메뉴 건너뛰기




Volumn 37, Issue 7, 2016, Pages 2385-2397

Subtle in-scanner motion biases automated measurement of brain anatomy from in vivo MRI

Author keywords

bias; cortical curvature; cortical surface area; cortical thickness; functional neuroimaging; magnetic resonance imaging; motion

Indexed keywords

ADOLESCENT; ADULT; ARTICLE; BRAIN; BRAIN CORTEX; BRAIN SIZE; CHILD; CONVERGENT VALIDITY; CORTICAL CURVATURE; CORTICAL THICKNESS (BRAIN); FEMALE; FUNCTIONAL MAGNETIC RESONANCE IMAGING; FUNCTIONAL NEUROIMAGING; GRAY MATTER; HUMAN; IN SCANNER MOTION BIAS; IN VIVO STUDY; INFORMATION PROCESSING BIAS; MALE; NERVOUS SYSTEM PARAMETERS; NEUROANATOMY; NUCLEAR MAGNETIC RESONANCE SCANNER; PRIORITY JOURNAL; YOUNG ADULT;

EID: 84974711219     PISSN: 10659471     EISSN: 10970193     Source Type: Journal    
DOI: 10.1002/hbm.23180     Document Type: Article
Times cited : (132)

References (62)
  • 1
    • 0031283439 scopus 로고    scopus 로고
    • Automatic correction of motion artifacts in magnetic resonance images using an entropy focus criterion
    • Atkinson D, Hill DL, Stoyle PN, Summers PE, Keevil SF (1997): Automatic correction of motion artifacts in magnetic resonance images using an entropy focus criterion. IEEE Trans Med Imaging 16:903–910.
    • (1997) IEEE Trans Med Imaging , vol.16 , pp. 903-910
    • Atkinson, D.1    Hill, D.L.2    Stoyle, P.N.3    Summers, P.E.4    Keevil, S.F.5
  • 3
    • 33746197428 scopus 로고    scopus 로고
    • Adaptive linear step-up procedures that control the false discovery rate
    • Benjamini Y, Krieger AM, Yekutieli D (2006): Adaptive linear step-up procedures that control the false discovery rate. Biometrika 93:491–507.
    • (2006) Biometrika , vol.93 , pp. 491-507
    • Benjamini, Y.1    Krieger, A.M.2    Yekutieli, D.3
  • 4
    • 0036331288 scopus 로고    scopus 로고
    • Motion artifact in magnetic resonance imaging: Implications for automated analysis
    • Blumenthal JD, Zijdenbos A, Molloy E, Giedd JN (2002): Motion artifact in magnetic resonance imaging: Implications for automated analysis. NeuroImage 16:89–92.
    • (2002) NeuroImage , vol.16 , pp. 89-92
    • Blumenthal, J.D.1    Zijdenbos, A.2    Molloy, E.3    Giedd, J.N.4
  • 6
    • 0028287162 scopus 로고
    • Automatic 3D intersubject registration of MR volumetric data in standardized Talairach space
    • Collins DL, Neelin P, Peters TM, Evans AC (1994): Automatic 3D intersubject registration of MR volumetric data in standardized Talairach space. J Comput Assist Tomogr 18:192–205.
    • (1994) J Comput Assist Tomogr , vol.18 , pp. 192-205
    • Collins, D.L.1    Neelin, P.2    Peters, T.M.3    Evans, A.C.4
  • 7
    • 0030175198 scopus 로고    scopus 로고
    • AFNI: Software for analysis and visualization of functional magnetic resonance neuroimages
    • Cox RW (1996): AFNI: Software for analysis and visualization of functional magnetic resonance neuroimages. Comput Biomed Res 29:162–173.
    • (1996) Comput Biomed Res , vol.29 , pp. 162-173
    • Cox, R.W.1
  • 8
    • 0032736320 scopus 로고    scopus 로고
    • Real-time 3D image registration for functional MRI
    • Cox RW, Jesmanowicz A (1999): Real-time 3D image registration for functional MRI. Magn Reson Med 42:1014–1018.
