메뉴 건너뛰기




Volumn 13, Issue 5, 1998, Pages 1176-1182

GFR measurement with iohexol and 51Cr-EDTA. A comparison of the two favoured GFR markers in Europe

Author keywords

Cr EDTA clearance; Glomerular filtration rate; Iohexol

Indexed keywords

EDETATE CHROMIUM CR 51; IODINE; IOHEXOL;

EID: 0031959667     PISSN: 09310509     EISSN: None     Source Type: Journal    
DOI: 10.1093/ndt/13.5.1176     Document Type: Article
Times cited : (153)

References (25)
  • 1
    • 0000887577 scopus 로고
    • Studies on kidney function. I. The rate of filtration and reabsorption in the human kidney
    • Rehberg PB. Studies on kidney function. I. The rate of filtration and reabsorption in the human kidney. Biochem J 1926; 20: 447-453
    • (1926) Biochem J , vol.20 , pp. 447-453
    • Rehberg, P.B.1
  • 2
    • 0006081723 scopus 로고
    • The excretion of inulin xylose, and urea by normal phlorizinized man
    • Shannon J, Smith HW. The excretion of inulin xylose, and urea by normal phlorizinized man. J Clin Invest 1935; 14: 393
    • (1935) J Clin Invest , vol.14 , pp. 393
    • Shannon, J.1    Smith, H.W.2
  • 4
    • 0029998582 scopus 로고    scopus 로고
    • Report of the Radionuclides in Nephrourology Committee on renal clearance
    • Blaufox MD, Aurell M, Bubeck B et al. Report of the Radionuclides in Nephrourology Committee on renal clearance. J Nucl Med 1996; 37: 1883-1890
    • (1996) J Nucl Med , vol.37 , pp. 1883-1890
    • Blaufox, M.D.1    Aurell, M.2    Bubeck, B.3
  • 5
    • 0021672741 scopus 로고
    • Plasma clearance of a new contrast agent, iohexol: A method for the assessment of glomerular filtration rate
    • Krutzén E, Bäck SE, Nilsson-Ehle I, Nilsson-Ehle P. Plasma clearance of a new contrast agent, iohexol: a method for the assessment of glomerular filtration rate. J Lab Clin Med 1984; 104: 955-961
    • (1984) J Lab Clin Med , vol.104 , pp. 955-961
    • Krutzén, E.1    Bäck, S.E.2    Nilsson-Ehle, I.3    Nilsson-Ehle, P.4
  • 6
    • 0020520393 scopus 로고
    • Noninvasive estimation of kidney function by X-ray fluorescence analysis. Elimination rate and clearance of contrast media injected for urography in man
    • Grönberg T, Sjöberg S, Almén T, Golman K, Mattsson S. Noninvasive estimation of kidney function by X-ray fluorescence analysis. Elimination rate and clearance of contrast media injected for urography in man. Invest Radiol 1983; 18: 445-452
    • (1983) Invest Radiol , vol.18 , pp. 445-452
    • Grönberg, T.1    Sjöberg, S.2    Almén, T.3    Golman, K.4    Mattsson, S.5
  • 7
    • 0026045977 scopus 로고
    • Iohexol clearance for the determination of glomerular filtration rate in clinical practice: Evidence for a new gold standard
    • Brown SCW, O'Reilly PH. Iohexol clearance for the determination of glomerular filtration rate in clinical practice: evidence for a new gold standard. J Urol 1991; 146: 675-679
    • (1991) J Urol , vol.146 , pp. 675-679
    • Brown, S.C.W.1    O'Reilly, P.H.2
  • 10
    • 0027980257 scopus 로고
    • Accurate and feasible measurements of GFR - Is the iohexol clearance an answer?
    • Aurell M. Accurate and feasible measurements of GFR - is the iohexol clearance an answer? Nephrol Dialysis Transplant 1994; 9: 1222-1224
    • (1994) Nephrol Dialysis Transplant , vol.9 , pp. 1222-1224
    • Aurell, M.1
  • 12
    • 0015429594 scopus 로고
    • A simple method for the determination of glomerular filtration rate
    • Brøchner-Mortensen J. A simple method for the determination of glomerular filtration rate. Scand J Clin Lab Invest 1972; 30: 271-274
    • (1972) Scand J Clin Lab Invest , vol.30 , pp. 271-274
    • Brøchner-Mortensen, J.1
  • 13
    • 0020955393 scopus 로고
    • A method for calculation of renal clearance based on a single plasma sample
    • Jacobsson L. A method for calculation of renal clearance based on a single plasma sample. Clin Physiol 1983; 3: 297-305
    • (1983) Clin Physiol , vol.3 , pp. 297-305
    • Jacobsson, L.1
  • 14
    • 0025826993 scopus 로고
