메뉴 건너뛰기




Volumn 9, Issue 5, 2016, Pages 682-699

Iohexol plasma clearance for measuring glomerular filtration rate in clinical practice and research: A review. Part 1: How to measure glomerular filtration rate with iohexol?

(17)  Delanaye, Pierre a   Ebert, Natalie b   Melsom, Toralf c,d   Gaspari, Flavio e   Mariat, Christophe f   Cavalier, Etienne a   Björk, Jonas g   Christensson, Anders h   Nyman, Ulf h   Porrini, Esteban i   Remuzzi, Giuseppe j,k   Ruggenenti, Piero j,k   Schaeffner, Elke b   Soveri, Inga l   Sterner, Gunnar h   Eriksen, Bjørn Odvar c,d   Bäck, Sten Erik h  


Author keywords

Glomerular filtration rate; Iohexol

Indexed keywords

BIOLOGICAL MARKER; CREATININE; IOHEXOL;

EID: 84995569547     PISSN: 20488505     EISSN: 20488513     Source Type: Journal    
DOI: 10.1093/ckj/sfw070     Document Type: Review
Times cited : (180)

References (178)
  • 2
    • 0006081723 scopus 로고
    • The excretion of inulin, xylose, and urea by normal and phorizinized man
    • Shannon JA, Smith HW. The excretion of inulin, xylose, and urea by normal and phorizinized man. J Clin Invest 1935; 14: 393-401.
    • (1935) J Clin Invest , vol.14 , pp. 393-401
    • Shannon, J.A.1    Smith, H.W.2
  • 3
    • 84908121455 scopus 로고    scopus 로고
    • Measuring GFR: A systematic review
    • Soveri I, Berg UB, Björk J et al. Measuring GFR: A systematic review. Am J Kidney Dis 2014; 64: 411-424.
    • (2014) Am J Kidney Dis , vol.64 , pp. 411-424
    • Soveri, I.1    Berg, U.B.2    Björk, J.3
  • 4
    • 64049084692 scopus 로고    scopus 로고
    • Assessment of iothalamate plasma clearance: Duration of study affects quality of GFR
    • Agarwal R, Bills JE, Yigazu PM et al. Assessment of iothalamate plasma clearance: duration of study affects quality of GFR. Clin J Am Soc Nephrol 2009; 4: 77-85.
    • (2009) Clin J Am Soc Nephrol , vol.4 , pp. 77-85
    • Agarwal, R.1    Bills, J.E.2    Yigazu, P.M.3
  • 5
    • 0017559559 scopus 로고
    • Single injection (51Cr)EDTA plasma clearance determination in children using capillary blood samples
    • Brochner-Mortensen J, Christoffersen J. Single injection (51Cr)EDTA plasma clearance determination in children using capillary blood samples. Scand J Clin Lab Invest 1977; 37: 631-633.
    • (1977) Scand J Clin Lab Invest , vol.37 , pp. 631-633
    • Brochner-Mortensen, J.1    Christoffersen, J.2
  • 6
    • 0031912549 scopus 로고    scopus 로고
    • Precision of plasma clearance of iohexol for estimation of GFR in patients with renal disease
    • Gaspari F, Perico N, Matalone M et al. Precision of plasma clearance of iohexol for estimation of GFR in patients with renal disease. J Am Soc Nephrol 1998; 9: 310-313.
    • (1998) J Am Soc Nephrol , vol.9 , pp. 310-313
    • Gaspari, F.1    Perico, N.2    Matalone, M.3
  • 7
    • 84879868123 scopus 로고    scopus 로고
    • Con: Should we abandon the use of the MDRD equation in favour of the CKD-EPI equation?
    • Delanaye P, Pottel H, Botev R. Con: Should we abandon the use of the MDRD equation in favour of the CKD-EPI equation? Nephrol Dial Transplant 2013; 28: 1396-1403.
    • (2013) Nephrol Dial Transplant , vol.28 , pp. 1396-1403
    • Delanaye, P.1    Pottel, H.2    Botev, R.3
  • 8
    • 84883197118 scopus 로고    scopus 로고
    • The applicability of EGFR equations to different populations
    • Delanaye P, Mariat C. The applicability of eGFR equations to different populations. Nat Rev Nephrol 2013; 9: 513-522.
    • (2013) Nat Rev Nephrol , vol.9 , pp. 513-522
    • Delanaye, P.1    Mariat, C.2
  • 9
    • 72049116346 scopus 로고    scopus 로고
    • Measured GFR as a confirmatory test for estimated GFR
    • Stevens LA, Levey AS. Measured GFR as a confirmatory test for estimated GFR. J Am Soc Nephrol 2009; 20: 2305-2313.
    • (2009) J Am Soc Nephrol , vol.20 , pp. 2305-2313
    • Stevens, L.A.1    Levey, A.S.2
  • 10
    • 84957084008 scopus 로고    scopus 로고
    • Residual associations of inflammatory markers with EGFR after accounting for measured GFR in a community-based cohort without CKD
    • Schei J, Stefansson VTN, Mathisen UD et al. Residual associations of inflammatory markers with eGFR after accounting for measured GFR in a community-based cohort without CKD. Clin J Am Soc Nephrol 2016; 11: 280-286.
    • (2016) Clin J Am Soc Nephrol , vol.11 , pp. 280-286
    • Schei, J.1    Stefansson, V.T.N.2    Mathisen, U.D.3
  • 11
    • 84921892756 scopus 로고    scopus 로고
    • Estimated GFR is biased by non-Traditional cardiovascular risk factors
    • Melsom T, Fuskevåg OM, Mathisen UD et al. Estimated GFR is biased by non-Traditional cardiovascular risk factors. Am J Nephrol 2015; 41: 7-15.
    • (2015) Am J Nephrol , vol.41 , pp. 7-15
    • Melsom, T.1    Fuskevåg, O.M.2    Mathisen, U.D.3
  • 12
    • 61349147106 scopus 로고    scopus 로고
    • Factors other than glomerular filtration rate affect serum cystatin C levels
    • Stevens LA, Schmid CH, Greene T et al. Factors other than glomerular filtration rate affect serum cystatin C levels. Kidney Int 2009; 75: 652-660.
    • (2009) Kidney Int , vol.75 , pp. 652-660
    • Stevens, L.A.1    Schmid, C.H.2    Greene, T.3
  • 13
    • 84879687867 scopus 로고    scopus 로고
    • The GFR and GFR decline cannot be accurately estimated in type 2 diabetics
    • Gaspari F, Ruggenenti P, Porrini E et al. The GFR and GFR decline cannot be accurately estimated in type 2 diabetics. Kidney Int 2013; 84: 164-173.
    • (2013) Kidney Int , vol.84 , pp. 164-173
    • Gaspari, F.1    Ruggenenti, P.2    Porrini, E.3
  • 14
    • 78649676122 scopus 로고    scopus 로고
    • Cystatin C is not a better estimator of GFR than plasmacreatinine in the general population
    • Eriksen BO, Mathisen UD, Melsom T et al. Cystatin C is not a better estimator of GFR than plasmacreatinine in the general population. Kidney Int 2010; 78: 1305-1311.
    • (2010) Kidney Int , vol.78 , pp. 1305-1311
    • Eriksen, B.O.1    Mathisen, U.D.2    Melsom, T.3
  • 15
    • 33748649858 scopus 로고    scopus 로고
    • Creatinine-based formulae for the estimation of glomerular filtration rate in heart transplant recipients
    • Delanaye P, Nellessen E, Grosch S et al. Creatinine-based formulae for the estimation of glomerular filtration rate in heart transplant recipients. Clin Transplant 2006; 20: 596-603.
    • (2006) Clin Transplant , vol.20 , pp. 596-603
    • Delanaye, P.1    Nellessen, E.2    Grosch, S.3
  • 16
    • 84878582187 scopus 로고    scopus 로고
    • MDRD versus CKD-EPI equation to estimate glomerular filtration rate in kidney transplant recipients
    • Masson I, Flamant M, Maillard N et al. MDRD versus CKD-EPI equation to estimate glomerular filtration rate in kidney transplant recipients. Transplantation 2013; 95: 1211-1217.
    • (2013) Transplantation , vol.95 , pp. 1211-1217
    • Masson, I.1    Flamant, M.2    Maillard, N.3
  • 17
    • 84952342703 scopus 로고    scopus 로고
    • Estimated glomerular filtration rate in renal transplantation: The nephrologist in the mist
    • Luis-Lima S, Marrero-Miranda D, González-Rinne A et al. Estimated glomerular filtration rate in renal transplantation: The nephrologist in the mist. Transplantation 2015; 99: 2625-2633.
    • (2015) Transplantation , vol.99 , pp. 2625-2633
    • Luis-Lima, S.1    Marrero-Miranda, D.2    González-Rinne, A.3
  • 18
    • 84983143225 scopus 로고    scopus 로고
    • GFR estimating equations and liver disease
    • Beben T, Rifkin DE. GFR estimating equations and liver disease. Adv Chronic Kidney Dis 2015; 22: 337-342.
    • (2015) Adv Chronic Kidney Dis , vol.22 , pp. 337-342
    • Beben, T.1    Rifkin, D.E.2
  • 19
    • 0020968616 scopus 로고
    • Experimental investigations with iohexol and their clinical relevance
    • Almén T. Experimental investigations with iohexol and their clinical relevance. Acta Radiol Suppl 1983; 366: 9-19.
    • (1983) Acta Radiol Suppl , vol.366 , pp. 9-19
    • Almén, T.1
  • 20
    • 0001769851 scopus 로고
    • Development of nonionic contrast media
    • Almén T. Development of nonionic contrast media. Invest Radiol 1985; 20: S2-S9.
    • (1985) Invest Radiol , vol.20 , pp. S2-S9
    • Almén, T.1
  • 21
    • 0019225230 scopus 로고
    • Tolerance and excretion of iohexol after intravenous injection in healthy volunteers. Preliminary report
    • Aakhus T, Sommerfelt SC, Stormorken H et al. Tolerance and excretion of iohexol after intravenous injection in healthy volunteers. Preliminary report. Acta Radiol Suppl 1980; 362: 131-134.
    • (1980) Acta Radiol Suppl , vol.362 , pp. 131-134
    • Aakhus, T.1    Sommerfelt, S.C.2    Stormorken, H.3
  • 22
    • 0020531367 scopus 로고
    • Human pharmacokinetics of iohexol. A new nonionic contrast medium
    • Olsson B, Aulie A, Sveen K et al. Human pharmacokinetics of iohexol. A new nonionic contrast medium. Invest Radiol 1983; 18: 177-182.
    • (1983) Invest Radiol , vol.18 , pp. 177-182
    • Olsson, B.1    Aulie, A.2    Sveen, K.3
  • 23
    • 77954192357 scopus 로고    scopus 로고
    • Measuring the glomerular filtration rate in obese individuals without overt kidney disease
    • Friedman AN, Strother M, Quinney SK et al. Measuring the glomerular filtration rate in obese individuals without overt kidney disease. Nephron Clin Pract 2010; 116: c224-c234.
