메뉴 건너뛰기




Volumn 11, Issue 7, 2016, Pages

Accuracy of intraoral digital impressions for whole upper jaws, including full dentitions and palatal soft tissues

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ARTICLE; COMPUTER PROGRAM; CONTROLLED STUDY; DENTAL IMPRESSION; DENTITION; DIGITAL IMAGING; FEMALE; HUMAN; HUMAN EXPERIMENT; IN VIVO STUDY; MALE; MAXILLA; MEASUREMENT ACCURACY; MEASUREMENT PRECISION; NORMAL HUMAN; PALATE; THREE DIMENSIONAL IMAGING; TOOTH ARCH; ANATOMY AND HISTOLOGY; COMPUTER AIDED DESIGN; DENTAL PROCEDURE; DEVICES; IMAGE PROCESSING; PROCEDURES; REPRODUCIBILITY; SOFTWARE; STANDARDS; TOOTH; YOUNG ADULT;

EID: 84978062169     PISSN: None     EISSN: 19326203     Source Type: Journal    
DOI: 10.1371/journal.pone.0158800     Document Type: Article
Times cited : (113)

References (24)
  • 1
    • 84881612097 scopus 로고    scopus 로고
    • Accuracy of digital and conventional impression techniques and workflow
    • PMID: 23086333
    • Seelbach P, Brueckel C, Wostmann B. Accuracy of digital and conventional impression techniques and workflow. Clin Oral Investig. 2013; 17(7):1759-64. doi: 10.1007/s00784-012-0864-4 PMID: 23086333
    • (2013) Clin Oral Investig , vol.17 , Issue.7 , pp. 1759-1764
    • Seelbach, P.1    Brueckel, C.2    Wostmann, B.3
  • 2
    • 77957280346 scopus 로고    scopus 로고
    • Clinical evaluation of all-ceramic crowns fabricated from intraoral digital impressions based on the principle of active wavefront sampling
    • PMID: 20381576
    • Syrek A, Reich G, Ranftl D, Klein C, Cerny B, Brodesser J. Clinical evaluation of all-ceramic crowns fabricated from intraoral digital impressions based on the principle of active wavefront sampling. J Dent. 2010; 38(7):553-9. doi: 10.1016/j.jdent.2010.03.015 PMID: 20381576
    • (2010) J Dent , vol.38 , Issue.7 , pp. 553-559
    • Syrek, A.1    Reich, G.2    Ranftl, D.3    Klein, C.4    Cerny, B.5    Brodesser, J.6
  • 3
    • 84888638427 scopus 로고    scopus 로고
    • The clinical accuracy of single crowns exclusively fabricated by digital workflow - The comparison of two systems
    • PMID: 23371756
    • Brawek PK, Wolfart S, Endres L, Kirsten A, Reich S. The clinical accuracy of single crowns exclusively fabricated by digital workflow - the comparison of two systems. Clin Oral Investig. 2013; 17(9):2119-25. doi: 10.1007/s00784-013-0923-5 PMID: 23371756
    • (2013) Clin Oral Investig , vol.17 , Issue.9 , pp. 2119-2125
    • Brawek, P.K.1    Wolfart, S.2    Endres, L.3    Kirsten, A.4    Reich, S.5
  • 4
    • 84881026847 scopus 로고    scopus 로고
    • A clinical protocol for intraoral digital impression of screw-retained CAD/CAM framework on multiple implants based on wavefront sampling technology
    • PMID: 23817542
    • Moreno A, Gimenez B, Ozcan M, Pradies G. A clinical protocol for intraoral digital impression of screw-retained CAD/CAM framework on multiple implants based on wavefront sampling technology. Implant dentistry. 2013; 22(4):320-5. doi: 10.1097/ID.0b013e3182980fe9 PMID: 23817542
    • (2013) Implant Dentistry , vol.22 , Issue.4 , pp. 320-325
    • Moreno, A.1    Gimenez, B.2    Ozcan, M.3    Pradies, G.4
  • 5
    • 84928213705 scopus 로고    scopus 로고
    • Accuracy of digital versus conventional implant impressions
    • PMID: 24720423
    • Lee SJ, Betensky RA, Gianneschi GE, Gallucci GO. Accuracy of digital versus conventional implant impressions. Clin Oral Implants Res. 2015; 26(6):715-9. doi: 10.1111/clr.12375 PMID: 24720423
    • (2015) Clin Oral Implants Res , vol.26 , Issue.6 , pp. 715-719
    • Lee, S.J.1    Betensky, R.A.2    Gianneschi, G.E.3    Gallucci, G.O.4
  • 6
    • 84855567898 scopus 로고    scopus 로고
    • CAD/CAM fabricated complete dentures: Concepts and clinical methods of obtaining required morphological data
    • PMID: 22230914
    • Goodacre CJ, Garbacea A, Naylor WP, Daher T, Marchack CB, Lowry J. CAD/CAM fabricated complete dentures: concepts and clinical methods of obtaining required morphological data. The Journal of prosthetic dentistry. 2012; 107(1):34-46. doi: 10.1016/S0022-3913(12)60015-8 PMID: 22230914
    • (2012) The Journal of Prosthetic Dentistry , vol.107 , Issue.1 , pp. 34-46
