Volumn 30, Issue 2, 2006, Pages 436-443

Reliability in multi-site structural MRI studies: Effects of gradient non-linearity correction on phantom and human data

Author keywords

Gradient non linearity distortions; Human structural MRI; Multi site calibration

Indexed keywords

ADULT; ALGORITHM; ARTICLE; CONTROLLED STUDY; FEMALE; HUMAN; HUMAN EXPERIMENT; IMAGE ANALYSIS; MALE; MORPHOMETRICS; NEUROIMAGING; NONLINEAR SYSTEM; NORMAL HUMAN; NUCLEAR MAGNETIC RESONANCE IMAGING; PHANTOM; PRIORITY JOURNAL; RELIABILITY; REPRODUCIBILITY;

EID: 33645117322     PISSN: 10538119     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.neuroimage.2005.09.046     Document Type: Article
Times cited : (1041)

References (15)
  • 4
    • 0842283229 scopus 로고    scopus 로고
    • Imaging cerebral atrophy: Normal ageing to Alzheimer's disease
    • N.C. Fox, and J.M. Schott Imaging cerebral atrophy: normal ageing to Alzheimer's disease Lancet 363 2004 392 394 (Jan 31)
    • (2004) Lancet , vol.363 , pp. 392-394
    • Fox, N.C.1    Schott, J.M.2
  • 6
    • 4644278739 scopus 로고    scopus 로고
    • Use of spherical harmonic deconvolution methods to compensate for nonlinear gradient effects on MRI images
    • A. Janke, H. Zhao, G.J. Cowin, G.J. Galloway, and D.M. Doddrell Use of spherical harmonic deconvolution methods to compensate for nonlinear gradient effects on MRI images Magn. Reson. Med. 52 1 2004 115 122 (Jul)
    • (2004) Magn. Reson. Med. , vol.52 , Issue.1 , pp. 115-122
    • Janke, A.1    Zhao, H.2    Cowin, G.J.3    Galloway, G.J.4    Doddrell, D.M.5
  • 7
    • 33645117926 scopus 로고    scopus 로고
    • Characterization and Correction of Image Distortions in Multi-Site Structural MRI
    • Brain Morphology BIRN Biomedical Informatics Research Network.
    • Jovicich, J., Greve, D., Haley, E., Fischl, B., Dale, A., 2003. Brain Morphology BIRN Biomedical Informatics Research Network. Characterization and Correction of Image Distortions in Multi-Site Structural MRI. NeuroImage. 19; Suppl. 1 S45, p. 863.
    • (2003) NeuroImage , vol.19 , Issue.1 SUPPL. S45 , pp. 863
    • Jovicich, J.1    Greve, D.2    Haley, E.3    Fischl, B.4    Dale, A.5
  • 9
    • 0032992683 scopus 로고    scopus 로고
    • MRI geometric distortion: A simple approach to correcting the effects of non-linear gradient fields
    • S. Langlois, M. Desvignes, J.M. Constans, and M. Revenu MRI geometric distortion: a simple approach to correcting the effects of non-linear gradient fields J. Magn. Reson. Imaging 9 6 1999 821 831 (Jun)
    • (1999) J. Magn. Reson. Imaging , vol.9 , Issue.6 , pp. 821-831
    • Langlois, S.1    Desvignes, M.2    Constans, J.M.3    Revenu, M.4
  • 10
    • 7044284799 scopus 로고    scopus 로고
    • Computational anatomy: Shape, growth, and atrophy comparison via diffeomorphisms
    • M.I. Miller Computational anatomy: shape, growth, and atrophy comparison via diffeomorphisms NeuroImage 23 Suppl. 1 2004 S19 S33
    • (2004) NeuroImage , vol.23 , Issue.1 SUPPL.
    • Miller, M.I.1
  • 13
    • 10644266195 scopus 로고    scopus 로고
    • Geometric distortion in clinical MRI systems Part I: Evaluation using a 3 D phantom
    • D. Wang, W. Strugnell, G. Cowin, D.M. Doddrell, and R. Slaughter Geometric distortion in clinical MRI systems Part I: evaluation using a 3 D phantom Magn. Reson. Imaging 22 9 2004 1211 1221 (Nov)
    • (2004) Magn. Reson. Imaging , vol.22 , Issue.9 , pp. 1211-1221
    • Wang, D.1    Strugnell, W.2    Cowin, G.3    Doddrell, D.M.4    Slaughter, R.5
  • 14
    • 2042542085 scopus 로고    scopus 로고
    • A novel phantom and method for comprehensive 3-dimensional measurement and correction of geometric distortion in magnetic resonance imaging
    • D. Wang, D.M. Doddrell, and G. Cowin A novel phantom and method for comprehensive 3-dimensional measurement and correction of geometric distortion in magnetic resonance imaging Magn. Reson. Imaging 22 4 2004 529 542 (May)
    • (2004) Magn. Reson. Imaging , vol.22 , Issue.4 , pp. 529-542
    • Wang, D.1    Doddrell, D.M.2    Cowin, G.3
  • 15
    • 10644296409 scopus 로고    scopus 로고
    • Geometric distortion in clinical MRI systems Part II: Correction using a 3D phantom
    • D. Wang, W. Strugnell, G. Cowin, D.M. Doddrell, and R. Slaughter Geometric distortion in clinical MRI systems Part II: correction using a 3D phantom Magn. Reson. Imaging 22 9 2004 1223 1232 (Nov)
    • (2004) Magn. Reson. Imaging , vol.22 , Issue.9 , pp. 1223-1232
    • Wang, D.1    Strugnell, W.2    Cowin, G.3    Doddrell, D.M.4    Slaughter, R.5