    • (2010) Nephron Clin Pract , vol.116 , pp. c224-c234
    • Friedman, A.N.1    Strother, M.2    Quinney, S.K.3
  • 24
    • 0029074037 scopus 로고
    • Elimination of the non-ionic X-ray contrast media iodixanol and iohexol in patients with severely impaired renal function
    • Nossen JO, Jakobsen JA, Kjaersgaard P et al. Elimination of the non-ionic X-ray contrast media iodixanol and iohexol in patients with severely impaired renal function. Scand J Clin Lab Invest 1995; 55: 341-350.
    • (1995) Scand J Clin Lab Invest , vol.55 , pp. 341-350
    • Nossen, J.O.1    Jakobsen, J.A.2    Kjaersgaard, P.3
  • 25
    • 0021256655 scopus 로고
    • Pharmacokinetics of iohexol, a new nonionic radiocontrast agent, in humans
    • Edelson J, Shaw D, Palace G. Pharmacokinetics of iohexol, a new nonionic radiocontrast agent, in humans. J Pharm Sci 1984; 73: 993-995.
    • (1984) J Pharm Sci , vol.73 , pp. 993-995
    • Edelson, J.1    Shaw, D.2    Palace, G.3
  • 26
    • 0023894459 scopus 로고
    • Contrast media as markers for glomerular filtration: A pharmacokinetic comparison of four agents
    • Bäck SE, Krutzen E, Nilsson-Ehle P. Contrast media as markers for glomerular filtration: A pharmacokinetic comparison of four agents. Scand J Clin Lab Invest 1988; 48: 247-253.
    • (1988) Scand J Clin Lab Invest , vol.48 , pp. 247-253
    • Bäck, S.E.1    Krutzen, E.2    Nilsson-Ehle, P.3
  • 27
    • 0030048468 scopus 로고    scopus 로고
    • Iohexol clearance for assessment of glomerular filtration rate in diabetic pregnancy
    • Olofsson P, Krutzen E, Nilsson-Ehle P. Iohexol clearance for assessment of glomerular filtration rate in diabetic pregnancy. Eur J Obstet Gynecol Reprod Biol 1996; 64: 63-67.
    • (1996) Eur J Obstet Gynecol Reprod Biol , vol.64 , pp. 63-67
    • Olofsson, P.1    Krutzen, E.2    Nilsson-Ehle, P.3
  • 28
    • 33745226165 scopus 로고    scopus 로고
    • Glomerular filtration rate via plasma iohexol disappearance: Pilot study for chronic kidney disease in children
    • Schwartz GJ, Furth S, Cole SR et al. Glomerular filtration rate via plasma iohexol disappearance: pilot study for chronic kidney disease in children. Kidney Int 2006; 69: 2070-2077.
    • (2006) Kidney Int , vol.69 , pp. 2070-2077
    • Schwartz, G.J.1    Furth, S.2    Cole, S.R.3
  • 29
    • 0019225225 scopus 로고
    • Biochemical-pharmacologic properties of iohexol
    • Mutzel W, Siefert HM, Speck U. Biochemical-pharmacologic properties of iohexol. Acta Radiol Suppl 1980; 362: 111-115.
    • (1980) Acta Radiol Suppl , vol.362 , pp. 111-115
    • Mutzel, W.1    Siefert, H.M.2    Speck, U.3
  • 30
    • 0021672741 scopus 로고
    • Plasma clearance of a new contrast agent, iohexol: A method for the assessment of glomerular filtration rate
    • Krutzen E, Bäck SE, Nilsson-Ehle I et al. Plasma clearance of a new contrast agent, iohexol: A method for the assessment of glomerular filtration rate. J Lab Clin Med 1984; 104: 955-961.
    • (1984) J Lab Clin Med , vol.104 , pp. 955-961
    • Krutzen, E.1    Bäck, S.E.2    Nilsson-Ehle, I.3
  • 31
    • 0023457378 scopus 로고
    • Physicochemical properties and degree of protein binding of iopentol
    • Skinnemoen K. Physicochemical properties and degree of protein binding of iopentol. Acta Radiol Suppl 1987; 370: 33-36.
    • (1987) Acta Radiol Suppl , vol.370 , pp. 33-36
    • Skinnemoen, K.1
  • 32
    • 84954451086 scopus 로고    scopus 로고
    • Discordance between iothalamate and iohexol urinary clearances
    • Seegmiller JC, Burns BE, Schinstock CA et al. Discordance between iothalamate and iohexol urinary clearances. Am J Kidney Dis 2016; 67: 49-55.
    • (2016) Am J Kidney Dis , vol.67 , pp. 49-55
    • Seegmiller, J.C.1    Burns, B.E.2    Schinstock, C.A.3
  • 33
    • 0028230986 scopus 로고
    • Determination of low glomerular filtration rate using iohexol clearance
    • Frennby B, Sterner G, Almen T et al. Determination of low glomerular filtration rate using iohexol clearance. Invest Radiol 1994; 29 (Suppl 2): S234-S235.
    • (1994) Invest Radiol , vol.29 , pp. S234-S235
    • Frennby, B.1    Sterner, G.2    Almen, T.3
  • 34
    • 0030052705 scopus 로고    scopus 로고
    • Determination of residual renal function with iohexol clearance in hemodialysis patients
    • Swan SK, Halstenson CE, Kasiske BL et al. Determination of residual renal function with iohexol clearance in hemodialysis patients. Kidney Int 1996; 49: 232-235.
    • (1996) Kidney Int , vol.49 , pp. 232-235
    • Swan, S.K.1    Halstenson, C.E.2    Kasiske, B.L.3
  • 35
    • 0033843727 scopus 로고    scopus 로고
    • Assessing residual renal function and efficiency of hemodialysis-An application for urographic contrast media
    • Sterner G, Frennby B, Månsson S et al. Assessing residual renal function and efficiency of hemodialysis-An application for urographic contrast media. Nephron 2000; 85: 324-333.
    • (2000) Nephron , vol.85 , pp. 324-333
    • Sterner, G.1    Frennby, B.2    Månsson, S.3
  • 36
    • 0025146899 scopus 로고
    • Plasma and renal clearance of iohexol-A study on the reproducibility of a method for the glomerular filtration rate
    • Arvidsson A, Hedman A. Plasma and renal clearance of iohexol-A study on the reproducibility of a method for the glomerular filtration rate. Scand J Clin Lab Invest 1990; 50: 757-761.
    • (1990) Scand J Clin Lab Invest , vol.50 , pp. 757-761
    • Arvidsson, A.1    Hedman, A.2
  • 37
    • 0015094143 scopus 로고
    • Simplified measurement of glomerular filtration rate
    • Cangiano JL, Genuth SM, Renerts L et al. Simplified measurement of glomerular filtration rate. Invest Urol 1971; 9: 34-38.
    • (1971) Invest Urol , vol.9 , pp. 34-38
    • Cangiano, J.L.1    Genuth, S.M.2    Renerts, L.3
  • 38
    • 0024235429 scopus 로고
    • Pharmacokinetics of iothalamate in endstage renal disease
    • Evans JR, Cutler RE, Forland SC. Pharmacokinetics of iothalamate in endstage renal disease. J Clin Pharmacol 1988; 28: 826-830.
    • (1988) J Clin Pharmacol , vol.28 , pp. 826-830
    • Evans, J.R.1    Cutler, R.E.2    Forland, S.C.3
  • 39
    • 0032792033 scopus 로고    scopus 로고
    • Comparison of iothalamate clearance methods for measuring GFR
    • Dowling TC, Frye RF, Fraley DS et al. Comparison of iothalamate clearance methods for measuring GFR. Pharmacotherapy 1999; 19: 943-950.
    • (1999) Pharmacotherapy , vol.19 , pp. 943-950
    • Dowling, T.C.1    Frye, R.F.2    Fraley, D.S.3
  • 40
    • 0018186615 scopus 로고
    • Determination of glomerular filtration rate in advanced renal insufficiency
    • Jagenburg R, Attman PO, Aurell M et al. Determination of glomerular filtration rate in advanced renal insufficiency. Scand J Urol Nephrol 1978; 12: 133-137.
    • (1978) Scand J Urol Nephrol , vol.12 , pp. 133-137
    • Jagenburg, R.1    Attman, P.O.2    Aurell, M.3
  • 41
    • 0017187888 scopus 로고
    • Comparison between total and renal plasma clearance of [51Cr] EDTA
    • Brochner-Mortensen J, Rodbro P. Comparison between total and renal plasma clearance of [51Cr] EDTA. Scand J Clin Lab Invest 1976; 36: 247-249.
    • (1976) Scand J Clin Lab Invest , vol.36 , pp. 247-249
    • Brochner-Mortensen, J.1    Rodbro, P.2
  • 42
    • 0021895404 scopus 로고
    • Is 125I iothalamate an ideal marker for glomerular filtration?
    • Odlind B, Hallgren R, Sohtell M et al. Is 125I iothalamate an ideal marker for glomerular filtration? Kidney Int 1985; 27: 9-16.
    • (1985) Kidney Int , vol.27 , pp. 9-16
    • Odlind, B.1    Hallgren, R.2    Sohtell, M.3
  • 43
    • 0021276653 scopus 로고
    • Mechanism of renal excretion of various X-ray contrast materials in Rabbits
    • Zurth C. Mechanism of renal excretion of various X-ray contrast materials in Rabbits. Invest Radiol 1983; 19: 110-115.
    • (1983) Invest Radiol , vol.19 , pp. 110-115
    • Zurth, C.1
  • 44
    • 0021337031 scopus 로고
    • Electrocardiographic changes during intravenous urography: A study with sodium iothalamate and iohexol
    • Heron CW, Underwood SR, Dawson P. Electrocardiographic changes during intravenous urography: A study with sodium iothalamate and iohexol. Clin Radiol 1984; 35: 137-141.
    • (1984) Clin Radiol , vol.35 , pp. 137-141
    • Heron, C.W.1    Underwood, S.R.2    Dawson, P.3
  • 45
    • 0027980257 scopus 로고
    • Accurate and feasible measurements of GFR-is the iohexol clearance the answer?
    • Aurell M. Accurate and feasible measurements of GFR-is the iohexol clearance the answer? Nephrol Dial Transplant 1994; 9: 1222-1224.
    • (1994) Nephrol Dial Transplant , vol.9 , pp. 1222-1224
    • Aurell, M.1
  • 46
    • 0028542209 scopus 로고
    • New markers for the determination of GFR: Iohexol clearance and cystatin C serum concentration
    • Nilsson-Ehle P, Grubb A. New markers for the determination of GFR: iohexol clearance and cystatin C serum concentration. Kidney Int Suppl 1994; 47: S17-S19.
    • (1994) Kidney Int Suppl , vol.47 , pp. S17-S19
    • Nilsson-Ehle, P.1    Grubb, A.2
  • 47
    • 17544405366 scopus 로고    scopus 로고
    • Iohexol clearance for the determination of glomerular filtration rate: 15 years' experience in clinical practice
    • Nilsson-Ehle P. Iohexol clearance for the determination of glomerular filtration rate: 15 years' experience in clinical practice. eJIFCC 2002; 13: 1-5.
