메뉴 건너뛰기




Volumn 19, Issue 4, 2015, Pages 867-882

Comparison of continuous-flow and static-chamber μPCR devices through a computational study: the potential of flexible polymeric substrates

Author keywords

Continuous flow; DNA amplification; Flexible substrates; Modeling; PCR; Simulation; Static chamber

Indexed keywords

BIOINFORMATICS; CONSERVATION; DNA; ENERGY DISSIPATION; ENERGY UTILIZATION; FLEXIBLE ELECTRONICS; HEAT TRANSFER; HEATING EQUIPMENT; LAMINAR FLOW; MICROELECTROMECHANICAL DEVICES; MODELS; PRINTED CIRCUITS; SUBSTRATES; THERMAL CYCLING;

EID: 84942981682     PISSN: 16134982     EISSN: 16134990     Source Type: Journal    
DOI: 10.1007/s10404-015-1613-1     Document Type: Article
Times cited : (18)

References (42)
  • 1
    • 84862491918 scopus 로고    scopus 로고
    • Miniaturized nucleic acid amplification systems for rapid and point-of-care diagnostics: a review
    • Ahmad F, Hashsham SA (2012) Miniaturized nucleic acid amplification systems for rapid and point-of-care diagnostics: a review. Anal Chim Acta 733:1–15
    • (2012) Anal Chim Acta , vol.733 , pp. 1-15
    • Ahmad, F.1    Hashsham, S.A.2
  • 2
    • 58249087758 scopus 로고    scopus 로고
    • Coupled flow and reaction during natural convection PCR
    • Allen J, Kenward M, Dorfman K (2009) Coupled flow and reaction during natural convection PCR. Microfluid Nanofluid 6:121–130
    • (2009) Microfluid Nanofluid , vol.6 , pp. 121-130
    • Allen, J.1    Kenward, M.2    Dorfman, K.3
  • 3
    • 84874682803 scopus 로고    scopus 로고
    • Experimental validation of numerical study on thermoelectric-based heating in an integrated centrifugal microfluidic platform for polymerase chain reaction amplification
    • Amasia M, Kang S-W, Banerjee D, Madou M (2013) Experimental validation of numerical study on thermoelectric-based heating in an integrated centrifugal microfluidic platform for polymerase chain reaction amplification. Biomicrofluidics 7:014106
    • (2013) Biomicrofluidics , vol.7 , pp. 014106
    • Amasia, M.1    Kang, S.-W.2    Banerjee, D.3    Madou, M.4
  • 4
    • 6344289597 scopus 로고    scopus 로고
    • Coupled multiphysics and chemistry simulations of PCR microreactors with active control
    • Nanotech, South Carolin
    • Athavale M, Chen Z, Furmanczyk M, Przekwas A (2001) Coupled multiphysics and chemistry simulations of PCR microreactors with active control. In: Nanotech (ed) Modeling and simulation of microsystems. Nanotech, South Carolina, pp 574–577
    • (2001) Modeling and simulation of microsystems , pp. 574-577
    • Athavale, M.1    Chen, Z.2    Furmanczyk, M.3    Przekwas, A.4
  • 6
    • 84868021863 scopus 로고    scopus 로고
    • Fast nucleic acid amplification for integration in point-of-care applications
    • Brunklaus S et al (2012) Fast nucleic acid amplification for integration in point-of-care applications. Electrophoresis 33:3222–3228
    • (2012) Electrophoresis , vol.33 , pp. 3222-3228
    • Brunklaus, S.1
  • 7
    • 79551646467 scopus 로고    scopus 로고
    • Plastic microfluidic chip for continuous-flow polymerase chain reaction: simulations and experiments
    • Cao Q, Kim M-C, Klapperich C (2011) Plastic microfluidic chip for continuous-flow polymerase chain reaction: simulations and experiments. Biotechnol J 6:177–184
    • (2011) Biotechnol J , vol.6 , pp. 177-184
    • Cao, Q.1    Kim, M.-C.2    Klapperich, C.3
  • 9
    • 77955466723 scopus 로고    scopus 로고
    • Titer-plate formatted continuous flow thermal reactors: design and performance of a nanoliter reactor
    • Chen PC et al (2010) Titer-plate formatted continuous flow thermal reactors: design and performance of a nanoliter reactor. Sens Actuators, B Chem 149:291–300
