메뉴 건너뛰기




Volumn 24, Issue 8, 2016, Pages 827-836

Effects of Different Tactile Feedback on Myoelectric Closed-Loop Control for Grasping Based on Electrotactile Stimulation

Author keywords

Closed loop control; electrotactile stimulation; grasping force; myoelectric prosthesis; pressure feedback; slip feedback

Indexed keywords

ARTIFICIAL LIMBS; MYOELECTRICALLY CONTROLLED PROSTHETICS; PROSTHETICS; VIRTUAL REALITY;

EID: 84982133087     PISSN: 15344320     EISSN: None     Source Type: Journal    
DOI: 10.1109/TNSRE.2015.2478153     Document Type: Article
Times cited : (41)

References (35)
  • 2
    • 80054062765 scopus 로고    scopus 로고
    • Object discrimination with an artificial hand using electrical stimulation of peripheral tactile and proprioceptive pathways with intrafascicular electrodes
    • Sep.
    • K. Horch, S. Meek, T. G. Taylor, and D. T. Hutchinson, "Object discrimination with an artificial hand using electrical stimulation of peripheral tactile and proprioceptive pathways with intrafascicular electrodes, " IEEE Trans. Neural Syst. Rehabil. Eng., vol. 19, no. 5, pp. 483-489, Sep. 2011.
    • (2011) IEEE Trans. Neural Syst. Rehabil. Eng. , vol.19 , Issue.5 , pp. 483-489
    • Horch, K.1    Meek, S.2    Taylor, T.G.3    Hutchinson, D.T.4
  • 3
    • 84892572914 scopus 로고    scopus 로고
    • Stiffness feedback for myoelectric forearm prostheses using vibrotactile stimulation
    • Jan.
    • H. J. Witteveen, F. Luft, J. S. Rietman, and P. H. Veltink, "Stiffness feedback for myoelectric forearm prostheses using vibrotactile stimulation, " IEEE Trans. Neural Syst. Rehabil. Eng., vol. 22, no. 1, pp. 53-61, Jan. 2014.
    • (2014) IEEE Trans. Neural Syst. Rehabil. Eng. , vol.22 , Issue.1 , pp. 53-61
    • Witteveen, H.J.1    Luft, F.2    Rietman, J.S.3    Veltink, P.H.4
  • 4
    • 0027025157 scopus 로고
    • Sensory-motor coordination during grasping and manipulative actions
    • R. S. Johansson and K. J. Cole, "Sensory-motor coordination during grasping and manipulative actions, " Current Opinion Neurobiol., vol. 2, no. 6, pp. 815-823, 1992.
    • (1992) Current Opinion Neurobiol. , vol.2 , Issue.6 , pp. 815-823
    • Johansson, R.S.1    Cole, K.J.2
  • 5
    • 0030554768 scopus 로고    scopus 로고
    • Epidemiologic overview of individuals with upper-limb loss and their reported research priorities
    • D. J. Atkins, D. C. Heard, and W. H. Donovan, "Epidemiologic overview of individuals with upper-limb loss and their reported research priorities, " JPO: J. Prosthetics Orthotics, vol. 8, no. 1, pp. 2-11, 1996.
    • (1996) JPO: J. Prosthetics Orthotics , vol.8 , Issue.1 , pp. 2-11
    • Atkins, D.J.1    Heard, D.C.2    Donovan, W.H.3
  • 6
    • 84455188803 scopus 로고    scopus 로고
    • Characterizing the performance of an optical slip sensor for grip control in a prosthesis
    • IEEE
    • H. N. Sani and S. G. Meek, "Characterizing the performance of an optical slip sensor for grip control in a prosthesis, " in Proc. IEEE/RSJ Int. Conf. Intelligent Robots and Systems (IROS), 2011, pp. 1927-1932, IEEE.
    • (2011) Proc. IEEE/RSJ Int. Conf. Intelligent Robots and Systems (IROS) , pp. 1927-1932
    • Sani, H.N.1    Meek, S.G.2
  • 7
    • 84888337951 scopus 로고    scopus 로고
    • Adaptive sliding manifold slope via grasped object stiffness detection with a prosthetic hand
    • R. Andrecioli and E. D. Engeberg, "Adaptive sliding manifold slope via grasped object stiffness detection with a prosthetic hand, " Mechatronics, vol. 23, no. 8, pp. 1171-1179, 2013.
    • (2013) Mechatronics , vol.23 , Issue.8 , pp. 1171-1179
    • Andrecioli, R.1    Engeberg, E.D.2
  • 9
    • 33747894692 scopus 로고    scopus 로고
