메뉴 건너뛰기




Volumn 12, Issue 2, 1998, Pages 142-144

Flow resistances of disposable double-lumen, single-lumen, and Univent tubes

Author keywords

Bronchial blockers; Endobronchial intubation; Endotracheal tubes; Equipment; One lung ventilation; Thoracic anesthesia; Thoracic surgery

Indexed keywords

AIRWAY RESISTANCE; ARTICLE; CONTROLLED STUDY; DOUBLE LUMEN TUBE; ENDOTRACHEAL TUBE; PRESSURE GRADIENT; PRIORITY JOURNAL;

EID: 0031924702     PISSN: 10530770     EISSN: None     Source Type: Journal    
DOI: 10.1016/S1053-0770(98)90320-2     Document Type: Article
Times cited : (76)

References (14)
  • 1
    • 0026563753 scopus 로고
    • Airway management during anesthesia for double-lung transplantation using a single-lumen endotracheal tube with an enclosed bronchial blocker
    • Scheller MS, Kriett JM, Smith CM, Jamieson SW: Airway management during anesthesia for double-lung transplantation using a single-lumen endotracheal tube with an enclosed bronchial blocker. J Cardiothorac Vasc Anesth 6:204-207, 1992
    • (1992) J Cardiothorac Vasc Anesth , vol.6 , pp. 204-207
    • Scheller, M.S.1    Kriett, J.M.2    Smith, C.M.3    Jamieson, S.W.4
  • 2
    • 0027518606 scopus 로고
    • Pro: One-lung ventilation is best accomplished with the Univent endotracheal tube
    • Gayes JM: Pro: One-lung ventilation is best accomplished with the Univent endotracheal tube. J Cardiothorac Vasc Anesth 7:103-107, 1993
    • (1993) J Cardiothorac Vasc Anesth , vol.7 , pp. 103-107
    • Gayes, J.M.1
  • 3
    • 0028356786 scopus 로고
    • Univent endotracheal tube: Twelve-year experience
    • Inoue H: Univent endotracheal tube: Twelve-year experience. J Thorac Cardiovasc Surg 107:1171-1172, 1994
    • (1994) J Thorac Cardiovasc Surg , vol.107 , pp. 1171-1172
    • Inoue, H.1
  • 4
    • 0022120081 scopus 로고
    • New endotracheal tube (Univent tube) for selective blockade of one lung
    • Kamaya H, Krishna PR: New endotracheal tube (Univent tube) for selective blockade of one lung. Anesthesiology 63:342-343, 1985
    • (1985) Anesthesiology , vol.63 , pp. 342-343
    • Kamaya, H.1    Krishna, P.R.2
  • 5
    • 0024563182 scopus 로고
    • Measurement of the flow-resistive properties of double-lumen bronchial tubes in vitro
    • Chirandra M, Rossi A, Manani G, et al: Measurement of the flow-resistive properties of double-lumen bronchial tubes in vitro. Anaesthesia 44:335-340, 1989
    • (1989) Anaesthesia , vol.44 , pp. 335-340
    • Chirandra, M.1    Rossi, A.2    Manani, G.3
  • 6
    • 0021331359 scopus 로고
    • Comparison of the resistances of double-lumen endobronchial tubes
    • Hammond JE, Wright DJ: Comparison of the resistances of double-lumen endobronchial tubes. Br J Anaesth 56:299-301, 1984
    • (1984) Br J Anaesth , vol.56 , pp. 299-301
    • Hammond, J.E.1    Wright, D.J.2
  • 7
    • 0003877048 scopus 로고
    • Oxford, England. Butterworth and Heinemann
    • Nunn JF: Applied Respiratory Physiology. Oxford, England. Butterworth and Heinemann, 1993, pp 61-67
    • (1993) Applied Respiratory Physiology , pp. 61-67
    • Nunn, J.F.1
  • 8
    • 0019415745 scopus 로고
    • Fluid dynamics in tracheal pressure measurement
    • Chang KH, Mortola JP: Fluid dynamics in tracheal pressure measurement. J Appl Physiol 51:218-225, 1981
    • (1981) J Appl Physiol , vol.51 , pp. 218-225
    • Chang, K.H.1    Mortola, J.P.2
  • 9
    • 0024394440 scopus 로고
    • In vitro versus in vivo comparison of endotracheal tube resistance
    • Wright PE, Marini JJ, Bernard GR: In vitro versus in vivo comparison of endotracheal tube resistance. Ann Rev Resp Dis 140:10-16, 1989
    • (1989) Ann Rev Resp Dis , vol.140 , pp. 10-16
    • Wright, P.E.1    Marini, J.J.2    Bernard, G.R.3
  • 11
    • 0016307397 scopus 로고
    • Endobronchial tube resistances
    • Lack JA: Endobronchial tube resistances. Br J Anaesth 46:461-462, 1974
    • (1974) Br J Anaesth , vol.46 , pp. 461-462
    • Lack, J.A.1
  • 12
    • 0000163846 scopus 로고
    • The prevention of spread during pulmonary resection by the use of a double-lumen catheter
    • Bjork VO, Carlens E: The prevention of spread during pulmonary resection by the use of a double-lumen catheter. J Thorac Surg 20:151, 1950
    • (1950) J Thorac Surg , vol.20 , pp. 151
    • Bjork, V.O.1    Carlens, E.2
  • 13
    • 0000091955 scopus 로고
    • Low-resistance double-lumen endotracheal tubes
    • Robertshaw FL: Low-resistance double-lumen endotracheal tubes. Br J Anaesth 34:576, 1962
    • (1962) Br J Anaesth , vol.34 , pp. 576
    • Robertshaw, F.L.1
  • 14
    • 0029874849 scopus 로고    scopus 로고
    • Auto-positive end-expiratory pressure during one-lung ventilation using a double-lumen endobronchial tube
    • Yokota K, Toriumi T, Sari A, et al: Auto-positive end-expiratory pressure during one-lung ventilation using a double-lumen endobronchial tube. Anesth Analg 82:1007-1010, 1996
    • (1996) Anesth Analg , vol.82 , pp. 1007-1010
    • Yokota, K.1    Toriumi, T.2    Sari, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.