Efficiency, efficacy, and safety of EZ-blocker compared with left-sided double-lumen tube for one-lung ventilation

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ARTICLE; ATELECTASIS; BRONCHIAL BLOCKER; CATHETER; CONTROLLED STUDY; DOUBLE LUMEN TUBE; FEMALE; HEMATOMA; HUMAN; INTERMETHOD COMPARISON; MAJOR CLINICAL STUDY; MALE; ONE LUNG VENTILATION; POSTOPERATIVE COMPLICATION; PRIORITY JOURNAL; SINGLE BLIND PROCEDURE; SORE THROAT;

EID: 84874657823     PISSN: 00033022     EISSN: 15281175     Source Type: Journal    
DOI: 10.1097/ALN.0b013e3182834f2d     Document Type: Article
Times cited : (114)

References (25)
  • 1
    • 0026663046 scopus 로고
    • Reliability of auscultation in positioning of double-lumen endobronchial tubes
    • Alliaume B, Coddens J, Deloof T: Reliability of auscultation in positioning of double-lumen endobronchial tubes. Can J Anaesth 1992; 39:687-90
    • (1992) Can J Anaesth , vol.39 , pp. 687-690
    • Alliaume, B.1    Coddens, J.2    Deloof, T.3
  • 2
    • 0031913886 scopus 로고    scopus 로고
    • Role of fiberoptic bronchoscopy in conjunction with the use of double-lumen tubes for thoracic anesthesia: A prospective study
    • Klein U, Karzai W, Bloos F, Wohlfarth M, Gottschall R, Fritz H, Gugel M, Seifert A: Role of fiberoptic bronchoscopy in conjunction with the use of double-lumen tubes for thoracic anesthesia: A prospective study. Anesthesiology 1998; 88:346-50
    • (1998) Anesthesiology , vol.88 , pp. 346-350
    • Klein, U.1    Karzai, W.2    Bloos, F.3    Wohlfarth, M.4    Gottschall, R.5    Fritz, H.6    Gugel, M.7    Seifert, A.8
  • 3
    • 0027081047 scopus 로고
    • The utility of a double-lumen tube for one-lung ventilation in a variety of noncardiac thoracic surgical procedures
    • L ewis JW Jr, Serwin JP, Gabriel FS, Bastanfar M, Jacobsen G: The utility of a double-lumen tube for one-lung ventilation in a variety of noncardiac thoracic surgical procedures. J Cardiothorac Vasc Anesth 1992; 6:705-10
    • (1992) J Cardiothorac Vasc Anesth , vol.6 , pp. 705-710
    • Lewis Jr., J.W.1    Serwin, J.P.2    Gabriel, F.S.3    Bastanfar, M.4    Jacobsen, G.5
  • 5
    • 0023004111 scopus 로고
    • Placement of doublelumen endobronchial tubes: Correlation between clinical impressions and bronchoscopic findings
    • S mith GB, Hirsch NP, Ehrenwerth J: Placement of doublelumen endobronchial tubes: Correlation between clinical impressions and bronchoscopic findings. Br J Anaesth 1986; 58:1317-20
    • (1986) Br J Anaesth , vol.58 , pp. 1317-1320
    • Smith, G.B.1    Hirsch, N.P.2    Ehrenwerth, J.3
  • 6
    • 33748205983 scopus 로고    scopus 로고
    • Airway injuries after onelung ventilation: A comparison between double-lumen tube and endobronchial blocker. A randomized, prospective, controlled trial
    • Knoll H, Ziegeler S, Schreiber JU, Buchinger H, Bialas P, Semyonov K, Graeter T, Mencke T: Airway injuries after onelung ventilation: A comparison between double-lumen tube and endobronchial blocker. A randomized, prospective, controlled trial. Anesthesiology 2006; 105:471-7
    • (2006) Anesthesiology , vol.105 , pp. 471-477
    • Knoll, H.1    Ziegeler, S.2    Schreiber, J.U.3    Buchinger, H.4    Bialas, P.5    Semyonov, K.6    Graeter, T.7    Mencke, T.8
  • 8
    • 63849327696 scopus 로고    scopus 로고
    • Choosing a lung isolation device for thoracic surgery: A randomized trial of three bronchial blockers versus double-lumen tubes
    • Narayanaswamy M, McRae K, Slinger P, Dugas G, Kanellakos GW, Roscoe A, Lacroix M: Choosing a lung isolation device for thoracic surgery: A randomized trial of three bronchial blockers versus double-lumen tubes. Anesth Analg 2009; 108:1097-101
    • (2009) Anesth Analg , vol.108 , pp. 1097-1101
    • Narayanaswamy, M.1    McRae, K.2    Slinger, P.3    Dugas, G.4    Kanellakos, G.W.5    Roscoe, A.6    Lacroix, M.7
  • 9
    • 72749085073 scopus 로고    scopus 로고
    • Lung isolation with a new Y-shaped endobronchial blocking device, the EZ-Blocker
    • Mungroop HE , Wai PT, Morei MN, Loef BG, Epema AH: Lung isolation with a new Y-shaped endobronchial blocking device, the EZ-Blocker. Br J Anaesth 2010; 104:119-20
    • (2010) Br J Anaesth , vol.104 , pp. 119-120
    • Mungroop, H.E.1    Wai, P.T.2    Morei, M.N.3    Loef, B.G.4    Epema, A.H.5
  • 10
    • 20444388672 scopus 로고    scopus 로고
    • Tracheal width and left doublelumen tube size: A formula to estimate left-bronchial width
    • Brodsky JB, Lemmens HJ: Tracheal width and left doublelumen tube size: A formula to estimate left-bronchial width. J Clin Anesth 2005; 17:267-70
