메뉴 건너뛰기




Volumn 194, Issue 4, 2010, Pages 881-889

Estimating effective dose for ct using dose-length product compared with using organ doses: Consequences of adopting international commission on radiological protection publication 103 or dual-energy scanning

Author keywords

CT; DLP; Dose length product; Dual energy CT; Effective dose; Effective dose equivalent; ICRP publication 103; ICRP publication 26; ICRP publication 60; Organ dose; Tissue weighting factors

Indexed keywords

ABDOMEN; ANGIOCARDIOGRAPHY; ARTICLE; CLINICAL PROTOCOL; COMPUTED TOMOGRAPHIC ANGIOGRAPHY; COMPUTED TOMOGRAPHY SCANNER; COMPUTER ASSISTED TOMOGRAPHY; CONTROLLED STUDY; CORONARY ARTERY; DOSIMETRY; HEAD; LIVER; MONTE CARLO METHOD; PELVIS; PRIORITY JOURNAL; RADIATION DOSE; RADIATION PROTECTION; THORAX;

EID: 77950604342     PISSN: 0361803X     EISSN: None     Source Type: Journal    
DOI: 10.2214/AJR.09.3462     Document Type: Article
Times cited : (404)

References (33)
  • 1
    • 0016696020 scopus 로고
    • The concept of effective dose: A proposal for the combination of organ doses
    • Jacobi W. The concept of effective dose: a proposal for the combination of organ doses. Radiat Environ Biophys 1975; 12:101-109
    • (1975) Radiat Environ Biophys , vol.12 , pp. 101-109
    • Jacobi, W.1
  • 2
    • 0003733263 scopus 로고    scopus 로고
    • International commission on radiological protection
    • Oxford, UK: Pergamon Press, ICRP publication
    • International Commission on Radiological Protection. Recommendations of the International Commission on Radiological Protection. Oxford, UK: Pergamon Press, 1977:ICRP publication no. 26
    • (1977) Recommendations of the International Commission on Radiological Protection , Issue.26
  • 3
    • 0034118614 scopus 로고    scopus 로고
    • Calculation of effective dose
    • McCollough CH, Schueler BA. Calculation of effective dose. Med Phys 2000; 27:828-837
    • (2000) Med Phys , vol.27 , pp. 828-837
    • McCollough, C.H.1    Schueler, B.A.2
  • 4
    • 34948887091 scopus 로고    scopus 로고
    • Effective dose how should it be applied to medical exposures?
    • Martin CJ. Effective dose: how should it be applied to medical exposures? Br J Radiol 2007; 80:639-647
    • (2007) Br J Radiol , vol.80 , pp. 639-647
    • Martin, C.J.1
  • 15
  • 16
    • 0019485556 scopus 로고
    • A method for describing the doses delivered by transmission x-ray computed tomography
    • Shope TB, Gagne RM, Johnson GC. A method for describing the doses delivered by transmission x-ray computed tomography. Med Phys 1981; 8:488-495
    • (1981) Med Phys , vol.8 , pp. 488-495
    • Shope, T.B.1    Gagne, R.M.2    Johnson, G.C.3
  • 17
    • 0036831529 scopus 로고    scopus 로고
    • AAPM/RSNA physics tutorial for residents: Topics in CT-radiation dose in CT
    • McNitt-Gray MF. AAPM/RSNA physics tutorial for residents: topics in CT-radiation dose in CT. RadioGraphics 2002; 22:1541-1553
    • (2002) RadioGraphics , vol.22 , pp. 1541-1553
    • McNitt-Gray, M.F.1
  • 18
    • 56149093386 scopus 로고    scopus 로고
    • CT dose: How to measure, how to reduce
    • McCollough C. CT dose: how to measure, how to reduce. Health Phys 2008; 95:508-517
    • (2008) Health Phys , vol.95 , pp. 508-517
    • McCollough, C.1
  • 22
    • 0014559581 scopus 로고
    • Estimates of absorbed fractions for monoenergetic photon sources uniformly distributed in various organs of a heterogeneous phantom
    • Snyder WS, Fisher HL Jr, Ford MR, Warner GG. Estimates of absorbed fractions for monoenergetic photon sources uniformly distributed in various organs of a heterogeneous phantom. J Nucl Med 1969; [suppl 3]:7-52
    • (1969) J Nucl Med , vol.SUPPL 3 , pp. 7-52
    • Snyder, W.S.1    Fisher Jr., H.L.2    Ford, M.R.3    Warner, G.G.4
  • 23
    • 77950622215 scopus 로고    scopus 로고
    • Accessed January
    • ImPACT Group Website. www.impactscan.org. Accessed January 20, 2010
    • ImPACT Group Website , vol.20 , pp. 2010
  • 24
    • 0042279293 scopus 로고    scopus 로고
