메뉴 건너뛰기




Volumn 25, Issue 1, 2015, Pages 221-229

Evaluation of dose reduction and image quality in CT colonography: Comparison of low-dose CT with iterative reconstruction and routine-dose CT with filtered back projection

Author keywords

Colonography; Computed tomography; Image enhancement; Iterative reconstruction techniques; Radiation dosage

Indexed keywords

ADULT; ARTICLE; BODY MASS; BODY POSTURE; COLORECTAL CANCER; COMPUTED TOMOGRAPHIC COLONOGRAPHY; COMPUTED TOMOGRAPHY SCANNER; CONE BEAM COMPUTED TOMOGRAPHY; CONTROLLED STUDY; FEMALE; HUMAN; IMAGE QUALITY; MAJOR CLINICAL STUDY; MALE; NOISE MEASUREMENT; PROSPECTIVE STUDY; QUALITY CONTROL; RADIATION DOSE REDUCTION; RADIATION EXPOSURE; RADIATION RESPONSE; SCREENING; CLINICAL PROTOCOL; COLON DISEASE; COMPUTER ASSISTED DIAGNOSIS; EVALUATION STUDY; MIDDLE AGED; MULTIDETECTOR COMPUTED TOMOGRAPHY; PROCEDURES; RADIATION DOSE;

EID: 84912559682     PISSN: 09387994     EISSN: 14321084     Source Type: Journal    
DOI: 10.1007/s00330-014-3350-3     Document Type: Article
Times cited : (23)

