메뉴 건너뛰기




Volumn 71, Issue 8, 2011, Pages 663-669

Reliability of 51Cr-EDTA plasma and urinary clearance as a measure of residual renal function in dialysis patients

Author keywords

Adult; chromium radioisotopes; chronic kidney failure; female; glomerular filtration rate; humans; male; renal dialysis; reproducibility of results

Indexed keywords

EDETATE CHROMIUM; CHROMIUM; CREATININE; DIALYSIS FLUID; EDETIC ACID;

EID: 81255189117     PISSN: 00365513     EISSN: 15027686     Source Type: Journal    
DOI: 10.3109/00365513.2011.619565     Document Type: Article
Times cited : (5)

References (20)
  • 2
    • 33646711451 scopus 로고    scopus 로고
    • The importance of residual renal function in dialysis patients
    • Wang AY, Lai KN. The importance of residual renal function in dialysis patients. Kidney Int 2006;69:1726-32.
    • (2006) Kidney Int. , vol.69 , pp. 1726-1732
    • Wang, A.Y.1    Lai, K.N.2
  • 3
    • 67349251531 scopus 로고    scopus 로고
    • The importance of residual kidney function for patients on dialysis: A critical review
    • Perl J, Bargman JM. The importance of residual kidney function for patients on dialysis: A critical review. Am. J. Kidney Dis. 2009;53:1068-81.
    • (2009) Am. J. Kidney Dis. , vol.53 , pp. 1068-1081
    • Perl, J.1    Bargman, J.M.2
  • 4
    • 0021349844 scopus 로고
    • Simultaneous measurement of renal clearance and plasma clearance of 99mTc-labelled diethylenetriaminepenta-acetate, 51Cr-labelled ethylenediaminetetra-acetate and inulin in man
    • Rehling M, Moller ML, Thamdrup B, Lund JO, Trap-Jensen J. Simultaneous measurement of renal clearance and plasma clearance of 99mTc-labelled diethylenetriaminepenta-acetate, 51Cr-labelled ethylenediaminetetra-acetate and inulin in man. Clin Sci (Lond) 1984;66:613-9.
    • (1984) Clin. Sci. Lond , vol.66 , pp. 613-619
    • Rehling, M.1    Moller, M.L.2    Thamdrup, B.3    Lund, J.O.4    Trap-Jensen, J.5
  • 5
    • 0015429594 scopus 로고
    • A simple method for the determination of glomerular fi ltration rate
    • Brochner-Mortensen J. A simple method for the determination of glomerular fi ltration rate. Scand. J. Clin. Lab. Invest. 1972;30:271-4.
    • (1972) Scand. J. Clin. Lab. Invest. , vol.30 , pp. 271-274
    • Brochner-Mortensen, J.1
  • 6
    • 0024471558 scopus 로고
    • 51Cr-EDTA plasma clearance in severe renal failure determined by one plasma sample
    • Kamper AL, Nielsen SL. 51Cr-EDTA plasma clearance in severe renal failure determined by one plasma sample. Scand. J. Clin. Lab. Invest. 1989;49:555-9.
    • (1989) Scand. J. Clin. Lab. Invest. , vol.49 , pp. 555-559
    • Kamper, A.L.1    Nielsen, S.L.2
  • 7
    • 0017053738 scopus 로고
    • Optimum time of blood sampling for determination of glomerular fi ltration rate by single-injection 51Cr EDTA plasma clearance
    • Brochner-Mortensen J, Rodbro P. Optimum time of blood sampling for determination of glomerular fi ltration rate by single-injection [51Cr]EDTA plasma clearance. Scand. J. Clin. Lab. Invest. 1976;36:795-800.
    • (1976) Scand. J. Clin. Lab. Invest. , vol.36 , pp. 795-800
    • Brochner-Mortensen, J.1    Rodbro, P.2
  • 8
    • 33744839368 scopus 로고
    • Clinical calorimetry: Tenth paper: A formula to estimate the approximate surface area if height and weight be known
    • Du Bois D, Du Bois EF. Clinical calorimetry: Tenth paper: A formula to estimate the approximate surface area if height and weight be known. Arch Intern Med 1916;17:863-71.
    • (1916) Arch. Intern. Med. , vol.17 , pp. 863-871
    • Du Bois, D.1    Du Bois, E.F.2
  • 9
    • 0030017818 scopus 로고    scopus 로고
    • Measurement error proportional to the mean
    • Bland JM, Altman DG. Measurement error proportional to the mean. BMJ 1996;313:106.
    • (1996) BMJ , vol.313 , pp. 106
    • Bland, J.M.1    Altman, D.G.2
  • 10
    • 50249138758 scopus 로고    scopus 로고
    • A practical approach to Bland-Altman plots and variation coeffi cients for log transformed variables
    • Euser AM, Dekker FW, le Cessie S. A practical approach to Bland-Altman plots and variation coeffi cients for log transformed variables. J Clin Epidemiol 2008;61:978-82.
    • (2008) J. Clin. Epidemiol. , vol.61 , pp. 978-982
    • Euser, A.M.1    Dekker, F.W.2    Le Cessie, S.3
  • 12
