메뉴 건너뛰기




Volumn 29, Issue 4, 2015, Pages 955-966

A Comparison of the Efficacy and Adverse Effects of Double-Lumen Endobronchial Tubes and Bronchial Blockers in Thoracic Surgery: A Systematic Review and Meta-analysis of Randomized Controlled Trials

Author keywords

adverse effects; bronchial blocker; double lumen endobronchial tube; efficacy; lung isolation; one lung ventilation; thoracic surgery

Indexed keywords

ATELECTASIS; BRONCHIAL TUBE; DOUBLE LUMEN ENDOBRONCHIAL TUBE; ENDOBRONCHIAL BLOCKER; ENDOBRONCHIAL INTUBATION; HOARSENESS; HUMAN; MANTEL HAENSZEL TEST; META ANALYSIS; OUTCOME ASSESSMENT; PRIORITY JOURNAL; RANDOMIZED CONTROLLED TRIAL (TOPIC); RESPIRATORY TRACT INJURY; REVIEW; SORE THROAT; SYSTEMATIC REVIEW; THORAX SURGERY; ADVERSE EFFECTS; COMPARATIVE STUDY; DEVICES; ENDOTRACHEAL INTUBATION; PHARYNGITIS; PROCEDURES; TREATMENT OUTCOME;

EID: 84953347949     PISSN: 10530770     EISSN: 15328422     Source Type: Journal    
DOI: 10.1053/j.jvca.2014.11.017     Document Type: Article
Times cited : (117)

