메뉴 건너뛰기




Volumn 17, Issue , 2015, Pages e576-e585

Cone-Beam Computed Tomography Evaluation of Horizontal and Vertical Dimensional Changes in Buccal Peri-Implant Alveolar Bone and Soft Tissue: A 1-Year Prospective Clinical Study

Author keywords

Abutment design; Clinical study; Cone beam CT; Implants; Prei implant tissue; Prospective

Indexed keywords

ADULT; AGED; ALVEOLAR BONE; CONE BEAM COMPUTED TOMOGRAPHY; DIAGNOSTIC IMAGING; FEMALE; GINGIVA; HUMAN; MALE; MIDDLE AGED; PROSPECTIVE STUDY; SURGERY; TOOTH IMPLANTATION; VERTICAL DIMENSION OF OCCLUSION; VERY ELDERLY;

EID: 84943153272     PISSN: 15230899     EISSN: 17088208     Source Type: Journal    
DOI: 10.1111/cid.12286     Document Type: Article
Times cited : (44)

References (40)
  • 1
    • 40549106100 scopus 로고    scopus 로고
    • Implant success, survival, and failure: the International Congress of Oral Implantologists (ICOI) Pisa Consensus Conference
    • Misch CE, Perel ML, Wang HL, etal. Implant success, survival, and failure: the International Congress of Oral Implantologists (ICOI) Pisa Consensus Conference. Implant Dent 2008; 17:5-15.
    • (2008) Implant Dent , vol.17 , pp. 5-15
    • Misch, C.E.1    Perel, M.L.2    Wang, H.L.3
  • 2
    • 0022726532 scopus 로고
    • The long-term efficacy of currently used dental implants: a review and proposed criteria of success
    • Albrektsson T, Zarb G, Worthington P, etal. The long-term efficacy of currently used dental implants: a review and proposed criteria of success. Int J Oral Maxillofac Implants 1986; 1:11-25.
    • (1986) Int J Oral Maxillofac Implants , vol.1 , pp. 11-25
    • Albrektsson, T.1    Zarb, G.2    Worthington, P.3
  • 3
    • 33644907242 scopus 로고    scopus 로고
    • Tissue alterations at implant-supported single-tooth replacements: a 1-year prospective clinical study
    • Cardaropoli G, Lekholm U, Wennström JL. Tissue alterations at implant-supported single-tooth replacements: a 1-year prospective clinical study. Clin Oral Implants Res 2006; 17:165-171.
    • (2006) Clin Oral Implants Res , vol.17 , pp. 165-171
    • Cardaropoli, G.1    Lekholm, U.2    Wennström, J.L.3
  • 4
    • 0036199678 scopus 로고    scopus 로고
    • The causes of early implant bone loss: myth or science?
    • Oh TJ, Yoon J, Misch CE, Wang HL. The causes of early implant bone loss: myth or science? J Periodontol 2002; 73:322-333.
    • (2002) J Periodontol , vol.73 , pp. 322-333
    • Oh, T.J.1    Yoon, J.2    Misch, C.E.3    Wang, H.L.4
  • 5
    • 59649130346 scopus 로고    scopus 로고
    • Minimally invasive flapless implant placement: follow-up results from a multicenter study
    • Becker W, Goldstein M, Becker BE, etal. Minimally invasive flapless implant placement: follow-up results from a multicenter study. J Periodontol 2009; 80:347-352.
    • (2009) J Periodontol , vol.80 , pp. 347-352
    • Becker, W.1    Goldstein, M.2    Becker, B.E.3
  • 6
    • 17444417833 scopus 로고    scopus 로고
    • Occlusal considerations in implant therapy: clinical guidelines with biomechanical rationale
    • Kim Y, Oh TJ, Misch CE, Wang HL. Occlusal considerations in implant therapy: clinical guidelines with biomechanical rationale. Clin Oral Implants Res 2005; 16:26-35.
    • (2005) Clin Oral Implants Res , vol.16 , pp. 26-35
    • Kim, Y.1    Oh, T.J.2    Misch, C.E.3    Wang, H.L.4
  • 7
    • 0028382084 scopus 로고
    • Pathogenesis of implant failures
    • Tonetti MS, Schmid J. Pathogenesis of implant failures. Periodontol 2000 1994; 4:127-138.
