메뉴 건너뛰기




Volumn 41, Issue 1, 1999, Pages 163-170

Automatic compensation of motion artifacts in MRI

Author keywords

Autofocus; Entropy; Motion correction; Post processing

Indexed keywords

ENTROPY; MAGNETIC RESONANCE IMAGING; RIGID STRUCTURES; SPACE FLIGHT;

EID: 0032904175     PISSN: 07403194     EISSN: None     Source Type: Journal    
DOI: 10.1002/(SICI)1522-2594(199901)41:1<163::AID-MRM23>3.0.CO;2-9     Document Type: Article
Times cited : (113)

References (13)
  • 1
    • 0024453449 scopus 로고
    • Adaptive technique for high-definition MR imaging of moving structures
    • Ehman RL, Felmlee JP. Adaptive technique for high-definition MR imaging of moving structures. Radiology 1989;173:225-263.
    • (1989) Radiology , vol.173 , pp. 225-263
    • Ehman, R.L.1    Felmlee, J.P.2
  • 4
    • 0029866438 scopus 로고    scopus 로고
    • Diffusion-weighted Interleaved Echo-Planar Imaging with a Pair of Orthogonal Navigator Echoes
    • Butts K, de Crespigny A, Pauly JM, Moseley M. Diffusion-weighted Interleaved Echo-Planar Imaging with a Pair of Orthogonal Navigator Echoes. Magn Reson Med 1996;35:763-770.
    • (1996) Magn Reson Med , vol.35 , pp. 763-770
    • Butts, K.1    De Crespigny, A.2    Pauly, J.M.3    Moseley, M.4
  • 6
    • 0031283439 scopus 로고    scopus 로고
    • Automatic correction of motion artefacts in magnetic resonance images using an entropy focus criterion
    • Atkinson D, Hill DLG, Stoyle PNR, Summers PE, Keevil SF. Automatic correction of motion artefacts in magnetic resonance images using an entropy focus criterion. IEEE Trans Med Imaging 1997;16:903-910.
    • (1997) IEEE Trans Med Imaging , vol.16 , pp. 903-910
    • Atkinson, D.1    Hill, D.L.G.2    Stoyle, P.N.R.3    Summers, P.E.4    Keevil, S.F.5
  • 7
    • 0026117505 scopus 로고
    • Motion artifact correction in MRI using generalized projections
    • Hedley M, Yan H, Rosenfeld D. Motion artifact correction in MRI using generalized projections. IEEE Trans Med Imaging 1991;10:40-46.
    • (1991) IEEE Trans Med Imaging , vol.10 , pp. 40-46
    • Hedley, M.1    Yan, H.2    Rosenfeld, D.3
  • 8
    • 0030395756 scopus 로고    scopus 로고
    • MRI artifact cancellation due to rigid motion in the imaging plane
    • Zoroofi RA, Sato Y, Tamura S, Naito H. MRI artifact cancellation due to rigid motion in the imaging plane. IEEE Trans Med Imaging 1996;15:768-784.
    • (1996) IEEE Trans Med Imaging , vol.15 , pp. 768-784
    • Zoroofi, R.A.1    Sato, Y.2    Tamura, S.3    Naito, H.4
  • 9
    • 0030786920 scopus 로고    scopus 로고
    • Diffusion-weighted multiple shot echo planar imaging of humans without navigation
    • Robson MD, Anderson AW, Gore JC. Diffusion-weighted multiple shot echo planar imaging of humans without navigation. Magn Reson Med 1997;38:82-88.
    • (1997) Magn Reson Med , vol.38 , pp. 82-88
    • Robson, M.D.1    Anderson, A.W.2    Gore, J.C.3
  • 10
    • 0028944350 scopus 로고
    • Spatial-frequency-tuned markers and adaptive correction for rotational motion
    • Korin HW, Felmlee JP, Riederer SJ, Ehman RL. Spatial-frequency-tuned markers and adaptive correction for rotational motion. Magn Reson Med 1995;33:663-669.
    • (1995) Magn Reson Med , vol.33 , pp. 663-669
    • Korin, H.W.1    Felmlee, J.P.2    Riederer, S.J.3    Ehman, R.L.4
  • 12
    • 0029184205 scopus 로고
    • Planar-motion correction using k-space data acquired by Fourier MR imaging
    • Wood ML, Shivji MJ, Stanchev PL. Planar-motion correction using k-space data acquired by Fourier MR imaging. J Magn Reson Imaging 1995;5:57-64.
    • (1995) J Magn Reson Imaging , vol.5 , pp. 57-64
    • Wood, M.L.1    Shivji, M.J.2    Stanchev, P.L.3
  • 13
    • 0028326327 scopus 로고
    • Echo-planar imaging of the brain at 3.0 T: First normal volunteer results
    • Mansfield P, Coxon R, Glover P. Echo-planar imaging of the brain at 3.0 T: first normal volunteer results. J Comput Assist Tomogr 1994;18:339-343.
    • (1994) J Comput Assist Tomogr , vol.18 , pp. 339-343
    • Mansfield, P.1    Coxon, R.2    Glover, P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.