메뉴 건너뛰기




Volumn 265, Issue 3, 2012, Pages 841-847

Size-specific dose estimates for adult patients at CT of the torso

Author keywords

[No Author keywords available]

Indexed keywords

ABDOMINAL RADIOGRAPHY; ADULT; AGED; ANTERIOR POSTERIOR AXIS; ARTICLE; BODY SIZE; COMPUTED TOMOGRAPHY SCANNER; COMPUTER ASSISTED TOMOGRAPHY; CORRELATIONAL STUDY; CT DOSE INDEX; DOSIMETRY; FEMALE; HUMAN; INFORMED CONSENT; INSTITUTIONAL REVIEW; LINEAR REGRESSION ANALYSIS; MAJOR CLINICAL STUDY; MALE; MEASUREMENT; OBSERVER VARIATION; PRIORITY JOURNAL; RADIATION ATTENUATION; RADIATION EXPOSURE; RADIOLOGICAL PARAMETERS; RETROSPECTIVE STUDY; SIZE SPECIFIC DOSE ESTIMATE; STATISTICAL MODEL; VOLUMETRY;

EID: 84870051105     PISSN: 00338419     EISSN: 15271315     Source Type: Journal    
DOI: 10.1148/radiol.12112365     Document Type: Article
Times cited : (159)