    • (1994) Periodontol 2000 , vol.4 , pp. 127-138
    • Tonetti, M.S.1    Schmid, J.2
  • 8
    • 54249127386 scopus 로고    scopus 로고
    • Influence of microgap location and configuration on the periimplant bone morphology in submerged implants. An experimental study in dogs
    • Weng D, Nagata MJ. Influence of microgap location and configuration on the periimplant bone morphology in submerged implants. An experimental study in dogs. Clin Oral Implants Res 2008; 19:1141-1147.
    • (2008) Clin Oral Implants Res , vol.19 , pp. 1141-1147
    • Weng, D.1    Nagata, M.J.2
  • 9
    • 0030224033 scopus 로고    scopus 로고
    • The peri-implant hard and soft tissues at different implant systems. A comparative study in the dog
    • Abrahamsson I, Berglundh T, Wennström J, etal. The peri-implant hard and soft tissues at different implant systems. A comparative study in the dog. Clin Oral Implants Res 1996; 7:212-219.
    • (1996) Clin Oral Implants Res , vol.7 , pp. 212-219
    • Abrahamsson, I.1    Berglundh, T.2    Wennström, J.3
  • 10
    • 84857387380 scopus 로고    scopus 로고
    • Infuence of microgap location and configuration on radiographic bone loss around submerged implants: an experimental study in dogs
    • Weng D, Nagata MJH, Bosco AF, etal. Infuence of microgap location and configuration on radiographic bone loss around submerged implants: an experimental study in dogs. Int J Oral Maxillofac Implants 2011; 26:941-946.
    • (2011) Int J Oral Maxillofac Implants , vol.26 , pp. 941-946
    • Weng, D.1    Nagata, M.J.H.2    Bosco, A.F.3
  • 11
    • 84863779380 scopus 로고    scopus 로고
    • Impact of abutment material and dis-/re-connection on soft and hard tissue changes at implants with platform-switching
    • Becker K, Mihatovic I, Golubovic V, etal. Impact of abutment material and dis-/re-connection on soft and hard tissue changes at implants with platform-switching. J Clin Periodontol 2012; 39:774-780.
    • (2012) J Clin Periodontol , vol.39 , pp. 774-780
    • Becker, K.1    Mihatovic, I.2    Golubovic, V.3
  • 12
    • 72949111386 scopus 로고    scopus 로고
    • A prospective, randomized-controlled clinical trial to evaluate bone preservation using implants with different geometry placed into extraction sockets in the maxilla
    • Sanz M, Cecchinato D, Ferrus J, etal. A prospective, randomized-controlled clinical trial to evaluate bone preservation using implants with different geometry placed into extraction sockets in the maxilla. Clin Oral Implants Res 2010; 21:13-21.
    • (2010) Clin Oral Implants Res , vol.21 , pp. 13-21
    • Sanz, M.1    Cecchinato, D.2    Ferrus, J.3
  • 13
    • 57449121595 scopus 로고    scopus 로고
    • Reproducibility of the pink esthetic score-rating soft tissue esthetics around single-implant restorations with regard to dental observer specialization
    • Gehrke P, Lobert M, Dhom G. Reproducibility of the pink esthetic score-rating soft tissue esthetics around single-implant restorations with regard to dental observer specialization. J Esthet Restor Dent 2008; 20:375-384.
    • (2008) J Esthet Restor Dent , vol.20 , pp. 375-384
    • Gehrke, P.1    Lobert, M.2    Dhom, G.3
  • 14
    • 33746358173 scopus 로고    scopus 로고
    • Bone tissue formation adjacent to implants placed in fresh extraction sockets: an experimental study in dogs
    • Botticelli D, Persson LG, Lindhe J, etal. Bone tissue formation adjacent to implants placed in fresh extraction sockets: an experimental study in dogs. Clin Oral Implants Res 2006; 17:351-358.
