메뉴 건너뛰기




Volumn 23, Issue 4, 2009, Pages 501-505

A Comparison of the Deflecting-Tip Bronchial Blocker With a Wire-Guided Blocker or Left-Sided Double-Lumen Tube

Author keywords

bronchial blocker; double lumen endotracheal tube; one lung ventilation

Indexed keywords

ADULT; AGED; ARTICLE; BRONCHUS OBSTRUCTION; CLINICAL ARTICLE; CLINICAL TRIAL; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; DEFLECTING TIP ENDOBRONCHIAL BLOCKER; DOUBLE LUMEN ENDOTRACHEAL TUBE; ENDOBRONCHIAL VENTILATION; ENDOTRACHEAL TUBE; EQUIPMENT DESIGN; FEMALE; FIBEROPTIC BRONCHOSCOPY; GUIDE WIRE; HUMAN; LUNG COLLAPSE; LUNG DISEASE; MALE; OUTCOME ASSESSMENT; PRIORITY JOURNAL; RANDOMIZED CONTROLLED TRIAL; WIRE GUIDED ENDOBRONCHIAL BLOCKER;

EID: 67650527330     PISSN: 10530770     EISSN: None     Source Type: Journal    
DOI: 10.1053/j.jvca.2009.02.002     Document Type: Article
Times cited : (29)