    • Predictive and reactive control of grasping forces: On the role of the basal ganglia and sensory feedback
    • D. A. Nowak and J. Hermsdörfer, "Predictive and reactive control of grasping forces: On the role of the basal ganglia and sensory feedback, " Experimental Brain Res., vol. 173, no. 4, pp. 650-660, 2006.
    • (2006) Experimental Brain Res. , vol.173 , Issue.4 , pp. 650-660
    • Nowak, D.A.1    Hermsdörfer, J.2
  • 12
    • 84955498547 scopus 로고    scopus 로고
    • Vibrotactile grasping force and hand aperture feedback for myoelectric forearm prosthesis users
    • 0309364614522260
    • H. J. Witteveen, H. S. Rietman, and P. H. Veltink, "Vibrotactile grasping force and hand aperture feedback for myoelectric forearm prosthesis users, " Prosthetics Orthotics Int., p. 0309364614522260, 2014.
    • (2014) Prosthetics Orthotics Int.
    • Witteveen, H.J.1    Rietman, H.S.2    Veltink, P.H.3
  • 13
    • 84908371045 scopus 로고    scopus 로고
    • Closed loop control of grasping with a myoelectric hand prosthesis: Which are the relevant feedback variables for force control?
    • Sep.
    • A. Ninu, S. Dosen, S. Muceli, F. Rattay, H. Dietl, and D. Farina, "Closed loop control of grasping with a myoelectric hand prosthesis: Which are the relevant feedback variables for force control?, " IEEE Trans. Neural Syst. Rehabil. Eng., vol. 22, no. 5, pp. 1041-1052, Sep. 2014.
    • (2014) IEEE Trans. Neural Syst. Rehabil. Eng. , vol.22 , Issue.5 , pp. 1041-1052
    • Ninu, A.1    Dosen, S.2    Muceli, S.3    Rattay, F.4    Dietl, H.5    Farina, D.6
  • 14
    • 84880894117 scopus 로고    scopus 로고
    • Vibrotactile sensory substitution for electromyographic control of object manipulation
    • Aug.
    • E. Rombokas, C. E. Stepp, C. Chang, M. Malhotra, and Y. Matsuoka, "Vibrotactile sensory substitution for electromyographic control of object manipulation, " IEEE Trans. Biomed. Eng., vol. 60, no. 8, pp. 2226-2232, Aug. 2013.
    • (2013) IEEE Trans. Biomed. Eng. , vol.60 , Issue.8 , pp. 2226-2232
    • Rombokas, E.1    Stepp, C.E.2    Chang, C.3    Malhotra, M.4    Matsuoka, Y.5
  • 15
  • 16
    • 84977134311 scopus 로고    scopus 로고
    • Restoring natural sensory feedback in real-time bidirectional hand prostheses
    • S. Raspopovic et al., "Restoring natural sensory feedback in real-time bidirectional hand prostheses, " Sci. Translational Medicine, vol. 6, no. 222, pp. 222ra19-222ra19, 2014.
    • (2014) Sci. Translational Medicine , vol.6 , Issue.222 , pp. 222ra19-222ra19
    • Raspopovic, S.1
  • 17
    • 84926452678 scopus 로고    scopus 로고
    • Humans can integrate feedback of discrete events in their sensorimotor control of a robotic hand
    • C. Cipriani et al., "Humans can integrate feedback of discrete events in their sensorimotor control of a robotic hand, " Experimental Brain Res., vol. 232, no. 11, pp. 3421-3429, 2014.
    • (2014) Experimental Brain Res. , vol.232 , Issue.11 , pp. 3421-3429
    • Cipriani, C.1
  • 18
    • 83455220037 scopus 로고    scopus 로고
    • Object manipulation improvements due to single session training outweigh the differences among stimulation sites during vibrotactile feedback
    • Nov.
    • C. E. Stepp and Y. Matsuoka, "Object manipulation improvements due to single session training outweigh the differences among stimulation sites during vibrotactile feedback, " IEEE Trans. Neural Syst. Rehabil. Eng., vol. 19, no. 6, pp. 677-685, Nov. 2011.
    • (2011) IEEE Trans. Neural Syst. Rehabil. Eng. , vol.19 , Issue.6 , pp. 677-685
    • Stepp, C.E.1    Matsuoka, Y.2
  • 20
    • 80054943371 scopus 로고    scopus 로고
    • The role of feed-forward and feedback processes for closed-loop prosthesis control