    • Goodacre, C.J.1    Garbacea, A.2    Naylor, W.P.3    Daher, T.4    Marchack, C.B.5    Lowry, J.6
  • 7
    • 84908553900 scopus 로고    scopus 로고
    • Rehabilitation of maxillectomy defects with obturator prostheses fabricated using computer-aided design and rapid prototyping: A pilot study
    • PMID: 25191895
    • Jiao T, Zhu C, Dong X, Gu X. Rehabilitation of maxillectomy defects with obturator prostheses fabricated using computer-aided design and rapid prototyping: a pilot study. Int J Prosthodont. 2014; 27(5):480-6. doi: 10.11607/ijp.3733 PMID: 25191895
    • (2014) Int J Prosthodont , vol.27 , Issue.5 , pp. 480-486
    • Jiao, T.1    Zhu, C.2    Dong, X.3    Gu, X.4
  • 8
    • 84978050772 scopus 로고    scopus 로고
    • The official website of
    • The official website of 3 Shape Corporation. Available: http://www.3shape.com/en/new+products/dental+labs/lab+scanners.
  • 9
    • 84886412061 scopus 로고    scopus 로고
    • Precision of intraoral digital dental impressions with iTero and extraoral digitization with the iTero and a model scanner
    • PMID: 23992820
    • Flugge TV, Schlager S, Nelson K, Nahles S, Metzger MC. Precision of intraoral digital dental impressions with iTero and extraoral digitization with the iTero and a model scanner. Am J Orthod Dentofacial Orthop. 2013; 144(3):471-8. doi: 10.1016/j.ajodo.2013.04.017 PMID: 23992820
    • (2013) Am J Orthod Dentofacial Orthop , vol.144 , Issue.3 , pp. 471-478
    • Flugge, T.V.1    Schlager, S.2    Nelson, K.3    Nahles, S.4    Metzger, M.C.5
  • 10
    • 36048966648 scopus 로고    scopus 로고
    • Direct mechanical data acquisition of dental impressions for the manufacturing of CAD/CAM restorations
    • PMID: 17980951
    • Quaas S, Rudolph H, Luthardt RG. Direct mechanical data acquisition of dental impressions for the manufacturing of CAD/CAM restorations. Journal of dentistry. 2007; 35(12):903-8. PMID: 17980951
    • (2007) Journal of Dentistry , vol.35 , Issue.12 , pp. 903-908
    • Quaas, S.1    Rudolph, H.2    Luthardt, R.G.3
  • 11
    • 84897902654 scopus 로고    scopus 로고
    • Marginal and internal fit of cobalt-chromium fixed dental prostheses generated from digital and conventional impressions
    • PMID: 24723954
    • Svanborg P, Skjerven H, Carlsson P, Eliasson A, Karlsson S, Ortorp A. Marginal and internal fit of cobalt-chromium fixed dental prostheses generated from digital and conventional impressions. Int J Dent. 2014; 2014:534382. doi: 10.1155/2014/534382 PMID: 24723954
    • (2014) Int J Dent , vol.2014
    • Svanborg, P.1    Skjerven, H.2    Carlsson, P.3    Eliasson, A.4    Karlsson, S.5    Ortorp, A.6
  • 12
    • 84894547254 scopus 로고    scopus 로고
    • Marginal and internal fit of four-unit zirconia fixed dental prostheses based on digital and conventional impression techniques
    • PMID: 23716064
    • Almeida e Silva JS, Erdelt K, Edelhoff D, Araujo E, Stimmelmayr M, Vieira LC, et al. Marginal and internal fit of four-unit zirconia fixed dental prostheses based on digital and conventional impression techniques. Clin Oral Investig. 2014; 18(2):515-23. doi: 10.1007/s00784-013-0987-2 PMID: 23716064
    • (2014) Clin Oral Investig , vol.18 , Issue.2 , pp. 515-523
    • Almeida E Silva, J.S.1    Erdelt, K.2    Edelhoff, D.3    Araujo, E.4    Stimmelmayr, M.5    Vieira, L.C.6
  • 13
    • 84955241809 scopus 로고    scopus 로고
    • Influence of conventional and digital intraoral impressions on the fit of CAD/CAM-fabricated all-ceramic crowns
    • Berrendero S, Salido MP, Valverde A, Ferreiroa A, Pradies G. Influence of conventional and digital intraoral impressions on the fit of CAD/CAM-fabricated all-ceramic crowns. Clin Oral Investig. 2016.
    • (2016) Clin Oral Investig
    • Berrendero, S.1    Salido, M.P.2    Valverde, A.3    Ferreiroa, A.4    Pradies, G.5
  • 14
    • 85027909273 scopus 로고    scopus 로고
    • Intraoral Digital Impression Technique Compared to Conventional Impression Technique. A Randomized Clinical Trial
    • Gjelvold B, Chrcanovic BR, Korduner EK, Collin-Bagewitz I, Kisch J. Intraoral Digital Impression Technique Compared to Conventional Impression Technique. A Randomized Clinical Trial. J Prosthodont. 2015.
    • (2015) J Prosthodont