References (27)
  • 1
    • 36549007486 scopus 로고    scopus 로고
    • Computed tomography—an increasing source of radiation exposure
    • COI: 1:CAS:528:DC%2BD2sXhsVSlurfF, PID: 18046031
    • Brenner DJ, Hall EJ (2007) Computed tomography—an increasing source of radiation exposure. N Engl J Med 357:2277–2284
    • (2007) N Engl J Med , vol.357 , pp. 2277-2284
    • Brenner, D.J.1    Hall, E.J.2
  • 2
    • 84888362887 scopus 로고    scopus 로고
    • CT radiation dose: current controversies and dose reduction strategies
    • PID: 24261368
    • Costello JE, Cecava ND, Tucker JE, Bau JL (2013) CT radiation dose: current controversies and dose reduction strategies. AJR Am J Roentgenol 201:1283–1290
    • (2013) AJR Am J Roentgenol , vol.201 , pp. 1283-1290
    • Costello, J.E.1    Cecava, N.D.2    Tucker, J.E.3    Bau, J.L.4
  • 3
    • 84881504621 scopus 로고    scopus 로고
    • The relationship between media consumption and health-related anxieties after the Fukushima Daiichi Nuclear Disaster
    • COI: 1:CAS:528:DC%2BC3sXhtlamsbjJ, PID: 23967046
    • Sugimoto A, Nomura S, Tsubokura M et al (2013) The relationship between media consumption and health-related anxieties after the Fukushima Daiichi Nuclear Disaster. PLoS One 8:e65331
    • (2013) PLoS One , vol.8 , pp. e65331
    • Sugimoto, A.1    Nomura, S.2    Tsubokura, M.3
  • 4
    • 84891644898 scopus 로고    scopus 로고
    • Perspective on the nuclear power plant accident caused by the great east Japan earthquake and tsunami: health impairment risks due to pollution by radioactive materials from the damaged plant as recognized by experts and by the general population and role of the experts
    • PID: 23095364
    • Sugita M, Miyakawa M (2012) Perspective on the nuclear power plant accident caused by the great east Japan earthquake and tsunami: health impairment risks due to pollution by radioactive materials from the damaged plant as recognized by experts and by the general population and role of the experts. Nihon Eiseigaku Zasshi 67:514–523
    • (2012) Nihon Eiseigaku Zasshi , vol.67 , pp. 514-523
    • Sugita, M.1    Miyakawa, M.2
  • 6
    • 0031132763 scopus 로고    scopus 로고
    • Reducing data size and radiation dose for CT colonography
    • COI: 1:STN:280:DyaK2s3nsFKgug%3D%3D, PID: 9129408
    • Hara AK, Johnson CD, Reed JE et al (1997) Reducing data size and radiation dose for CT colonography. AJR 168:1181–1184
    • (1997) AJR , vol.168 , pp. 1181-1184
    • Hara, A.K.1    Johnson, C.D.2    Reed, J.E.3
  • 7
    • 33748461416 scopus 로고    scopus 로고
    • Dose reduction and image quality in MDCT colonography using tube current modulation
    • COI: 1:STN:280:DC%2BD28rgtlKlsw%3D%3D, PID: 16928932
    • Graser A, Wintersperger BJ, Suess C, Reiser MF, Becker CR (2006) Dose reduction and image quality in MDCT colonography using tube current modulation. AJR 187:695–701
    • (2006) AJR , vol.187 , pp. 695-701
    • Graser, A.1    Wintersperger, B.J.2    Suess, C.3    Reiser, M.F.4    Becker, C.R.5
  • 8
    • 79951950909 scopus 로고    scopus 로고
    • Does the amount of tagged stool and fluid significantly affect the radiation exposure in low-dose CT colonography performed with an automatic exposure control?
    • PID: 20700594
    • Lim HK, Lee KH, Kim SY et al (2011) Does the amount of tagged stool and fluid significantly affect the radiation exposure in low-dose CT colonography performed with an automatic exposure control? Eur Radiol 21:345–352
    • (2011) Eur Radiol , vol.21 , pp. 345-352
    • Lim, H.K.1    Lee, K.H.2    Kim, S.Y.3
  • 9
    • 77952310162 scopus 로고    scopus 로고
    • Evaluation of image quality and lesion perception by human readers on 3D CT colonography: comparison of standard and low radiation dose
    • PID: 19760236
    • Fisichella VA, Båth M, Allansdotter Johnsson A et al (2010) Evaluation of image quality and lesion perception by human readers on 3D CT colonography: comparison of standard and low radiation dose. Eur Radiol 20:630–639
    • (2010) Eur Radiol , vol.20 , pp. 630-639
    • Fisichella, V.A.1    Båth, M.2    Allansdotter Johnsson, A.3
  • 10
    • 84879497950 scopus 로고    scopus 로고
    • Dose reduction methods for CT colonography
    • PID: 23229777
