메뉴 건너뛰기




Volumn 2016, Issue 3, 2016, Pages

Sub-milliSievert ultralow-dose CT colonography with iterative model reconstruction technique

Author keywords

CT colonography; Iterative reconstruction technique; Low dose; Polyp

Indexed keywords

BARIUM; SCOPOLAMINE BUTYL BROMIDE; UNCLASSIFIED DRUG;

EID: 84963984181     PISSN: None     EISSN: 21678359     Source Type: Journal    
DOI: 10.7717/peerj.1883     Document Type: Article
Times cited : (10)

References (32)
  • 1
    • 84883360966 scopus 로고    scopus 로고
    • Radiation risk from CT: implications for cancer screening
    • Albert JM. 2013. Radiation risk from CT: implications for cancer screening. American Journal of Roentgenology 201:W81-W87 DOI 10.2214/AJR.12.9226.
    • (2013) American Journal of Roentgenology , vol.201 , pp. W81-W87
    • Albert, J.M.1
  • 2
    • 84886799648 scopus 로고    scopus 로고
    • Extracolonic findings (ECF) on CT colonography (CTC) in patients presenting with colorectal symptoms
    • Badiani S, Tomas-Hernandez S, Karandikar S, Roy-Choudhury S. 2013. Extracolonic findings (ECF) on CT colonography (CTC) in patients presenting with colorectal symptoms. Acta Radiologica 54:851-862 DOI 10.1177/0284185113486371.
    • (2013) Acta Radiologica , vol.54 , pp. 851-862
    • Badiani, S.1    Tomas-Hernandez, S.2    Karandikar, S.3    Roy-Choudhury, S.4
  • 3
    • 22344437374 scopus 로고    scopus 로고
    • Mass screening with CT colonography: should the radiation exposure be of concern?
    • Brenner DJ, Georgsson MA. 2005. Mass screening with CT colonography: should the radiation exposure be of concern? Gastroenterology 129:328-337 DOI 10.1053/j.gastro.2005.05.021.
    • (2005) Gastroenterology , vol.129 , pp. 328-337
    • Brenner, D.J.1    Georgsson, M.A.2
  • 4
    • 84879497950 scopus 로고    scopus 로고
    • Dose reduction methods for CT colonography
    • Chang KJ, Yee J. 2013. Dose reduction methods for CT colonography. Abdominal Imaging 38:224-232 DOI 10.1007/s00261-012-9968-1.
    • (2013) Abdominal Imaging , vol.38 , pp. 224-232
    • Chang, K.J.1    Yee, J.2
  • 5
    • 80053632865 scopus 로고    scopus 로고
    • Comparison of accuracy and time-efficiency of CT colonography between conventional and panoramic 3D interpretation methods: an anthropomorphic phantom study
    • Choi J-I, Kim SH, Kim SH, Park H-S, Lee JM, Lee JY, Han JK, Choi BI. 2011. Comparison of accuracy and time-efficiency of CT colonography between conventional and panoramic 3D interpretation methods: an anthropomorphic phantom study. European Journal of Radiology 80:e68-e75 DOI 10.1016/j.ejrad.2010.08.022.
    • (2011) European Journal of Radiology , vol.80 , pp. e68-e75
    • Choi, J.-I.1    Kim, S.H.2    Kim, S.H.3    Park, H.-S.4    Lee, J.M.5    Lee, J.Y.6    Han, J.K.7    Choi, B.I.8
  • 7
    • 77950604342 scopus 로고    scopus 로고
    • Estimating effective dose for CT using dose-length product compared with using organ doses: consequences of adopting international commission on radiological protection publication 103 or dual-energy scanning
    • Christner JA, Kofler JM, McCollough CH. 2010. Estimating effective dose for CT using dose-length product compared with using organ doses: consequences of adopting international commission on radiological protection publication 103 or dual-energy scanning. American Journal of Roentgenology 194:881-889 DOI 10.2214/AJR.09.3462.