    • (2002) EJIFCC , vol.13 , pp. 1-5
    • Nilsson-Ehle, P.1
  • 48
    • 0028944918 scopus 로고
    • The use of iohexol clearance to determine GFR in patients with severe chronic renal failure-A comparison between different clearance techniques
    • Frennby B, Sterner G, Almen T et al. The use of iohexol clearance to determine GFR in patients with severe chronic renal failure-A comparison between different clearance techniques. Clin Nephrol 1995; 43: 35-46.
    • (1995) Clin Nephrol , vol.43 , pp. 35-46
    • Frennby, B.1    Sterner, G.2    Almen, T.3
  • 49
    • 0026448041 scopus 로고
    • Iohexol in serumdetermined by capillary electrophoresis
    • Shihabi ZK, Constantinescu MS. Iohexol in serumdetermined by capillary electrophoresis. Clin Chem 1992; 38: 2117-2120.
    • (1992) Clin Chem , vol.38 , pp. 2117-2120
    • Shihabi, Z.K.1    Constantinescu, M.S.2
  • 50
    • 0029825013 scopus 로고    scopus 로고
    • Capillary electrophoresis for the determination of glomerular filtration rate using nonradioactive iohexol
    • Rocco MV, Buckalew VM Jr, Moore LC et al. Capillary electrophoresis for the determination of glomerular filtration rate using nonradioactive iohexol. Am J Kidney Dis 1996; 28: 173-177.
    • (1996) Am J Kidney Dis , vol.28 , pp. 173-177
    • Rocco, M.V.1    Buckalew, V.M.2    Moore, L.C.3
  • 51
    • 50049114927 scopus 로고    scopus 로고
    • Performance of iohexol determination in serum and urine by HPLC: Validation, risk and uncertainty assessment
    • Cavalier E, Rozet E, Dubois N et al. Performance of iohexol determination in serum and urine by HPLC: validation, risk and uncertainty assessment. Clin Chim Acta 2008; 396: 80-85.
    • (2008) Clin Chim Acta , vol.396 , pp. 80-85
    • Cavalier, E.1    Rozet, E.2    Dubois, N.3
  • 52
    • 0029090867 scopus 로고
    • Plasma clearance of nonradioactive iohexol as a measure of glomerular filtration rate
    • Gaspari F, Perico N, Ruggenenti P et al. Plasma clearance of nonradioactive iohexol as a measure of glomerular filtration rate. J Am Soc Nephrol 1995; 6: 257-263.
    • (1995) J Am Soc Nephrol , vol.6 , pp. 257-263
    • Gaspari, F.1    Perico, N.2    Ruggenenti, P.3
  • 53
    • 12444261826 scopus 로고    scopus 로고
    • Development and validation of an HPLC-UV method for determination of iohexol in human plasma
    • Soman RS, Zahir H, Akhlaghi F. Development and validation of an HPLC-UV method for determination of iohexol in human plasma. J Chromatogr B Analyt Technol Biomed Life Sci 2005; 816: 339-343.
    • (2005) J Chromatogr B Analyt Technol Biomed Life Sci , vol.816 , pp. 339-343
    • Soman, R.S.1    Zahir, H.2    Akhlaghi, F.3
  • 54
    • 26844572621 scopus 로고    scopus 로고
    • Simple HPLC-UV method for determination of iohexol, iothalamate, p-Aminohippuric acid and n-Acetyl-p-Aminohippuric acid in human plasma and urine with ERPF, GFR and ERPF/GFR ratio determination using colorimetric analysis
    • Farthing D, Sica DA, Fakhry I et al. Simple HPLC-UV method for determination of iohexol, iothalamate, p-Aminohippuric acid and n-Acetyl-p-Aminohippuric acid in human plasma and urine with ERPF, GFR and ERPF/GFR ratio determination using colorimetric analysis. J Chromatogr B Analyt Technol Biomed Life Sci 2005; 826: 267-272.
    • (2005) J Chromatogr B Analyt Technol Biomed Life Sci , vol.826 , pp. 267-272
    • Farthing, D.1    Sica, D.A.2    Fakhry, I.3
  • 55
    • 84866611662 scopus 로고    scopus 로고
    • Routine determination of GFR in renal transplant recipients by HPLC quantification of plasma iohexol concentrations and comparison with estimated GFR
    • Castagnet S, Blasco H, Vourc'h P et al. Routine determination of GFR in renal transplant recipients by HPLC quantification of plasma iohexol concentrations and comparison with estimated GFR. J Clin Lab Anal 2012; 26: 376-383.
    • (2012) J Clin Lab Anal , vol.26 , pp. 376-383
    • Castagnet, S.1    Blasco, H.2    Vourc'H, P.3
  • 56
    • 84893125453 scopus 로고    scopus 로고
    • Measurement of glomerular filtration rate: Internal and external validations of the iohexol plasma clearance technique by HPLC
    • Luis-Lima S, Gaspari F, Porrini E et al. Measurement of glomerular filtration rate: internal and external validations of the iohexol plasma clearance technique by HPLC. Clin Chim Acta 2014; 430: 84-85.
    • (2014) Clin Chim Acta , vol.430 , pp. 84-85
    • Luis-Lima, S.1    Gaspari, F.2    Porrini, E.3
  • 57
    • 78349286780 scopus 로고    scopus 로고
    • Neutrophil gelatinase-Associated lipocalin predicts acute kidney injury in patients undergoing liver transplantation
    • Portal AJ, McPhail MJ, Bruce M et al. Neutrophil gelatinase-Associated lipocalin predicts acute kidney injury in patients undergoing liver transplantation. Liver Transpl 2010; 16: 1257-1266.
    • (2010) Liver Transpl , vol.16 , pp. 1257-1266
    • Portal, A.J.1    McPhail, M.J.2    Bruce, M.3
  • 58
    • 84899512095 scopus 로고    scopus 로고
    • Application of an isocratic methanol-based HPLC method for the determination of iohexol concentrations and glomerular filtration rate in patients with cirrhosis
    • Slack A, Tredger M, Brown N et al. Application of an isocratic methanol-based HPLC method for the determination of iohexol concentrations and glomerular filtration rate in patients with cirrhosis. Ann Clin Biochem 2014; 51: 80-88.
    • (2014) Ann Clin Biochem , vol.51 , pp. 80-88
    • Slack, A.1    Tredger, M.2    Brown, N.3
  • 59
    • 0024238897 scopus 로고
    • A simple chemical method for the quantification of the contrast agent iohexol, applicable to glomerular filtration rate measurements
    • Bäck SE, Masson P, Nilsson-Ehle P. A simple chemical method for the quantification of the contrast agent iohexol, applicable to glomerular filtration rate measurements. Scand J Clin Lab Invest 1988; 48: 825-829.
    • (1988) Scand J Clin Lab Invest , vol.48 , pp. 825-829
    • Bäck, S.E.1    Masson, P.2    Nilsson-Ehle, P.3
  • 60
    • 0025267601 scopus 로고
    • Determination of glomerular filtration rate using iohexol clearance and capillary sampling
    • Krutzen E, Bäck SE, Nilsson-Ehle P. Determination of glomerular filtration rate using iohexol clearance and capillary sampling. Scand J Clin Lab Invest 1990; 50: 279-283.
    • (1990) Scand J Clin Lab Invest , vol.50 , pp. 279-283
    • Krutzen, E.1    Bäck, S.E.2    Nilsson-Ehle, P.3
  • 61
    • 33645498168 scopus 로고    scopus 로고
    • Development of an outpatient finger-prick glomerular filtration rate procedure suitable for epidemiological studies
    • Niculescu-Duvaz I, D'Mello L, Maan Z et al. Development of an outpatient finger-prick glomerular filtration rate procedure suitable for epidemiological studies. Kidney Int 2006; 69: 1272-1275.
    • (2006) Kidney Int , vol.69 , pp. 1272-1275
    • Niculescu-Duvaz, I.1    D'Mello, L.2    Maan, Z.3
  • 62
    • 34347328111 scopus 로고    scopus 로고
    • A practical method of measuring glomerular filtration rate by iohexol clearance using dried capillary blood spots
    • Mafham MM, Niculescu-Duvaz I, Barron J et al. A practical method of measuring glomerular filtration rate by iohexol clearance using dried capillary blood spots. Nephron Clin Pract 2007; 106: c104-c112.
    • (2007) Nephron Clin Pract , vol.106 , pp. c104-c112
    • Mafham, M.M.1    Niculescu-Duvaz, I.2    Barron, J.3
  • 63
    • 84906793993 scopus 로고    scopus 로고
    • A practical method to measure GFR in people with type 1 diabetes
    • Maahs DM, Bushman L, Kerr B et al. A practical method to measure GFR in people with type 1 diabetes. J Diabetes Complications 2014; 28: 667-673.
    • (2014) J Diabetes Complications , vol.28 , pp. 667-673
    • Maahs, D.M.1    Bushman, L.2    Kerr, B.3
  • 64
    • 84943184133 scopus 로고    scopus 로고
    • Glomerular filtration rate measured by iohexol clearance: A comparison of venous samples and capillary blood spots
    • Salvador CL, Tøndel C, Mørkrid L et al. Glomerular filtration rate measured by iohexol clearance: A comparison of venous samples and capillary blood spots. Scand J Clin Lab Invest 2015; 75: 710-716.
    • (2015) Scand J Clin Lab Invest , vol.75 , pp. 710-716
    • Salvador, C.L.1    Tøndel, C.2    Mørkrid, L.3
  • 65
    • 84926643761 scopus 로고    scopus 로고
    • Estimating GFR in adult patients with hematopoietic cell transplant: Comparison of estimating equations with an iohexol reference standard
    • Hingorani S, Pao E, Schoch G et al. Estimating GFR in adult patients with hematopoietic cell transplant: comparison of estimating equations with an iohexol reference standard. Clin J Am Soc Nephrol 2015; 10: 601-610.
    • (2015) Clin J Am Soc Nephrol , vol.10 , pp. 601-610
    • Hingorani, S.1    Pao, E.2    Schoch, G.3
  • 66
    • 0023931534 scopus 로고
    • Measurement of the plasma clearance of urographic contrast media for the determination of glomerular filtration rate
    • O'Reilly PH, Jones DA, Farah NB. Measurement of the plasma clearance of urographic contrast media for the determination of glomerular filtration rate. J Urol 1988; 139: 9-11.
    • (1988) J Urol , vol.139 , pp. 9-11
    • O'Reilly, P.H.1    Jones, D.A.2    Farah, N.B.3
  • 67
    • 0027405424 scopus 로고
    • Re: Iohexol clearance for the determination of glomerular filtration rate in clinical practice: Evidence for a new gold standard
    • Bäck SE, Nilsson-Ehle P. Re: Iohexol clearance for the determination of glomerular filtration rate in clinical practice: evidence for a new gold standard. J Urol 1993; 149: 378.
    • (1993) J Urol , vol.149 , pp. 378
    • Bäck, S.E.1    Nilsson-Ehle, P.2
  • 68
    • 0025311902 scopus 로고
    • Measurement of renal function with iohexol. A comparison of iohexol, 99mTc- DTPA, and 51Cr-EDTA clearance
    • Effersöe H, Rosenkilde P, Groth S et al. Measurement of renal function with iohexol. A comparison of iohexol, 99mTc- DTPA, and 51Cr-EDTA clearance. Invest Radiol 1990; 25: 778-782.
