메뉴 건너뛰기




Volumn 232, Issue 11, 2014, Pages 3421-3429

Humans can integrate feedback of discrete events in their sensorimotor control of a robotic hand

Author keywords

Hand; Human; Sensorimotor control; Sensory feedback; Sensory substitution; Tactile afferents

Indexed keywords

ADULT; ARTICLE; FEMALE; HAND GRIP; HAND PROSTHESIS; HEALTH CARE POLICY; HUMAN; HUMAN EXPERIMENT; INDEX FINGER; LEFT HANDEDNESS; LIFTING EFFORT; MALE; NORMAL HUMAN; RIGHT HANDEDNESS; ROBOTIC EXOSKELETON; SENSORIMOTOR FUNCTION; SENSORY FEEDBACK; TACTILE FEEDBACK; HAND; HAND STRENGTH; LEARNING; MOVEMENT (PHYSIOLOGY); MUSCLE STRENGTH; PHYSIOLOGY; PSYCHOMOTOR PERFORMANCE; ROBOTICS; TIME; TOUCH; YOUNG ADULT;

EID: 84926452678     PISSN: 00144819     EISSN: 14321106     Source Type: Journal    
DOI: 10.1007/s00221-014-4024-8     Document Type: Article
Times cited : (67)

References (29)
  • 1
    • 84865973189 scopus 로고    scopus 로고
    • Sensory feedback from a prosthetic hand based on air-mediated pressure from the hand to the forearm skin
    • PID: 22729800
    • Antfolk C, Bjorkman A, Frank SO, Sebelius F, Lundborg G, Rosen B (2012) Sensory feedback from a prosthetic hand based on air-mediated pressure from the hand to the forearm skin. J Rehabil Med 44(8):702–707
    • (2012) J Rehabil Med , vol.44 , Issue.8 , pp. 702-707
    • Antfolk, C.1    Bjorkman, A.2    Frank, S.O.3    Sebelius, F.4    Lundborg, G.5    Rosen, B.6
  • 3
    • 41849087742 scopus 로고    scopus 로고
    • Testing a prosthetic haptic feedback simulator with an interactive force matching task
    • Chatterjee A, Chaubey P, Martin J, Thakor N (2008) Testing a prosthetic haptic feedback simulator with an interactive force matching task. J Prosthet Orthot 20(2):27–34
    • (2008) J Prosthet Orthot , vol.20 , Issue.2 , pp. 27-34
    • Chatterjee, A.1    Chaubey, P.2    Martin, J.3    Thakor, N.4
  • 4
    • 0019300990 scopus 로고
    • Closed-loop control in prosthetic systems: historical perspective
    • PID: 7027836, COI: 1:STN:280:DyaL38%2FksVWiug%3D%3D
    • Childress DS (1980) Closed-loop control in prosthetic systems: historical perspective. Ann Biomed Eng 8(4–6):293–303
    • (1980) Ann Biomed Eng , vol.8 , Issue.4-6 , pp. 293-303
    • Childress, D.S.1
  • 5
    • 40949129655 scopus 로고    scopus 로고
    • On the shared control of an EMG-controlled prosthetic hand: analysis of user–prosthesis interaction
    • Cipriani C, Zaccone F, Micera S, Carrozza MC (2008) On the shared control of an EMG-controlled prosthetic hand: analysis of user–prosthesis interaction. IEEE Trans Robot 24(1):170–184
    • (2008) IEEE Trans Robot , vol.24 , Issue.1 , pp. 170-184
    • Cipriani, C.1    Zaccone, F.2    Micera, S.3    Carrozza, M.C.4
  • 7
    • 84856201341 scopus 로고    scopus 로고
    • A miniature vibrotactile sensory substitution device for multifingered hand prosthetics
    • PID: 22042125
    • Cipriani C, D’Alonzo M, Carrozza MC (2012) A miniature vibrotactile sensory substitution device for multifingered hand prosthetics. IEEE Trans Biomed Eng 59(2):400–408
    • (2012) IEEE Trans Biomed Eng , vol.59 , Issue.2 , pp. 400-408
    • Cipriani, C.1    D’Alonzo, M.2    Carrozza, M.C.3
  • 8
    • 29644439037 scopus 로고    scopus 로고
    • Direct neural sensory feedback and control of a prosthetic arm
    • PID: 16425828
    • Dhillon GS, Horch KW (2005) Direct neural sensory feedback and control of a prosthetic arm. IEEE Trans Neural Syst Rehabil Eng 13(4):468–472
    • (2005) IEEE Trans Neural Syst Rehabil Eng , vol.13 , Issue.4 , pp. 468-472
    • Dhillon, G.S.1    Horch, K.W.2
  • 9
    • 33751225937 scopus 로고    scopus 로고
    • Control strategies in object manipulation tasks
    • PID: 17084619, COI: 1:CAS:528:DC%2BD28Xht1Cls7vO
    • Flanagan JR, Bowman MC, Johansson RS (2006) Control strategies in object manipulation tasks. Curr Opin Neurobiol 16:650–659
    • (2006) Curr Opin Neurobiol , vol.16 , pp. 650-659
    • Flanagan, J.R.1    Bowman, M.C.2    Johansson, R.S.3
