Con: The New Bronchial Blockers Are Not Preferable to Double-Lumen Tubes for Lung Isolation

Author keywords

bronchial blocker; double lumen tube; lung isolation; one lung ventilation

Indexed keywords

ARNDT WIRE GUIDED ENDOBRONCHIAL BLOCKER; ARTICLE; CATHETER COMPLICATION; CLINICAL FEATURE; COHEN TIP DEFLECTING ENDOBRONCHIAL BLOCKER; DISEASE SEVERITY; DOUBLE LUMEN TUBE; FIBEROPTIC BRONCHOSCOPY; FUJI UNIBLOCKER; HUMAN; HYPOXIA; ISOLATION PROCEDURE; LUNG COLLAPSE; LUNG HEMORRHAGE; LUNG INJURY; LUNG RESECTION; LUNG RESISTANCE; LUNG VENTILATION; MEDICAL INSTRUMENTATION; PNEUMOTHORAX; PRIORITY JOURNAL; SPIRAL COMPUTER ASSISTED TOMOGRAPHY; SUBCUTANEOUS EMPHYSEMA; THORAX RADIOGRAPHY; TRACHEOSTOMY;

EID: 56349091596     PISSN: 10530770     EISSN: None     Source Type: Journal    
DOI: 10.1053/j.jvca.2008.09.001     Document Type: Note
Times cited : (27)