    • Chang KJ, Yee J (2013) Dose reduction methods for CT colonography. Abdom Imaging 38:224–232
    • (2013) Abdom Imaging , vol.38 , pp. 224-232
    • Chang, K.J.1    Yee, J.2
  • 11
    • 84883440586 scopus 로고    scopus 로고
    • The time has arrived for national reimbursement of screening CT colonography
    • PID: 23789660
    • Yee J, Keysor KJ, Kim DH (2013) The time has arrived for national reimbursement of screening CT colonography. AJR Am J Roentgenol 201:73–79
    • (2013) AJR Am J Roentgenol , vol.201 , pp. 73-79
    • Yee, J.1    Keysor, K.J.2    Kim, D.H.3
  • 12
    • 84864715912 scopus 로고    scopus 로고
    • Does CT colonography have a role for population-based colorectal cancer screening?
    • PID: 22549102
    • de Haan MC, Halligan S, Stoker J (2012) Does CT colonography have a role for population-based colorectal cancer screening? Eur Radiol 22:1495–1503
    • (2012) Eur Radiol , vol.22 , pp. 1495-1503
    • de Haan, M.C.1    Halligan, S.2    Stoker, J.3
  • 13
    • 84896740875 scopus 로고    scopus 로고
    • Radiation risks in lung cancer screening programs: a comparison with nuclear industry workers and atomic bomb survivors
    • PID: 24590022
    • McCunney RJ, Li J (2014) Radiation risks in lung cancer screening programs: a comparison with nuclear industry workers and atomic bomb survivors. Chest 145:618–624
    • (2014) Chest , vol.145 , pp. 618-624
    • McCunney, R.J.1    Li, J.2
  • 14
    • 84865589993 scopus 로고    scopus 로고
    • Emphysema quantification by low-dose CT: potential impact of adaptive iterative dose reduction using 3D processing
    • PID: 22915399
    • Nishio M, Matsumoto S, Ohno Y et al (2012) Emphysema quantification by low-dose CT: potential impact of adaptive iterative dose reduction using 3D processing. AJR 199:595–601
    • (2012) AJR , vol.199 , pp. 595-601
    • Nishio, M.1    Matsumoto, S.2    Ohno, Y.3
  • 15
    • 84866864966 scopus 로고    scopus 로고
    • Adaptive iterative dose reduction using 3D processing for reduced- and low-dose pulmonary CT: comparison with standard-dose CT for image noise reduction and radiological findings
    • PID: 22997397
    • Ohno Y, Takenaka D, Kanda T et al (2012) Adaptive iterative dose reduction using 3D processing for reduced- and low-dose pulmonary CT: comparison with standard-dose CT for image noise reduction and radiological findings. AJR 199:W477–485
    • (2012) AJR , vol.199 , pp. W477-W485
    • Ohno, Y.1    Takenaka, D.2    Kanda, T.3
  • 16
    • 84878826478 scopus 로고    scopus 로고
    • Low-dose computed tomographic urography using adaptive iterative dose reduction 3-dimensional: comparison with routine-dose computed tomography with filtered back projection
    • PID: 23674016
    • Juri H, Matsuki M, Inada Y et al (2013) Low-dose computed tomographic urography using adaptive iterative dose reduction 3-dimensional: comparison with routine-dose computed tomography with filtered back projection. J Comput Assist Tomogr 37:426–431
    • (2013) J Comput Assist Tomogr , vol.37 , pp. 426-431
    • Juri, H.1    Matsuki, M.2    Inada, Y.3
  • 17
    • 84886800740 scopus 로고    scopus 로고
    • Impact of adaptive iterative dose reduction (AIDR) 3D on low-dose abdominal CT: comparison with routine-dose CT using filtered back projection
    • PID: 23761554
    • Matsuki M, Murakami T, Juri H, Yoshikawa S, Narumi Y (2013) Impact of adaptive iterative dose reduction (AIDR) 3D on low-dose abdominal CT: comparison with routine-dose CT using filtered back projection. Acta Radiol 54:869–875
    • (2013) Acta Radiol , vol.54 , pp. 869-875
    • Matsuki, M.1    Murakami, T.2    Juri, H.3    Yoshikawa, S.4    Narumi, Y.5
  • 18
    • 84869870556 scopus 로고    scopus 로고
    • Dose reduction in chest CT: comparison of the adaptive iterative dose reduction 3D, adaptive iterative dose reduction, and filtered back projection reconstruction techniques
    • PID: 22883532
    • Yamada Y, Jinzaki M, Hosokawa T et al (2012) Dose reduction in chest CT: comparison of the adaptive iterative dose reduction 3D, adaptive iterative dose reduction, and filtered back projection reconstruction techniques. Eur J Radiol 81:4185–4195
    • (2012) Eur J Radiol , vol.81 , pp. 4185-4195
    • Yamada, Y.1    Jinzaki, M.2    Hosokawa, T.3
  • 19
    • 77954708865 scopus 로고    scopus 로고
