메뉴 건너뛰기




Volumn 11, Issue 10, 2016, Pages 1927-1936

Virtually transparent surgical instruments in endoscopic surgery with augmentation of obscured regions

Author keywords

Augmented reality; Computer assisted surgery; Endoscopic surgery; Laparoscopic surgery; Medical image processing; Visualization

Indexed keywords

ANASTOMOSIS; ANIMAL EXPERIMENT; ARTICLE; BENCHMARKING; CAMERA; ENDOSCOPE; ENDOSCOPIC SURGERY; ERROR; EXPERIMENTAL PIG; FEMALE; GASTROJEJUNOSTOMY; HUMAN; IN VIVO STUDY; NEEDLE; NONHUMAN; PRIORITY JOURNAL; QUALITATIVE ANALYSIS; SIMULATION; SURGICAL TRAINING; TELESURGERY; ANIMAL; COMPUTER ASSISTED SURGERY; COMPUTER INTERFACE; ENDOSCOPY; EQUIPMENT DESIGN; IMAGE PROCESSING; PIG; PROCEDURES; SURGICAL EQUIPMENT; SUTURE TECHNIQUE;

EID: 84962204989     PISSN: 18616410     EISSN: 18616429     Source Type: Journal    
DOI: 10.1007/s11548-016-1384-5     Document Type: Article
Times cited : (5)

