메뉴 건너뛰기




Volumn 396, Issue 1-2, 2008, Pages 80-85

Performance of iohexol determination in serum and urine by HPLC: Validation, risk and uncertainty assessment

Author keywords

Analytical validation; Glomerular filtration rate; Iohexol; Measurement uncertainty; Reference method

Indexed keywords

IOHEXOL;

EID: 50049114927     PISSN: 00098981     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.cca.2008.07.011     Document Type: Article
Times cited : (62)

References (32)
  • 3
    • 0026442320 scopus 로고
    • Serum creatinine as an index of renal function: new insights into old concepts
    • Perrone R.D., Madias N.E., and Levey A.S. Serum creatinine as an index of renal function: new insights into old concepts. Clin Chem 38 (1992) 1933-1953
    • (1992) Clin Chem , vol.38 , pp. 1933-1953
    • Perrone, R.D.1    Madias, N.E.2    Levey, A.S.3
  • 4
  • 5
    • 44449090694 scopus 로고    scopus 로고
    • Estimated glomerular filtration rate as an end point in kidney transplant trial: where do we stand?
    • Mariat C., Maillard N., Phayphet M., et al. Estimated glomerular filtration rate as an end point in kidney transplant trial: where do we stand?. Nephrol Dial Transplant 23 (2008) 33-38
    • (2008) Nephrol Dial Transplant , vol.23 , pp. 33-38
    • Mariat, C.1    Maillard, N.2    Phayphet, M.3
  • 6
    • 0014527230 scopus 로고
    • Renal inulin clearance versus total plasma clearance of 51Cr-EDTA
    • Brochner-Mortensen J., Giese J., and Rossing N. Renal inulin clearance versus total plasma clearance of 51Cr-EDTA. Scand J Clin Lab Invest 23 (1969) 301-305
    • (1969) Scand J Clin Lab Invest , vol.23 , pp. 301-305
    • Brochner-Mortensen, J.1    Giese, J.2    Rossing, N.3
  • 7
    • 0019153477 scopus 로고
    • Determination of glomerular filtration rate (GFR) by analysis of capillary blood after single shot injection of 99mTc-DTPA. A comparison with simultaneous 125I-iothalamate GFR estimation showing equal GFR but difference in distribution volume
    • Rootwelt K., Falch D., and Sjokvist R. Determination of glomerular filtration rate (GFR) by analysis of capillary blood after single shot injection of 99mTc-DTPA. A comparison with simultaneous 125I-iothalamate GFR estimation showing equal GFR but difference in distribution volume. Eur J Nucl Med 5 (1980) 97-102
    • (1980) Eur J Nucl Med , vol.5 , pp. 97-102
    • Rootwelt, K.1    Falch, D.2    Sjokvist, R.3
  • 8
    • 0026045977 scopus 로고
    • Iohexol clearance for the determination of glomerular filtration rate in clinical practice: evidence for a new gold standard
    • Brown S.C., and O'Reilly P.H. Iohexol clearance for the determination of glomerular filtration rate in clinical practice: evidence for a new gold standard. J Urol 146 (1991) 675-679
    • (1991) J Urol , vol.146 , pp. 675-679
    • Brown, S.C.1    O'Reilly, P.H.2
  • 9
    • 0036484461 scopus 로고    scopus 로고
    • Contrast media as markers of GFR
    • Frennby B., and Sterner G. Contrast media as markers of GFR. Eur Radiol 12 (2002) 475-484
    • (2002) Eur Radiol , vol.12 , pp. 475-484
    • Frennby, B.1    Sterner, G.2
  • 11
    • 0024238897 scopus 로고
    • A simple chemical method for the quantification of the contrast agent iohexol, applicable to glomerular filtration rate measurements
    • Back S.E., Masson P., and Nilsson-Ehle P. A simple chemical method for the quantification of the contrast agent iohexol, applicable to glomerular filtration rate measurements. Scand J Clin Lab Invest 48 (1988) 825-829
    • (1988) Scand J Clin Lab Invest , vol.48 , pp. 825-829
    • Back, S.E.1    Masson, P.2    Nilsson-Ehle, P.3
  • 12
    • 0021672741 scopus 로고
    • Plasma clearance of a new contrast agent, iohexol: a method for the assessment of glomerular filtration rate
    • Krutzen E., Back S.E., Nilsson-Ehle I., and Nilsson-Ehle P. Plasma clearance of a new contrast agent, iohexol: a method for the assessment of glomerular filtration rate. J Lab Clin Med 104 (1984) 955-961
    • (1984) J Lab Clin Med , vol.104 , pp. 955-961
    • Krutzen, E.1    Back, S.E.2    Nilsson-Ehle, I.3    Nilsson-Ehle, P.4