    • 0038777283 scopus 로고    scopus 로고
    • The relative importance of residual renal function compared with peritoneal clearance for patient survival and quality of life: An analysis of the Netherlands cooperative study on the adequacy of dialysis necosad -2
    • Termorshuizen F, Korevaar JC, Dekker FW, van Manen JG, Boeschoten EW, Krediet RT. The relative importance of residual renal function compared with peritoneal clearance for patient survival and quality of life: An analysis of the Netherlands Cooperative Study on the Adequacy of Dialysis (NECOSAD )-2. Am. J. Kidney Dis 2003;41:1293-302.
    • (2003) Am. J. Kidney Dis , vol.41 , pp. 1293-1302
    • Termorshuizen, F.1    Korevaar, J.C.2    Dekker, F.W.3    Van Manen, J.G.4    Boeschoten, E.W.5    Krediet, R.T.6
  • 13
    • 0019411235 scopus 로고
    • Reliability of routine clearance methods for assessment of glomerular fi ltration rate in advanced renal insuffi ciency
    • Brochner-Mortensen J, Freund LG. Reliability of routine clearance methods for assessment of glomerular fi ltration rate in advanced renal insuffi ciency. Scand. J. Clin. Lab. Invest. 1981;41:91-7.
    • (1981) Scand. J. Clin. Lab. Invest. , vol.41 , pp. 91-97
    • Brochner-Mortensen, J.1    Freund, L.G.2
  • 14
    • 0019195060 scopus 로고
    • Over-estimation of glomerular fi ltration rate by single injection 51Cr EDTA plasma clearance determination in patients with ascites
    • Henriksen JH, Brochner-Mortensen J, Malchow-Moller A, Schlichting P. Over-estimation of glomerular fi ltration rate by single injection [51Cr]EDTA plasma clearance determination in patients with ascites. Scand. J. Clin. Lab. Invest. 1980;40:279-84.
    • (1980) Scand. J. Clin. Lab. Invest. , vol.40 , pp. 279-284
    • Henriksen, J.H.1    Brochner-Mortensen, J.2    Malchow-Moller, A.3    Schlichting, P.4
  • 15
    • 0017187888 scopus 로고
    • Comparison between total and renal plasma clearance of 51Cr EDTA
    • Mortensen JB, Rodbro P. Comparison between total and renal plasma clearance of [51Cr] EDTA. Scand. J. Clin. Lab. Invest. 1976;36:247-9.
    • (1976) Scand. J. Clin. Lab. Invest. , vol.36 , pp. 247-249
    • Mortensen, J.B.1    Rodbro, P.2
  • 16
    • 0029586157 scopus 로고
    • Renal and extrarenal clearance of 99mTc- MAG3: A comparison with 125I-OIH and 51Cr-EDTA in patients representing all levels of glomerular fi ltration rate
    • Rehling M, Nielsen BV, Pedersen EB, Nielsen LE, Hansen HE, Bacher T. Renal and extrarenal clearance of 99mTc- MAG3: A comparison with 125I-OIH and 51Cr-EDTA in patients representing all levels of glomerular fi ltration rate. Eur. J. Nucl Med 1995;22:1379-84.
    • (1995) Eur. J. Nucl. Med. , vol.22 , pp. 1379-1384
    • Rehling, M.1    Nielsen, B.V.2    Pedersen, E.B.3    Nielsen, L.E.4    Hansen, H.E.5    Bacher, T.6
  • 17
    • 0025311902 scopus 로고
    • Measurement of renal function with iohexol. A comparison of iohexol 99mTc-DTPA and 51Cr-EDTA clearance
    • Effersoe H, Rosenkilde P, Groth S, Jensen LI, Golman K. Measurement of renal function with iohexol. A comparison of iohexol, 99mTc-DTPA, and 51Cr-EDTA clearance. Invest Radiol 1990;25:778-82.
    • (1990) Invest Radiol. , vol.25 , pp. 778-782
    • Effersoe, H.1    Rosenkilde, P.2    Groth, S.3    Jensen, L.I.4    Golman, K.5
  • 18
    • 0030052705 scopus 로고    scopus 로고
    • Determination of residual renal function with iohexol clearance in hemodialysis patients
    • Swan SK, Halstenson CE, Kasiske BL, Collins AJ. Determination of residual renal function with iohexol clearance in hemodialysis patients. Kidney Int 1996;49:232-5.
    • (1996) Kidney Int. , vol.49 , pp. 232-235
    • Swan, S.K.1    Halstenson, C.E.2    Kasiske, B.L.3    Collins, A.J.4
  • 19
    • 0033843727 scopus 로고    scopus 로고
    • Assessing residual renal function and effi ciency of hemodialysis - An application for urographic contrast media
    • Sterner G, Frennby B, Mansson S, Ohlsson A, Prutz KG, Almen T. Assessing residual renal function and effi ciency of hemodialysis - an application for urographic contrast media. Nephron 2000;85:324-33.
    • (2000) Nephron , vol.85 , pp. 324-333
    • Sterner, G.1    Frennby, B.2    Mansson, S.3    Ohlsson, A.4    Prutz, K.G.5    Almen, T.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.