    • (2010) Sens Actuators, B Chem , vol.149 , pp. 291-300
    • Chen, P.C.1
  • 10
    • 84860490359 scopus 로고    scopus 로고
    • Simulation guided-design of a microfluidic thermal reactor for polymerase chain reaction
    • Chen P-C, Fan W, Hoo T-K, Chan LCZ, Wang Z (2012) Simulation guided-design of a microfluidic thermal reactor for polymerase chain reaction. Chem Eng Res Des 90:591–599
    • (2012) Chem Eng Res Des , vol.90 , pp. 591-599
    • Chen, P.-C.1    Fan, W.2    Hoo, T.-K.3    Chan, L.C.Z.4    Wang, Z.5
  • 11
    • 0036643648 scopus 로고    scopus 로고
    • A miniaturized cyclic PCR device—modeling and experiments
    • Chou CF et al (2002) A miniaturized cyclic PCR device—modeling and experiments. Microelectron Eng 61–62:921–925
    • (2002) Microelectron Eng , vol.61-62 , pp. 921-925
    • Chou, C.F.1
  • 13
    • 84857191601 scopus 로고    scopus 로고
    • Robust optimization-based multi-loop PID controller tuning: a new tool and its industrial application
    • Dittmar R, Gill S, Singh H, Darby M (2012) Robust optimization-based multi-loop PID controller tuning: a new tool and its industrial application. Control Eng Prac 20:355–370
    • (2012) Control Eng Prac , vol.20 , pp. 355-370
    • Dittmar, R.1    Gill, S.2    Singh, H.3    Darby, M.4
  • 16
    • 84942997228 scopus 로고    scopus 로고
    • Hunicke-Smith SP (1997) PCR and cycle sequencing reactions: a new device and engineering model (Ph.D. Thesis). Stanford University
    • Hunicke-Smith SP (1997) PCR and cycle sequencing reactions: a new device and engineering model (Ph.D. Thesis). Stanford University
  • 17
    • 84899007298 scopus 로고    scopus 로고
    • Three-dimensional transient thermal analysis for a silicon PCR Microreactor
    • Ibrahim O, Jones B, Hassab M, Op de Beeck M (2014) Three-dimensional transient thermal analysis for a silicon PCR Microreactor. Numer Heat Tr A—Appl 65:1069–1088
    • (2014) Numer Heat Tr A—Appl , vol.65 , pp. 1069-1088
    • Ibrahim, O.1    Jones, B.2    Hassab, M.3    Op de Beeck, M.4
  • 18
    • 84894317137 scopus 로고    scopus 로고
    • A one-step tuning method for PID controllers with robustness specification using plant step-response data
    • Jeng JC, Tseng WL, Chiu MS (2014) A one-step tuning method for PID controllers with robustness specification using plant step-response data. Chem Eng Res Des 92:545–558
    • (2014) Chem Eng Res Des , vol.92 , pp. 545-558
    • Jeng, J.C.1    Tseng, W.L.2    Chiu, M.S.3
  • 19
    • 33845221285 scopus 로고    scopus 로고
    • Simulation and optimization of a flow-through micro PCR chip
    • Boston, Massachusett
    • Kang J, Chen C, Smolinski J, Thomas R, Tucker J, Auner G (2006) Simulation and optimization of a flow-through micro PCR chip. In: Nanotech (ed) NSTI Nanotech. Nanotech, Boston, Massachusetts, pp 585–588
    • (2006) Nanotech , pp. 585-588
    • Kang, J.1    Chen, C.2    Smolinski, J.3    Thomas, R.4    Tucker, J.5    Auner, G.6    NSTI, N.N.7
  • 20
    • 0032524099 scopus 로고    scopus 로고
    • Chemical amplification: continuous-Flow PCR on a chip
    • Kopp MU, Mello AJd, Manz A (1998) Chemical amplification: continuous-Flow PCR on a chip. Science 280:1046–1048
    • (1998) Science , vol.280 , pp. 1046-1048
    • Kopp, M.U.1    Mello, A.J.2    Manz, A.3
  • 21
    • 0037174631 scopus 로고    scopus 로고
    • PCR in a Rayleigh–Bénard convection cell
    • Krishnan M, Ugaz VM, Burns MA (2002) PCR in a Rayleigh–Bénard convection cell. Science 298:793
    • (2002) Science , vol.298 , pp. 793
    • Krishnan, M.1    Ugaz, V.M.2    Burns, M.A.3
  • 23