    • Reducing the radiation dose for CT colonography using adaptive statistical iterative reconstruction: A pilot study
    • PID: 20566805
    • Flicek KT, Hara AK, Silva AC, Wu Q, Peter MB, Johnson CD (2010) Reducing the radiation dose for CT colonography using adaptive statistical iterative reconstruction: A pilot study. AJR 195:126–131
    • (2010) AJR , vol.195 , pp. 126-131
    • Flicek, K.T.1    Hara, A.K.2    Silva, A.C.3    Wu, Q.4    Peter, M.B.5    Johnson, C.D.6
  • 20
    • 84866711802 scopus 로고    scopus 로고
    • Adaptive statistical iterative reconstruction and Veo: assessment of image quality and diagnostic performance in CT colonography at various radiation doses
    • PID: 22992612
    • Yoon MA, Kim SH, Lee JM et al (2012) Adaptive statistical iterative reconstruction and Veo: assessment of image quality and diagnostic performance in CT colonography at various radiation doses. J Comput Assist Tomogr 36:596–601
    • (2012) J Comput Assist Tomogr , vol.36 , pp. 596-601
    • Yoon, M.A.1    Kim, S.H.2    Lee, J.M.3
  • 21
    • 33750982428 scopus 로고    scopus 로고
    • Polyethylene glycol solution (PEG) plus contrast medium vs PEG alone preparation for CT colonography and conventional colonoscopy in preoperative colorectal cancer staging
    • PID: 16583194
    • Nagata K, Endo S, Ichikawa T et al (2007) Polyethylene glycol solution (PEG) plus contrast medium vs PEG alone preparation for CT colonography and conventional colonoscopy in preoperative colorectal cancer staging. Int J Colorectal Dis 22:69–76
    • (2007) Int J Colorectal Dis , vol.22 , pp. 69-76
    • Nagata, K.1    Endo, S.2    Ichikawa, T.3
  • 22
    • 66649133424 scopus 로고    scopus 로고
    • Full-laxative versus minimum-laxative fecal-tagging CT colonography using 64-detector row CT: prospective blinded comparison of diagnostic performance, tagging quality, and patient acceptance
    • PID: 19375954
    • Nagata K, Okawa T, Honma A, Endo S, Kudo SE, Yoshida H (2009) Full-laxative versus minimum-laxative fecal-tagging CT colonography using 64-detector row CT: prospective blinded comparison of diagnostic performance, tagging quality, and patient acceptance. Acad Radiol 16:780–789
    • (2009) Acad Radiol , vol.16 , pp. 780-789
    • Nagata, K.1    Okawa, T.2    Honma, A.3    Endo, S.4    Kudo, S.E.5    Yoshida, H.6
  • 23
    • 33846529471 scopus 로고    scopus 로고
    • National survey of doses from CT in the UK: 2003
    • COI: 1:STN:280:DC%2BD2s%2Fhs1OksA%3D%3D, PID: 17213302
    • Shrimpton PC, Hillier MC, Lewis MA, Dunn M (2006) National survey of doses from CT in the UK: 2003. Br J Radiol 79:968–980
    • (2006) Br J Radiol , vol.79 , pp. 968-980
    • Shrimpton, P.C.1    Hillier, M.C.2    Lewis, M.A.3    Dunn, M.4
  • 24
    • 79959559491 scopus 로고    scopus 로고
    • Reduced image noise at low-dose multidetector CT of the abdomen with prior image constrained compressed sensing algorithm
    • PID: 21436086
    • Lubner MG, Pickhardt PJ, Tang J, Chen GH (2011) Reduced image noise at low-dose multidetector CT of the abdomen with prior image constrained compressed sensing algorithm. Radiology 260:248–256
    • (2011) Radiology , vol.260 , pp. 248-256
    • Lubner, M.G.1    Pickhardt, P.J.2    Tang, J.3    Chen, G.H.4
  • 25
    • 4644221703 scopus 로고    scopus 로고
    • Sixteen-detector row CT of abdomen and pelvis: study for optimization of Z-axis modulation technique performed in 153 patients
    • PID: 15454622
    • Kalra MK, Maher MM, Kamath RS et al (2004) Sixteen-detector row CT of abdomen and pelvis: study for optimization of Z-axis modulation technique performed in 153 patients. Radiology 233:241–249
    • (2004) Radiology , vol.233 , pp. 241-249
    • Kalra, M.K.1    Maher, M.M.2    Kamath, R.S.3
  • 27
    • 84864820603 scopus 로고    scopus 로고
    • Effective radiation dose in CT colonography: is there a downward trend?
    • PID: 22750132
    • Boellaard TN, Venema HW, Streekstra GJ, Stoker J (2012) Effective radiation dose in CT colonography: is there a downward trend? Acad Radiol 19:1127–1133
    • (2012) Acad Radiol , vol.19 , pp. 1127-1133
    • Boellaard, T.N.1    Venema, H.W.2    Streekstra, G.J.3    Stoker, J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.