Prediction of fluid responsiveness in septic shock patients: Comparing stroke volume variation by FloTrac/Vigileo and automated pulse pressure variation

Author keywords

Cardiac output; Fluid; Monitoring; Septic shock; Stroke volume

Indexed keywords

DOPAMINE; HETASTARCH; MIDAZOLAM; MORPHINE; NORADRENALIN; VECURONIUM;

EID: 84856769201     PISSN: 02650215     EISSN: 13652346     Source Type: Journal    
DOI: 10.1097/EJA.0b013e32834b7d82     Document Type: Article
Times cited : (60)

References (36)
  • 1
    • 0035829842 scopus 로고    scopus 로고
    • Early goal-directed therapy in the treatment of severe sepsis and septic shock
    • Rivers E, Nguyen B, Havstad S, et al. Early goal-directed therapy in the treatment of severe sepsis and septic shock. N Engl J Med 2001; 345:1368-1377.
    • (2001) N Engl J Med , vol.345 , pp. 1368-1377
    • Rivers, E.1    Nguyen, B.2    Havstad, S.3
  • 2
    • 0032437998 scopus 로고    scopus 로고
    • Systolic pressure variation as a guide to fluid therapy in patients with sepsis-induced hypotension
    • DOI 10.1097/00000542-199812000-00007
    • Tavernier B, Makhotine O, Lebuffe G, et al. Systolic pressure variation as a guide to fluid therapy in patients with sepsis-induced hypotension. Anesthesiology 1998; 89:1313-1321. (Pubitemid 29001568)
    • (1998) Anesthesiology , vol.89 , Issue.6 , pp. 1313-1321
    • Tavernier, B.1    Makhotine, O.2    Lebuffe, G.3    Dupont, J.4    Scherpereel, P.5
  • 4
    • 0035092478 scopus 로고    scopus 로고
    • Respiratory changes in aortic blood velocity as an indicator of fluid responsiveness in ventilated patients with septic shock
    • DOI 10.1378/chest.119.3.867
    • Feissel M, Michard F, Mangin I, et al. Respiratory changes in aortic blood velocity as an indicator of fluid responsiveness in ventilated patients with septic shock. Chest 2001; 119:867-873. (Pubitemid 32197661)
    • (2001) Chest , vol.119 , Issue.3 , pp. 867-873
    • Feissel, M.1    Michard, F.2    Mangin, I.3    Ruyer, O.4    Faller, J.-P.5    Teboul, J.-L.6
  • 7
    • 4644226589 scopus 로고    scopus 로고
    • Respiratory changes in inferior vena cava diameter are helpful in predicting fluid responsiveness in ventilated septic patients
    • DOI 10.1007/s00134-004-2259-8
    • Barbier C, Loubieres Y, Schmit C, et al. Respiratory changes in inferior vena cava diameter are helpful in predicting fluid responsiveness in ventilated septic patients. Intensive Care Med 2004; 30:1740-1746. (Pubitemid 39297177)
    • (2004) Intensive Care Medicine , vol.30 , Issue.9 , pp. 1740-1746
    • Barbier, C.1    Loubieres, Y.2    Schmit, C.3    Hayon, J.4    Ricome, J.-L.5    Jardin, F.6    Vieillard-Baron, A.7
  • 8
    • 2542457136 scopus 로고    scopus 로고
    • The respiratory variation in inferior vena cava diameter as a guide to fluid therapy
    • DOI 10.1007/s00134-004-2233-5
    • Feissel M, Michard F, Faller JP, Teboul JL. The respiratory variation in inferior vena cava diameter as a guide to fluid therapy. Intensive Care Med 2004; 30:1834-1837. (Pubitemid 39297190)
    • (2004) Intensive Care Medicine , vol.30 , Issue.9 , pp. 1834-1837
    • Feissel, M.1    Michard, F.2    Faller, J.-P.3    Teboul, J.-L.4
  • 9
  • 10
    • 38349056567 scopus 로고    scopus 로고
    • Fluid therapy in resuscitated sepsis: Less is more
    • Durairaj L, Schmidt GA. Fluid therapy in resuscitated sepsis: Less is more. Chest 2008; 133:252-263.