    • (1999) Magn Reson Med , vol.42 , pp. 1014-1018
    • Cox, R.W.1    Jesmanowicz, A.2
  • 9
    • 0032769093 scopus 로고    scopus 로고
    • Cortical surface-based analysis. I. Segmentation and surface reconstruction
    • Dale AM, Fischl B, Sereno MI (1999): Cortical surface-based analysis. I. Segmentation and surface reconstruction. NeuroImage 9:179–194.
    • (1999) NeuroImage , vol.9 , pp. 179-194
    • Dale, A.M.1    Fischl, B.2    Sereno, M.I.3
  • 12
    • 84947938213 scopus 로고    scopus 로고
    • Trajectories of cortical thickness maturation in normal brain development - The importance of quality control procedures
    • Ducharme S, Albaugh MD, Nguyen T-V, Hudziak JJ, Mateos-Pérez JM, Labbe A, Evans AC, Karama S, Brain Development Cooperative Group (2015): Trajectories of cortical thickness maturation in normal brain development - The importance of quality control procedures. NeuroImage 125:267–279.
    • (2015) NeuroImage , vol.125 , pp. 267-279
    • Ducharme, S.1    Albaugh, M.D.2    Nguyen, T.-V.3    Hudziak, J.J.4    Mateos-Pérez, J.M.5    Labbe, A.6    Evans, A.C.7    Karama, S.8
  • 13
    • 0024453449 scopus 로고
    • Adaptive technique for high-definition MR imaging of moving structures
    • Ehman RL, Felmlee JP (1989): Adaptive technique for high-definition MR imaging of moving structures. Radiology 173:255–263.
    • (1989) Radiology , vol.173 , pp. 255-263
    • Ehman, R.L.1    Felmlee, J.P.2
  • 14
    • 0034744999 scopus 로고    scopus 로고
    • Automated manifold surgery: Constructing geometrically accurate and topologically correct models of the human cerebral cortex
    • Fischl B, Liu A, Dale AM (2001): Automated manifold surgery: Constructing geometrically accurate and topologically correct models of the human cerebral cortex. IEEE Trans Med Imaging 20:70–80.
    • (2001) IEEE Trans Med Imaging , vol.20 , pp. 70-80
    • Fischl, B.1    Liu, A.2    Dale, A.M.3
  • 15
    • 0032799993 scopus 로고    scopus 로고
    • Cortical surface-based analysis. II: Inflation, flattening, and a surface-based coordinate system
    • Fischl B, Sereno MI, Dale AM (1999): Cortical surface-based analysis. II: Inflation, flattening, and a surface-based coordinate system. NeuroImage 9:195–207.
    • (1999) NeuroImage , vol.9 , pp. 195-207
    • Fischl, B.1    Sereno, M.I.2    Dale, A.M.3
  • 19
    • 0036557907 scopus 로고    scopus 로고
    • What is the best similarity measure for motion correction in fMRI time series?
    • Freire L, Roche A, Mangin JF (2002): What is the best similarity measure for motion correction in fMRI time series? IEEE Trans Med Imaging 21:470–484.
    • (2002) IEEE Trans Med Imaging , vol.21 , pp. 470-484
    • Freire, L.1    Roche, A.2    Mangin, J.F.3
  • 23
    • 33646590053 scopus 로고    scopus 로고
    • Gender difference analysis of cortical thickness in healthy young adults with surface-based methods
    • Im K, Lee J-M, Lee J, Shin Y-W, Kim I-Y, Kwon JS, Kim SI (2006): Gender difference analysis of cortical thickness in healthy young adults with surface-based methods. NeuroImage 31:31–38.
    • (2006) NeuroImage , vol.31 , pp. 31-38
    • Im, K.1    Lee, J.-M.2    Lee, J.3    Shin, Y.-W.4    Kim, I.-Y.5    Kwon, J.S.6    Kim, S.I.7
  • 25
    • 0035384136 scopus 로고    scopus 로고
    • A global optimisation method for robust affine registration of brain images
    • Jenkinson M, Smith S (2001): A global optimisation method for robust affine registration of brain images. Med Image Anal 5:143–156.