References (21)
  • 1
    • 84988370088 scopus 로고    scopus 로고
    • Bouguet JY (2013) Camera calibration toolbox for matlab. Accessed 2014/1/6
    • Bouguet JY (2013) Camera calibration toolbox for matlab. http://www.vision.caltech.edu/bouguetj/calib_doc/. Accessed 2014/1/6
  • 2
    • 73049086126 scopus 로고    scopus 로고
    • Learning OpenCV: computer vision with the OpenCV Library
    • Bradski G, Kaehler A (2008) Learning OpenCV: computer vision with the OpenCV Library. O’Reilly Media
    • (2008) O’Reilly Media
    • Bradski, G.1    Kaehler, A.2
  • 3
    • 49949117318 scopus 로고    scopus 로고
    • Segmentation and guidance of multiple rigid objects for intra-operative endoscopic vision. In: WDV’05/WDV’06/ICCV’05/ECCV’06 proceedings of the 2005/2006 international conference on dynamical vision. Springer
    • Doignon C, Nageotte F, de Mathelin M (2006) Segmentation and guidance of multiple rigid objects for intra-operative endoscopic vision. In: WDV’05/WDV’06/ICCV’05/ECCV’06 proceedings of the 2005/2006 international conference on dynamical vision. Springer, pp 314–327
    • (2006) pp 314–327
    • Doignon, C.1    Nageotte, F.2    de Mathelin, M.3
  • 4
    • 34250627212 scopus 로고    scopus 로고
    • The extended learning curve for laparoscopic fundoplication: a cohort analysis of 400 consecutive cases
    • COI: 1:STN:280:DC%2BD2s3is1Gnuw%3D%3D, PID: 17436134
    • Gill J, Booth MI, Stratford J, Dehn TCB (2007) The extended learning curve for laparoscopic fundoplication: a cohort analysis of 400 consecutive cases. J Gastrointest Surg 11(4):487–492. doi:10.1007/s11605-007-0132-0
    • (2007) J Gastrointest Surg , vol.11 , Issue.4 , pp. 487-492
    • Gill, J.1    Booth, M.I.2    Stratford, J.3    Dehn, T.C.B.4
  • 6
    • 35448961646 scopus 로고    scopus 로고
    • Influence of instrument size on endoscopic task performance in pediatric intracorporeal knot tying: smaller instruments are better in infants
    • PID: 17516118
    • Lee ACH, Haddad MJ, Hanna GB (2007) Influence of instrument size on endoscopic task performance in pediatric intracorporeal knot tying: smaller instruments are better in infants. Surg Endosc 21(11):2086–2090. doi:10.1007/s00464-007-9311-z
    • (2007) Surg Endosc , vol.21 , Issue.11 , pp. 2086-2090
    • Lee, A.C.H.1    Haddad, M.J.2    Hanna, G.B.3
  • 7
    • 77952554970 scopus 로고    scopus 로고
    • 3-D augmented reality for MRI-guided surgery using integral videography autostereoscopic image overlay
    • Liao H, Inomata T, Sakuma I, Dohi T (2010) 3-D augmented reality for MRI-guided surgery using integral videography autostereoscopic image overlay. IEEE Trans Bio-med Eng 57(6):1476–1486. doi:10.1109/TBME.2010.2040278
    • (2010) IEEE Trans Bio-med Eng , vol.57 , Issue.6 , pp. 1476-1486
    • Liao, H.1    Inomata, T.2    Sakuma, I.3    Dohi, T.4
  • 9
    • 0036203331 scopus 로고    scopus 로고
    • Transcontinental robot-assisted remote telesurgery: feasibility and potential applications
    • PID: 11923603
    • Marescaux J, Leroy J, Rubino F, Smith M, Vix M, Simone M, Mutter D (2002) Transcontinental robot-assisted remote telesurgery: feasibility and potential applications. Ann Surg 235(4):487–492
    • (2002) Ann Surg , vol.235 , Issue.4 , pp. 487-492
    • Marescaux, J.1    Leroy, J.2    Rubino, F.3    Smith, M.4    Vix, M.5    Simone, M.6    Mutter, D.7
  • 10
    • 34250682970 scopus 로고    scopus 로고
    • IEEE/RSJ international conference on intelligent robots and systems, IEEE, pp 2364–2369
    • Nageotte F, Zanne P, Doignon C, Mathelin M (2006) Visual servoing-based endoscopic path following for robot-assisted laparoscopic surgery. In: 2006 IEEE/RSJ international conference on intelligent robots and systems, IEEE, pp 2364–2369. doi:10.1109/IROS.2006.282647
    • (2006) doi:10.1109/IROS.2006.282647
    • Nageotte, F.1    Zanne, P.2    Doignon, C.3
  • 11
    • 34547681708 scopus 로고    scopus 로고
    • IEEE virtual reality conference, IEEE, pp 43–50
    • Navab N, Feuerstein M, Bichlmeier C (2007) Laparoscopic virtual mirror new interaction paradigm for monitor based augmented reality. In: 2007 IEEE virtual reality conference, IEEE, pp 43–50. doi:10.1109/VR.2007.352462
    • (2007) doi:10.1109/VR.2007.352462
    • Navab, N.1    Feuerstein, M.2
  • 12
    • 84988437102 scopus 로고    scopus 로고
    • Abdominal view expansion by retractable camera
    • Okubo T, Nakaguchi T, Hayashi H (2011) Abdominal view expansion by retractable camera. J Signal Process 15(4):311–314
    • (2011) J Signal Process , vol.15 , Issue.4 , pp. 311-314
    • Okubo, T.1    Nakaguchi, T.2    Hayashi, H.3
  • 15
    • 84940285650 scopus 로고    scopus 로고
    • Appearance learning for 3D tracking of robotic surgical tools
    • Reiter A, Allen PK, Zhao T (2013) Appearance learning for 3D tracking of robotic surgical tools. Int J Robot Res 33(2):342–356. doi:10.1177/0278364913507796
    • (2013) Int J Robot Res , vol.33 , Issue.2 , pp. 342-356
    • Reiter, A.1    Allen, P.K.2    Zhao, T.3
  • 16
    • 84858952657 scopus 로고    scopus 로고
    • Single-port-access surgery with a novel magnet camera system
    • Terry BS, Mills ZC, Schoen JA, Rentschler ME (2012) Single-port-access surgery with a novel magnet camera system. IEEE Trans Bio-med Eng 59(4):1187–1193. doi:10.1109/TBME.2012.2187292
    • (2012) IEEE Trans Bio-med Eng , vol.59 , Issue.4 , pp. 1187-1193
    • Terry, B.S.1    Mills, Z.C.2    Schoen, J.A.3    Rentschler, M.E.4
  • 17
    • 84988343290 scopus 로고    scopus 로고
    • Analysis of surgeons who attended laparoscopic surgical skills training programs at Kyushu University. International journal of computer assisted radiology and surgery: 18th Annual Conference of the International Society for
    • Tomikawa M, Kenmotsu H, Uemura M, Konishi K, Ohuchida K, Okazaki K, Ieiri S, Tanoue K, Hashizume M (2014) Analysis of surgeons who attended laparoscopic surgical skills training programs at Kyushu University. International journal of computer assisted radiology and surgery: 18th Annual Conference of the International Society for. Computer Aided Surgery 9(1 Suppl), pp 130–131
    • (2014) Computer Aided Surgery , vol.9 , pp. 130-131
    • Tomikawa, M.1    Kenmotsu, H.2    Uemura, M.3    Konishi, K.4    Ohuchida, K.5    Okazaki, K.6    Ieiri, S.7    Tanoue, K.8    Hashizume, M.9
  • 19
    • 84906938216 scopus 로고    scopus 로고
    • Determination of the latency effects on surgical performance and the acceptable latency levels in telesurgery using the dV-Trainer() simulator. Surg Endosc
    • Xu S, Perez M, Yang K, Perrenot C, Felblinger J, Hubert J (2014) Determination of the latency effects on surgical performance and the acceptable latency levels in telesurgery using the dV-Trainer() simulator. Surg Endosc. doi:10.1007/s00464-014-3504-z
    • (2014) doi:10.1007/s00464-014-3504-z
    • Xu, S.1    Perez, M.2    Yang, K.3    Perrenot, C.4    Felblinger, J.5    Hubert, J.6
  • 21
    • 0000879124 scopus 로고    scopus 로고
    • A flexible new technique for camera calibration
    • Zhang Z (2000) A flexible new technique for camera calibration. IEEE Trans Pattern Anal Mach Intell 22(11):1330–1334. doi:10.1109/34.888718
    • (2000) IEEE Trans Pattern Anal Mach Intell , vol.22 , Issue.11 , pp. 1330-1334
    • Zhang, Z.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.