    • (2008) Chest , vol.133 , pp. 252-263
    • Durairaj, L.1    Schmidt, G.A.2
  • 11
    • 0034087866 scopus 로고    scopus 로고
    • Negative fluid balance predicts survival in patients with septic shock: A retrospective pilot study
    • Alsous F, Khamiees M, DeGirolamo A, et al. Negative fluid balance predicts survival in patients with septic shock: A retrospective pilot study. Chest 2000; 117:1749-1754. (Pubitemid 30413373)
    • (2000) Chest , vol.117 , Issue.6 , pp. 1749-1754
    • Alsous, F.1    Khamiees, M.2    DeGirolamo, A.3    Amoateng-Adjepong, Y.4    Manthous, C.A.5
  • 13
    • 67650825201 scopus 로고    scopus 로고
    • The importance of fluid management in acute lung injury secondary to septic shock
    • Murphy CV, Schramm GE, Doherty JA, et al. The importance of fluid management in acute lung injury secondary to septic shock. Chest 2009; 136:102-109.
    • (2009) Chest , vol.136 , pp. 102-109
    • Murphy, C.V.1    Schramm, G.E.2    Doherty, J.A.3
  • 14
    • 12144287425 scopus 로고    scopus 로고
    • Pulmonary artery occlusion pressure and central venous pressure fail to predict ventricular filling volume, cardiac performance, or the response to volume infusion in normal subjects
    • DOI 10.1097/01.CCM.0000114996.68110.C9
    • Kumar A, Anel R, Bunnell E, et al. Pulmonary artery occlusion pressure and central venous pressure fail to predict ventricular filling volume, cardiac performance, or the response to volume infusion in normal subjects. Crit Care Med 2004; 32:691-699. (Pubitemid 38340065)
    • (2004) Critical Care Medicine , vol.32 , Issue.3 , pp. 691-699
    • Kumar, A.1    Anel, R.2    Bunnell, E.3    Habet, K.4    Zanotti, S.5    Marshall, S.6    Neumann, A.7    Ali, A.8    Cheang, M.9    Kavinsky, C.10    Parrillo, J.E.11
  • 15
    • 33845958648 scopus 로고    scopus 로고
    • Cardiac filling pressures are not appropriate to predict hemodynamic response to volume challenge
    • DOI 10.1097/01.CCM.0000249851.94101.4F, PII 0000324620070100000011
    • Osman D, Ridel C, Ray P, et al. Cardiac filling pressures are not appropriate to predict hemodynamic response to volume challenge. Crit Care Med 2007; 35:64-68. (Pubitemid 46035678)
    • (2007) Critical Care Medicine , vol.35 , Issue.1 , pp. 64-68
    • Osman, D.1    Ridel, C.2    Ray, P.3    Monnet, X.4    Anguel, N.5    Richard, C.6    Teboul, J.-L.7
  • 16
    • 41349122492 scopus 로고    scopus 로고
    • The ability of a novel algorithm for automatic estimation of the respiratory variations in arterial pulse pressure to monitor fluid responsiveness in the operating room
    • DOI 10.1213/01.ane.0000297291.01615.5c, PII 0000053920080400000024
    • Cannesson M, Slieker J, Desebbe O, et al. The ability of a novel algorithm for automatic estimation of the respiratory variations in arterial pulse pressure to monitor fluid responsiveness in the operating room. Anesth Analg 2008; 106:1195-1200. (Pubitemid 351450545)
    • (2008) Anesthesia and Analgesia , vol.106 , Issue.4 , pp. 1195-1200
    • Cannesson, M.1    Slieker, J.2    Desebbe, O.3    Bauer, C.4    Chiari, P.5    Henaine, R.6    Lehot, J.-J.7
  • 17
    • 56449113016 scopus 로고    scopus 로고
    • Uncalibrated pulse contour-derived stroke volume variation predicts fluid responsiveness in mechanically ventilated patients undergoing liver transplantation
    • Biais M, Nouette-Gaulain K, Cottenceau V, et al. Uncalibrated pulse contour-derived stroke volume variation predicts fluid responsiveness in mechanically ventilated patients undergoing liver transplantation. Br J Anaesth 2008; 101:761-768.
    • (2008) Br J Anaesth , vol.101 , pp. 761-768
    • Biais, M.1    Nouette-Gaulain, K.2    Cottenceau, V.3
  • 18
    • 47149111264 scopus 로고    scopus 로고
    • Assessment of stroke volume variation for prediction of fluid responsiveness using the modified FloTrac and PiCCOplus system
    • Hofer CK, Senn A, Weibel L, Zollinger A. Assessment of stroke volume variation for prediction of fluid responsiveness using the modified FloTrac and PiCCOplus system. Crit Care 2008; 12:R82.
