'Donnell, JM, Arterial cannulation: a critical review. AANA J 72:4 (2004), 267–271.
    • (2004) AANA J , vol.72 , Issue.4 , pp. 267-271
    • Cousins, T.R.1    O'Donnell, J.M.2
  • 33
    • 33749058841 scopus 로고    scopus 로고
    • Handcarried ultrasound measurement of the inferior vena cava for assessment of intravascular volume status in the outpatient hemodialysis clinic
    • [33] Brennan, JM, Ronan, A, Goonewardena, S, Blair, JE, Hammes, M, Shah, D, et al. Handcarried ultrasound measurement of the inferior vena cava for assessment of intravascular volume status in the outpatient hemodialysis clinic. Clin J Am Soc Nephrol 1:4 (2006), 749–753.
    • (2006) Clin J Am Soc Nephrol , vol.1 , Issue.4 , pp. 749-753
    • Brennan, J.M.1    Ronan, A.2    Goonewardena, S.3    Blair, J.E.4    Hammes, M.5    Shah, D.6
  • 34
    • 33846669409 scopus 로고    scopus 로고
    • Cardiac output determination from the arterial pressure wave: clinical testing of a novel algorithm that does not require calibration
    • [34] Manecke, GR Jr., Auger, WR, Cardiac output determination from the arterial pressure wave: clinical testing of a novel algorithm that does not require calibration. J Cardiothorac Vasc Anesth 21:1 (2007), 3–7.
    • (2007) J Cardiothorac Vasc Anesth , vol.21 , Issue.1 , pp. 3-7
    • Manecke, G.R.1    Auger, W.R.2
  • 35
    • 0037396875 scopus 로고    scopus 로고
    • 2001 SCCM/ESICM/ACCP/ATS/SIS International Sepsis Definitions Conference
    • [35] Levy, MM, Fink, MP, Marshall, JC, Abraham, E, Angus, D, Cook, D, et al. 2001 SCCM/ESICM/ACCP/ATS/SIS International Sepsis Definitions Conference. Intensive Care Med 29:4 (2003), 530–538.
    • (2003) Intensive Care Med , vol.29 , Issue.4 , pp. 530-538
    • Levy, M.M.1    Fink, M.P.2    Marshall, J.C.3    Abraham, E.4    Angus, D.5    Cook, D.6
  • 36
    • 33646567765 scopus 로고    scopus 로고
    • Fluid challenge revisited
    • [36] Vincent, JL, Weil, MH, Fluid challenge revisited. Crit Care Med 34:5 (2006), 1333–1337.
    • (2006) Crit Care Med , vol.34 , Issue.5 , pp. 1333-1337
    • Vincent, J.L.1    Weil, M.H.2
  • 37
    • 54549110342 scopus 로고    scopus 로고
    • Effect of tidal volume, sampling duration, and cardiac contractility on pulse pressure and stroke volume variation during positive-pressure ventilation
    • [37] Kim, HK, Pinsky, MR, Effect of tidal volume, sampling duration, and cardiac contractility on pulse pressure and stroke volume variation during positive-pressure ventilation. Crit Care Med 36:10 (2008), 2858–2862.
    • (2008) Crit Care Med , vol.36 , Issue.10 , pp. 2858-2862
    • Kim, H.K.1    Pinsky, M.R.2
  • 38
    • 79957656409 scopus 로고    scopus 로고
    • Arterial pressure allows monitoring the changes in cardiac output induced by volume expansion but not by norepinephrine
    • [38] Monnet, X, Letierce, A, Hamzaoui, O, Chemla, D, Anguel, N, Osman, D, et al. Arterial pressure allows monitoring the changes in cardiac output induced by volume expansion but not by norepinephrine. Crit Care Med 39:6 (2011), 1394–1399.
    • (2011) Crit Care Med , vol.39 , Issue.6 , pp. 1394-1399
    • Monnet, X.1    Letierce, A.2    Hamzaoui, O.3    Chemla, D.4    Anguel, N.5    Osman, D.6
  • 39
    • 62849122288 scopus 로고    scopus 로고
    • Predicting volume responsiveness by using the end-expiratory occlusion in mechanically ventilated intensive care unit patients
    • [39] Monnet, X, Osman, D, Ridel, C, Lamia, B, Richard, C, Teboul, JL, Predicting volume responsiveness by using the end-expiratory occlusion in mechanically ventilated intensive care unit patients. Crit Care Med 37:3 (2009), 951–956.
    • (2009) Crit Care Med , vol.37 , Issue.3 , pp. 951-956
    • Monnet, X.1    Osman, D.2    Ridel, C.3    Lamia, B.4    Richard, C.5    Teboul, J.L.6
  • 40
    • 34548453111 scopus 로고    scopus 로고
    • Volume responsiveness
    • [40] Monnet, X, Teboul, JL, Volume responsiveness. Curr Opin Crit Care 13:5 (2007), 549–553.
    • (2007) Curr Opin Crit Care , vol.13 , Issue.5 , pp. 549-553
    • Monnet, X.1    Teboul, J.L.2
  • 41
    • 84914820849 scopus 로고    scopus 로고
    • Incidence and prognosis of intra-abdominal hypertension in critically ill medical patients: a prospective epidemiological study
    • [41] Santa-Teresa, P, Munoz, J, Montero, I, Zurita, M, Tomey, M, Alvarez-Sala, L, et al. Incidence and prognosis of intra-abdominal hypertension in critically ill medical patients: a prospective epidemiological study. Ann Intensive Care, 2(Suppl. 1), 2012, S3.
    • (2012) Ann Intensive Care , vol.2 , pp. S3
    • Santa-Teresa, P.1    Munoz, J.2    Montero, I.3    Zurita, M.4    Tomey, M.5    Alvarez-Sala, L.6
  • 42
    • 36649016883 scopus 로고    scopus 로고
    • Abdominal compartment syndrome is common in medical intensive care unit patients receiving large-volume resuscitation
    • [42] Daugherty, EL, Hongyan, L, Taichman, D, Hansen-Flaschen, J, Fuchs, BD, Abdominal compartment syndrome is common in medical intensive care unit patients receiving large-volume resuscitation. J Intensive Care Med 22:5 (2007), 294–299.
    • (2007) J Intensive Care Med , vol.22 , Issue.5 , pp. 294-299
    • Daugherty, E.L.1    Hongyan, L.2    Taichman, D.3    Hansen-Flaschen, J.4    Fuchs, B.D.5
  • 43
    • 0034064274 scopus 로고    scopus 로고
    • Narrowing of the upper abdominal inferior vena cava in patients with elevated intraabdominal pressure: sonographic observations
    • [43] Wachsberg, RH, Narrowing of the upper abdominal inferior vena cava in patients with elevated intraabdominal pressure: sonographic observations. J Ultrasound Med 19:3 (2000), 217–222.
    • (2000) J Ultrasound Med , vol.19 , Issue.3 , pp. 217-222
    • Wachsberg, R.H.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.