    • (2001) Med Image Anal , vol.5 , pp. 143-156
    • Jenkinson, M.1    Smith, S.2
  • 26
    • 0036425968 scopus 로고    scopus 로고
    • Improved optimization for the robust and accurate linear registration and motion correction of brain images
    • Jenkinson M, Bannister P, Brady M, Smith S (2002): Improved optimization for the robust and accurate linear registration and motion correction of brain images. NeuroImage 17:825–841.
    • (2002) NeuroImage , vol.17 , pp. 825-841
    • Jenkinson, M.1    Bannister, P.2    Brady, M.3    Smith, S.4
  • 27
    • 84880140628 scopus 로고    scopus 로고
    • Effective preprocessing procedures virtually eliminate distance-dependent motion artifacts in resting state FMRI
    • Jo HJ, Gotts SJ, Reynolds RC, Bandettini PA, Martin A, Cox RW, Saad ZS (2013): Effective preprocessing procedures virtually eliminate distance-dependent motion artifacts in resting state FMRI. J Appl Math 2013:935154.
    • (2013) J Appl Math , vol.2013 , pp. 935154
    • Jo, H.J.1    Gotts, S.J.2    Reynolds, R.C.3    Bandettini, P.A.4    Martin, A.5    Cox, R.W.6    Saad, Z.S.7
  • 30
    • 22044448620 scopus 로고    scopus 로고
    • Automated 3-D extraction and evaluation of the inner and outer cortical surfaces using a Laplacian map and partial volume effect classification
    • Kim JS, Singh V, Lee JK, Lerch J, Ad-Dab'bagh Y, MacDonald D, Lee J-M, Kim SI, Evans AC (2005): Automated 3-D extraction and evaluation of the inner and outer cortical surfaces using a Laplacian map and partial volume effect classification. NeuroImage 27:210–221.
    • (2005) NeuroImage , vol.27 , pp. 210-221
    • Kim, J.S.1    Singh, V.2    Lee, J.K.3    Lerch, J.4    Ad-Dab'bagh, Y.5    MacDonald, D.6    Lee, J.-M.7    Kim, S.I.8    Evans, A.C.9
  • 31
    • 0025040013 scopus 로고
    • Adaptive technique for three-dimensional MR imaging of moving structures
    • Korin HW, Felmlee JP, Ehman RL, Riederer SJ (1990): Adaptive technique for three-dimensional MR imaging of moving structures. Radiology 177:217–221.
    • (1990) Radiology , vol.177 , pp. 217-221
    • Korin, H.W.1    Felmlee, J.P.2    Ehman, R.L.3    Riederer, S.J.4
  • 33
    • 84907450916 scopus 로고    scopus 로고
    • Differentiating BOLD and non-BOLD signals in fMRI time series from anesthetized rats using multi-echo EPI at 11.7 T
    • Kundu P, Santin MD, Bandettini PA, Bullmore ET, Petiet A (2014): Differentiating BOLD and non-BOLD signals in fMRI time series from anesthetized rats using multi-echo EPI at 11.7 T. NeuroImage 102(Pt 2):861–874.
    • (2014) NeuroImage , vol.102Pt 2 , pp. 861-874
    • Kundu, P.1    Santin, M.D.2    Bandettini, P.A.3    Bullmore, E.T.4    Petiet, A.5
  • 35
    • 33748910620 scopus 로고    scopus 로고
    • Measurement of signal-to-noise and contrast-to-noise in the fBIRN multicenter imaging study
    • Magnotta VA, Friedman L, FIRST BIRN (2006): Measurement of signal-to-noise and contrast-to-noise in the fBIRN multicenter imaging study. J Digit Imaging 19:140–147.
    • (2006) J Digit Imaging , vol.19 , pp. 140-147
    • Magnotta, V.A.1    Friedman, L.2
  • 36
  • 37
    • 0033953459 scopus 로고    scopus 로고
    • Image metric-based correction (autocorrection) of motion effects: Analysis of image metrics
    • McGee KP, Manduca A, Felmlee JP, Riederer SJ, Ehman RL (2000): Image metric-based correction (autocorrection) of motion effects: Analysis of image metrics. J Magn Reson Imaging 11:174–181.