    • (2010) American Journal of Roentgenology , vol.194 , pp. 881-889
    • Christner, J.A.1    Kofler, J.M.2    McCollough, C.H.3
  • 8
    • 16544364276 scopus 로고    scopus 로고
    • Feasibility of MDCT Colonography in ultra-low-dose technique in the detection of colorectal lesions: comparison with high-resolution video colonoscopy
    • Cohnen M, Vogt C, Beck A, Andersen K, Heinen W, Vom Dahl S, Aurich V, Haeussinger D, Moedder U. 2004. Feasibility of MDCT Colonography in ultra-low-dose technique in the detection of colorectal lesions: comparison with high-resolution video colonoscopy. American Journal of Roentgenology 183:1355-1359 DOI 10.2214/ajr.183.5.1831355.
    • (2004) American Journal of Roentgenology , vol.183 , pp. 1355-1359
    • Cohnen, M.1    Vogt, C.2    Beck, A.3    Andersen, K.4    Heinen, W.5    Vom Dahl, S.6    Aurich, V.7    Haeussinger, D.8    Moedder, U.9
  • 10
    • 77952310162 scopus 로고    scopus 로고
    • Evaluation of image quality and lesion perception by human readers on 3D CT colonography: comparison of standard and low radiation dose
    • Fisichella VA, Båth M, Johnsson ÅA, Jäderling F, Bergsten T, Persson U, Mellingen K, Hellström M. 2010. Evaluation of image quality and lesion perception by human readers on 3D CT colonography: comparison of standard and low radiation dose. European Radiology 20:630-639 DOI 10.1007/s00330-009-1601-5.
    • (2010) European Radiology , vol.20 , pp. 630-639
    • Fisichella, V.A.1    Båth, M.2    Johnsson, Å.A.3    Jäderling, F.4    Bergsten, T.5    Persson, U.6    Mellingen, K.7    Hellström, M.8
  • 11
    • 77954708865 scopus 로고    scopus 로고
    • Reducing the radiation dose for CT colonography using adaptive statistical iterative reconstruction: a pilot study
    • Flicek KT, Hara AK, Silva AC, Wu Q, Peter MB, Johnson CD. 2010. Reducing the radiation dose for CT colonography using adaptive statistical iterative reconstruction: a pilot study. American Journal of Roentgenology 195:126-131 DOI 10.2214/AJR.09.3855.
    • (2010) American Journal of Roentgenology , vol.195 , pp. 126-131
    • Flicek, K.T.1    Hara, A.K.2    Silva, A.C.3    Wu, Q.4    Peter, M.B.5    Johnson, C.D.6
  • 13
    • 0345015529 scopus 로고    scopus 로고
    • Detection of colorectal lesions: lower-dose multi-detector row helical CT colonography compared with conventional colonoscopy 1
    • Iannaccone R, Laghi A, Catalano C, Brink JA, Mangiapane F, Trenna S, Piacentini F, Passariello R. 2003. Detection of colorectal lesions: lower-dose multi-detector row helical CT colonography compared with conventional colonoscopy 1. Radiology 229:775-781 DOI 10.1148/radiol.2293021399.
    • (2003) Radiology , vol.229 , pp. 775-781
    • Iannaccone, R.1    Laghi, A.2    Catalano, C.3    Brink, J.A.4    Mangiapane, F.5    Trenna, S.6    Piacentini, F.7    Passariello, R.8
  • 14
    • 84930893731 scopus 로고    scopus 로고
    • Submilisievert ultralow-dose CT colonography using iterative reconstruction technique: a feasibility study
    • Lambert L, Danes J, Jahoda J, Masek M, Lisy J, Ourednicek P. 2015a. Submilisievert ultralow-dose CT colonography using iterative reconstruction technique: a feasibility study. ACTA Radiologica 56:517-525 DOI 10.1177/0284185114533683.