    • (2006) Clin Oral Implants Res , vol.17 , pp. 351-358
    • Botticelli, D.1    Persson, L.G.2    Lindhe, J.3
  • 15
    • 33750556238 scopus 로고    scopus 로고
    • Radiographic evaluation of marginal bone level around implants with different neck designs after 1 year
    • Shin YK, Han CH, Heo SJ, etal. Radiographic evaluation of marginal bone level around implants with different neck designs after 1 year. Int J Oral Maxillofac Implants 2006; 21:789-794.
    • (2006) Int J Oral Maxillofac Implants , vol.21 , pp. 789-794
    • Shin, Y.K.1    Han, C.H.2    Heo, S.J.3
  • 16
    • 84871930953 scopus 로고    scopus 로고
    • Comparison of cone-beam and conventional multislice computed tomography for image-guided dental implant planning
    • Poeschl PW, Schmidt N, Guevara-Rojas G, etal. Comparison of cone-beam and conventional multislice computed tomography for image-guided dental implant planning. Clin Oral Investig 2013; 17:317-324.
    • (2013) Clin Oral Investig , vol.17 , pp. 317-324
    • Poeschl, P.W.1    Schmidt, N.2    Guevara-Rojas, G.3
  • 17
    • 78751532284 scopus 로고    scopus 로고
    • A comparative study of the accuracy and reliability of multidetector computed tomography and cone beam computed tomography in the assessment of dental implant site dimensions
    • Al-Ekrish AA, Ekram M. A comparative study of the accuracy and reliability of multidetector computed tomography and cone beam computed tomography in the assessment of dental implant site dimensions. Dentomaxillofac Radiol 2011; 40:67-75.
    • (2011) Dentomaxillofac Radiol , vol.40 , pp. 67-75
    • Al-Ekrish, A.A.1    Ekram, M.2
  • 18
    • 33644639722 scopus 로고    scopus 로고
    • Clinical applications of cone-beam computed tomography in dental practice
    • Scarfe WC, Farman AG, Sukovic P. Clinical applications of cone-beam computed tomography in dental practice. J Can Dent Assoc 2006; 72:75-80.
    • (2006) J Can Dent Assoc , vol.72 , pp. 75-80
    • Scarfe, W.C.1    Farman, A.G.2    Sukovic, P.3
  • 19
    • 0642365211 scopus 로고    scopus 로고
    • Cone beam computed tomography in craniofacial imaging
    • Sukovic P. Cone beam computed tomography in craniofacial imaging. Orthod Craniofac Res 2003; 6(Suppl 1):31-36.
    • (2003) Orthod Craniofac Res , vol.6 , pp. 31-36
    • Sukovic, P.1
  • 20
    • 84891626250 scopus 로고    scopus 로고
    • Cone beam computed tomography for imaging orbital trauma-image quality and radiation dose compared with conventional multislice computed tomography
    • Brisco J, Fuller K, Lee N, etal. Cone beam computed tomography for imaging orbital trauma-image quality and radiation dose compared with conventional multislice computed tomography. Br J Oral Maxillofac Surg 2014; 52:76-80.
    • (2014) Br J Oral Maxillofac Surg , vol.52 , pp. 76-80
    • Brisco, J.1    Fuller, K.2    Lee, N.3
  • 21
    • 66649116309 scopus 로고    scopus 로고
    • A prospective multicenter 5-year radiographic evaluation of crestal bone levels over time in 596 dental implants placed in 192 patients
    • Cochran DL, Nummikoski PV, Schoolfield JD, etal. A prospective multicenter 5-year radiographic evaluation of crestal bone levels over time in 596 dental implants placed in 192 patients. J Periodontol 2009; 80:725-733.
    • (2009) J Periodontol , vol.80 , pp. 725-733
    • Cochran, D.L.1    Nummikoski, P.V.2    Schoolfield, J.D.3
  • 22
    • 0034782965 scopus 로고    scopus 로고
    • Influence of the size of the microgap on crestal bone changes around titanium implants. A histometric evaluation of unloaded non-submerged implants in the canine mandible
    • Hermann JS, Schoolfield JD, Schenk RK, etal. Influence of the size of the microgap on crestal bone changes around titanium implants. A histometric evaluation of unloaded non-submerged implants in the canine mandible. J Periodontol 2001; 72:1372-1383.