    • I. Saunders and S. Vijayakumar, "The role of feed-forward and feedback processes for closed-loop prosthesis control, " J. Neuroeng. Rehabil., vol. 8, no. 60, pp. 1-12, 2011.
    • (2011) J. Neuroeng. Rehabil. , vol.8 , Issue.60 , pp. 1-12
    • Saunders, I.1    Vijayakumar, S.2
  • 21
    • 0027006830 scopus 로고
    • Design and evaluation of a sensory feedback system that provides grasping pressure in a myoelectric hand
    • P. E. Patterson and J. A. Katz, "Design and evaluation of a sensory feedback system that provides grasping pressure in a myoelectric hand, " J. Rehabil. Res. Dev., vol. 29, no. 1, pp. 1-8, 1992.
    • (1992) J. Rehabil. Res. Dev. , vol.29 , Issue.1 , pp. 1-8
    • Patterson, P.E.1    Katz, J.A.2
  • 22
  • 23
    • 40949129655 scopus 로고    scopus 로고
    • On the shared control of an EMG-controlled prosthetic hand: Analysis of user-prosthesis interaction
    • Jan.
    • C. Cipriani, F. Zaccone, S. Micera, and M. C. Carrozza, "On the shared control of an EMG-controlled prosthetic hand: Analysis of user-prosthesis interaction, " IEEE Trans. Robot., vol. 24, no. 1, pp. 170-184, Jan. 2008.
    • (2008) IEEE Trans. Robot. , vol.24 , Issue.1 , pp. 170-184
    • Cipriani, C.1    Zaccone, F.2    Micera, S.3    Carrozza, M.C.4
  • 25
    • 0027188687 scopus 로고
    • Estimating friction using incipient slip sensing during a manipulation task
    • IEEE
    • M. R. Tremblay and M. R. Cutkosky, "Estimating friction using incipient slip sensing during a manipulation task, " in Proc. IEEE Int. Conf. Robotics Automation, 1993, pp. 429-434, IEEE.
    • (1993) Proc. IEEE Int. Conf. Robotics Automation , pp. 429-434
    • Tremblay, M.R.1    Cutkosky, M.R.2
  • 28
    • 79651471227 scopus 로고    scopus 로고
    • Impacts of selected stimulation patterns on the perception threshold in electrocutaneous stimulation
    • B. Geng, K. Yoshida, and W. Jensen, "Impacts of selected stimulation patterns on the perception threshold in electrocutaneous stimulation, " J. Neuroeng. Rehabil., vol. 8, no. 9, 2011.
    • (2011) J. Neuroeng. Rehabil. , vol.8 , Issue.9
    • Geng, B.1    Yoshida, K.2    Jensen, W.3
  • 30
    • 0029239818 scopus 로고
    • Evaluation of handgrip force from EMG measurements
    • J. Duque, D. Masset, and J. Malchaire, "Evaluation of handgrip force from EMG measurements, " Appl. Ergonomics, vol. 26, no. 1, pp. 61-66, 1995.
    • (1995) Appl. Ergonomics , vol.26 , Issue.1 , pp. 61-66
    • Duque, J.1    Masset, D.2    Malchaire, J.3
  • 31
    • 0036592583 scopus 로고    scopus 로고
    • Evaluation of command algorithms for control of upper-extremity neural prostheses
    • Mar.
    • S. D. Humbert, S. A. Snyder, and W. M. Grill, Jr, "Evaluation of command algorithms for control of upper-extremity neural prostheses, " IEEE Trans. Neural Syst. Rehabil. Eng., vol. 10, no. 2, pp. 94-101, Mar. 2002.
    • (2002) IEEE Trans. Neural Syst. Rehabil. Eng. , vol.10 , Issue.2 , pp. 94-101
    • Humbert, S.D.1    Snyder, S.A.2    Grill, W.M.3
  • 33
  • 34
    • 0036430233 scopus 로고    scopus 로고
    • Thin flexible pressure sensors
    • C. Ashruf, "Thin flexible pressure sensors, " Sensor Rev., vol. 22, no. 4, pp. 322-327, 2002.
    • (2002) Sensor Rev. , vol.22 , Issue.4 , pp. 322-327
    • Ashruf, C.1
  • 35
    • 34247174001 scopus 로고    scopus 로고
    • A novel thick-film piezoelectric slip sensor for a prosthetic hand
    • D. P. Cotton, P. H. Chappell, A. Cranny, N. M. White, and S. P. Beeby, "A novel thick-film piezoelectric slip sensor for a prosthetic hand, " IEEE Sensors J., vol. 7, no. 5, pp. 752-761, 2007.
    • (2007) IEEE Sensors J. , vol.7 , Issue.5 , pp. 752-761
    • Cotton, D.P.1    Chappell, P.H.2    Cranny, A.3    White, N.M.4    Beeby, S.P.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.