    • (2015) ACTA Radiologica , vol.56 , pp. 517-525
    • Lambert, L.1    Danes, J.2    Jahoda, J.3    Masek, M.4    Lisy, J.5    Ourednicek, P.6
  • 15
    • 84930371604 scopus 로고    scopus 로고
    • Model-based vs hybrid iterative reconstruction technique in ultralow-dose submillisievert CT colonography
    • Lambert L, Ourednicek P, Jahoda J, Lambertova A, Danes J. 2015b. Model-based vs hybrid iterative reconstruction technique in ultralow-dose submillisievert CT colonography. British Journal of Radiology 88: 20140667 DOI 10.1259/bjr.20140667.
    • (2015) British Journal of Radiology , vol.88
    • Lambert, L.1    Ourednicek, P.2    Jahoda, J.3    Lambertova, A.4    Danes, J.5
  • 16
    • 84879501599 scopus 로고    scopus 로고
    • CT colonography: avoiding traps and pitfalls
    • Lefere P, Gryspeerdt S. 2011. CT colonography: avoiding traps and pitfalls. Insights Imaging 2:57-68 DOI 10.1007/s13244-010-0054-3.
    • (2011) Insights Imaging , vol.2 , pp. 57-68
    • Lefere, P.1    Gryspeerdt, S.2
  • 18
    • 84930477523 scopus 로고    scopus 로고
    • Sub-milliSievert (sub-mSv) CT colonography: a prospective comparison of image quality and polyp conspicuity at reduced-dose versus standarddose imaging
    • Lubner MG, Pooler BD, Kitchin DR, Tang J, Li K, Kim DH, Del Rio AM, Chen G-H, Pickhardt PJ. 2015. Sub-milliSievert (sub-mSv) CT colonography: a prospective comparison of image quality and polyp conspicuity at reduced-dose versus standarddose imaging. European Radiology 25:2089-2102 DOI 10.1007/s00330-015-3603-9.
    • (2015) European Radiology , vol.25 , pp. 2089-2102
    • Lubner, M.G.1    Pooler, B.D.2    Kitchin, D.R.3    Tang, J.4    Li, K.5    Kim, D.H.6    Del Rio, A.M.7    Chen, G.-H.8    Pickhardt, P.J.9
  • 20
    • 84897423630 scopus 로고    scopus 로고
    • Iterative model reconstruction: simultaneously lowered computed tomography radiation dose and improved image quality
    • Mehta D, Thompson R, Morton T, Dhanantwari A, Shefer E. 2013. Iterative model reconstruction: simultaneously lowered computed tomography radiation dose and improved image quality. Medical Physics International Journal 2:147-155.
    • (2013) Medical Physics International Journal , vol.2 , pp. 147-155
    • Mehta, D.1    Thompson, R.2    Morton, T.3    Dhanantwari, A.4    Shefer, E.5
  • 21
    • 84912559682 scopus 로고    scopus 로고
    • Evaluation of dose reduction and image quality in CT colonography: comparison of low-dose CT with iterative reconstruction and routine-dose CT with filtered back projection
    • Nagata K, Fujiwara M, Kanazawa H, Mogi T, Iida N, Mitsushima T, Lefor AT, Sugimoto H. 2015. Evaluation of dose reduction and image quality in CT colonography: comparison of low-dose CT with iterative reconstruction and routine-dose CT with filtered back projection. European Radiology 25:221-229 DOI 10.1007/s00330-014-3350-3.
    • (2015) European Radiology , vol.25 , pp. 221-229
    • Nagata, K.1    Fujiwara, M.2    Kanazawa, H.3    Mogi, T.4    Iida, N.5    Mitsushima, T.6    Lefor, A.T.7    Sugimoto, H.8
  • 22
    • 33847355213 scopus 로고    scopus 로고
    • Fully automated three-dimensional detection of polyps in fecal-tagging CT colonography