    • (2001) J Periodontol , vol.72 , pp. 1372-1383
    • Hermann, J.S.1    Schoolfield, J.D.2    Schenk, R.K.3
  • 23
    • 30844432439 scopus 로고    scopus 로고
    • In vitro evaluation of bacterial leakage along the implant-abutment interface of different implant systems
    • Steinebrunner L, Wolfart S, Bössmann K, etal. In vitro evaluation of bacterial leakage along the implant-abutment interface of different implant systems. Int J Oral Maxillofac Implants 2005; 20:875-881.
    • (2005) Int J Oral Maxillofac Implants , vol.20 , pp. 875-881
    • Steinebrunner, L.1    Wolfart, S.2    Bössmann, K.3
  • 24
    • 72749083648 scopus 로고    scopus 로고
    • Bacterial colonization of the dental implant fixture-abutment interface: an in vitro study
    • Tesmer M, Wallet S, Koutouzis T, etal. Bacterial colonization of the dental implant fixture-abutment interface: an in vitro study. J Periodontol 2009; 80:1991-1997.
    • (2009) J Periodontol , vol.80 , pp. 1991-1997
    • Tesmer, M.1    Wallet, S.2    Koutouzis, T.3
  • 25
    • 69949169325 scopus 로고    scopus 로고
    • Comparison between effective radiation dose of CBCT and MSCT scanners for dentomaxillofacial applications
    • Loubele M, Bogaerts R, Van Dijck E, etal. Comparison between effective radiation dose of CBCT and MSCT scanners for dentomaxillofacial applications. Eur J Radiol 2009; 71:461-468.
    • (2009) Eur J Radiol , vol.71 , pp. 461-468
    • Loubele, M.1    Bogaerts, R.2    Van Dijck, E.3
  • 26
    • 33645731806 scopus 로고    scopus 로고
    • Cone-beam computed tomography in orthodontics: benefits and limitations
    • Holberg C, Steinhäuser S, Geis P, etal. Cone-beam computed tomography in orthodontics: benefits and limitations. J Orofac Orthop 2005; 66:434-444.
    • (2005) J Orofac Orthop , vol.66 , pp. 434-444
    • Holberg, C.1    Steinhäuser, S.2    Geis, P.3
  • 27
    • 77955884679 scopus 로고    scopus 로고
    • Multichannel computed tomography versus cone-beam computed tomography: linear accuracy of in vitro measurements of the maxilla for implant placement
    • Fatemitabar SA, Nikgoo A. Multichannel computed tomography versus cone-beam computed tomography: linear accuracy of in vitro measurements of the maxilla for implant placement. Int J Oral Maxillofac Implants 2010; 25:499-505.
    • (2010) Int J Oral Maxillofac Implants , vol.25 , pp. 499-505
    • Fatemitabar, S.A.1    Nikgoo, A.2
  • 28
    • 84862829660 scopus 로고    scopus 로고
    • Use of cone beam computed tomography in implant dentistry: the International Congress of Oral Implantologists consensus report
    • Benavides E, Rios HF, Ganz SD, etal. Use of cone beam computed tomography in implant dentistry: the International Congress of Oral Implantologists consensus report. Implant Dent 2012; 21:78-86.
    • (2012) Implant Dent , vol.21 , pp. 78-86
    • Benavides, E.1    Rios, H.F.2    Ganz, S.D.3
  • 29
    • 78049310276 scopus 로고    scopus 로고
    • A comparison of cone-beam computed tomography and direct measurement in the examination of the mandibular canal and adjacent structures
    • Kim TS, Caruso JM, Christensen H, etal. A comparison of cone-beam computed tomography and direct measurement in the examination of the mandibular canal and adjacent structures. J Endod 2010; 36:1191-1194.
    • (2010) J Endod , vol.36 , pp. 1191-1194
    • Kim, T.S.1    Caruso, J.M.2    Christensen, H.3
  • 30
    • 77954670876 scopus 로고    scopus 로고
    • Intraexaminer and interexaminer reliabilities of landmark identification on digitized lateral cephalograms and formatted 3-dimensional cone-beam computerized tomography images
    • Lagravère MO, Low C, Flores-Mir C, etal. Intraexaminer and interexaminer reliabilities of landmark identification on digitized lateral cephalograms and formatted 3-dimensional cone-beam computerized tomography images. Am J Orthod Dentofacial Orthop 2010; 137:598-604.