    • Gjelvold, B.1    Chrcanovic, B.R.2    Korduner, E.K.3    Collin-Bagewitz, I.4    Kisch, J.5
  • 15
    • 84883430030 scopus 로고    scopus 로고
    • Assessing the feasibility and accuracy of digitizing edentulous jaws
    • PMID: 23904578
    • Patzelt SB, Vonau S, Stampf S, Att W. Assessing the feasibility and accuracy of digitizing edentulous jaws. Journal of the American Dental Association. 2013; 144(8):914-920. PMID: 23904578
    • (2013) Journal of the American Dental Association , vol.144 , Issue.8 , pp. 914-920
    • Patzelt, S.B.1    Vonau, S.2    Stampf, S.3    Att, W.4
  • 16
    • 84906810234 scopus 로고    scopus 로고
    • Intraoral scanning of hard and soft tissues for partial removable dental prosthesis fabrication
    • PMID: 24882595
    • Kattadiyil MT, Mursic Z, AlRumaih H, Goodacre CJ. Intraoral scanning of hard and soft tissues for partial removable dental prosthesis fabrication. J Prosthet Dent. 2014; 112(3):444-8. doi: 10.1016/j.prosdent.2014.03.022 PMID: 24882595
    • (2014) J Prosthet Dent , vol.112 , Issue.3 , pp. 444-448
    • Kattadiyil, M.T.1    Mursic, Z.2    AlRumaih, H.3    Goodacre, C.J.4
  • 17
    • 84865754138 scopus 로고    scopus 로고
    • Delayed linear dimensional changes of five high strength gypsum products used for the fabrication of definitive casts
    • PMID: 22944315
    • Michalakis KX, Asar NV, Kapsampeli V, Magkavali-Trikka P, Pissiotis AL, Hirayama H. Delayed linear dimensional changes of five high strength gypsum products used for the fabrication of definitive casts. The Journal of prosthetic dentistry. 2012; 108(3):189-95. doi: 10.1016/S0022-3913(12)60146-2 PMID: 22944315
    • (2012) The Journal of Prosthetic Dentistry , vol.108 , Issue.3 , pp. 189-195
    • Michalakis, K.X.1    Asar, N.V.2    Kapsampeli, V.3    Magkavali-Trikka, P.4    Pissiotis, A.L.5    Hirayama, H.6
  • 18
    • 61849146359 scopus 로고    scopus 로고
    • Influence of width and depth of palatal vault on rigidity of palatal strap: A finite element study
    • PMID: 19318080
    • Takanashi T, Shimamura I, Sakurai K. Influence of width and depth of palatal vault on rigidity of palatal strap: a finite element study. J Prosthodont Res. 2009; 53(2):95-100. doi: 10.1016/j.jpor.2008.10.002 PMID: 19318080
    • (2009) J Prosthodont Res , vol.53 , Issue.2 , pp. 95-100
    • Takanashi, T.1    Shimamura, I.2    Sakurai, K.3
  • 20
    • 84873578014 scopus 로고    scopus 로고
    • Accuracy of complete-arch dental impressions: A new method of measuring trueness and precision
    • PMID: 23395338
    • Ender A, Mehl A. Accuracy of complete-arch dental impressions: A new method of measuring trueness and precision. The Journal of Prosthetic Dentistry. 2013; 109(2):121-8. doi: 10.1016/S0022-3913(13)60028-1 PMID: 23395338
    • (2013) The Journal of Prosthetic Dentistry , vol.109 , Issue.2 , pp. 121-128
    • Ender, A.1    Mehl, A.2
  • 21
    • 84978162505 scopus 로고    scopus 로고
    • People's Medical Publishing House. Chapter 16
    • Yan H, Xu YY, Zhao NQ. Medical Statistics, People's Medical Publishing House. 2005;Chapter 16, pp.258, ISBN:7117069082.
    • (2005) Medical Statistics , pp. 258
    • Yan, H.1    Xu, Y.Y.2    Zhao, N.Q.3
  • 22
    • 84944175820 scopus 로고    scopus 로고
    • Comparison of repeatability between intraoral digital scanner and extraoral digital scanner: An in-vitro study
    • Su TS, Sun J. Comparison of repeatability between intraoral digital scanner and extraoral digital scanner: An in-vitro study. Journal of prosthodontic research. 2015.
    • (2015) Journal of Prosthodontic Research
    • Su, T.S.1    Sun, J.2
  • 24
    • 33947147250 scopus 로고    scopus 로고
    • Computer-aided analysis of the influence of digitizing and surfacing on the accuracy in dental CAD/CAM technology
    • PMID: 16844107
    • Rudolph H, Luthardt RG, Walter MH. Computer-aided analysis of the influence of digitizing and surfacing on the accuracy in dental CAD/CAM technology. Computers in Biology and Medicine. 2007; 37(5):579-87. PMID: 16844107
    • (2007) Computers in Biology and Medicine , vol.37 , Issue.5 , pp. 579-587
    • Rudolph, H.1    Luthardt, R.G.2    Walter, M.H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.