References (36)
  • 2
    • 0000260329 scopus 로고
    • Anaesthesia in thoracic surgery, with special reference to lobectomy: (Section of anaesthetics)
    • I.W. Magill Anaesthesia in thoracic surgery, with special reference to lobectomy: (section of anaesthetics) Proc R Soc Med 29 1936 643 653
    • (1936) Proc R Soc Med , vol.29 , pp. 643-653
    • Magill, I.W.1
  • 3
    • 70450223344 scopus 로고    scopus 로고
    • The use of bronchial blockers for providing one-lung ventilation
    • S.M. Neustein The use of bronchial blockers for providing one-lung ventilation J Cardiothorac Vasc Anesth 23 2009 860 868
    • (2009) J Cardiothorac Vasc Anesth , vol.23 , pp. 860-868
    • Neustein, S.M.1
  • 5
    • 84953360763 scopus 로고    scopus 로고
    • Anaesthesia for thoracic surgery
    • Alston RP, Ranucci M, Myles PS, editors Oxford: Oxford University Press, In press
    • Bussieres JS, Rousseau A: Anaesthesia for thoracic surgery. In: Alston RP, Ranucci M, Myles PS, editors. Textbook of cardiothoracic anesthesia. Oxford: Oxford University Press, In press.
    • Textbook of Cardiothoracic Anesthesia
    • Bussieres, J.S.1    Rousseau, A.2
  • 6
    • 0035154743 scopus 로고    scopus 로고
    • Bronchial blocker compared to double-lumen tube for one-lung ventilation during thoracoscopy
    • C. Bauer, C. Winter, J.G. Hentz, and et al. Bronchial blocker compared to double-lumen tube for one-lung ventilation during thoracoscopy Acta Anaesthesiol Scand 45 2001 250 254
    • (2001) Acta Anaesthesiol Scand , vol.45 , pp. 250-254
    • Bauer, C.1    Winter, C.2    Hentz, J.G.3
  • 7
    • 0029856033 scopus 로고    scopus 로고
    • Comparison of a modified double-lumen endotracheal tube with a single-lumen tube with enclosed bronchial blocker
    • J.H. Campos, D.K. Reasoner, and J.R. Moyers Comparison of a modified double-lumen endotracheal tube with a single-lumen tube with enclosed bronchial blocker Anesth Analg 83 1996 1268 1272
    • (1996) Anesth Analg , vol.83 , pp. 1268-1272
    • Campos, J.H.1    Reasoner, D.K.2    Moyers, J.R.3
  • 8
    • 0031956767 scopus 로고    scopus 로고
    • Is there a better right-sided tube for one-lung ventilation? A comparison of the right-sided double-lumen tube with the single-lumen tube with right-sided enclosed bronchial blocker
    • J.H. Campos, and F.C. Massa Is there a better right-sided tube for one-lung ventilation? A comparison of the right-sided double-lumen tube with the single-lumen tube with right-sided enclosed bronchial blocker Anesth Analg 86 1998 696 700
    • (1998) Anesth Analg , vol.86 , pp. 696-700
    • Campos, J.H.1    Massa, F.C.2
  • 9
    • 0037223284 scopus 로고    scopus 로고
    • A comparison of a left-sided Broncho-Cath with the torque control blocker Univent and the wire-guided blocker
    • J.H. Campos, and K.H. Kernstine A comparison of a left-sided Broncho-Cath with the torque control blocker Univent and the wire-guided blocker Anesth Analg 96 2003 283 289
    • (2003) Anesth Analg , vol.96 , pp. 283-289
    • Campos, J.H.1    Kernstine, K.H.2
  • 10
    • 33644965437 scopus 로고    scopus 로고
    • Devices for lung isolation used by anesthesiologists with limited thoracic experience: Comparison of double-lumen endotracheal tube, Univent torque control blocker, and Arndt wire-guided endobronchial blocker
    • J.H. Campos, E.A. Hallam, T. Van Natta, and et al. Devices for lung isolation used by anesthesiologists with limited thoracic experience: Comparison of double-lumen endotracheal tube, Univent torque control blocker, and Arndt wire-guided endobronchial blocker Anesthesiology 104 2006 261 266
    • (2006) Anesthesiology , vol.104 , pp. 261-266
    • Campos, J.H.1    Hallam, E.A.2    Van Natta, T.3
  • 11
    • 84866362689 scopus 로고    scopus 로고
    • Lung isolation in the morbidly obese patient: A comparison of a left-sided double-lumen tracheal tube with the Arndt wire-guided blocker
    • J.H. Campos, E.A. Hallam, and K. Ueda Lung isolation in the morbidly obese patient: a comparison of a left-sided double-lumen tracheal tube with the Arndt wire-guided blocker Br J Anaesth 109 2012 630 635
    • (2012) Br J Anaesth , vol.109 , pp. 630-635
    • Campos, J.H.1    Hallam, E.A.2    Ueda, K.3
  • 12
    • 67650527330 scopus 로고    scopus 로고
    • Comparison of the deflecting-tip bronchial blocker with a wire-guided blocker or left-sided double-lumen tube
    • V. Dumans-Nizard, N. Liu, P.A. Laloë, and et al. Comparison of the deflecting-tip bronchial blocker with a wire-guided blocker or left-sided double-lumen tube J Cardiothorac Vasc Anesth 23 2009 501 505