    • (2000) J Magn Reson Imaging , vol.11 , pp. 174-181
    • McGee, K.P.1    Manduca, A.2    Felmlee, J.P.3    Riederer, S.J.4    Ehman, R.L.5
  • 40
    • 0035029342 scopus 로고    scopus 로고
    • Online motion correction for diffusion-weighted imaging using navigator echoes: Application to RARE imaging without sensitivity loss
    • Norris D (2001): Online motion correction for diffusion-weighted imaging using navigator echoes: Application to RARE imaging without sensitivity loss. Magn Reson Med 45:729–733.
    • (2001) Magn Reson Med , vol.45 , pp. 729-733
    • Norris, D.1
  • 42
    • 70349611299 scopus 로고    scopus 로고
    • Prospective real-time correction for arbitrary head motion using active markers
    • Ooi MB, Krueger S, Thomas WJ, Swaminathan SV, Brown TR (2009): Prospective real-time correction for arbitrary head motion using active markers. Magn Reson Med 62:943–954.
    • (2009) Magn Reson Med , vol.62 , pp. 943-954
    • Ooi, M.B.1    Krueger, S.2    Thomas, W.J.3    Swaminathan, S.V.4    Brown, T.R.5
  • 44
    • 84855455705 scopus 로고    scopus 로고
    • Spurious but systematic correlations in functional connectivity MRI networks arise from subject motion
    • Power JD, Barnes KA, Snyder AZ, Schlaggar BL, Petersen SE (2012): Spurious but systematic correlations in functional connectivity MRI networks arise from subject motion. NeuroImage 59:2142–2154.
    • (2012) NeuroImage , vol.59 , pp. 2142-2154
    • Power, J.D.1    Barnes, K.A.2    Snyder, A.Z.3    Schlaggar, B.L.4    Petersen, S.E.5
  • 45
    • 33646138939 scopus 로고    scopus 로고
    • Common MRI acquisition non-idealities significantly impact the output of the boundary shift integral method of measuring brain atrophy on serial MRI
    • Preboske GM, Gunter JL, Ward CP, Jack CR (2006): Common MRI acquisition non-idealities significantly impact the output of the boundary shift integral method of measuring brain atrophy on serial MRI. NeuroImage 30:1196–1202.
    • (2006) NeuroImage , vol.30 , pp. 1196-1202
    • Preboske, G.M.1    Gunter, J.L.2    Ward, C.P.3    Jack, C.R.4
  • 46
    • 70349632622 scopus 로고    scopus 로고
    • Prospective head-movement correction for high-resolution MRI using an in-bore optical tracking system
    • Qin L, van Gelderen P, Derbyshire J (2009) Prospective head-movement correction for high-resolution MRI using an in-bore optical tracking system. Magn Reson Med 62:924–934.
    • (2009) Magn Reson Med , vol.62 , pp. 924-934
    • Qin, L.1    van Gelderen, P.2    Derbyshire, J.3
  • 50
    • 84940586290 scopus 로고    scopus 로고
    • From genes to folds: A review of cortical gyrification theory
    • Ronan L, Fletcher PC (2014): From genes to folds: A review of cortical gyrification theory. Brain Struct Funct 220:2475–2483.
    • (2014) Brain Struct Funct , vol.220 , pp. 2475-2483
    • Ronan, L.1    Fletcher, P.C.2
  • 51
    • 84856093663 scopus 로고    scopus 로고
    • Impact of in-scanner head motion on multiple measures of functional connectivity: Relevance for studies of neurodevelopment in youth
    • Satterthwaite TD, Wolf DH, Loughead J, Ruparel K, Elliott MA, Hakonarson H, Gur RC, Gur RE (2012): Impact of in-scanner head motion on multiple measures of functional connectivity: Relevance for studies of neurodevelopment in youth. NeuroImage 60:623–632.
    • (2012) NeuroImage , vol.60 , pp. 623-632
    • Satterthwaite, T.D.1    Wolf, D.H.2    Loughead, J.3    Ruparel, K.4    Elliott, M.A.5    Hakonarson, H.6    Gur, R.C.7    Gur, R.E.8
  • 53
    • 34047139895 scopus 로고    scopus 로고
    • Geometrically accurate topology-correction of cortical surfaces using nonseparating loops
    • Ségonne F, Pacheco J, Fischl B (2007): Geometrically accurate topology-correction of cortical surfaces using nonseparating loops. IEEE Trans Med Imaging 26:518–529.