    • (2005) J Clin Anesth , vol.17 , pp. 267-270
    • Brodsky, J.B.1    Lemmens, H.J.2
  • 12
    • 38149107469 scopus 로고    scopus 로고
    • A logical approach to the selection and insertion of double lumen tubes
    • Russell WJ: A logical approach to the selection and insertion of double lumen tubes. Curr Opin Anaesthesiol 2008; 21:37-40
    • (2008) Curr Opin Anaesthesiol , vol.21 , pp. 37-40
    • Russell, W.J.1
  • 14
    • 0021701206 scopus 로고
    • Difficult tracheal intubation in obstetrics
    • Cormack RS, Lehane J: Difficult tracheal intubation in obstetrics. Anaesthesia 1984; 39:1105-11
    • (1984) Anaesthesia , vol.39 , pp. 1105-1111
    • Cormack, R.S.1    Lehane, J.2
  • 15
    • 0029962901 scopus 로고    scopus 로고
    • Placement of left double-lumen endobronchial tubes with or without a stylet
    • L ieberman D, Littleford J, Horan T, Unruh H: Placement of left double-lumen endobronchial tubes with or without a stylet. Can J Anaesth 1996; 43:238-42
    • (1996) Can J Anaesth , vol.43 , pp. 238-242
    • Ieberman D, L.1    Littleford, J.2    Horan, T.3    Unruh, H.4
  • 16
    • 0026653725 scopus 로고
    • Sixteen S-squared over D-squared: A relation for crude sample size estimates
    • L ehr R: Sixteen S-squared over D-squared: A relation for crude sample size estimates. Stat Med 1992; 11:1099-102
    • (1992) Stat Med , vol.11 , pp. 1099-1102
    • Lehr, R.1
  • 17
    • 0037223284 scopus 로고    scopus 로고
    • A comparison of a left-sided Broncho-Cath with the torque control blocker univent and the wire-guided blocker
    • Campos JH, Kernstine KH: A comparison of a left-sided Broncho-Cath with the torque control blocker univent and the wire-guided blocker. Anesth Analg 2003; 96:283-9
    • (2003) Anesth Analg , vol.96 , pp. 283-289
    • Campos, J.H.1    Kernstine, K.H.2
  • 18
    • 0027494519 scopus 로고
    • The position of a double-lumen tube should be routinely determined by fiberoptic bronchoscopy
    • Benumof JL: The position of a double-lumen tube should be routinely determined by fiberoptic bronchoscopy. J Cardiothorac Vasc Anesth 1993; 7:513-4
    • (1993) J Cardiothorac Vasc Anesth , vol.7 , pp. 513-514
    • Benumof, J.L.1
  • 19
    • 0037628935 scopus 로고    scopus 로고
    • Left double-lumen tubes: Clinical experience with 1,170 patients
    • Brodsky JB, Lemmens HJ: Left double-lumen tubes: Clinical experience with 1,170 patients. J Cardiothorac Vasc Anesth 2003; 17:289-98
    • (2003) J Cardiothorac Vasc Anesth , vol.17 , pp. 289-298
    • Brodsky, J.B.1    Lemmens, H.J.2
  • 20
    • 0142212423 scopus 로고    scopus 로고
    • An update on bronchial blockers during lung separation techniques in adults
    • Campos JH: An update on bronchial blockers during lung separation techniques in adults. Anesth Analg 2003; 97:1266-74
    • (2003) Anesth Analg , vol.97 , pp. 1266-1274
    • Campos, J.H.1
  • 21
    • 33644965437 scopus 로고    scopus 로고
    • Devices for lung isolation used by anesthesiologists with limited thoracic experience: Comparison of double-lumen endotracheal tube Univent torque control blocker, and Arndt wire-guided endobronchial blocker
    • discussion 5A
    • Campos JH, Hallam EA, Van Natta T, Kernstine KH: Devices for lung isolation used by anesthesiologists with limited thoracic experience: Comparison of double-lumen endotracheal tube, Univent torque control blocker, and Arndt wire-guided endobronchial blocker. Anesthesiology 2006; 104:261-6; discussion 5A
    • (2006) Anesthesiology , vol.104 , pp. 261-266
    • Campos, J.H.1    Hallam, E.A.2    Van Natta, T.3    Kernstine, K.H.4
  • 22
    • 33846096828 scopus 로고    scopus 로고
    • Which device should be considered the best for lung isolation: Double-lumen endotracheal tube versus bronchial blockers
    • Campos JH: Which device should be considered the best for lung isolation: Double-lumen endotracheal tube versus bronchial blockers. Curr Opin Anaesthesiol 2007; 20:27-31
    • (2007) Curr Opin Anaesthesiol , vol.20 , pp. 27-31
    • Campos, J.H.1
  • 24
    • 56349102366 scopus 로고    scopus 로고
    • Pro: The new bronchial blockers are preferable to double-lumen tubes for lung isolation
    • Cohen E: Pro: The new bronchial blockers are preferable to double-lumen tubes for lung isolation. J Cardiothorac Vasc Anesth 2008; 22:920-4
    • (2008) J Cardiothorac Vasc Anesth , vol.22 , pp. 920-924
    • Cohen, E.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.