    • (1990) Invest Radiol , vol.25 , pp. 778-782
    • Effersöe, H.1    Rosenkilde, P.2    Groth, S.3
  • 69
    • 0031959667 scopus 로고    scopus 로고
    • GFR measurement with iohexol and 51Cr-EDTA. A comparison of the two favoured GFR markers in Europe
    • Brandstrom E, Grzegorczyk A, Jacobsson L et al. GFR measurement with iohexol and 51Cr-EDTA. A comparison of the two favoured GFR markers in Europe. Nephrol Dial Transplant 1998; 13: 1176-1182.
    • (1998) Nephrol Dial Transplant , vol.13 , pp. 1176-1182
    • Brandstrom, E.1    Grzegorczyk, A.2    Jacobsson, L.3
  • 70
    • 0032725407 scopus 로고    scopus 로고
    • A comparison of the plasma disappearance of iohexol and 99mTc-DTPA for the measurement of glomerular filtration rate (GFR) in diabetes
    • Houlihan C, Jenkins M, Osicka T et al. A comparison of the plasma disappearance of iohexol and 99mTc-DTPA for the measurement of glomerular filtration rate (GFR) in diabetes. Aust N Z J Med 1999; 29: 693-700.
    • (1999) Aust N Z J Med , vol.29 , pp. 693-700
    • Houlihan, C.1    Jenkins, M.2    Osicka, T.3
  • 71
    • 44449148370 scopus 로고    scopus 로고
    • Reproducibilities and responses to food intake of GFR measured with chromium- 51-EDTA and iohexol simultaneously and independently in normal subjects
    • Bird NJ, Peters C, Michell AR et al. Reproducibilities and responses to food intake of GFR measured with chromium- 51-EDTA and iohexol simultaneously and independently in normal subjects. Nephrol Dial Transplant 2008; 23: 1902-1909.
    • (2008) Nephrol Dial Transplant , vol.23 , pp. 1902-1909
    • Bird, N.J.1    Peters, C.2    Michell, A.R.3
  • 72
    • 0031946660 scopus 로고    scopus 로고
    • Iohexol plasma clearance in determining glomerular filtration rate in diabetic patients
    • Pucci L, Bandinelli S, Penno G et al. Iohexol plasma clearance in determining glomerular filtration rate in diabetic patients. Ren Fail 1998; 20: 277-284.
    • (1998) Ren Fail , vol.20 , pp. 277-284
    • Pucci, L.1    Bandinelli, S.2    Penno, G.3
  • 73
    • 56749178901 scopus 로고    scopus 로고
    • Reproducibility of GFR measured by chromium-51-EDTA and iohexol
    • Delanaye P, Cavalier E, Froissart M et al. Reproducibility of GFR measured by chromium-51-EDTA and iohexol. Nephrol Dial Transplant 2008; 23: 4077-4078.
    • (2008) Nephrol Dial Transplant , vol.23 , pp. 4077-4078
    • Delanaye, P.1    Cavalier, E.2    Froissart, M.3
  • 74
    • 33745841279 scopus 로고    scopus 로고
    • Determination of iohexol clearance by high-performance liquid chromatography-Tandem mass spectrometry (HPLC-MS/MS)
    • Lee SY, Chun MR, Kim DJ et al. Determination of iohexol clearance by high-performance liquid chromatography-Tandem mass spectrometry (HPLC-MS/MS). J Chromatogr B Analyt Technol Biomed Life Sci 2006; 839: 124-129.
    • (2006) J Chromatogr B Analyt Technol Biomed Life Sci , vol.839 , pp. 124-129
    • Lee, S.Y.1    Chun, M.R.2    Kim, D.J.3
  • 75
    • 66449130057 scopus 로고    scopus 로고
    • Ultraperformance liquid chromatography-Tandem mass spectrometry assay for iohexol in human serum
    • Annesley TM, Clayton LT. Ultraperformance liquid chromatography-Tandem mass spectrometry assay for iohexol in human serum. Clin Chem 2009; 55: 1196-1202.
    • (2009) Clin Chem , vol.55 , pp. 1196-1202
    • Annesley, T.M.1    Clayton, L.T.2
  • 76
    • 41949086321 scopus 로고    scopus 로고
    • Development and evaluation of a liquid chromatography-mass spectrometry assay and its application for the assessment of renal function
    • Denis MC, Venne K, Lesiege D et al. Development and evaluation of a liquid chromatography-mass spectrometry assay and its application for the assessment of renal function. J Chromatogr A 2008; 1189: 410-416.
    • (2008) J Chromatogr a , vol.1189 , pp. 410-416
    • Denis, M.C.1    Venne, K.2    Lesiege, D.3
  • 77
    • 77649085009 scopus 로고    scopus 로고
    • Evaluation of sample bias for measuring plasma iohexol clearance in kidney transplantation
    • Stolz A, Hoizey G, Toupance O et al. Evaluation of sample bias for measuring plasma iohexol clearance in kidney transplantation. Transplantation 2010; 89: 440-445.
    • (2010) Transplantation , vol.89 , pp. 440-445
    • Stolz, A.1    Hoizey, G.2    Toupance, O.3
  • 78
    • 0030743611 scopus 로고    scopus 로고
    • Measurement of serum iohexol by determination of iodine with inductively coupled plasma-Atomic emission spectroscopy
    • Braselton WE, Stuart KJ, Kruger JM. Measurement of serum iohexol by determination of iodine with inductively coupled plasma-Atomic emission spectroscopy. Clin Chem 1997; 43: 1429-1435.
    • (1997) Clin Chem , vol.43 , pp. 1429-1435
    • Braselton, W.E.1    Stuart, K.J.2    Kruger, J.M.3
  • 79
    • 84965134157 scopus 로고    scopus 로고
    • Quantification of iohexol in serum by high-performance liquid chromatography-Tandem mass spectrometry (LC-MS/MS)
    • Vicente FB, Vespa G, Miller A et al. Quantification of iohexol in serum by high-performance liquid chromatography-Tandem mass spectrometry (LC-MS/MS). Methods Mol Biol 2016; 1383: 185-193.
    • (2016) Methods Mol Biol , vol.1383 , pp. 185-193
    • Vicente, F.B.1    Vespa, G.2    Miller, A.3
  • 80
    • 84856218827 scopus 로고    scopus 로고
    • Comparison of acid and enzymatic methods for inulin dosage: Analytical performances and impact on glomerular filtration rate evaluation
    • Delanaye P, Thibaudin L, Souvignet M et al. Comparison of acid and enzymatic methods for inulin dosage: Analytical performances and impact on glomerular filtration rate evaluation. Clin Chim Acta 2012; 413: 556-560.
    • (2012) Clin Chim Acta , vol.413 , pp. 556-560
    • Delanaye, P.1    Thibaudin, L.2    Souvignet, M.3
  • 81
    • 77950583188 scopus 로고    scopus 로고
    • Iothalamate quantification by tandem mass spectrometry to measure glomerular filtration rate
    • Seegmiller JC, Burns BE, Fauq AH et al. Iothalamate quantification by tandem mass spectrometry to measure glomerular filtration rate. Clin Chem 2010; 56: 568-574.
    • (2010) Clin Chem , vol.56 , pp. 568-574
    • Seegmiller, J.C.1    Burns, B.E.2    Fauq, A.H.3
  • 82
    • 84956646705 scopus 로고    scopus 로고
    • Concordance between iothalamate and iohexol plasma clearance
    • Feb 2
    • Delanaye P, Jouret F, Le Goff, C et al. Concordance between iothalamate and iohexol plasma clearance. Am J Kidney Dis 2016; Feb 2. pii:S0272-6386(16)00021-4.2016; 68:329-330.
    • (2016) Am J Kidney Dis , vol.68 , pp. 329-330
    • Delanaye, P.1    Jouret, F.2    Le Goff, C.3
  • 83
    • 84939417314 scopus 로고    scopus 로고
    • Determination of iohexol in human serum by a semi-Automated liquid chromatography tandem mass spectrometry method
    • Vicente FB, Vespa GK, Carrara F et al. Determination of iohexol in human serum by a semi-Automated liquid chromatography tandem mass spectrometry method. Clin Biochem 2015; 48: 679-685.
    • (2015) Clin Biochem , vol.48 , pp. 679-685
    • Vicente, F.B.1    Vespa, G.K.2    Carrara, F.3
  • 84
    • 0022529348 scopus 로고
    • Accuracy and reproducibility of a new contrast clearance method for the determination of glomerular filtration rate
    • O'Reilly PH, Brooman PJ, Martin PJ et al. Accuracy and reproducibility of a new contrast clearance method for the determination of glomerular filtration rate. Br Med J (Clin Res Ed) 1986; 293: 234-236.
    • (1986) Br Med J (Clin Res Ed) , vol.293 , pp. 234-236
    • O'Reilly, P.H.1    Brooman, P.J.2    Martin, P.J.3
  • 85
    • 0026630431 scopus 로고
    • Discrepancy between circadian rhythms of inulin and creatinine clearance
    • van Acker, BA, Koomen GC, Koopman MG et al. Discrepancy between circadian rhythms of inulin and creatinine clearance. J Lab Clin Med 1992; 120: 400-410.
    • (1992) J Lab Clin Med , vol.120 , pp. 400-410
    • Koomen, G.C.1    Koopman, M.G.2    Van Acker, B.A.3
  • 86
    • 0025144722 scopus 로고
    • Effect of food and activity on the reproducibility of isotopic GFR estimation
    • Wilkinson J, Fleming JS, Waller DG. Effect of food and activity on the reproducibility of isotopic GFR estimation. Nucl Med Commun 1990; 11: 697-700.
    • (1990) Nucl Med Commun , vol.11 , pp. 697-700
    • Wilkinson, J.1    Fleming, J.S.2    Waller, D.G.3
  • 87
    • 0024393876 scopus 로고
    • Circadian rhythm of glomerular filtration rate in normal individuals
    • Koopman MG, Koomen GC, Krediet RT et al. Circadian rhythm of glomerular filtration rate in normal individuals. Clin Sci (Lond) 1989; 77: 105-111.
    • (1989) Clin Sci (Lond) , vol.77 , pp. 105-111
    • Koopman, M.G.1    Koomen, G.C.2    Krediet, R.T.3
  • 88
    • 0025172050 scopus 로고
    • Utility of radioisotopic filtration markers in chronic renal insufficiency: Simultaneous comparison of 125I-iothalamate, 169Yb-DTPA, 99mTc- DTPA, and inulin
    • The Modification of Diet in Renal Disease Study
    • Perrone RD, Steinman TI, Beck GJ et al. Utility of radioisotopic filtration markers in chronic renal insufficiency: simultaneous comparison of 125I-iothalamate, 169Yb-DTPA, 99mTc- DTPA, and inulin. The Modification of Diet in Renal Disease Study. Am J Kidney Dis 1990; 16: 224-235.
    • (1990) Am J Kidney Dis , vol.16 , pp. 224-235
    • Perrone, R.D.1    Steinman, T.I.2    Beck, G.J.3
  • 89
    • 0017291247 scopus 로고
    • Selection of routine method for determination of glomerular filtration rate in adult patients
    • Brochner-Mortensen J, Rodbro P. Selection of routine method for determination of glomerular filtration rate in adult patients. Scand J Clin Lab Invest 1976; 36: 35-43.