    • (2007) IEEE Trans Med Imaging , vol.26 , pp. 518-529
    • Ségonne, F.1    Pacheco, J.2    Fischl, B.3
  • 54
    • 0031987382 scopus 로고    scopus 로고
    • A nonparametric method for automatic correction of intensity nonuniformity in MRI data
    • Sled JG, Zijdenbos AP, Evans AC (1998): A nonparametric method for automatic correction of intensity nonuniformity in MRI data. IEEE Trans Med Imaging 17:87–97.
    • (1998) IEEE Trans Med Imaging , vol.17 , pp. 87-97
    • Sled, J.G.1    Zijdenbos, A.P.2    Evans, A.C.3
  • 55
    • 4344635520 scopus 로고    scopus 로고
    • Fast and robust parameter estimation for statistical partial volume models in brain MRI
    • Tohka J, Zijdenbos A, Evans A (2004): Fast and robust parameter estimation for statistical partial volume models in brain MRI. NeuroImage 23:84–97.
    • (2004) NeuroImage , vol.23 , pp. 84-97
    • Tohka, J.1    Zijdenbos, A.2    Evans, A.3
  • 56
    • 33750610656 scopus 로고    scopus 로고
    • Real-time rigid body motion correction and shimming using cloverleaf navigators
    • van der Kouwe AJW, Benner T, Dale AM (2006): Real-time rigid body motion correction and shimming using cloverleaf navigators. Magn Reson Med 56:1019–1032.
    • (2006) Magn Reson Med , vol.56 , pp. 1019-1032
    • van der Kouwe, A.J.W.1    Benner, T.2    Dale, A.M.3
  • 57
    • 81155162516 scopus 로고    scopus 로고
    • The influence of head motion on intrinsic functional connectivity MRI
    • Van Dijk KRA, Sabuncu MR, Buckner RL (2012): The influence of head motion on intrinsic functional connectivity MRI. NeuroImage 59:431–438.
    • (2012) NeuroImage , vol.59 , pp. 431-438
    • Van Dijk, K.R.A.1    Sabuncu, M.R.2    Buckner, R.L.3
  • 58
    • 3442901934 scopus 로고    scopus 로고
    • Online motion correction for diffusion-weighted segmented-EPI and FLASH imaging
    • Weih KS, Driesel W, Mengershausen von M, Norris DG (2004): Online motion correction for diffusion-weighted segmented-EPI and FLASH imaging. Magma 16:277–283.
    • (2004) Magma , vol.16 , pp. 277-283
    • Weih, K.S.1    Driesel, W.2    Mengershausen von, M.3    Norris, D.G.4
  • 59
    • 0036136070 scopus 로고    scopus 로고
    • Spherical navigator echoes for full 3D rigid body motion measurement in MRI
    • Welch EB, Manduca A, Grimm RC, Ward HA, Jack CR (2002): Spherical navigator echoes for full 3D rigid body motion measurement in MRI. Magn Reson Med 47:32–41.
    • (2002) Magn Reson Med , vol.47 , pp. 32-41
    • Welch, E.B.1    Manduca, A.2    Grimm, R.C.3    Ward, H.A.4    Jack, C.R.5
  • 61
    • 0021958023 scopus 로고
    • MR image artifacts from periodic motion
    • Wood ML, Henkelman RM (1985): MR image artifacts from periodic motion. Med Phys 12:143–151.
    • (1985) Med Phys , vol.12 , pp. 143-151
    • Wood, M.L.1    Henkelman, R.M.2
  • 62
    • 33744908028 scopus 로고    scopus 로고
    • Magnetic resonance imaging of freely moving objects: Prospective real-time motion correction using an external optical motion tracking system
    • Zaitsev M, Dold C, Sakas G, Hennig J, Speck O (2006): Magnetic resonance imaging of freely moving objects: Prospective real-time motion correction using an external optical motion tracking system. NeuroImage 31:1038–1050.
    • (2006) NeuroImage , vol.31 , pp. 1038-1050
    • Zaitsev, M.1    Dold, C.2    Sakas, G.3    Hennig, J.4    Speck, O.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.