  • 13
    • 0026448041 scopus 로고
    • Iohexol in serum determined by capillary electrophoresis
    • Shihabi Z.K., and Constantinescu M.S. Iohexol in serum determined by capillary electrophoresis. Clin Chem 38 (1992) 2117-2120
    • (1992) Clin Chem , vol.38 , pp. 2117-2120
    • Shihabi, Z.K.1    Constantinescu, M.S.2
  • 14
    • 50049094309 scopus 로고    scopus 로고
    • International conference on harmonization (ICH) of technical requirements for registration of pharmaceuticals for human use, topic Q2 R1. Validation of analytical procedures: text and methodology. 2005. Geneva. 2005.
    • International conference on harmonization (ICH) of technical requirements for registration of pharmaceuticals for human use, topic Q2 R1. Validation of analytical procedures: text and methodology. 2005. Geneva. 2005.
  • 15
    • 50049094046 scopus 로고    scopus 로고
    • ISO 5725-1, Application of the statistics-accuracy (trueness and precision) of the results and methods of meassurement-Part 1: General principles and definitions. International Organization for Standardization (ISO). 2005. Geneva.
    • ISO 5725-1, Application of the statistics-accuracy (trueness and precision) of the results and methods of meassurement-Part 1: General principles and definitions. International Organization for Standardization (ISO). 2005. Geneva.
  • 16
    • 7444240202 scopus 로고    scopus 로고
    • Harmonization of strategies for the validation of quantitative analytical procedures. A SFSTP proposal-Part I
    • Hubert P., Nguyen-Huu J.J., Boulanger B., et al. Harmonization of strategies for the validation of quantitative analytical procedures. A SFSTP proposal-Part I. J Pharm Biomed Anal 36 (2004) 579-586
    • (2004) J Pharm Biomed Anal , vol.36 , pp. 579-586
    • Hubert, P.1    Nguyen-Huu, J.J.2    Boulanger, B.3
  • 17
    • 50049124230 scopus 로고    scopus 로고
    • Guidance for idustry: Bioanalytical Mathod Validation, US Department of Health and Human Services, Food and Drug Administration, Center for Drug Evaluation and Research (CDER), Center for Biologics Evaluation and Research (CBER). 2001. Rockville.
    • Guidance for idustry: Bioanalytical Mathod Validation, US Department of Health and Human Services, Food and Drug Administration, Center for Drug Evaluation and Research (CDER), Center for Biologics Evaluation and Research (CBER). 2001. Rockville.
  • 20
    • 9944255782 scopus 로고    scopus 로고
    • New advances in method validation and measurement uncertainty aimed at improving the quality of chemical data
    • Feinberg M., Boulanger B., Dewe W., and Hubert P. New advances in method validation and measurement uncertainty aimed at improving the quality of chemical data. Anal Bioanal Chem 380 (2004) 502-514
    • (2004) Anal Bioanal Chem , vol.380 , pp. 502-514
    • Feinberg, M.1    Boulanger, B.2    Dewe, W.3    Hubert, P.4
  • 21
    • 50049099930 scopus 로고    scopus 로고
    • EURACHEM/CITAC Guide CG 4; Quantifying uncertainty in analytical measurement, Second Edition. 2000.
    • EURACHEM/CITAC Guide CG 4; Quantifying uncertainty in analytical measurement, Second Edition. 2000.
  • 22
    • 0004389169 scopus 로고
    • What about the other intervals?
    • Vardeman S.B. What about the other intervals?. The American Statistician 46 (1992) 193-196
    • (1992) The American Statistician , vol.46 , pp. 193-196
    • Vardeman, S.B.1
  • 23
    • 50049095395 scopus 로고    scopus 로고
    • Hahn GJ and Meeker WQ. Statistical intervals: a guide for practitioners. Wiley Edition, 392, 1991 September.
    • Hahn GJ and Meeker WQ. Statistical intervals: a guide for practitioners. Wiley Edition, 392, 1991 September.
  • 24
    • 34447103711 scopus 로고    scopus 로고
    • Analysis of recent pharmaceutical regulatory documents on analytical method validation
    • Rozet E., Ceccato A., Hubert C., et al. Analysis of recent pharmaceutical regulatory documents on analytical method validation. J Chromatogr A 1158 (2007) 111-125
    • (2007) J Chromatogr A , vol.1158 , pp. 111-125
    • Rozet, E.1    Ceccato, A.2    Hubert, C.3