    • (2010) Am J Orthod Dentofacial Orthop , vol.137 , pp. 598-604
    • Lagravère, M.O.1    Low, C.2    Flores-Mir, C.3
  • 31
    • 31944431959 scopus 로고    scopus 로고
    • Platform switching: a new concept in implant dentistry for controlling postrestorative crestal bone levels
    • Lazzara RJ, Porter SS. Platform switching: a new concept in implant dentistry for controlling postrestorative crestal bone levels. Int J Periodontics Restorative Dent 2006; 26:9-17.
    • (2006) Int J Periodontics Restorative Dent , vol.26 , pp. 9-17
    • Lazzara, R.J.1    Porter, S.S.2
  • 33
    • 85028102717 scopus 로고    scopus 로고
    • Influences of implant neck design and implant-abutment joint type on peri-implant bone stress and abutment micromovement: three-dimensional finite element analysis
    • Yamanishi Y, Yamaguchi S, Imazato S, etal. Influences of implant neck design and implant-abutment joint type on peri-implant bone stress and abutment micromovement: three-dimensional finite element analysis. Dent Mater 2012; 28:1126-1133.
    • (2012) Dent Mater , vol.28 , pp. 1126-1133
    • Yamanishi, Y.1    Yamaguchi, S.2    Imazato, S.3
  • 34
    • 77953256774 scopus 로고    scopus 로고
    • Biomechanical effect of platform switching in implant dentistry: a three-dimensional finite element analysis
    • Chang CL, Chen CS, Hsu ML. Biomechanical effect of platform switching in implant dentistry: a three-dimensional finite element analysis. Int J Oral Maxillofac Implants 2010; 25:295-304.
    • (2010) Int J Oral Maxillofac Implants , vol.25 , pp. 295-304
    • Chang, C.L.1    Chen, C.S.2    Hsu, M.L.3
  • 36
    • 73349106551 scopus 로고    scopus 로고
    • The influence of soft tissue thickness on crestal bone changes around implants: a 1-year prospective controlled clinical trial
    • Linkevicius T, Apse P, Grybauskas S, etal. The influence of soft tissue thickness on crestal bone changes around implants: a 1-year prospective controlled clinical trial. Int J Oral Maxillofac Implants 2009; 24:712-719.
    • (2009) Int J Oral Maxillofac Implants , vol.24 , pp. 712-719
    • Linkevicius, T.1    Apse, P.2    Grybauskas, S.3
  • 37
    • 0027685784 scopus 로고
    • Probing depth at implants and teeth. An experimental study in the dog
    • Ericsson I, Lindhe J. Probing depth at implants and teeth. An experimental study in the dog. J Clin Periodontol 1993; 20:623-627.
    • (1993) J Clin Periodontol , vol.20 , pp. 623-627
    • Ericsson, I.1    Lindhe, J.2
  • 38
    • 0033209843 scopus 로고    scopus 로고
    • The barrier between the keratinized mucosa and the dental implant. An experimental study in the dog
    • Moon IS, Berglundh T, Abrahamsson I, etal. The barrier between the keratinized mucosa and the dental implant. An experimental study in the dog. J Clin Periodontol 1999; 26:658-663.
    • (1999) J Clin Periodontol , vol.26 , pp. 658-663
    • Moon, I.S.1    Berglundh, T.2    Abrahamsson, I.3
  • 39
    • 0026834460 scopus 로고
    • Experimental breakdown of peri-implant and periodontal tissues. A study in the beagle dog
    • Lindhe J, Berglundh T, Ericsson I, etal. Experimental breakdown of peri-implant and periodontal tissues. A study in the beagle dog. Clin Oral Implants Res 1992; 3:9-16.
    • (1992) Clin Oral Implants Res , vol.3 , pp. 9-16
    • Lindhe, J.1    Berglundh, T.2    Ericsson, I.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.