    • (1976) Scand J Clin Lab Invest , vol.36 , pp. 35-43
    • Brochner-Mortensen, J.1    Rodbro, P.2
  • 90
    • 76549236600 scopus 로고
    • Age changes in glomerular filtration rate, effective renal plasma flow, and tubular excretory capacity in adult males
    • Davies DF, Shock NW. Age changes in glomerular filtration rate, effective renal plasma flow, and tubular excretory capacity in adult males. J Clin Invest 1950; 29: 496-507.
    • (1950) J Clin Invest , vol.29 , pp. 496-507
    • Davies, D.F.1    Shock, N.W.2
  • 91
    • 0019870539 scopus 로고
    • On the necessity of strict bed rest during determination of 51Cr-EDTA clearance
    • Brauner L, Westling H. On the necessity of strict bed rest during determination of 51Cr-EDTA clearance. Clin Physiol Funct Imaging 1981; 1: 175-180.
    • (1981) Clin Physiol Funct Imaging , vol.1 , pp. 175-180
    • Brauner, L.1    Westling, H.2
  • 92
    • 0029067059 scopus 로고
    • Measurement of glomerular filtration rate by single-injection, single-sample techniques, using 51Cr-EDTA or iohexol
    • Rydström M, Tengstrom B, Cederquist I et al. Measurement of glomerular filtration rate by single-injection, single-sample techniques, using 51Cr-EDTA or iohexol. Scand J Urol Nephrol 1995; 29: 135-139.
    • (1995) Scand J Urol Nephrol , vol.29 , pp. 135-139
    • Rydström, M.1    Tengstrom, B.2    Cederquist, I.3
  • 93
    • 0035079680 scopus 로고    scopus 로고
    • Iohexol as a marker of glomerular filtration rate in patients with diabetes: Comparison of multiple and simplified sampling protocols
    • Pucci L, Bandinelli S, Pilo M et al. Iohexol as a marker of glomerular filtration rate in patients with diabetes: comparison of multiple and simplified sampling protocols. Diabet Med 2001; 18: 116-120.
    • (2001) Diabet Med , vol.18 , pp. 116-120
    • Pucci, L.1    Bandinelli, S.2    Pilo, M.3
  • 94
    • 0037382244 scopus 로고    scopus 로고
    • Ambulatory GFR measurement with cold iothalamate in adults with chronic kidney disease
    • Agarwal R. Ambulatory GFR measurement with cold iothalamate in adults with chronic kidney disease. Am J Kidney Dis 2003; 41: 752-759.
    • (2003) Am J Kidney Dis , vol.41 , pp. 752-759
    • Agarwal, R.1
  • 95
    • 0347362493 scopus 로고    scopus 로고
    • Assessing renal graft function in clinical trials: Can tests predicting glomerular filtration rate substitute for a reference method?
    • Mariat C, Alamartine E, Barthelemy JC et al. Assessing renal graft function in clinical trials: can tests predicting glomerular filtration rate substitute for a reference method? Kidney Int 2004; 65: 289-297.
    • (2004) Kidney Int , vol.65 , pp. 289-297
    • Mariat, C.1    Alamartine, E.2    Barthelemy, J.C.3
  • 96
    • 20544448298 scopus 로고    scopus 로고
    • Predictive performance of the modification of diet in renal disease and Cockcroft- Gault equations for estimating renal function
    • Froissart M, Rossert J, Jacquot C et al. Predictive performance of the modification of diet in renal disease and Cockcroft- Gault equations for estimating renal function. J Am Soc Nephrol 2005; 16: 763-773.
    • (2005) J Am Soc Nephrol , vol.16 , pp. 763-773
    • Froissart, M.1    Rossert, J.2    Jacquot, C.3
  • 97
    • 59449102395 scopus 로고    scopus 로고
    • Long-Term consequences of kidney donation
    • Ibrahim HN, Foley R, Tan L et al. Long-Term consequences of kidney donation. N Engl J Med 2009; 360: 459-469.
    • (2009) N Engl J Med , vol.360 , pp. 459-469
    • Ibrahim, H.N.1    Foley, R.2    Tan, L.3
  • 98
    • 34548030023 scopus 로고    scopus 로고
    • Validity of simplified protocols to estimate glomerular filtration rate using iohexol clearance
    • James TJ, Lewis AV, Tan GD et al. Validity of simplified protocols to estimate glomerular filtration rate using iohexol clearance. Ann Clin Biochem 2007; 44: 369-376.
    • (2007) Ann Clin Biochem , vol.44 , pp. 369-376
    • James, T.J.1    Lewis, A.V.2    Tan, G.D.3
  • 99
    • 84992482378 scopus 로고    scopus 로고
    • Elevated blood pressure is not associated with accelerated glomerular filtration rate decline in the general non-diabetic middle-Aged population
    • Eriksen BO, Stefansson VT, Jenssen TG et al. Elevated blood pressure is not associated with accelerated glomerular filtration rate decline in the general non-diabetic middle-Aged population. Kidney Int 2016; 90: 404-410.
    • (2016) Kidney Int , vol.90 , pp. 404-410
    • Eriksen, B.O.1    Stefansson, V.T.2    Jenssen, T.G.3
  • 100
    • 0026045977 scopus 로고
    • Iohexol clearance for the determination of glomerular filtration rate in clinical practice: Evidence for a new gold standard
    • Brown SC, O'Reilly PH. Iohexol clearance for the determination of glomerular filtration rate in clinical practice: evidence for a new gold standard. J Urol 1991; 146: 675-679.
    • (1991) J Urol , vol.146 , pp. 675-679
    • Brown, S.C.1    O'Reilly, P.H.2
  • 101
    • 42449155110 scopus 로고    scopus 로고
    • Determining 'true' glomerular filtration rate in healthy adults using infusion of inulin and comparing it with values obtained using other clearance techniques or prediction equations
    • Sterner G, Frennby B, Mansson S et al. Determining 'true' glomerular filtration rate in healthy adults using infusion of inulin and comparing it with values obtained using other clearance techniques or prediction equations. Scand J Urol Nephrol 2008; 42: 278-285.
    • (2008) Scand J Urol Nephrol , vol.42 , pp. 278-285
    • Sterner, G.1    Frennby, B.2    Mansson, S.3
  • 102
    • 0024310070 scopus 로고
    • Comparative evaluation of urographic contrast media, inulin, and 99mTc-DTPA clearance methods for determination of glomerular filtration rate in clinical transplantation
    • Lewis R, Kerr N, Van Buren, C et al. Comparative evaluation of urographic contrast media, inulin, and 99mTc-DTPA clearance methods for determination of glomerular filtration rate in clinical transplantation. Transplantation 1989; 48: 790-796.
    • (1989) Transplantation , vol.48 , pp. 790-796
    • Lewis, R.1    Kerr, N.2    Van Buren, C.3
  • 103
    • 0028222706 scopus 로고
    • Comparative evaluation of iohexol and inulin clearance for glomerular filtration rate determinations
    • Lindblad HG, Berg UB. Comparative evaluation of iohexol and inulin clearance for glomerular filtration rate determinations. Acta Paediatr 1994; 83: 418-422.
    • (1994) Acta Paediatr , vol.83 , pp. 418-422
    • Lindblad, H.G.1    Berg, U.B.2
  • 104
    • 0034883998 scopus 로고    scopus 로고
    • Plasma clearance of iodine contrast media as a measure of glomerular filtration rate in critically ill patients
    • Erley CM, Bader BD, Berger ED et al. Plasma clearance of iodine contrast media as a measure of glomerular filtration rate in critically ill patients. Crit Care Med 2001; 29: 1544-1550.
    • (2001) Crit Care Med , vol.29 , pp. 1544-1550
    • Erley, C.M.1    Bader, B.D.2    Berger, E.D.3
  • 105
    • 78650523141 scopus 로고    scopus 로고
    • Comparison of plasma clearance of iohexol and urinary clearance of inulin for measurement of GFR in children
    • Berg UB, Bäck R, Celsi G et al. Comparison of plasma clearance of iohexol and urinary clearance of inulin for measurement of GFR in children. Am J Kidney Dis 2011; 57: 55-61.
    • (2011) Am J Kidney Dis , vol.57 , pp. 55-61
    • Berg, U.B.1    Bäck, R.2    Celsi, G.3
  • 106
    • 0026673140 scopus 로고
    • The estimate of glomerular filtration rate during urography. Acceptability of a nonionic contrast medium as a marker of renal function
    • Brown SC, O'Reilly PH. The estimate of glomerular filtration rate during urography. Acceptability of a nonionic contrast medium as a marker of renal function. Invest Radiol 1992; 27: 774-778.
    • (1992) Invest Radiol , vol.27 , pp. 774-778
    • Brown, S.C.1    O'Reilly, P.H.2
  • 107
    • 0344395541 scopus 로고    scopus 로고
    • Prediction of GFR in liver transplant candidates
    • Skluzacek PA, Szewc RG, Nolan CR III et al. Prediction of GFR in liver transplant candidates. Am J Kidney Dis 2003; 42: 1169-1176.
    • (2003) Am J Kidney Dis , vol.42 , pp. 1169-1176
    • Skluzacek, P.A.1    Szewc, R.G.2    Nolan, C.R.3
  • 108
    • 0024262637 scopus 로고
    • Contrast media and glomerular filtration: Dose dependence of clearance for three agents
    • Bäck SE, Krutzen E, Nilsson-Ehle P. Contrast media and glomerular filtration: dose dependence of clearance for three agents. J Pharm Sci 1988; 77: 765-767.
    • (1988) J Pharm Sci , vol.77 , pp. 765-767
    • Bäck, S.E.1    Krutzen, E.2    Nilsson-Ehle, P.3
  • 109
    • 0025826993 scopus 로고
    • Glomerular filtration rate: A comparison between Cr-EDTA clearance and a single sample technique with a non-ionic contrast agent
    • Eriksson CG, Kallner A. Glomerular filtration rate: A comparison between Cr-EDTA clearance and a single sample technique with a non-ionic contrast agent. Clin Biochem 1991; 24: 261-264.
    • (1991) Clin Biochem , vol.24 , pp. 261-264
    • Eriksson, C.G.1    Kallner, A.2
  • 110
    • 0020955393 scopus 로고
    • A method for the calculation of renal clearance based on a single plasma sample
    • Jacobsson L. A method for the calculation of renal clearance based on a single plasma sample. Clin Physiol 1983; 3: 297-305.
    • (1983) Clin Physiol , vol.3 , pp. 297-305
    • Jacobsson, L.1
  • 111
    • 0026356306 scopus 로고
    • The clearance of iohexol as a measure of the glomerular filtration rate in children with chronic renal failure
    • Stake G, Monn E, Rootwelt K et al. The clearance of iohexol as a measure of the glomerular filtration rate in children with chronic renal failure. Scand J Clin Lab Invest 1991; 51: 729-734.