    • Estimating patient dose on current CT scanners: Results of the ImPACT CT dose survey
    • Lewis M, Edyvean S, Sassi S, Kiremidjian H, Keat N, Britten A. Estimating patient dose on current CT scanners: results of the ImPACT CT dose survey. RAD Magazine 2000; 26:17-18
    • (2000) RAD Magazine , vol.26 , pp. 17-18
    • Lewis, M.1    Edyvean, S.2    Sassi, S.3    Kiremidjian, H.4    Keat, N.5    Britten, A.6
  • 25
    • 0037325935 scopus 로고    scopus 로고
    • Patient dose in cardiac computed tomography
    • McCollough CH. Patient dose in cardiac computed tomography. Herz 2003; 28:1-6
    • (2003) Herz , vol.28 , pp. 1-6
    • McCollough, C.H.1
  • 26
    • 0025221610 scopus 로고
    • Computed tomography scanning with simultaneous patient translation
    • Crawford CR, King KF. Computed tomography scanning with simultaneous patient translation. Med Phys 1990; 17:967-982
    • (1990) Med Phys , vol.17 , pp. 967-982
    • Crawford, C.R.1    King, K.F.2
  • 27
    • 0036336399 scopus 로고    scopus 로고
    • Primary radiation outside the imaged volume of a multislice helical CT scan
    • Nicholson R, Fetherston S. Primary radiation outside the imaged volume of a multislice helical CT scan. Br J Radiol 2002; 75:518-522
    • (2002) Br J Radiol , vol.75 , pp. 518-522
    • Nicholson, R.1    Fetherston, S.2
  • 28
    • 0036580665 scopus 로고    scopus 로고
    • Multislice helical CT of the heart with retrospective ECG gating: Reduction of radiation exposure by ECG-controlled tube current modulation
    • Jakobs TF, Becker CR, Ohnesorge B, et al. Multislice helical CT of the heart with retrospective ECG gating: reduction of radiation exposure by ECG-controlled tube current modulation. Eur Radiol 2002; 12:1081-1086
    • (2002) Eur Radiol , vol.12 , pp. 1081-1086
    • Jakobs, T.F.1    Becker, C.R.2    Ohnesorge, B.3
  • 29
    • 33645562681 scopus 로고    scopus 로고
    • CT dose reduction and dose management tools: Overview of available options
    • McCollough CH, Bruesewitz MR, Kofler JM Jr. CT dose reduction and dose management tools: overview of available options. RadioGraphics 2006; 26:503-512
    • (2006) RadioGraphics , vol.26 , pp. 503-512
    • McCollough, C.H.1    Bruesewitz, M.R.2    Kofler, Jr.J.M.3
  • 30
    • 10344230948 scopus 로고    scopus 로고
    • Performance evaluation of a 64-slice CT system with z-flying focal spot
    • Flohr T, Stierstorfer K, Raupach R, Ulzheimer S, Bruder H. Performance evaluation of a 64-slice CT system with z-flying focal spot. Rofo 2004; 176:1803-1810
    • (2004) Rofo , vol.176 , pp. 1803-1810
    • Flohr, T.1    Stierstorfer, K.2    Raupach, R.3    Ulzheimer, S.4    Bruder, H.5
  • 31
    • 77950623629 scopus 로고    scopus 로고
    • International Electrotechnical Commission. Medical electrical equipment. Part 2-44., ed. 2.1 Geneva, Switzerland: International Electrotechnical Commission (IEC) Central Office, 2002:IEC publication no. 60601-2-44
    • International Electrotechnical Commission. Medical electrical equipment. Part 2-44. Particular requirements for the safety of x-ray equipment for computed tomography, ed. 2.1 Geneva, Switzerland: International Electrotechnical Commission (IEC) Central Office, 2002:IEC publication no. 60601-2-44
    • Particular Requirements for the Safety of X-ray Equipment for Computed Tomography
  • 32
    • 0028893476 scopus 로고
    • Computed tomography dose assessment: A practical approach
    • Leitz W, Axelsson B, Szendro G. Computed tomography dose assessment: a practical approach. Radiat Prot Dosimetry 1995; 57:377-380
    • (1995) Radiat Prot Dosimetry , vol.57 , pp. 377-380
    • Leitz, W.1    Axelsson, B.2    Szendro, G.3
  • 33
    • 61749083655 scopus 로고    scopus 로고
    • Effective dose and dose-length product in CT
    • Shrimpton PC, Wall BF. Effective dose and dose-length product in CT. Radiology 2009; 250:604-605
    • (2009) Radiology , vol.250 , pp. 604-605
    • Shrimpton, P.C.1    Wall, B.F.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.