    • (2009) J Cardiothorac Vasc Anesth , vol.23 , pp. 501-505
    • Dumans-Nizard, V.1    Liu, N.2    Laloë, P.A.3
  • 13
    • 0346729938 scopus 로고    scopus 로고
    • Lung isolation during port-access cardiac surgery: Double-lumen endotracheal tube versus single-lumen endotracheal tube with a bronchial blocker
    • H.P. Grocott, T.R. Darrow, D.L. Whiteheart, and et al. Lung isolation during port-access cardiac surgery: Double-lumen endotracheal tube versus single-lumen endotracheal tube with a bronchial blocker J Cardiothorac Vasc Anesth 17 2003 725 727
    • (2003) J Cardiothorac Vasc Anesth , vol.17 , pp. 725-727
    • Grocott, H.P.1    Darrow, T.R.2    Whiteheart, D.L.3
  • 14
    • 33748205983 scopus 로고    scopus 로고
    • Airway injuries after one-lung ventilation: A comparison between double-lumen tube and endobronchial blocker: A randomized, prospective, controlled trial
    • H. Knoll, S. Ziegeler, J.U. Schreiber, and et al. Airway injuries after one-lung ventilation: A comparison between double-lumen tube and endobronchial blocker: A randomized, prospective, controlled trial Anesthesiology 105 2006 471 477
    • (2006) Anesthesiology , vol.105 , pp. 471-477
    • Knoll, H.1    Ziegeler, S.2    Schreiber, J.U.3
  • 15
    • 84874657823 scopus 로고    scopus 로고
    • Efficiency, efficacy, and safety of EZ-blocker compared with left-sided double-lumen tube for one-lung ventilation
    • J. Mourisse, J. Liesveld, A. Verhagen, and et al. Efficiency, efficacy, and safety of EZ-blocker compared with left-sided double-lumen tube for one-lung ventilation Anesthesiology 118 2013 550 561
    • (2013) Anesthesiology , vol.118 , pp. 550-561
    • Mourisse, J.1    Liesveld, J.2    Verhagen, A.3
  • 16
    • 63849327696 scopus 로고    scopus 로고
    • Choosing a lung isolation device for thoracic surgery: A randomized trial of three bronchial blockers versus double-lumen tubes
    • M. Narayanaswamy, K. McRae, P. Slinger, and et al. Choosing a lung isolation device for thoracic surgery: A randomized trial of three bronchial blockers versus double-lumen tubes Anesth Analg 108 2009 1097 1101
    • (2009) Anesth Analg , vol.108 , pp. 1097-1101
    • Narayanaswamy, M.1    McRae, K.2    Slinger, P.3
  • 17
    • 79957525418 scopus 로고    scopus 로고
    • Randomized clinical trial comparing double-lumen tube and EZ-Blocker for single-lung ventilation
    • K. Ruetzler, G. Grubhofer, W. Schmid, and et al. Randomized clinical trial comparing double-lumen tube and EZ-Blocker for single-lung ventilation Br J Anaesth 106 2011 896 902
    • (2011) Br J Anaesth , vol.106 , pp. 896-902
    • Ruetzler, K.1    Grubhofer, G.2    Schmid, W.3
  • 18
    • 66249132028 scopus 로고    scopus 로고
    • Sore throat or hoarse voice with bronchial blockers or double-lumen tubes for lung isolation: A randomised, prospective trial
    • T. Zhong, W. Wang, J. Chen, and et al. Sore throat or hoarse voice with bronchial blockers or double-lumen tubes for lung isolation: A randomised, prospective trial Anaesthes Intensive Care 37 2009 441 446
    • (2009) Anaesthes Intensive Care , vol.37 , pp. 441-446
    • Zhong, T.1    Wang, W.2    Chen, J.3
  • 19
    • 3042767585 scopus 로고    scopus 로고
    • A comparison of the Arndt endobronchial blocker with a double lumen tube in robotic cardiac surgery [article in German]
    • A. Lehmann, C. Zeitler, J. Lang, and et al. A comparison of the Arndt endobronchial blocker with a double lumen tube in robotic cardiac surgery [article in German] Anasthesiol Intensivmed Notfallmed Schmerzther 39 2004 353 359
    • (2004) Anasthesiol Intensivmed Notfallmed Schmerzther , vol.39 , pp. 353-359
    • Lehmann, A.1    Zeitler, C.2    Lang, J.3
  • 20
    • 39549109334 scopus 로고    scopus 로고
    • Comparison of the double-lumen endotracheal tube and the Arndt bronchial blocker used by inexperienced anesthesiologists in right- and left-sided thoracic surgery [article in Spanish]
    • E. Vilà, R. Garcia Guasch, C. Ibáñez, and et al. Comparison of the double-lumen endotracheal tube and the Arndt bronchial blocker used by inexperienced anesthesiologists in right- and left-sided thoracic surgery [article in Spanish] Rev Esp Anestesiol Reanim 54 2007 602 607
    • (2007) Rev Esp Anestesiol Reanim , vol.54 , pp. 602-607
    • Vilà, E.1    Garcia Guasch, R.2    Ibáñez, C.3
  • 21
    • 84869799282 scopus 로고    scopus 로고
    • A comparison of double-lumen endotracheal tube with univent blocker and bronchial blocker during thoracic surgical anesthesia [article in Chinese]