    • (1991) Scand J Clin Lab Invest , vol.51 , pp. 729-734
    • Stake, G.1    Monn, E.2    Rootwelt, K.3
  • 112
    • 0019153477 scopus 로고
    • Determination of glomerular filtration rate (GFR) by analysis of capillary blood after single shot injection of 99mTc-DTPA. A comparison with simultaneous 125I-iothalamate GFR estimation showing equal GFR but difference in distribution volume
    • Rootwelt K, Falch D, Sjokvist R. Determination of glomerular filtration rate (GFR) by analysis of capillary blood after single shot injection of 99mTc-DTPA. A comparison with simultaneous 125I-iothalamate GFR estimation showing equal GFR but difference in distribution volume. Eur J Nucl Med 1980; 5: 97-102.
    • (1980) Eur J Nucl Med , vol.5 , pp. 97-102
    • Rootwelt, K.1    Falch, D.2    Sjokvist, R.3
  • 113
    • 0028467646 scopus 로고
    • Simultaneous urography and determination of glomerular filtration rate. A comparison of total plasma clearances of iohexol and 51Cr-EDTA in plegic patients
    • Lundqvist S, Hietala SO, Berglund C et al. Simultaneous urography and determination of glomerular filtration rate. A comparison of total plasma clearances of iohexol and 51Cr-EDTA in plegic patients. Acta Radiol 1994; 35: 391-395.
    • (1994) Acta Radiol , vol.35 , pp. 391-395
    • Lundqvist, S.1    Hietala, S.O.2    Berglund, C.3
  • 114
    • 0030640438 scopus 로고    scopus 로고
    • Evaluation of single sample clearance calculations in 902 patients. A comparison of multiple and single sample techniques
    • Lundqvist S, Hietala SO, Groth S et al. Evaluation of single sample clearance calculations in 902 patients. A comparison of multiple and single sample techniques. Acta Radiol 1997; 38: 68-72.
    • (1997) Acta Radiol , vol.38 , pp. 68-72
    • Lundqvist, S.1    Hietala, S.O.2    Groth, S.3
  • 115
    • 67650369686 scopus 로고    scopus 로고
    • Comparison of GFR measurements assessed from single versus multiple samples
    • Bird NJ, Peters C, Michell AR et al. Comparison of GFR measurements assessed from single versus multiple samples. Am J Kidney Dis 2009; 54: 278-288.
    • (2009) Am J Kidney Dis , vol.54 , pp. 278-288
    • Bird, N.J.1    Peters, C.2    Michell, A.R.3
  • 116
    • 0015429594 scopus 로고
    • A simple method for the determination of glomerular filtration rate
    • Brochner-Mortensen J. A simple method for the determination of glomerular filtration rate. Scand J Clin Lab Invest 1972; 30: 271-274.
    • (1972) Scand J Clin Lab Invest , vol.30 , pp. 271-274
    • Brochner-Mortensen, J.1
  • 117
    • 59249085632 scopus 로고    scopus 로고
    • Validation of plasma clearance of 51Cr-EDTA in adult renal transplant recipients: Comparison with inulin renal clearance
    • Medeiros FS, Sapienza MT, Prado ES et al. Validation of plasma clearance of 51Cr-EDTA in adult renal transplant recipients: comparison with inulin renal clearance. Transpl Int 2009; 22: 323-331.
    • (2009) Transpl Int , vol.22 , pp. 323-331
    • Medeiros, F.S.1    Sapienza, M.T.2    Prado, E.S.3
  • 118
    • 84942292886 scopus 로고    scopus 로고
    • Plasma iohexol clearance for assessing residual kidney function in dialysis patients
    • Shafi T, Levey AS, Inker LA et al. Plasma iohexol clearance for assessing residual kidney function in dialysis patients. Am J Kidney Dis 2015; 66: 728-730.
    • (2015) Am J Kidney Dis , vol.66 , pp. 728-730
    • Shafi, T.1    Levey, A.S.2    Inker, L.A.3
  • 119
    • 0036484461 scopus 로고    scopus 로고
    • Contrast media as markers of GFR
    • Frennby B, Sterner G. Contrast media as markers of GFR. Eur Radiol 2002; 12: 475-484.
    • (2002) Eur Radiol , vol.12 , pp. 475-484
    • Frennby, B.1    Sterner, G.2
  • 121
    • 0017053738 scopus 로고
    • Optimum time of blood sampling for determination of glomerular filtration rate by single-injection [51Cr]EDTA plasma clearance
    • Brochner-Mortensen J, Rodbro P. Optimum time of blood sampling for determination of glomerular filtration rate by single-injection [51Cr]EDTA plasma clearance. Scand J Clin Lab Invest 1976; 36: 795-800.
    • (1976) Scand J Clin Lab Invest , vol.36 , pp. 795-800
    • Brochner-Mortensen, J.1    Rodbro, P.2
  • 122
    • 0031742626 scopus 로고    scopus 로고
    • Application of newer clearance techniques for the determination of glomerular filtration rate
    • Gaspari F, Perico N, Remuzzi G. Application of newer clearance techniques for the determination of glomerular filtration rate. Curr Opin Nephrol Hypertens 1998; 7: 675-680.
    • (1998) Curr Opin Nephrol Hypertens , vol.7 , pp. 675-680
    • Gaspari, F.1    Perico, N.2    Remuzzi, G.3
  • 123
    • 0030024990 scopus 로고    scopus 로고
    • Plasma clearance rate of 51Cr-EDTA provides a precise and convenient technique for measurement of glomerular filtration rate in diabetic humans
    • Sambataro M, Thomaseth K, Pacini G et al. Plasma clearance rate of 51Cr-EDTA provides a precise and convenient technique for measurement of glomerular filtration rate in diabetic humans. J Am Soc Nephrol 1996; 7: 118-127.
    • (1996) J Am Soc Nephrol , vol.7 , pp. 118-127
    • Sambataro, M.1    Thomaseth, K.2    Pacini, G.3
  • 124
    • 80051556386 scopus 로고    scopus 로고
    • Systematic shifts in cystatin C between 2006 and 2010
    • Maahs DM, Jalal D, McFann K et al. Systematic shifts in cystatin C between 2006 and 2010. Clin J Am Soc Nephrol 2011; 6: 1952-1955.
    • (2011) Clin J Am Soc Nephrol , vol.6 , pp. 1952-1955
    • Maahs, D.M.1    Jalal, D.2    McFann, K.3
  • 125
    • 85006512140 scopus 로고    scopus 로고
    • The clearance concept with special reference to determination of glomerular filtration rate in patients with fluid retention
    • Henriksen UL, Henriksen JH. The clearance concept with special reference to determination of glomerular filtration rate in patients with fluid retention. Clin Physiol Funct Imaging 2015; 35: 7-16.
    • (2015) Clin Physiol Funct Imaging , vol.35 , pp. 7-16
    • Henriksen, U.L.1    Henriksen, J.H.2
  • 126
    • 84886792613 scopus 로고    scopus 로고
    • Effect of longacting somatostatin analogue on kidney and cyst growth in autosomal dominant polycystic kidney disease (ALADIN): A randomised, placebo-controlled, multicentre trial
    • Caroli A, Perico N, Perna A et al. Effect of longacting somatostatin analogue on kidney and cyst growth in autosomal dominant polycystic kidney disease (ALADIN): A randomised, placebo-controlled, multicentre trial. Lancet 2013; 382: 1485-1495.
    • (2013) Lancet , vol.382 , pp. 1485-1495
    • Caroli, A.1    Perico, N.2    Perna, A.3
  • 127
    • 15844414184 scopus 로고    scopus 로고
    • Blood-pressure control for renoprotection in patients with non-diabetic chronic renal disease (REIN-2): Multicentre, randomised controlled trial
    • Ruggenenti P, Perna A, Loriga G et al. Blood-pressure control for renoprotection in patients with non-diabetic chronic renal disease (REIN-2): multicentre, randomised controlled trial. Lancet 2005; 365: 939-946.
    • (2005) Lancet , vol.365 , pp. 939-946
    • Ruggenenti, P.1    Perna, A.2    Loriga, G.3
  • 129
    • 83155180436 scopus 로고    scopus 로고
    • Effects of manidipine and delapril in hypertensive patients with type 2 diabetes mellitus: The delapril and manidipine for nephroprotection in diabetes (DEMAND) randomized clinical trial
    • Ruggenenti P, Lauria G, Iliev IP et al. Effects of manidipine and delapril in hypertensive patients with type 2 diabetes mellitus: The delapril and manidipine for nephroprotection in diabetes (DEMAND) randomized clinical trial. Hypertension 2011; 58: 776-783.
    • (2011) Hypertension , vol.58 , pp. 776-783
    • Ruggenenti, P.1    Lauria, G.2    Iliev, I.P.3
  • 130
    • 84939613635 scopus 로고    scopus 로고
    • Iohexol plasma clearance measurement in older adults with chronic kidney diseasesampling time matters
    • Ebert N, Loesment A, Martus P et al. Iohexol plasma clearance measurement in older adults with chronic kidney diseasesampling time matters. Nephrol Dial Transplant 2015; 30: 1307-1314.
    • (2015) Nephrol Dial Transplant , vol.30 , pp. 1307-1314
    • Ebert, N.1    Loesment, A.2    Martus, P.3
  • 131
    • 80052261671 scopus 로고    scopus 로고
    • Universal GFR determination based on two time points during plasma iohexol disappearance
    • Ng DK, Schwartz GJ, Jacobson LP et al. Universal GFR determination based on two time points during plasma iohexol disappearance. Kidney Int 2011; 80: 423-430.
    • (2011) Kidney Int , vol.80 , pp. 423-430
    • Ng, D.K.1    Schwartz, G.J.2    Jacobson, L.P.3
  • 132
    • 0033013390 scopus 로고    scopus 로고
    • Howto assess glomerular function and damage in humans
    • Rahn KH, Heidenreich S, Brückner D. Howto assess glomerular function and damage in humans. J Hypertens 1999; 17: 309-317.
    • (1999) J Hypertens , vol.17 , pp. 309-317
    • Rahn, K.H.1    Heidenreich, S.2    Brückner, D.3
  • 133
    • 0014558852 scopus 로고
    • Glomerular filtration rate measurement in man by the single injection methods using 51Cr-EDTA
    • Chantler C, Garnett ES, Parsons V et al. Glomerular filtration rate measurement in man by the single injection methods using 51Cr-EDTA. Clin Sci 1969; 37: 169-180.
    • (1969) Clin Sci , vol.37 , pp. 169-180
    • Chantler, C.1    Garnett, E.S.2    Parsons, V.3
  • 134
    • 67649784548 scopus 로고    scopus 로고
    • Reassessment of a classical single injection 51Cr-EDTA clearance method for determination of renal function in children and adults. Part I: Analytically correct relationship between total and one-pool clearance
    • Jodal L, Brochner-Mortensen J. Reassessment of a classical single injection 51Cr-EDTA clearance method for determination of renal function in children and adults. Part I: Analytically correct relationship between total and one-pool clearance. Scand J Clin Lab Invest 2009; 69: 305-313.
    • (2009) Scand J Clin Lab Invest , vol.69 , pp. 305-313
    • Jodal, L.1    Brochner-Mortensen, J.2
  • 135
    • 72949114067 scopus 로고    scopus 로고
    • Optimizing iohexol plasma disappearance curves to measure the glomerular filtration rate in children with chronic kidney disease
    • Schwartz GJ, Abraham AG, Furth SL et al. Optimizing iohexol plasma disappearance curves to measure the glomerular filtration rate in children with chronic kidney disease. Kidney Int 2010; 77: 65-71.