References (13)
  • 1
    • 33748205983 scopus 로고    scopus 로고
    • Airway injuries after one-lung ventilation: A comparison between double-lumen tube and endobronchial blocker: A randomized, prospective, controlled trial
    • Knoll H., Ziegeler S., Schreiber J.U., et al. Airway injuries after one-lung ventilation: A comparison between double-lumen tube and endobronchial blocker: A randomized, prospective, controlled trial. Anesthesiology 105 (2006) 471-477
    • (2006) Anesthesiology , vol.105 , pp. 471-477
    • Knoll, H.1    Ziegeler, S.2    Schreiber, J.U.3
  • 2
    • 0029856033 scopus 로고    scopus 로고
    • Comparison of a modified double-lumen endotracheal tube with a single-lumen tube with enclosed bronchial blocker
    • Campos J.H., Reasoner D.K., and Moyers J.R. Comparison of a modified double-lumen endotracheal tube with a single-lumen tube with enclosed bronchial blocker. Anesth Analg 83 (1996) 1268-1272
    • (1996) Anesth Analg , vol.83 , pp. 1268-1272
    • Campos, J.H.1    Reasoner, D.K.2    Moyers, J.R.3
  • 3
    • 0031956767 scopus 로고    scopus 로고
    • Is there a better right-sided tube for one-lung ventilation?. A comparison of the right-sided double-lumen tube with the single-lumen tube with right-sided enclosed bronchial blocker
    • Campos J.H., and Massa F.C. Is there a better right-sided tube for one-lung ventilation?. A comparison of the right-sided double-lumen tube with the single-lumen tube with right-sided enclosed bronchial blocker. Anesth Analg 86 (1998) 696-700
    • (1998) Anesth Analg , vol.86 , pp. 696-700
    • Campos, J.H.1    Massa, F.C.2
  • 4
    • 0346729938 scopus 로고    scopus 로고
    • Lung isolation during port-access cardiac surgery: Double-lumen endotracheal tube versus single-lumen endotracheal tube with a bronchial blocker
    • Grocott H.P., Darrow T.R., Whiteheart D.L., et al. Lung isolation during port-access cardiac surgery: Double-lumen endotracheal tube versus single-lumen endotracheal tube with a bronchial blocker. J Cardiothorac Vasc Anesth 17 (2003) 725-727
    • (2003) J Cardiothorac Vasc Anesth , vol.17 , pp. 725-727
    • Grocott, H.P.1    Darrow, T.R.2    Whiteheart, D.L.3
  • 5
    • 3042767585 scopus 로고    scopus 로고
    • [A comparison of the Arndt endobronchial blocker with a double-lumen tube in robotic cardiac surgery]
    • Lehmann A., Zeitler C., Lang J., et al. [A comparison of the Arndt endobronchial blocker with a double-lumen tube in robotic cardiac surgery]. Anesthesiol Intensivmed Notfallmed Schmerzther 39 (2004) 353-359
    • (2004) Anesthesiol Intensivmed Notfallmed Schmerzther , vol.39 , pp. 353-359
    • Lehmann, A.1    Zeitler, C.2    Lang, J.3
  • 6
    • 0037223284 scopus 로고    scopus 로고
    • A comparison of a left-sided Broncho-Cath with the torque control blocker univent and the wire-guided blocker
    • Campos J.H., and Kernstine K.H. A comparison of a left-sided Broncho-Cath with the torque control blocker univent and the wire-guided blocker. Anesth Analg 96 (2003) 283-289
    • (2003) Anesth Analg , vol.96 , pp. 283-289
    • Campos, J.H.1    Kernstine, K.H.2
  • 7
    • 33644965437 scopus 로고    scopus 로고
    • Devices for lung isolation used by anesthesiologists with limited thoracic experience: Comparison of double-lumen endotracheal tube, Univent torque control blocker, and Arndt wire-guided endobronchial blocker
    • Campos J.H., Hallam E.A., Van Natta T., et al. Devices for lung isolation used by anesthesiologists with limited thoracic experience: Comparison of double-lumen endotracheal tube, Univent torque control blocker, and Arndt wire-guided endobronchial blocker. Anesthesiology 104 (2006) 261-266
    • (2006) Anesthesiology , vol.104 , pp. 261-266
    • Campos, J.H.1    Hallam, E.A.2    Van Natta, T.3
  • 8
    • 0021701206 scopus 로고
    • Difficult tracheal intubation in obstetrics
    • Cormack R.S., and Lehane J. Difficult tracheal intubation in obstetrics. Anaesthesia 39 (1984) 1105-1111
    • (1984) Anaesthesia , vol.39 , pp. 1105-1111
    • Cormack, R.S.1    Lehane, J.2
  • 9
    • 0023449789 scopus 로고
    • Margin of safety in positioning modern double-lumen endotracheal tubes
    • Benumof J.L., Partridge B.L., Salvatierra C., et al. Margin of safety in positioning modern double-lumen endotracheal tubes. Anesthesiology 67 (1987) 729-738
    • (1987) Anesthesiology , vol.67 , pp. 729-738
    • Benumof, J.L.1    Partridge, B.L.2    Salvatierra, C.3
  • 10
    • 33745453384 scopus 로고    scopus 로고
    • Effects of a single-lung recruitment maneuver on the systemic release of inflammatory mediators
    • Puls A., Pollok-Kopp B., Wrigge H., et al. Effects of a single-lung recruitment maneuver on the systemic release of inflammatory mediators. Intensive Care Med 32 (2006) 1080-1085
    • (2006) Intensive Care Med , vol.32 , pp. 1080-1085
    • Puls, A.1    Pollok-Kopp, B.2    Wrigge, H.3
  • 11
    • 0002259631 scopus 로고
    • Double-lumen tube intubation: Separation of the two lungs (double-lumen tube and bronchial blocker intubation)
    • Benumof J.L. (Ed), Saunders, Philadelphia, PA
    • Benumof J.L. Double-lumen tube intubation: Separation of the two lungs (double-lumen tube and bronchial blocker intubation). In: Benumof J.L. (Ed). Anesthesia for Thoracic Surgery (1995), Saunders, Philadelphia, PA 334-335
    • (1995) Anesthesia for Thoracic Surgery , pp. 334-335
    • Benumof, J.L.1
  • 12
    • 0029026967 scopus 로고
    • Double-lumen tube malfunction caused by the carinal hook
    • Pollak Y., Kogan A., and Grunwald Z. Double-lumen tube malfunction caused by the carinal hook. Anesthesiology 83 (1995) 639
    • (1995) Anesthesiology , vol.83 , pp. 639
    • Pollak, Y.1    Kogan, A.2    Grunwald, Z.3
  • 13
    • 0142212423 scopus 로고    scopus 로고
    • An update on bronchial blockers during lung separation techniques in adults
    • Campos J.H. An update on bronchial blockers during lung separation techniques in adults. Anesth Analg 97 (2003) 1266-1274
    • (2003) Anesth Analg , vol.97 , pp. 1266-1274
    • Campos, J.H.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.