메뉴 건너뛰기




Volumn 96, Issue 1, 2003, Pages 283-289

A comparison of a left-sided Broncho-Cath® with the torque control blocker Univent and the wire-guided blocker

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ARTICLE; BRONCHOSCOPE; CLINICAL TRIAL; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; COST; ENDOTRACHEAL TUBE; EXPOSURE; HUMAN; ISOLATION PROCEDURE; LUNG COLLAPSE; MAJOR CLINICAL STUDY; PRIORITY JOURNAL; PROSPECTIVE STUDY; SURGICAL TECHNIQUE; THORAX SURGERY;

EID: 0037223284     PISSN: 00032999     EISSN: None     Source Type: Journal    
DOI: 10.1097/00000539-200301000-00056     Document Type: Article
Times cited : (153)

References (11)
  • 2
    • 0027081047 scopus 로고
    • The utility of a double-lumen tube for one-lung ventilation in a variety of noncardiac thoracic surgical procedures
    • Lewis JW, Serwin JP, Gabriel FS, et al. The utility of a double-lumen tube for one-lung ventilation in a variety of noncardiac thoracic surgical procedures. J Cardiothorac Vasc Anesth 1992; 6:705-10.
    • (1992) J Cardiothorac Vasc Anesth , vol.6 , pp. 705-710
    • Lewis, J.W.1    Serwin, J.P.2    Gabriel, F.S.3
  • 3
    • 0031956767 scopus 로고    scopus 로고
    • Is there a better right-sided tube for one-lung ventilation? A comparison of the right-sided double- lumen tube with the single-lumen tube with right-sided enclosed bronchial blocker
    • Campos JH, Massa CF. Is there a better right-sided tube for one-lung ventilation? A comparison of the right-sided double- lumen tube with the single-lumen tube with right-sided enclosed bronchial blocker. Anesth Analg 1998;86:696-700.
    • (1998) Anesth Analg , vol.86 , pp. 696-700
    • Campos, J.H.1    Massa, C.F.2
  • 4
    • 0032957954 scopus 로고    scopus 로고
    • Single-lung ventilation in a critically ill patient using fiberoptically directed wire-guided endobronchial blocker
    • Arndt GA, Kranner PW, Rusy DA, et al. Single-lung ventilation in a critically ill patient using fiberoptically directed wire-guided endobronchial blocker. Anesthesiology 1999;90:1484-6.
    • (1999) Anesthesiology , vol.90 , pp. 1484-1486
    • Arndt, G.A.1    Kranner, P.W.2    Rusy, D.A.3
  • 5
    • 0032982092 scopus 로고    scopus 로고
    • One lung ventilation when intubation is difficult: Presentation of a new endobronchial blocker
    • Arndt GA, DeLessio ST, Kranner PW, et al. One lung ventilation when intubation is difficult: Presentation of a new endobronchial blocker. Acta Anaesthesiol Scand 1999;43:356-8.
    • (1999) Acta Anaesthesiol Scand , vol.43 , pp. 356-358
    • Arndt, G.A.1    DeLessio, S.T.2    Kranner, P.W.3
  • 6
    • 0033664959 scopus 로고    scopus 로고
    • A new technique for lung isolation in acute thoracic trauma
    • Grocott HP, Scales G, Schinderle D, et al. A new technique for lung isolation in acute thoracic trauma. J Trauma 2000;49:940-2.
    • (2000) J Trauma , vol.49 , pp. 940-942
    • Grocott, H.P.1    Scales, G.2    Schinderle, D.3
  • 7
    • 0029998807 scopus 로고    scopus 로고
    • Tracheal diameter predicts double-lumen tube size: A method for selecting left double-lumen tubes
    • Brodsky JD, Macario A, Mark JBD. Tracheal diameter predicts double-lumen tube size: A method for selecting left double-lumen tubes. Anesth Analg 1996;82:861-4.
    • (1996) Anesth Analg , vol.82 , pp. 861-864
    • Brodsky, J.D.1    Macario, A.2    Mark, J.B.D.3
  • 9
    • 0023449789 scopus 로고
    • Margin of safety in positioning modern double-lumen endotracheal tubes
    • Benumof JL, Partridge BL, Salvatierra C, et al. Margin of safety in positioning modern double-lumen endotracheal tubes. Anesthesiology 1987;67:729-38.
    • (1987) Anesthesiology , vol.67 , pp. 729-738
    • Benumof, J.L.1    Partridge, B.L.2    Salvatierra, C.3
  • 10
    • 0029856033 scopus 로고    scopus 로고
    • Comparison of a modified double-lumen endotracheal tube with a single-lumen tube with enclosed bronchial blocker
    • Campos JH, Reasoner DK, Moyers JR. Comparison of a modified double-lumen endotracheal tube with a single-lumen tube with enclosed bronchial blocker. Anesth Analg 1996;83:1268-72.
    • (1996) Anesth Analg , vol.83 , pp. 1268-1272
    • Campos, J.H.1    Reasoner, D.K.2    Moyers, J.R.3
  • 11
    • 0030843302 scopus 로고    scopus 로고
    • The effects of endobronchial cuff inflation on double-lumen endobronchial tube movement after lateral decubitus positioning
    • Desiderio DP, Burt M, Kolker AC, et al. The effects of endobronchial cuff inflation on double-lumen endobronchial tube movement after lateral decubitus positioning. J Cardiothorac Vasc Anesth 1997;11:595-8.
    • (1997) J Cardiothorac Vasc Anesth , vol.11 , pp. 595-598
    • Desiderio, D.P.1    Burt, M.2    Kolker, A.C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.