    • (2010) Kidney Int , vol.77 , pp. 65-71
    • Schwartz, G.J.1    Abraham, A.G.2    Furth, S.L.3
  • 136
    • 0034184716 scopus 로고    scopus 로고
    • How good is the slope on the second exponential for estimating 51Cr-EDTA renal clearance? A Monte Carlo simulation
    • De Sadeleer, C, Piepsz A, Ham HR. How good is the slope on the second exponential for estimating 51Cr-EDTA renal clearance? A Monte Carlo simulation. Nucl Med Commun 2000; 21: 455-458.
    • (2000) Nucl Med Commun , vol.21 , pp. 455-458
    • Piepsz, A.1    Ham, H.R.2    De Sadeleer, C.3
  • 137
    • 34247627562 scopus 로고    scopus 로고
    • An improved equation for correcting slope-intercept measurements of glomerular filtration rate for the single exponential approximation
    • Fleming JS. An improved equation for correcting slope-intercept measurements of glomerular filtration rate for the single exponential approximation. Nucl Med Commun 2007; 28: 315-320.
    • (2007) Nucl Med Commun , vol.28 , pp. 315-320
    • Fleming, J.S.1
  • 138
    • 0015106267 scopus 로고
    • Effective renal plasma flow: Estimation from theoretical volumes of distribution of intravenously injected 131-I orthoiodohippurate
    • Tauxe WN, Maher FT, Taylor WF. Effective renal plasma flow: estimation from theoretical volumes of distribution of intravenously injected 131-I orthoiodohippurate. Mayo Clin Proc 1971; 46: 524-531.
    • (1971) Mayo Clin Proc , vol.46 , pp. 524-531
    • Tauxe, W.N.1    Maher, F.T.2    Taylor, W.F.3
  • 139
    • 0019730910 scopus 로고
    • 51Cr-EDTA clearance determined by one plasma sample
    • Groth S, Aasted M. 51Cr-EDTA clearance determined by one plasma sample. Clin Physiol 1981; 1: 417-425.
    • (1981) Clin Physiol , vol.1 , pp. 417-425
    • Groth, S.1    Aasted, M.2
  • 140
    • 13944254079 scopus 로고    scopus 로고
    • Guidelines for the measurement of glomerular filtration rate using plasma sampling
    • Piepsz A, Ham R, De Sadeleer, C. Guidelines for the measurement of glomerular filtration rate using plasma sampling. Nucl Med Commun 2005; 26: 175-176.
    • (2005) Nucl Med Commun , vol.26 , pp. 175-176
    • Piepsz, A.1    Ham, R.2    De Sadeleer, C.3
  • 141
    • 0022478455 scopus 로고
    • Determination of 51Cr- EDTA clearance in infants by a single capillary blood sample
    • Fjeldborg P, Brochner-Mortensen J. Determination of 51Cr- EDTA clearance in infants by a single capillary blood sample. Scand J Clin Lab Invest 1986; 46: 335-340.
    • (1986) Scand J Clin Lab Invest , vol.46 , pp. 335-340
    • Fjeldborg, P.1    Brochner-Mortensen, J.2
  • 142
    • 0024521836 scopus 로고
    • Measurement of glomerular filtration rate in adults: Accuracy of five single-sample plasma clearance methods
    • Rehling M, Rabol A. Measurement of glomerular filtration rate in adults: Accuracy of five single-sample plasma clearance methods. Clin Physiol 1989; 9: 171-182.
    • (1989) Clin Physiol , vol.9 , pp. 171-182
    • Rehling, M.1    Rabol, A.2
  • 143
    • 0024471558 scopus 로고
    • 51Cr-EDTA plasma clearance in severe renal failure determined by one plasma sample
    • Kamper AL, Nielsen SL. 51Cr-EDTA plasma clearance in severe renal failure determined by one plasma sample. Scand J Clin Lab Invest 1989; 49: 555-559.
    • (1989) Scand J Clin Lab Invest , vol.49 , pp. 555-559
    • Kamper, A.L.1    Nielsen, S.L.2
  • 144
    • 0024854733 scopus 로고
    • Determination of 51Cr-EDTAclearance between 15 and 40 ml/min/1.73 m2 by a single plasma sample
    • Groth S, Aasted M. Determination of 51Cr-EDTAclearance between 15 and 40 ml/min/1.73 m2 by a single plasma sample. Scand J Clin Lab Invest 1989; 49: 711-717.
    • (1989) Scand J Clin Lab Invest , vol.49 , pp. 711-717
    • Groth, S.1    Aasted, M.2
  • 145
    • 0032424281 scopus 로고    scopus 로고
    • Chromium-51-EDTA clearance in adults with a single-plasma sample
    • Martensson J, Groth S, Rehling M et al. Chromium-51-EDTA clearance in adults with a single-plasma sample. J Nucl Med 1998; 39: 2131-2137.
    • (1998) J Nucl Med , vol.39 , pp. 2131-2137
    • Martensson, J.1    Groth, S.2    Rehling, M.3
  • 146
    • 0022189592 scopus 로고
    • Measurement of glomerular filtration rate: Single injection plasma clearance method without urine collection
    • Russell CD, Bischoff PG, Kontzen FN et al. Measurement of glomerular filtration rate: single injection plasma clearance method without urine collection. J Nucl Med 1985; 26: 1243-1247.
    • (1985) J Nucl Med , vol.26 , pp. 1243-1247
    • Russell, C.D.1    Bischoff, P.G.2    Kontzen, F.N.3
  • 147
    • 0026494261 scopus 로고
    • A simple method of estimating glomerular filtration rate
    • Watson WS. A simple method of estimating glomerular filtration rate. Eur J Nucl Med 1992; 19: 827.
    • (1992) Eur J Nucl Med , vol.19 , pp. 827
    • Watson, W.S.1
  • 148
    • 36749069523 scopus 로고    scopus 로고
    • GFR determination in adults with a singlesample iohexol plasma clearance method based on the mean sojourn time
    • Gref M, Karp K. GFR determination in adults with a singlesample iohexol plasma clearance method based on the mean sojourn time. Nephrol Dial Transplant 2007; 22: 3166-3173.
    • (2007) Nephrol Dial Transplant , vol.22 , pp. 3166-3173
    • Gref, M.1    Karp, K.2
  • 149
    • 0029974497 scopus 로고    scopus 로고
    • Iohexol clearance for GFR-determination in renal failure-single or multiple plasma sampling?
    • Sterner G, Frennby B, Hultberg B et al. Iohexol clearance for GFR-determination in renal failure-single or multiple plasma sampling? Nephrol Dial Transplant 1996; 11: 521-525.
    • (1996) Nephrol Dial Transplant , vol.11 , pp. 521-525
    • Sterner, G.1    Frennby, B.2    Hultberg, B.3
  • 150
    • 0030378024 scopus 로고    scopus 로고
    • Glomerular filtration rate determined from a single plasma sample after intravenous iohexol injection: Is it reliable?
    • Gaspari F, Guerini E, Perico N et al. Glomerular filtration rate determined from a single plasma sample after intravenous iohexol injection: is it reliable? J Am Soc Nephrol 1996; 7: 2689-2693.
    • (1996) J Am Soc Nephrol , vol.7 , pp. 2689-2693
    • Gaspari, F.1    Guerini, E.2    Perico, N.3
  • 151
    • 0025972559 scopus 로고
    • Estimation of glomerular filtration rate from low-dose injection of iohexol and a single blood sample
    • Thomsen HS, Hvid-Jacobsen K. Estimation of glomerular filtration rate from low-dose injection of iohexol and a single blood sample. Invest Radiol 1991; 26: 332-336.
    • (1991) Invest Radiol , vol.26 , pp. 332-336
    • Thomsen, H.S.1    Hvid-Jacobsen, K.2
  • 152
    • 0025737014 scopus 로고
    • A single plasma sample method for estimation of the glomerular filtration rate in infants and children using iohexol, II: Establishment of the optimal plasma sampling time and a comparison with the 99Tcm-DTPA method
    • Stake G, Monn E, Rootwelt K et al. A single plasma sample method for estimation of the glomerular filtration rate in infants and children using iohexol, II: establishment of the optimal plasma sampling time and a comparison with the 99Tcm-DTPA method. Scand J Clin Lab Invest 1991; 51: 343-348.
    • (1991) Scand J Clin Lab Invest , vol.51 , pp. 343-348
    • Stake, G.1    Monn, E.2    Rootwelt, K.3
  • 153
    • 0030031081 scopus 로고    scopus 로고
    • Measurement of glomerular filtration rate using nonradioactive iohexol: Comparison of two one-compartment models
    • Rocco MV, Buckalew VM Jr, Moore LC et al. Measurement of glomerular filtration rate using nonradioactive iohexol: comparison of two one-compartment models. Am J Nephrol 1996; 16: 138-143.
    • (1996) Am J Nephrol , vol.16 , pp. 138-143
    • Rocco, M.V.1    Buckalew, V.M.2    Moore, L.C.3
  • 154
    • 0031721935 scopus 로고    scopus 로고
    • Glomerular filtration rate determination in diabetic patients using iohexol clearance-comparison of single and multiple plasma sampling methods
    • Chowdhury TA, Dyer PH, Bartlett WA et al. Glomerular filtration rate determination in diabetic patients using iohexol clearance-comparison of single and multiple plasma sampling methods. Clin Chim Acta 1998; 277: 153-158.
    • (1998) Clin Chim Acta , vol.277 , pp. 153-158
    • Chowdhury, T.A.1    Dyer, P.H.2    Bartlett, W.A.3
  • 155
    • 0023223795 scopus 로고
    • Comparison of measurement of glomerular filtration rate by single sample, plasma disappearance slope/intercept and other methods
    • Tepe PG, Tauxe WN, Bagchi A et al. Comparison of measurement of glomerular filtration rate by single sample, plasma disappearance slope/intercept and other methods. Eur J Nucl Med 1987; 13: 28-31.
    • (1987) Eur J Nucl Med , vol.13 , pp. 28-31
    • Tepe, P.G.1    Tauxe, W.N.2    Bagchi, A.3
  • 156
    • 37349073771 scopus 로고    scopus 로고
    • Comparison of glomerular filtration rate measurements with the two plasma sample and single plasma sample, gamma camera Gates, creatinine clearance, and prediction equation methods in potential kidney donors with normal renal function
    • Aydin F, Gungor F, Cengiz AK et al. Comparison of glomerular filtration rate measurements with the two plasma sample and single plasma sample, gamma camera Gates, creatinine clearance, and prediction equation methods in potential kidney donors with normal renal function. Nucl Med Commun 2008; 29: 157-165.
    • (2008) Nucl Med Commun , vol.29 , pp. 157-165
    • Aydin, F.1    Gungor, F.2    Cengiz, A.K.3
  • 157
    • 0033943339 scopus 로고    scopus 로고
    • Reappraisal of singlesample and gamma camera methods for determination of the glomerular filtration rate with 99mTc-DTPA
    • Itoh K, Tsushima S, Tsukamoto E et al. Reappraisal of singlesample and gamma camera methods for determination of the glomerular filtration rate with 99mTc-DTPA. Ann Nucl Med 2000; 14: 143-150.