    • (2008) Crit Care , vol.12
    • Hofer, C.K.1    Senn, A.2    Weibel, L.3    Zollinger, A.4
  • 19
    • 69349089330 scopus 로고    scopus 로고
    • Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: A systematic review of the literature
    • Marik PE, Cavallazzi R, Vasu T, Hirani A. Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: A systematic review of the literature. Crit Care Med 2009; 37:2642-2647.
    • (2009) Crit Care Med , vol.37 , pp. 2642-2647
    • Marik, P.E.1    Cavallazzi, R.2    Vasu, T.3    Hirani, A.4
  • 20
    • 59649123027 scopus 로고    scopus 로고
    • The ability of stroke volume variations obtained with Vigileo/FloTrac system to monitor fluid responsiveness in mechanically ventilated patients
    • Cannesson M, Musard H, Desebbe O, et al. The ability of stroke volume variations obtained with Vigileo/FloTrac system to monitor fluid responsiveness in mechanically ventilated patients. Anesth Analg 2009; 108:513-517.
    • (2009) Anesth Analg , vol.108 , pp. 513-517
    • Cannesson, M.1    Musard, H.2    Desebbe, O.3
  • 21
    • 0036137453 scopus 로고    scopus 로고
    • Optimizing fluid therapy in mechanically ventilated patients after cardiac surgery by on-line monitoring of left ventricular stroke volume variations. Comparison with aortic systolic pressure variations
    • DOI 10.1093/bja/88.1.124
    • Reuter DA, Felbinger TW, Kilger E, et al. Optimizing fluid therapy in mechanically ventilated patients after cardiac surgery by on-line monitoring of left ventricular stroke volume variations. Comparison with aortic systolic pressure variations. Br J Anaesth 2002; 88:124-126. (Pubitemid 34048570)
    • (2002) British Journal of Anaesthesia , vol.88 , Issue.1 , pp. 124-126
    • Reuter, D.A.1    Felbinger, T.W.2    Kilger, E.3    Schmidt, C.4    Lamm, P.5    Goetz, A.E.6
  • 22
    • 71749103572 scopus 로고    scopus 로고
    • Automated pulse pressure and stroke volume variations from radial artery: Evaluation during major abdominal surgery
    • Derichard A, Robin E, Tavernier B, et al. Automated pulse pressure and stroke volume variations from radial artery: Evaluation during major abdominal surgery. Br J Anaesth 2009; 103:678-684.
    • (2009) Br J Anaesth , vol.103 , pp. 678-684
    • Derichard, A.1    Robin, E.2    Tavernier, B.3
  • 23
    • 77949403336 scopus 로고    scopus 로고
    • Abilities of pulse pressure variations and stroke volume variations to predict fluid responsiveness in prone position during scoliosis surgery
    • Biais M, Bernard O, Ha JC, et al. Abilities of pulse pressure variations and stroke volume variations to predict fluid responsiveness in prone position during scoliosis surgery. Br J Anaesth 2010; 104:407-413.
    • (2010) Br J Anaesth , vol.104 , pp. 407-413
    • Biais, M.1    Bernard, O.2    Ha, J.C.3
  • 24
    • 26844502897 scopus 로고    scopus 로고
    • Edwards FloTrac sensor and Vigileo monitor: Easy, accurate, reliable cardiac output assessment using the arterial pulse wave
    • DOI 10.1586/17434440.2.5.523
    • Manecke GR. Edwards FloTrac sensor and Vigileo monitor: Easy, accurate, reliable cardiac output assessment using the arterial pulse wave. Expert Rev Med Devices 2005; 2:523-527. (Pubitemid 41447649)
    • (2005) Expert Review of Medical Devices , vol.2 , Issue.5 , pp. 523-527
    • Manecke, G.R.1
  • 25
    • 77953533489 scopus 로고    scopus 로고
    • Intraoperative fluid optimization using stroke volume variation in high risk surgical patients: Results of prospective randomized study
    • Benes J, Chytra I, Altmann P, et al. Intraoperative fluid optimization using stroke volume variation in high risk surgical patients: Results of prospective randomized study. Crit Care 2010; 14:R118.
    • (2010) Crit Care , vol.14
    • Benes, J.1    Chytra, I.2    Altmann, P.3
  • 29
    • 79951677469 scopus 로고    scopus 로고
    • Dynamic arterial elastance to predict arterial pressure response to volume loading in preload-dependent patients
    • Monge Garcia MI, Gil Cano A, Gracia Romero M. Dynamic arterial elastance to predict arterial pressure response to volume loading in preload-dependent patients. Crit Care 2011; 15:R15.