    • Näppi J, Yoshida H. 2007. Fully automated three-dimensional detection of polyps in fecal-tagging CT colonography. Academic Radiology 14:287-300 DOI 10.1016/j.acra.2006.11.007.
    • (2007) Academic Radiology , vol.14 , pp. 287-300
    • Näppi, J.1    Yoshida, H.2
  • 23
    • 84930154384 scopus 로고    scopus 로고
    • CT colonography for population screening: ready for prime time?
    • Pickhardt PJ. 2015. CT colonography for population screening: ready for prime time? Digestive Diseases and Sciences 60:647-659 DOI 10.1007/s10620-014-3454-2.
    • (2015) Digestive Diseases and Sciences , vol.60 , pp. 647-659
    • Pickhardt, P.J.1
  • 25
    • 37549067786 scopus 로고    scopus 로고
    • Small and diminutive polyps detected at screening CT colonography: a decision analysis for referral to colonoscopy
    • Pickhardt PJ, Hassan C, Laghi A, Zullo A, Kim DH, Iafrate F, Morini S. 2008a. Small and diminutive polyps detected at screening CT colonography: a decision analysis for referral to colonoscopy. American Journal of Roentgenology 190:136-144 DOI 10.2214/AJR.07.2646.
    • (2008) American Journal of Roentgenology , vol.190 , pp. 136-144
    • Pickhardt, P.J.1    Hassan, C.2    Laghi, A.3    Zullo, A.4    Kim, D.H.5    Iafrate, F.6    Morini, S.7
  • 28
    • 84870903463 scopus 로고    scopus 로고
    • Abdominal CT with model-based iterative reconstruction (MBIR): initial results of a prospective trial comparing ultralow-dose with standard-dose imaging
    • Pickhardt PJ, Lubner MG, Kim DH, Tang J, Ruma JA, Del Rio AM, Chen G-H. 2012. Abdominal CT with model-based iterative reconstruction (MBIR): initial results of a prospective trial comparing ultralow-dose with standard-dose imaging. American Journal of Roentgenology 199:1266-1274 DOI 10.2214/AJR.12.9382.
    • (2012) American Journal of Roentgenology , vol.199 , pp. 1266-1274
    • Pickhardt, P.J.1    Lubner, M.G.2    Kim, D.H.3    Tang, J.4    Ruma, J.A.5    Del Rio, A.M.6    Chen, G.-H.7
  • 29
    • 77952704813 scopus 로고    scopus 로고
    • Polyp size measurement at CT colonography: what do we know and what do we need to know?
    • Summers RM. 2010. Polyp size measurement at CT colonography: what do we know and what do we need to know? Radiology 255:707-720 DOI 10.1148/radiol.10090877.
    • (2010) Radiology , vol.255 , pp. 707-720
    • Summers, R.M.1
  • 30
    • 33744994744 scopus 로고    scopus 로고
    • CT colonography: effect of colonic distension on polyp measurement accuracy and agreement-in vitro study
    • Taylor S, Slater A, Honeyfield L, Burling D, Halligan S. 2006. CT colonography: effect of colonic distension on polyp measurement accuracy and agreement-in vitro study. Academic Radiology 13:850-859 DOI 10.1016/j.acra.2006.03.018.
    • (2006) Academic Radiology , vol.13 , pp. 850-859
    • Taylor, S.1    Slater, A.2    Honeyfield, L.3    Burling, D.4    Halligan, S.5
  • 31
    • 84882995493 scopus 로고    scopus 로고
    • Advances in CT colonography for colorectal cancer screening and diagnosis
    • Yee J. 2013. Advances in CT colonography for colorectal cancer screening and diagnosis. Journal of Cancer 4:200-209 DOI 10.7150/jca.5858.
    • (2013) Journal of Cancer , vol.4 , pp. 200-209
    • Yee, J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.