  • 25
    • 34447107152 scopus 로고    scopus 로고
    • Using tolerance intervals in pre-study validation of analytical methods to predict in-study results. The fit-for-future-purpose concept
    • Rozet E., Hubert C., Ceccato A., et al. Using tolerance intervals in pre-study validation of analytical methods to predict in-study results. The fit-for-future-purpose concept. J Chromatogr A 1158 (2007) 126-137
    • (2007) J Chromatogr A , vol.1158 , pp. 126-137
    • Rozet, E.1    Hubert, C.2    Ceccato, A.3
  • 26
    • 34548532560 scopus 로고    scopus 로고
    • Harmonization of strategies for the validation of quantitative analytical procedures. A SFSTP proposal-part III
    • Hubert P., Nguyen-Huu J.J., Boulanger B., et al. Harmonization of strategies for the validation of quantitative analytical procedures. A SFSTP proposal-part III. J Pharm Biomed Anal 45 (2007) 82-96
    • (2007) J Pharm Biomed Anal , vol.45 , pp. 82-96
    • Hubert, P.1    Nguyen-Huu, J.J.2    Boulanger, B.3
  • 27
    • 33751206818 scopus 로고    scopus 로고
    • Performances of a multidimensional on-line SPE-LC-ECD method for the determination of three major catecholamines in native human urine: validation, risk and uncertainty assessments
    • Rozet E., Morello R., Lecomte F., et al. Performances of a multidimensional on-line SPE-LC-ECD method for the determination of three major catecholamines in native human urine: validation, risk and uncertainty assessments. J Chromatogr B Analyt Technol Biomed Life Sci 844 (2006) 251-260
    • (2006) J Chromatogr B Analyt Technol Biomed Life Sci , vol.844 , pp. 251-260
    • Rozet, E.1    Morello, R.2    Lecomte, F.3
  • 28
    • 0036000814 scopus 로고    scopus 로고
    • Evaluation of uncertainty of measurement in routine clinical chemistry-applications to determination of the substance concentration of calcium and glucose in serum
    • Linko S., Ornemark U., Kessel R., and Taylor P.D. Evaluation of uncertainty of measurement in routine clinical chemistry-applications to determination of the substance concentration of calcium and glucose in serum. Clin Chem Lab Med 40 (2002) 391-398
    • (2002) Clin Chem Lab Med , vol.40 , pp. 391-398
    • Linko, S.1    Ornemark, U.2    Kessel, R.3    Taylor, P.D.4
  • 30
    • 33847671375 scopus 로고    scopus 로고
    • Reproducibility of renal function measurements in adult men with diabetic nephropathy: research and clinical implications
    • Agarwal R. Reproducibility of renal function measurements in adult men with diabetic nephropathy: research and clinical implications. Am J Nephrol 27 (2007) 92-100
    • (2007) Am J Nephrol , vol.27 , pp. 92-100
    • Agarwal, R.1
  • 31
    • 0030122480 scopus 로고    scopus 로고
    • Precision of glomerular filtration rate determinations for long-term slope calculations is improved by simultaneous infusion of 125I-iothalamate and 131I-hippuran
    • Apperloo A.J., de Zeeuw D., Donker A.J., and de Jong P.E. Precision of glomerular filtration rate determinations for long-term slope calculations is improved by simultaneous infusion of 125I-iothalamate and 131I-hippuran. J Am Soc Nephrol 7 (1996) 567-572
    • (1996) J Am Soc Nephrol , vol.7 , pp. 567-572
    • Apperloo, A.J.1    de Zeeuw, D.2    Donker, A.J.3    de Jong, P.E.4
  • 32
    • 26844572621 scopus 로고    scopus 로고
    • Simple HPLC-UV method for determination of iohexol, iothalamate, p-aminohippuric acid and n-acetyl-p-aminohippuric acid in human plasma and urine with ERPF, GFR and ERPF/GFR ratio determination using colorimetric analysis
    • Farthing D., Sica D.A., Fakhry I., et al. Simple HPLC-UV method for determination of iohexol, iothalamate, p-aminohippuric acid and n-acetyl-p-aminohippuric acid in human plasma and urine with ERPF, GFR and ERPF/GFR ratio determination using colorimetric analysis. J Chromatogr B Analyt Technol Biomed Life Sci 826 (2005) 267-272
    • (2005) J Chromatogr B Analyt Technol Biomed Life Sci , vol.826 , pp. 267-272
    • Farthing, D.1    Sica, D.A.2    Fakhry, I.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.