References (22)
  • 1
    • 14544286014 scopus 로고    scopus 로고
    • Progress in lung separation
    • Campos J.H. Progress in lung separation. Thorac Surg Clin 15 (2005) 71-84
    • (2005) Thorac Surg Clin , vol.15 , pp. 71-84
    • Campos, J.H.1
  • 3
    • 0032982092 scopus 로고    scopus 로고
    • One-lung ventilation when intubation is difficult: Presentation of a new endobronchial blocker
    • Arndt G.A., DeLessio S.T., Kranner P.W., et al. One-lung ventilation when intubation is difficult: Presentation of a new endobronchial blocker. Acta Anaesthesiol Scand 43 (1999) 356-358
    • (1999) Acta Anaesthesiol Scand , vol.43 , pp. 356-358
    • Arndt, G.A.1    DeLessio, S.T.2    Kranner, P.W.3
  • 4
    • 33845388845 scopus 로고    scopus 로고
    • Sequential lobar-lung-lobar isolation using a deflecting tip bronchial blocker
    • Ruiz P. Sequential lobar-lung-lobar isolation using a deflecting tip bronchial blocker. J Clin Anesth 18 (2006) 620-623
    • (2006) J Clin Anesth , vol.18 , pp. 620-623
    • Ruiz, P.1
  • 5
    • 37249088328 scopus 로고    scopus 로고
    • Endobronchial bleeding associated with blunt chest trauma treated by bronchial occlusion with a Univent
    • Nishiumi N., Nakagawa T., Masuda R., et al. Endobronchial bleeding associated with blunt chest trauma treated by bronchial occlusion with a Univent. Ann Thorac Surg 85 (2008) 245-250
    • (2008) Ann Thorac Surg , vol.85 , pp. 245-250
    • Nishiumi, N.1    Nakagawa, T.2    Masuda, R.3
  • 6
    • 0032871486 scopus 로고    scopus 로고
    • Computed tomography based tracheobronchial image reconstruction allows selection of the individually appropriate double-lumen tube size
    • Eberle B., Weiler N., and Vogel N. Computed tomography based tracheobronchial image reconstruction allows selection of the individually appropriate double-lumen tube size. J Cardiothorac Vasc Anesth 13 (1999) 532-535
    • (1999) J Cardiothorac Vasc Anesth , vol.13 , pp. 532-535
    • Eberle, B.1    Weiler, N.2    Vogel, N.3
  • 7
    • 85119795660 scopus 로고    scopus 로고
    • Prediction of double-lumen tracheal tube depth
    • Bahk J.H., and Oh Y.S. Prediction of double-lumen tracheal tube depth. J Cardiothorac Vasc Anesth 16 (1999) 370-375
    • (1999) J Cardiothorac Vasc Anesth , vol.16 , pp. 370-375
    • Bahk, J.H.1    Oh, Y.S.2
  • 8
    • 29844453633 scopus 로고    scopus 로고
    • Optimal depth of insertion of left-sided double-lumen endobronchial tubes cannot be predicted from body height in below average-sized adult patients
    • Yasumoto M., Higa K., Nitahara K., et al. Optimal depth of insertion of left-sided double-lumen endobronchial tubes cannot be predicted from body height in below average-sized adult patients. Eur J Anaesthesiol 23 (2006) 42-46
    • (2006) Eur J Anaesthesiol , vol.23 , pp. 42-46
    • Yasumoto, M.1    Higa, K.2    Nitahara, K.3
  • 9
    • 0037628935 scopus 로고    scopus 로고
    • Left double-lumen tubes: Clinical experience with 1,170 patients
    • Brodsky J.B., and Lemmens J.M.H. Left double-lumen tubes: Clinical experience with 1,170 patients. J Cardiothorac Vasc Anesth 17 (2003) 289-295
    • (2003) J Cardiothorac Vasc Anesth , vol.17 , pp. 289-295
    • Brodsky, J.B.1    Lemmens, J.M.H.2
  • 10
    • 0036252979 scopus 로고    scopus 로고
    • Pro: Right-sided double-lumen endotracheal tubes should be used routinely in thoracic surgery
    • Campos J.H., and Gomez M.N. Pro: Right-sided double-lumen endotracheal tubes should be used routinely in thoracic surgery. J Cardiothorac Vasc Anesth 16 (2002) 246-249
    • (2002) J Cardiothorac Vasc Anesth , vol.16 , pp. 246-249
    • Campos, J.H.1    Gomez, M.N.2
  • 11
    • 0742272007 scopus 로고    scopus 로고
    • Double-lumen tube location predicts tube malposition and hypoxemia during one-lung ventilation
    • Inoue S., Nishimine N., Kitaguchi K., et al. Double-lumen tube location predicts tube malposition and hypoxemia during one-lung ventilation. Br J Anaesth 92 (2004) 195-200
    • (2004) Br J Anaesth , vol.92 , pp. 195-200
    • Inoue, S.1    Nishimine, N.2    Kitaguchi, K.3
  • 12
    • 0038298791 scopus 로고    scopus 로고
    • Bronchial rupture with a left-sided polyvinylchloride double-lumen tube
    • Yüceyar L., Kaynak K., Canturk E., et al. Bronchial rupture with a left-sided polyvinylchloride double-lumen tube. Acta Anaesthesiol Scand 47 (2003) 622-625
    • (2003) Acta Anaesthesiol Scand , vol.47 , pp. 622-625
    • Yüceyar, L.1    Kaynak, K.2    Canturk, E.3
  • 13
    • 0036861981 scopus 로고    scopus 로고
    • Tension pneumothorax during one-lung ventilation: A case report
    • Weng W., DeCrosta D.J., and Zhang H. Tension pneumothorax during one-lung ventilation: A case report. J Clin Anesth 14 (2002) 529-562
    • (2002) J Clin Anesth , vol.14 , pp. 529-562
    • Weng, W.1    DeCrosta, D.J.2    Zhang, H.3
  • 14
    • 31844450002 scopus 로고    scopus 로고
    • Resection of the Arndt bronchial blocker during stapler resection of the left lower lobe
    • Soto R.G., and Oleszak S.P. Resection of the Arndt bronchial blocker during stapler resection of the left lower lobe. J Cardiothorac Vasc Anesth 20 (2006) 131-132
    • (2006) J Cardiothorac Vasc Anesth , vol.20 , pp. 131-132
    • Soto, R.G.1    Oleszak, S.P.2
  • 15
    • 18644376804 scopus 로고    scopus 로고
    • Use of the Arndt wire-guided endobronchial blocker
    • Prabhu M.R., and Smith J.H. Use of the Arndt wire-guided endobronchial blocker. Anesthesiology 97 (2002) 1325-1329
    • (2002) Anesthesiology , vol.97 , pp. 1325-1329
    • Prabhu, M.R.1    Smith, J.H.2
  • 16
    • 19044400049 scopus 로고    scopus 로고
    • Endobronchial blocker dislodgment leading to pulseless electrical activity
    • Sandberg W.S. Endobronchial blocker dislodgment leading to pulseless electrical activity. Anesth Analg 100 (2005) 1728-1731
    • (2005) Anesth Analg , vol.100 , pp. 1728-1731
    • Sandberg, W.S.1
  • 17
    • 56349094334 scopus 로고    scopus 로고
    • A comparison of three designs of bronchial blockers with double-lumen tubes for lung isolation
    • Narayanaswamy M., Lacroix M., Kanellakos G., et al. A comparison of three designs of bronchial blockers with double-lumen tubes for lung isolation. Anesth Analg 104 (2007) SCA11
    • (2007) Anesth Analg , vol.104
    • Narayanaswamy, M.1    Lacroix, M.2    Kanellakos, G.3
  • 18
    • 0031900110 scopus 로고    scopus 로고
    • One-lung ventilation in patients with difficult airways
    • Hagihira S., Takashina M., Mori T., et al. One-lung ventilation in patients with difficult airways. J Cardiothorac Vasc Anesth 12 (1998) 186-192
    • (1998) J Cardiothorac Vasc Anesth , vol.12 , pp. 186-192
    • Hagihira, S.1    Takashina, M.2    Mori, T.3
  • 19
    • 34548090550 scopus 로고    scopus 로고
    • The GlideScope(R) Cobalt videolaryngoscope-A novel single-use device
    • Jones P.M., Harle C.C., and Turkstra T.P. The GlideScope(R) Cobalt videolaryngoscope-A novel single-use device. Can J Anaesth 54 (2007) 677
    • (2007) Can J Anaesth , vol.54 , pp. 677
    • Jones, P.M.1    Harle, C.C.2    Turkstra, T.P.3
  • 20
    • 0025744073 scopus 로고
    • Lung laceration after tracheal extubation over a plastic tube exchanger
    • DeLima L., and Bishop M. Lung laceration after tracheal extubation over a plastic tube exchanger. Anesth Analg 73 (1991) 350-353
    • (1991) Anesth Analg , vol.73 , pp. 350-353
    • DeLima, L.1    Bishop, M.2
  • 21
    • 0035099190 scopus 로고    scopus 로고
    • Variations on one-lung ventilation
    • Tobias J.D. Variations on one-lung ventilation. J Clin Anesth 13 (2001) 35-40
    • (2001) J Clin Anesth , vol.13 , pp. 35-40
    • Tobias, J.D.1
  • 22
    • 0031692435 scopus 로고    scopus 로고
    • New double intrabronchial tube (Naruke tube) for tracheostomized patients
    • Saito T., Naruke T., Carney E., et al. New double intrabronchial tube (Naruke tube) for tracheostomized patients. Anesthesiology 89 (1998) 1038-1041
    • (1998) Anesthesiology , vol.89 , pp. 1038-1041
    • Saito, T.1    Naruke, T.2    Carney, E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.