  • 10
    • 0027158772 scopus 로고
    • Memory representations underlying motor commands used during manipulation of common and novel objects
    • PID: 8350123, COI: 1:STN:280:DyaK3szltlahsg%3D%3D
    • Gordon AM, Westling G, Cole KJ, Johansson RS (1993) Memory representations underlying motor commands used during manipulation of common and novel objects. J Neurophysiol 69:1789–1796
    • (1993) J Neurophysiol , vol.69 , pp. 1789-1796
    • Gordon, A.M.1    Westling, G.2    Cole, K.J.3    Johansson, R.S.4
  • 12
    • 80054062765 scopus 로고    scopus 로고
    • Object discrimination with an artificial hand using electrical stimulation of peripheral tactile and proprioceptive pathways with intrafascicular electrodes
    • PID: 21859607
    • Horch K, Meek S, Taylor TG, Hutchinson DT (2011) Object discrimination with an artificial hand using electrical stimulation of peripheral tactile and proprioceptive pathways with intrafascicular electrodes. IEEE Trans Neural Syst Rehabil Eng 19(5):483–489
    • (2011) IEEE Trans Neural Syst Rehabil Eng , vol.19 , Issue.5 , pp. 483-489
    • Horch, K.1    Meek, S.2    Taylor, T.G.3    Hutchinson, D.T.4
  • 13
    • 0027816190 scopus 로고
    • Predictive feed-forward sensory control during grasping and manipulation in man
    • Johansson RS, Edin BB (1993) Predictive feed-forward sensory control during grasping and manipulation in man. Biomed Res 14(4):95–106
    • (1993) Biomed Res , vol.14 , Issue.4 , pp. 95-106
    • Johansson, R.S.1    Edin, B.B.2
  • 14
    • 0021200173 scopus 로고
    • Roles of glabrous skin receptors and sensorimotor memory in automatic control of precision grip when lifting rougher or more slippery objects
    • PID: 6499981, COI: 1:STN:280:DyaL2M%2FltFOjtg%3D%3D
    • Johansson RS, Westling G (1984) Roles of glabrous skin receptors and sensorimotor memory in automatic control of precision grip when lifting rougher or more slippery objects. Exp Brain Res 56:550–564
    • (1984) Exp Brain Res , vol.56 , pp. 550-564
    • Johansson, R.S.1    Westling, G.2
  • 15
    • 0002215384 scopus 로고
    • Afferent signals during manipulative tasks in man
    • Franzen O, Westman J, (eds), Macmillan Press, London:
    • Johansson RS, Westling G (1991) Afferent signals during manipulative tasks in man. In: Franzen O, Westman J (eds) Somatosensory mechanisms. Macmillan Press, London, pp 25–48
    • (1991) Somatosensory mechanisms , pp. 25-48
    • Johansson, R.S.1    Westling, G.2
  • 16
    • 0347984996 scopus 로고    scopus 로고
    • Richard P. Bunge memorial lecture. Nerve injury and repair—a challenge to the plastic brain
    • PID: 14641646
    • Lundborg G (2003) Richard P. Bunge memorial lecture. Nerve injury and repair—a challenge to the plastic brain. J Peripher Nerv Syst 8:209–226
    • (2003) J Peripher Nerv Syst , vol.8 , pp. 209-226
    • Lundborg, G.1
  • 17
    • 0014747486 scopus 로고
    • Kinesthetic sensing for the EMG controlled Boston Arm
    • Mann RW, Reimers SD (1970) Kinesthetic sensing for the EMG controlled Boston Arm. IEEE Trans Man–Mach Syst 11(1):110–115
    • (1970) IEEE Trans Man–Mach Syst , vol.11 , Issue.1 , pp. 110-115
    • Mann, R.W.1    Reimers, S.D.2
  • 18
    • 0024676405 scopus 로고
    • Extended physiologic taction: design and evaluation of a proportional force feedback system
    • PID: 2666644, COI: 1:STN:280:DyaL1MzivVyguw%3D%3D
    • Meek SG, Jacobsen SC, Goulding PP (1989) Extended physiologic taction: design and evaluation of a proportional force feedback system. J Rehabil Res Dev 26(3):53–62
    • (1989) J Rehabil Res Dev , vol.26 , Issue.3 , pp. 53-62
    • Meek, S.G.1    Jacobsen, S.C.2    Goulding, P.P.3
  • 20
    • 0028129268 scopus 로고
    • Nerve repair: correlation of restitution of functional sensibility with specific cognitive capacities
    • Rosén B, Lundborg G, Dahlin LB, Holmberg J, Karlson B (1994) Nerve repair: correlation of restitution of functional sensibility with specific cognitive capacities. J Hand Surg 19:452–458