    • (2000) Ann Nucl Med , vol.14 , pp. 143-150
    • Itoh, K.1    Tsushima, S.2    Tsukamoto, E.3
  • 158
    • 0022255180 scopus 로고
    • Comparative assessment of techniques for estimation of glomerular filtration rate with 99mTc-DTPA
    • Fawdry RM, Gruenewald SM, Collins LT et al. Comparative assessment of techniques for estimation of glomerular filtration rate with 99mTc-DTPA. Eur J Nucl Med 1985; 11: 7-12.
    • (1985) Eur J Nucl Med , vol.11 , pp. 7-12
    • Fawdry, R.M.1    Gruenewald, S.M.2    Collins, L.T.3
  • 159
    • 81255189117 scopus 로고    scopus 로고
    • Reliability of (5)(1) Cr-EDTA plasma and urinary clearance as a measure of residual renal function in dialysis patients
    • Kjaergaard KD, Jensen JD, Jespersen B et al. Reliability of (5)(1) Cr-EDTA plasma and urinary clearance as a measure of residual renal function in dialysis patients. Scand J Clin Lab Invest 2011; 71: 663-669.
    • (2011) Scand J Clin Lab Invest , vol.71 , pp. 663-669
    • Kjaergaard, K.D.1    Jensen, J.D.2    Jespersen, B.3
  • 160
    • 0025315514 scopus 로고
    • Methods for measuring GFR with technetium-99m-DTPA: An analysis of several common methods
    • Mulligan JS, Blue PW, Hasbargen JA. Methods for measuring GFR with technetium-99m-DTPA: An analysis of several common methods. J Nucl Med 1990; 31: 1211-1219.
    • (1990) J Nucl Med , vol.31 , pp. 1211-1219
    • Mulligan, J.S.1    Blue, P.W.2    Hasbargen, J.A.3
  • 161
    • 0030810806 scopus 로고    scopus 로고
    • Estimation of glomerular filtration rate with 99Tc(m)-DTPA: A comparative assessment of simplified methods
    • Galli G, Rufini V, Vellante C et al. Estimation of glomerular filtration rate with 99Tc(m)-DTPA: A comparative assessment of simplified methods. Nucl Med Commun 1997; 18: 634-641.
    • (1997) Nucl Med Commun , vol.18 , pp. 634-641
    • Galli, G.1    Rufini, V.2    Vellante, C.3
  • 162
    • 4143112303 scopus 로고    scopus 로고
    • Guidelines for the measurement of glomerular filtration rate using plasma sampling
    • Fleming JS, Zivanovic MA, Blake GM et al. Guidelines for the measurement of glomerular filtration rate using plasma sampling. Nucl Med Commun 2004; 25: 759-769.
    • (2004) Nucl Med Commun , vol.25 , pp. 759-769
    • Fleming, J.S.1    Zivanovic, M.A.2    Blake, G.M.3
  • 163
    • 0026598725 scopus 로고
    • Estimation of chromium- 51 ethylene diamine tetra-Acetic acid plasma clearance: A comparative assessment of simplified techniques
    • Picciotto G, Cacace G, Cesana P et al. Estimation of chromium- 51 ethylene diamine tetra-Acetic acid plasma clearance: A comparative assessment of simplified techniques. Eur J Nucl Med 1992; 19: 30-35.
    • (1992) Eur J Nucl Med , vol.19 , pp. 30-35
    • Picciotto, G.1    Cacace, G.2    Cesana, P.3
  • 164
    • 0028143063 scopus 로고
    • A simplified determination of glomerular filtration rate with 99Tcm-DTPA
    • Galli G, Rufini V, Meduri G. A simplified determination of glomerular filtration rate with 99Tcm-DTPA. Nucl Med Commun 1994; 15: 831-835.
    • (1994) Nucl Med Commun , vol.15 , pp. 831-835
    • Galli, G.1    Rufini, V.2    Meduri, G.3
  • 165
    • 0024839022 scopus 로고
    • Screening of kidney function by plasma creatinine and single-sample 51Cr-EDTA clearance determination-A comparison
    • Groth S, Aasted M, Vestergaard B. Screening of kidney function by plasma creatinine and single-sample 51Cr-EDTA clearance determination-A comparison. Scand J Clin Lab Invest 1989; 49: 707-710.
    • (1989) Scand J Clin Lab Invest , vol.49 , pp. 707-710
    • Groth, S.1    Aasted, M.2    Vestergaard, B.3
  • 166
    • 0031738697 scopus 로고    scopus 로고
    • Assessment of glomerular filtration rate in diabetic nephropathy using the plasma clearance of 51Cr-EDTA
    • Hansen HP, Rossing P, Mathiesen ER et al. Assessment of glomerular filtration rate in diabetic nephropathy using the plasma clearance of 51Cr-EDTA. Scand J Clin Lab Invest 1998; 58: 405-413.
    • (1998) Scand J Clin Lab Invest , vol.58 , pp. 405-413
    • Hansen, H.P.1    Rossing, P.2    Mathiesen, E.R.3
  • 167
    • 24644462371 scopus 로고    scopus 로고
    • Prediction of two-sample (99m) Tc-diethylene triamine pentaacetic acid plasma clearance from single-sample method
    • Zuo L, Ying C, Wang M et al. Prediction of two-sample (99m) Tc-diethylene triamine pentaacetic acid plasma clearance from single-sample method. Ann Nucl Med 2005; 19: 399-405.
    • (2005) Ann Nucl Med , vol.19 , pp. 399-405
    • Zuo, L.1    Ying, C.2    Wang, M.3
  • 168
    • 33845666782 scopus 로고    scopus 로고
    • Checking the consistency of the two blood samples slope-intercept method for estimating GFR using the single blood sample formula in children
    • De Sadeleer, C, Piepsz A, Ham HR. Checking the consistency of the two blood samples slope-intercept method for estimating GFR using the single blood sample formula in children. Nucl Med Commun 2007; 28: 49-54.
    • (2007) Nucl Med Commun , vol.28 , pp. 49-54
    • Piepsz, A.1    Ham, H.R.2    De Sadeleer, C.3
  • 169
    • 0023090536 scopus 로고
    • Measurement of glomerular filtration rate with technetium-99m DTPA: Comparison of plasma clearance techniques
    • Waller DG, Keast CM, Fleming JS et al. Measurement of glomerular filtration rate with technetium-99m DTPA: comparison of plasma clearance techniques. J Nucl Med 1987; 28: 372-377.
    • (1987) J Nucl Med , vol.28 , pp. 372-377
    • Waller, D.G.1    Keast, C.M.2    Fleming, J.S.3
  • 170
    • 84892411090 scopus 로고    scopus 로고
    • Detection of decreased glomerular filtration rate in intensive care units: Serum cystatin C versus serum creatinine
    • Delanaye P, Cavalier E, Morel J et al. Detection of decreased glomerular filtration rate in intensive care units: serum cystatin C versus serum creatinine. BMC Nephrol 2014; 15: 9.
    • (2014) BMC Nephrol , vol.15 , pp. 9
    • Delanaye, P.1    Cavalier, E.2    Morel, J.3
  • 171
    • 84868310569 scopus 로고    scopus 로고
    • Two novel equations to estimate kidney function in persons aged 70 years or older
    • Schaeffner ES, Ebert N, Delanaye P et al. Two novel equations to estimate kidney function in persons aged 70 years or older. Ann Intern Med 2012; 157: 471-481.
    • (2012) Ann Intern Med , vol.157 , pp. 471-481
    • Schaeffner, E.S.1    Ebert, N.2    Delanaye, P.3
  • 172
    • 84866656037 scopus 로고    scopus 로고
    • Glomerular hyperfiltration and renal disease progression in type 2 diabetes
    • Ruggenenti P, Porrini EL, Gaspari F et al. Glomerular hyperfiltration and renal disease progression in type 2 diabetes. Diabetes Care 2012; 35: 2061-2068.
    • (2012) Diabetes Care , vol.35 , pp. 2061-2068
    • Ruggenenti, P.1    Porrini, E.L.2    Gaspari, F.3
  • 173
    • 84948078467 scopus 로고    scopus 로고
    • Performance of GFR estimating equations stratified by measured or estimated GFR: Implications for interpretation
    • Björk J, Grubb A, Sterner G et al. Performance of GFR estimating equations stratified by measured or estimated GFR: implications for interpretation. Am J Kidney Dis 2015; 66: 1107-1108.
    • (2015) Am J Kidney Dis , vol.66 , pp. 1107-1108
    • Björk, J.1    Grubb, A.2    Sterner, G.3
  • 174
    • 80053504925 scopus 로고    scopus 로고
    • Measured GFR does not outperform estimated GFR in predicting CKD-related complications
    • Hsu CY, Propert K, Xie D et al. Measured GFR does not outperform estimated GFR in predicting CKD-related complications. J Am Soc Nephrol 2011; 22: 1931-1937.
    • (2011) J Am Soc Nephrol , vol.22 , pp. 1931-1937
    • Hsu, C.Y.1    Propert, K.2    Xie, D.3
  • 175
    • 77953683329 scopus 로고    scopus 로고
    • Imprecision of urinary iothalamate clearance as a gold-standard measure of GFR decreases the diagnostic accuracy of kidney function estimating equations
    • Kwong Y-T, Stevens LA, Selvin E et al. Imprecision of urinary iothalamate clearance as a gold-standard measure of GFR decreases the diagnostic accuracy of kidney function estimating equations. Am J Kidney Dis 2010; 56: 39-49.
    • (2010) Am J Kidney Dis , vol.56 , pp. 39-49
    • Kwong, Y.-T.1    Stevens, L.A.2    Selvin, E.3
  • 176
    • 80053637154 scopus 로고    scopus 로고
    • A multicentric evaluation of IDMS-Traceable creatinine enzymatic assays
    • Piéroni L, Delanaye P, Boutten A et al. A multicentric evaluation of IDMS-Traceable creatinine enzymatic assays. Clin Chim Acta 2011; 412: 2070-2075.
    • (2011) Clin Chim Acta , vol.412 , pp. 2070-2075
    • Piéroni, L.1    Delanaye, P.2    Boutten, A.3
  • 177
    • 0018089764 scopus 로고
    • Routine methods and their reliability for assessment of glomerular filtration rate in adults, with special reference to total [51Cr]EDTA plasma clearance
    • Brochner-Mortensen J. Routine methods and their reliability for assessment of glomerular filtration rate in adults, with special reference to total [51Cr]EDTA plasma clearance. Dan Med Bull 1978; 25: 181-202.
    • (1978) Dan Med Bull , vol.25 , pp. 181-202
    • Brochner-Mortensen, J.1
  • 178
    • 0021288699 scopus 로고
    • 51Cr-EDTA clearance determined by one plasma sample in children
    • Groth S, Aasted M. 51Cr-EDTA clearance determined by one plasma sample in children. Clin Physiol 1984; 4: 75-83.
    • (1984) Clin Physiol , vol.4 , pp. 75-83
    • Groth, S.1    Aasted, M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.