    • (2011) Crit Care , vol.15
    • Monge Garcia, M.I.1    Gil Cano, A.2    Gracia Romero, M.3
  • 30
    • 0020524559 scopus 로고
    • A method of comparing the areas under receiver operating characteristic curves derived from the same cases
    • Hanley JA, McNeil BJ. A method of comparing the areas under receiver operating characteristic curves derived from the same cases. Radiology 1983; 148:839-843. (Pubitemid 13033817)
    • (1983) Radiology , vol.148 , Issue.3 , pp. 839-843
    • Hanley, J.A.1    McNeil, B.J.2
  • 31
    • 77950022940 scopus 로고    scopus 로고
    • Uncalibrated radial and femoral arterial pressure waveform analysis for continuous cardiac output measurement: An evaluation in cardiac surgery patients
    • Hofer CK, Button D, Weibel L, et al. Uncalibrated radial and femoral arterial pressure waveform analysis for continuous cardiac output measurement: An evaluation in cardiac surgery patients. J Cardiothorac Vasc Anesth 2010; 24:257-264.
    • (2010) J Cardiothorac Vasc Anesth , vol.24 , pp. 257-264
    • Hofer, C.K.1    Button, D.2    Weibel, L.3
  • 32
    • 33846669409 scopus 로고    scopus 로고
    • Cardiac Output Determination From the Arterial Pressure Wave: Clinical Testing of a Novel Algorithm That Does Not Require Calibration
    • DOI 10.1053/j.jvca.2006.08.004, PII S1053077006003119
    • Manecke GR Jr, Auger WR. Cardiac output determination from the arterial pressure wave: Clinical testing of a novel algorithm that does not require calibration. J Cardiothorac Vasc Anesth 2007; 21:3-7. (Pubitemid 46199245)
    • (2007) Journal of Cardiothoracic and Vascular Anesthesia , vol.21 , Issue.1 , pp. 3-7
    • Manecke Jr., G.R.1    Auger, W.R.2
  • 33
    • 34948909129 scopus 로고    scopus 로고
    • Goal-directed fluid management based on pulse pressure variation monitoring during high-risk surgery: A pilot randomized controlled trial
    • Lopes MR, Oliveira MA, Pereira VO, et al. Goal-directed fluid management based on pulse pressure variation monitoring during high-risk surgery: A pilot randomized controlled trial. Crit Care 2007; 11:R100.
    • (2007) Crit Care , vol.11
    • Lopes, M.R.1    Oliveira, M.A.2    Pereira, V.O.3
  • 34
    • 34548254794 scopus 로고    scopus 로고
    • Measurement of cardiac output: A comparison between transpulmonary thermodilution and uncalibrated pulse contour analysis
    • DOI 10.1093/bja/aem177
    • Sakka SG, Kozieras J, Thuemer O, van Hout N. Measurement of cardiac output: A comparison between transpulmonary thermodilution and uncalibrated pulse contour analysis. Br J Anaesth 2007; 99:337-342. (Pubitemid 47316386)
    • (2007) British Journal of Anaesthesia , vol.99 , Issue.3 , pp. 337-342
    • Sakka, S.G.1    Kozieras, J.2    Thuemer, O.3    Van Hout, N.4
  • 35
    • 77953245170 scopus 로고    scopus 로고
    • Arterial pressure-based cardiac output in septic patients: Different accuracy of pulse contour and uncalibrated pressure waveform devices
    • Monnet X, Anguel N, Naudin B, et al. Arterial pressure-based cardiac output in septic patients: Different accuracy of pulse contour and uncalibrated pressure waveform devices. Crit Care 2010; 14:R109.
    • (2010) Crit Care , vol.14
    • Monnet, X.1    Anguel, N.2    Naudin, B.3
  • 36
    • 79953827557 scopus 로고    scopus 로고
    • Arterial pressure-based cardiac output monitoring: A multicenter validation of the third-generation software in septic patients
    • De Backer D, Marx G, Tan A, et al. Arterial pressure-based cardiac output monitoring: A multicenter validation of the third-generation software in septic patients. Intensive Care Med 2011; 37:233-240.
    • (2011) Intensive Care Med , vol.37 , pp. 233-240
    • De Backer, D.1    Marx, G.2    Tan, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.