References (24)
  • 1
    • 0032744531 scopus 로고    scopus 로고
    • Dose reduction in CT by anatomically adapted tube current modulation. I. Simulation studies
    • Gies M, Kalender WA, Wolf H, Suess C, Madsen M. Dose reduction in CT by anatomically adapted tube current modulation. I. Simulation studies. Med Phys 1999;26(11):2235-2247.
    • (1999) Med Phys , vol.26 , Issue.11 , pp. 2235-2247
    • Gies, M.1    Kalender, W.A.2    Wolf, H.3    Suess, C.4    Madsen, M.5
  • 3
    • 23044432016 scopus 로고    scopus 로고
    • Reducing radiation dose in emergency computed tomography with automatic exposure control techniques
    • DOI 10.1007/s10140-004-0395-7
    • Kalra MK, Rizzo SM, Novelline RA. Reducing radiation dose in emergency computed tomography with automatic exposure control techniques. Emerg Radiol 2005;11(5):267-274. (Pubitemid 41073928)
    • (2005) Emergency Radiology , vol.11 , Issue.5 , pp. 267-274
    • Kalra, M.K.1    Rizzo, S.M.R.2    Novelline, R.A.3
  • 4
    • 33645562681 scopus 로고    scopus 로고
    • CT dose reduction and dose management tools: Overview of available options
    • DOI 10.1148/rg.262055138
    • McCollough CH, Bruesewitz MR, Kofler JM Jr. CT dose reduction and dose management tools: overview of available options. RadioGraphics 2006;26(2):503-512. (Pubitemid 43515321)
    • (2006) Radiographics , vol.26 , Issue.2 , pp. 503-512
    • McCollough, C.H.1    Bruesewitz, M.R.2    Kofler Jr., J.M.3
  • 5
    • 33645830709 scopus 로고    scopus 로고
    • Comparison of angular and combined automatic tube current modulation techniques with constant tube current CT of the abdomen and pelvis
    • DOI 10.2214/AJR.04.1513
    • Rizzo S, Kalra M, Schmidt B, et al. Comparison of angular and combined automatic tube current modulation techniques with constant tube current CT of the abdomen and pelvis. AJR Am J Roentgenol 2006;186(3):673-679. (Pubitemid 46100252)
    • (2006) American Journal of Roentgenology , vol.186 , Issue.3 , pp. 673-679
    • Rizzo, S.1    Kalra, M.2    Schmidt, B.3    Dalal, T.4    Suess, C.5    Flohr, T.6    Blake, M.7    Saini, S.8
  • 6
    • 77953328799 scopus 로고    scopus 로고
    • Automatic exposure control in computed tomography - An evaluation of systems from different manufacturers
    • Söderberg M, Gunnarsson M. Automatic exposure control in computed tomography - an evaluation of systems from different manufacturers. Acta Radiol 2010;51(6):625-634.
    • (2010) Acta Radiol , vol.51 , Issue.6 , pp. 625-634
    • Söderberg, M.1    Gunnarsson, M.2
  • 8
    • 0019485556 scopus 로고
    • A method for describing the doses delivered by transmission X-ray computed tomography
    • DOI 10.1118/1.594995
    • Shope TB, Gagne RM, Johnson GC. A method for describing the doses delivered by transmission x-ray computed tomography. Med Phys 1981;8(4):488-495. (Pubitemid 11122522)
    • (1981) Medical Physics , vol.8 , Issue.4 , pp. 488-495
    • Shope, T.B.1    Gagne, R.M.2    Johnson, G.C.3
  • 9
    • 0036831529 scopus 로고    scopus 로고
    • AAPM/RSNA Physics Tutorial for Residents: Topics in CT. Radiation dose in CT
    • McNitt-Gray MF. AAPM/RSNA Physics Tutorial for Residents: Topics in CT. Radiation dose in CT. RadioGraphics 2002;22(6):1541-1553.
    • (2002) RadioGraphics , vol.22 , Issue.6 , pp. 1541-1553
    • McNitt-Gray, M.F.1
  • 11
    • 78649689114 scopus 로고    scopus 로고
    • Medical Electrical Equipment. Part 2-44: Particular requirements for the safety of xray equipment for computed tomography
    • International Electrotechnical Commission. 3rd ed. Geneva, Switzerland: International Electrotechnical Commission (IEC) Central Office
    • International Electrotechnical Commission. Medical Electrical Equipment. Part 2-44: Particular requirements for the safety of xray equipment for computed tomography. IEC publication No. 60601-2-44. 3rd ed. Geneva, Switzerland: International Electrotechnical Commission (IEC) Central Office, 2012.
    • (2012) IEC Publication No. 60601-2-44
  • 12
    • 0003562238 scopus 로고
    • American Association of Physicists in Medicine. New York, NY: American Association of Physicists in Medicine
    • American Association of Physicists in Medicine. Standardized methods for measuring diagnostic x-ray exposures. New York, NY: American Association of Physicists in Medicine, 1990.
    • (1990) Standardized Methods for Measuring Diagnostic X-ray Exposures
  • 13
    • 0003892092 scopus 로고    scopus 로고
    • European Commission. Luxembourg: European Commission & The Office For Official Publications of the European Communities
    • European Commission. European guidelines on quality criteria for computed tomography (EUR 16262 EN). Luxembourg: European Commission & The Office For Official Publications of the European Communities, 2000.
    • (2000) European Guidelines on Quality Criteria for Computed Tomography (EUR 16262 EN)
  • 14
    • 40049109570 scopus 로고    scopus 로고
    • Managing patient dose in multi-detector computed tomography (MDCT)
    • International Commission on Radiation Protection. Ann ICRP
    • Valentin J; International Commission on Radiation Protection. Managing patient dose in multi-detector computed tomography (MDCT). ICRP Publication 102. Ann ICRP 2007;37(1):1-79, iii.
    • (2007) ICRP Publication 102 , vol.37 , Issue.1
    • Valentin, J.1
  • 15
    • 51549112607 scopus 로고    scopus 로고
    • The measurement, reporting and management of radiation dose in CT (Report #96)
    • American Association of Physicists in Medicine. College Park, Md: American Association of Physicists in Medicine
    • American Association of Physicists in Medicine. The measurement, reporting and management of radiation dose in CT (Report #96). In: AAPM Task Group 23 of the Diagnostic Imaging Council CT Committee. College Park, Md: American Association of Physicists in Medicine, 2008.
    • (2008) AAPM Task Group 23 of the Diagnostic Imaging Council CT Committee
  • 17
    • 0000921289 scopus 로고
    • Some heteroskedasticity-consistent covariance-matrix estimators with improved finite-sample properties
    • Mackinnon JG, White H. Some heteroskedasticity-consistent covariance-matrix estimators with improved finite-sample properties. J Econom 1985;29(3):305-325.
    • (1985) J Econom , vol.29 , Issue.3 , pp. 305-325
    • Mackinnon, J.G.1    White, H.2
  • 18
    • 78649740074 scopus 로고    scopus 로고
    • Patient size and radiation exposure in thoracic, pelvic, and abdominal CT examinations performed with automatic exposure control
    • Israel GM, Cicchiello L, Brink J, Huda W. Patient size and radiation exposure in thoracic, pelvic, and abdominal CT examinations performed with automatic exposure control. AJR Am J Roentgenol 2010;195(6): 1342-1346.
    • (2010) AJR Am J Roentgenol , vol.195 , Issue.6 , pp. 1342-1346
    • Israel, G.M.1    Cicchiello, L.2    Brink, J.3    Huda, W.4
  • 19
    • 38949105939 scopus 로고    scopus 로고
    • Effect of patient size on radiation dose for abdominal MDCT with automatic tube current modulation: Phantom study
    • Schindera ST, Nelson RC, Toth TL, et al. Effect of patient size on radiation dose for abdominal MDCT with automatic tube current modulation: phantom study. AJR Am J Roentgenol 2008;190(2):W100-W105.
    • (2008) AJR Am J Roentgenol , vol.190 , Issue.2
    • Schindera, S.T.1    Nelson, R.C.2    Toth, T.L.3
  • 20
    • 84870037712 scopus 로고    scopus 로고
    • Unintentional errors in CT imaging with use of a constant noise automatic exposure control (AEC) paradigm
    • [abstr]. Oak Brook, Ill: Radiological Society of North America
    • McCollough C, Yu L. Unintentional errors in CT imaging with use of a constant noise automatic exposure control (AEC) paradigm [abstr]. In: Radiological Society of North America Scientific Assembly and Annual Meeting Program. Oak Brook, Ill: Radiological Society of North America, 2008.
    • (2008) Radiological Society of North America Scientific Assembly and Annual Meeting Program
    • McCollough, C.1    Yu, L.2
  • 21
    • 85032843101 scopus 로고    scopus 로고
    • Committee to Assess Health Risks from Exposure to Low Levels of Ionizing Radiation, National Research Council. Washington, DC: National Academies Press
    • Committee to Assess Health Risks from Exposure to Low Levels of Ionizing Radiation, National Research Council. Health Risks from Exposure to Low Levels of Ionizing Radiation: BEIR VII Phase 2. Washington, DC: National Academies Press, 2006.
    • (2006) Health Risks from Exposure to Low Levels of Ionizing Radiation: BEIR VII Phase 2
  • 24
    • 79551676578 scopus 로고    scopus 로고
    • The feasibility of patient size-corrected, scanner-independent organ dose estimates for abdominal CT exams
    • Turner AC, Zhang D, Khatonabadi M, et al. The feasibility of patient size-corrected, scanner-independent organ dose estimates for abdominal CT exams. Med Phys 2011; 38(2):820-829.
    • (2011) Med Phys , vol.38 , Issue.2 , pp. 820-829
    • Turner, A.C.1    Zhang, D.2    Khatonabadi, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.