    • H. Zheng, Y. Duan, W.M. Geng, and et al. A comparison of double-lumen endotracheal tube with univent blocker and bronchial blocker during thoracic surgical anesthesia [article in Chinese] Zhonghua Yi Xue Za Zhi 92 2012 2481 2484
    • (2012) Zhonghua Yi Xue Za Zhi , vol.92 , pp. 2481-2484
    • Zheng, H.1    Duan, Y.2    Geng, W.M.3
  • 22
    • 69149107165 scopus 로고    scopus 로고
    • Preferred reporting items for systematic reviews and meta-analyses: The PRISMA statement
    • D. Moher, A. Liberati, J. Tetzlaff, and et al. Preferred reporting items for systematic reviews and meta-analyses: The PRISMA statement Ann Intern Med 151 2009 264 269
    • (2009) Ann Intern Med , vol.151 , pp. 264-269
    • Moher, D.1    Liberati, A.2    Tetzlaff, J.3
  • 25
    • 74849132824 scopus 로고    scopus 로고
    • The Nordic Cochrane Centre, The Cochrane Collaboration Copenhagen
    • Review Manager (RevMan) computer program Version 5.0 2008 The Nordic Cochrane Centre, The Cochrane Collaboration Copenhagen
    • (2008) Version 5.0
  • 26
    • 84959801619 scopus 로고
    • Statistical aspects of the analysis of data from retrospective studies of disease
    • N. Mantel, and W. Haenszel Statistical aspects of the analysis of data from retrospective studies of disease J Natl Cancer Inst 22 1959 719 748
    • (1959) J Natl Cancer Inst , vol.22 , pp. 719-748
    • Mantel, N.1    Haenszel, W.2
  • 27
    • 0041876133 scopus 로고    scopus 로고
    • Measuring inconsistency in meta-analyses
    • J.P. Higgins, S.G. Thompson, J.J. Deeks, and et al. Measuring inconsistency in meta-analyses BMJ 327 2003 557 560
    • (2003) BMJ , vol.327 , pp. 557-560
    • Higgins, J.P.1    Thompson, S.G.2    Deeks, J.J.3
  • 29
    • 56349102366 scopus 로고    scopus 로고
    • Pro: The new bronchial blockers are preferable to double-lumen tubes for lung isolation
    • E. Cohen Pro: The new bronchial blockers are preferable to double-lumen tubes for lung isolation J Cardiothorac Vasc Anesth 22 2008 920 924
    • (2008) J Cardiothorac Vasc Anesth , vol.22 , pp. 920-924
    • Cohen, E.1
  • 30
    • 0036021879 scopus 로고    scopus 로고
    • The use of a bronchial blocker compared with a double-lumen tube for single-lung ventilation during minimally invasive direct coronary artery bypass surgery
    • J. Ender, A.M. Bury, J. Raumanns, and et al. The use of a bronchial blocker compared with a double-lumen tube for single-lung ventilation during minimally invasive direct coronary artery bypass surgery J Cardiothorac Vasc Anesth 16 2002 452 455
    • (2002) J Cardiothorac Vasc Anesth , vol.16 , pp. 452-455
    • Ender, J.1    Bury, A.M.2    Raumanns, J.3
  • 31
    • 0031924702 scopus 로고    scopus 로고
    • Flow resistances of disposable double-lumen, single-lumen, and Univent tubes
    • P.D. Slinger, and L. Lesiuk Flow resistances of disposable double-lumen, single-lumen, and Univent tubes J Cardiothorac Vasc Anesth 12 1998 142 144
    • (1998) J Cardiothorac Vasc Anesth , vol.12 , pp. 142-144
    • Slinger, P.D.1    Lesiuk, L.2
  • 32
    • 56349091596 scopus 로고    scopus 로고
    • Con: The new bronchial blockers are not preferable to double-lumen tubes for lung isolation
    • P. Slinger Con: The new bronchial blockers are not preferable to double-lumen tubes for lung isolation J Cardiothorac Vasc Anesth 22 2008 925 929
    • (2008) J Cardiothorac Vasc Anesth , vol.22 , pp. 925-929
    • Slinger, P.1
  • 33
    • 84887910875 scopus 로고    scopus 로고
    • Double-lumen tube tracheal intubation using a rigid video-stylet: A randomized controlled comparison with the Macintosh laryngoscope
    • M. Yang, J.A. Kim, H.J. Ahn, and et al. Double-lumen tube tracheal intubation using a rigid video-stylet: A randomized controlled comparison with the Macintosh laryngoscope Br J Anaesth 111 2013 990 995
    • (2013) Br J Anaesth , vol.111 , pp. 990-995
    • Yang, M.1    Kim, J.A.2    Ahn, H.J.3
  • 36
    • 84885910021 scopus 로고    scopus 로고
    • Comparison of techniques for double-lumen endobronchial intubation: 90 degrees or 180 degrees rotation during advancement through the glottis
    • J.H. Seo, T.K. Kwon, Y. Jeon, and et al. Comparison of techniques for double-lumen endobronchial intubation: 90 degrees or 180 degrees rotation during advancement through the glottis Br J Anaesth 111 2013 812 817
    • (2013) Br J Anaesth , vol.111 , pp. 812-817
    • Seo, J.H.1    Kwon, T.K.2    Jeon, Y.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.