    • Glomerular filtration rate: A comparison between Cr-EDTA clearance and a single sample technique with a non-ionic contrast agent
    • Eriksson C-G, Kaliner A. Glomerular filtration rate: a comparison between Cr-EDTA clearance and a single sample technique with a non-ionic contrast agent. Clin Biochem 1991; 24: 261-264
    • (1991) Clin Biochem , vol.24 , pp. 261-264
    • Eriksson, C.-G.1    Kaliner, A.2
  • 15
    • 0027480840 scopus 로고
    • Assay of radiographic contrast agents in mice plasma and tested by highperformance liquid chromatography
    • Ravi S, Yaghmani V, Patel Y, Baker SR, Rao DV. Assay of radiographic contrast agents in mice plasma and tested by highperformance liquid chromatography. Anal Chem 1993; 65: 606-612
    • (1993) Anal Chem , vol.65 , pp. 606-612
    • Ravi, S.1    Yaghmani, V.2    Patel, Y.3    Baker, S.R.4    Rao, D.V.5
  • 16
    • 0024267179 scopus 로고
    • Glomerular filtration rate estimated after multiple injections of contrast medium during angiography
    • Boijsen M, Granerus G, Jacobsson L, Björneld L, Aurell M, Tylén U. Glomerular filtration rate estimated after multiple injections of contrast medium during angiography. Acta Radiol 1988; 29: 669-674
    • (1988) Acta Radiol , vol.29 , pp. 669-674
    • Boijsen, M.1    Granerus, G.2    Jacobsson, L.3    Björneld, L.4    Aurell, M.5    Tylén, U.6
  • 17
    • 0029090867 scopus 로고
    • Plasma clearance of nonradioactive iohexol as a measure of glomerular filtration rate
    • Gaspari F, Perico N, Ruggenenti P et al. Plasma clearance of nonradioactive iohexol as a measure of glomerular filtration rate. J Am Soc Nephrol 1995; 6: 257-263
    • (1995) J Am Soc Nephrol , vol.6 , pp. 257-263
    • Gaspari, F.1    Perico, N.2    Ruggenenti, P.3
  • 18
    • 0030378024 scopus 로고    scopus 로고
    • Glomerular nitration rate determined from a single plasma sample after intravenous iohexol injection: Is it reliable?
    • Gaspari F, Guerini E, Perico N, Mosconi L, Ruggenenti P, Remuzzi G. Glomerular nitration rate determined from a single plasma sample after intravenous iohexol injection: is it reliable? J Am Soc Nephrol 1996; 7: 2689-2693
    • (1996) J Am Soc Nephrol , vol.7 , pp. 2689-2693
    • Gaspari, F.1    Guerini, E.2    Perico, N.3    Mosconi, L.4    Ruggenenti, P.5    Remuzzi, G.6
  • 20
    • 0022529348 scopus 로고
    • Accuracy and reproducibility of a new contrast clearance method for the determination of glomerular filtration rate
    • O'Reilly PH, Brooman PJC, Martin PJ, Pollard AJ, Farah NB, Mason GC. Accuracy and reproducibility of a new contrast clearance method for the determination of glomerular filtration rate. Br Med J 1986; 293: 234-236
    • (1986) Br Med J , vol.293 , pp. 234-236
    • O'Reilly, P.H.1    Brooman, P.J.C.2    Martin, P.J.3    Pollard, A.J.4    Farah, N.B.5    Mason, G.C.6
  • 21
    • 0023931534 scopus 로고
    • Measurement of the plasma clearance of urographic contrast media for the determination of glomerular filtration rate
    • O'Reilly PH, Jones DA, Farah NB. Measurement of the plasma clearance of urographic contrast media for the determination of glomerular filtration rate. J Urol 1988; 139: 9-11
    • (1988) J Urol , vol.139 , pp. 9-11
    • O'Reilly, P.H.1    Jones, D.A.2    Farah, N.B.3
  • 22
    • 0025972559 scopus 로고
    • Estimation of glomerular filtration rate from low-dose injection of iohexol and a single blood sample
    • Thomsen HS, Hvid-Jacobsen K. Estimation of glomerular filtration rate from low-dose injection of iohexol and a single blood sample. Invest Radiol 1991; 26: 332-336
    • (1991) Invest Radiol , vol.26 , pp. 332-336
    • Thomsen, H.S.1    Hvid-Jacobsen, K.2
  • 24
    • 0028542209 scopus 로고
    • New markers for the determination of GFR: Iohexol clearance and cystatin C serum concentration
    • Nilsson-Ehle I, Grubb A. New markers for the determination of GFR: iohexol clearance and cystatin C serum concentration. Kidney Int 1994; [Suppl. 47]: S17-S19
    • (1994) Kidney Int , Issue.47 SUPPL.
    • Nilsson-Ehle, I.1    Grubb, A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.