    • (1994) J Hand Surg , vol.19 , pp. 452-458
    • Rosén, B.1    Lundborg, G.2    Dahlin, L.B.3    Holmberg, J.4    Karlson, B.5
  • 21
    • 77949422852 scopus 로고    scopus 로고
    • Double nerve intraneural interface implant on a human amputee for robotic hand control
    • PID: 20110193
    • Rossini PM, Micera S, Benvenuto A et al (2010) Double nerve intraneural interface implant on a human amputee for robotic hand control. Clin Neurophysiol 121(5):777–783
    • (2010) Clin Neurophysiol , vol.121 , Issue.5 , pp. 777-783
    • Rossini, P.M.1    Micera, S.2    Benvenuto, A.3
  • 23
    • 80054943371 scopus 로고    scopus 로고
    • The role of feed-forward and feedback processes for closed-loop prosthesis control
    • Saunders I, Vijayakumar S (2011) The role of feed-forward and feedback processes for closed-loop prosthesis control. J Neuroeng Rehabil 8(60):1–12
    • (2011) J Neuroeng Rehabil , vol.8 , Issue.60 , pp. 1-12
    • Saunders, I.1    Vijayakumar, S.2
  • 24
    • 70449514793 scopus 로고    scopus 로고
    • Examination of force discrimination in human upper limb amputees with reinnervated limb sensation following peripheral nerve transfer
    • PID: 19775983
    • Sensinger JW, Schultz AE, Kuiken TA (2009) Examination of force discrimination in human upper limb amputees with reinnervated limb sensation following peripheral nerve transfer. IEEE Trans Neural Syst Rehabil Eng 17(5):438–444
    • (2009) IEEE Trans Neural Syst Rehabil Eng , vol.17 , Issue.5 , pp. 438-444
    • Sensinger, J.W.1    Schultz, A.E.2    Kuiken, T.A.3
  • 25
    • 84857590738 scopus 로고    scopus 로고
    • Repeated training with augmentative vibrotactile feedback increases object manipulation performance
    • PID: 22384283, COI: 1:CAS:528:DC%2BC38XjsFyksb0%3D
    • Stepp CE, An Q, Matsuoka Y (2012) Repeated training with augmentative vibrotactile feedback increases object manipulation performance. PLoS One 7(2):e32743. doi:10.1371/journal.pone.0032743
    • (2012) PLoS One , vol.7 , Issue.2 , pp. e32743
    • Stepp, C.E.1    An, Q.2    Matsuoka, Y.3
  • 26
    • 0020116505 scopus 로고
    • Electrocutaneous stimulation for sensory communication in rehabilitation engineering
    • Szeto AY, Saunders FA (1982) Electrocutaneous stimulation for sensory communication in rehabilitation engineering. IEEE Trans Biomed Eng 4:300–308
    • (1982) IEEE Trans Biomed Eng , vol.4 , pp. 300-308
    • Szeto, A.Y.1    Saunders, F.A.2
  • 27
    • 84897728587 scopus 로고    scopus 로고
    • Stability and selectivity of a chronic, multi-contact cuff electrode for sensory stimulation in a human amputee. In: International IEEE/EMBS Conference on Neural Engineering (NER)
    • Tan D, Schiefer M, Keith MW, Anderson R, Tyler DJ (2013) Stability and selectivity of a chronic, multi-contact cuff electrode for sensory stimulation in a human amputee. In: International IEEE/EMBS Conference on Neural Engineering (NER), pp 859–862
    • (2013) pp 859–862
    • Tan, D.1    Schiefer, M.2    Keith, M.W.3    Anderson, R.4    Tyler, D.J.5
  • 28
    • 14544272833 scopus 로고    scopus 로고
    • The rubber hand illusion revisited: visuotactile integration and self-attribution
    • Tsakiris M, Haggard P (2005) The rubber hand illusion revisited: visuotactile integration and self-attribution. J Exp Psychol Hum Percept Perform 3:80–91
    • (2005) J Exp Psychol Hum Percept Perform , vol.3 , pp. 80-91
    • Tsakiris, M.1    Haggard, P.2
  • 29
    • 0023143494 scopus 로고
    • Responses in glabrous skin mechanoreceptors during precision grip in humans
    • PID: 3582527, COI: 1:STN:280:DyaL2s3hvVyqtw%3D%3D
    • Westling G, Johansson RS (1987) Responses in glabrous skin mechanoreceptors during precision grip in humans. Exp Brain Res 66:128–140
    • (1987) Exp Brain Res , vol.66 , pp. 128-140
    • Westling, G.1    Johansson, R.S.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.