    • 84868251780 scopus 로고    scopus 로고
    • Kinetic parameters estimation in the polymerase chain reaction process using the genetic algorithm
    • Li L, Wang C, Song B, Mi L, Hu J (2012) Kinetic parameters estimation in the polymerase chain reaction process using the genetic algorithm. Ind Eng Chem Res 51:13268–13273
    • (2012) Ind Eng Chem Res , vol.51 , pp. 13268-13273
    • Li, L.1    Wang, C.2    Song, B.3    Mi, L.4    Hu, J.5
  • 24
    • 0036079139 scopus 로고    scopus 로고
    • A nanoliter rotary device for polymerase chain reaction
    • Liu J, Enzelberger M, Quake S (2002) A nanoliter rotary device for polymerase chain reaction. Electrophoresis 23:1531–1536
    • (2002) Electrophoresis , vol.23 , pp. 1531-1536
    • Liu, J.1    Enzelberger, M.2    Quake, S.3
  • 25
    • 84858335260 scopus 로고    scopus 로고
    • Nested PCR in magnetically actuated circular closed-loop PCR microchip system
    • Lok KS, Lee PPF, Kwok YC, Nguyen NT (2012) Nested PCR in magnetically actuated circular closed-loop PCR microchip system. Microchim Acta 177:111–117
    • (2012) Microchim Acta , vol.177 , pp. 111-117
    • Lok, K.S.1    Lee, P.P.F.2    Kwok, Y.C.3    Nguyen, N.T.4
  • 26
    • 25144439528 scopus 로고    scopus 로고
    • A kinetic model of quantitative real-time polymerase chain reaction
    • Mehra S, Hu W-S (2005) A kinetic model of quantitative real-time polymerase chain reaction. Biotechnol Bioeng 91:848–860
    • (2005) Biotechnol Bioeng , vol.91 , pp. 848-860
    • Mehra, S.1    Hu, W.-S.2
  • 27
    • 84942982431 scopus 로고    scopus 로고
    • Modelling of serpentine continuous flow polymerase chain reaction microfluidics
    • Mohammed A, Adeniyi AA, Hassan AB (2012) Modelling of serpentine continuous flow polymerase chain reaction microfluidics. IJEST 4:1183–1189
    • (2012) IJEST , vol.4 , pp. 1183-1189
    • Mohammed, A.1    Adeniyi, A.A.2    Hassan, A.B.3
  • 28
    • 34447344443 scopus 로고    scopus 로고
    • Numerical and experimental study of a droplet-based PCR chip
    • Mohr S et al (2007) Numerical and experimental study of a droplet-based PCR chip. Microfluid Nanofluid 3:611–621
    • (2007) Microfluid Nanofluid , vol.3 , pp. 611-621
    • Mohr, S.1
  • 31
    • 0141426476 scopus 로고    scopus 로고
    • Continuous-flow DNA and RNA amplification chip combined with laser-induced fluorescence detection
    • Obeid PJ, Christopoulos TK (2003) Continuous-flow DNA and RNA amplification chip combined with laser-induced fluorescence detection. Anal Chim Acta 494:1–9
    • (2003) Anal Chim Acta , vol.494 , pp. 1-9
    • Obeid, P.J.1    Christopoulos, T.K.2
  • 32
    • 84900025846 scopus 로고    scopus 로고
    • A passive micromixer for enzymatic digestion of DNA
    • Papadopoulos VE et al (2014) A passive micromixer for enzymatic digestion of DNA. Microelectron Eng 124:42–46
    • (2014) Microelectron Eng , vol.124 , pp. 42-46
    • Papadopoulos, V.E.1
  • 33
    • 77951992184 scopus 로고    scopus 로고
    • Titer plate formatted continuous flow thermal reactors for high throughput applications: fabrication and testing
    • Park DSW et al (2010) Titer plate formatted continuous flow thermal reactors for high throughput applications: fabrication and testing. J Micromech Microeng 20:055003
    • (2010) J Micromech Microeng , vol.20
    • Park, D.S.W.1
  • 35
    • 84887699370 scopus 로고    scopus 로고
    • Microscale chaotic advection enables robust convective DNA replication
    • Priye A, Hassan YA, Ugaz VM (2013) Microscale chaotic advection enables robust convective DNA replication. Anal Chem 85:10536–10541
    • (2013) Anal Chem , vol.85 , pp. 10536-10541
    • Priye, A.1    Hassan, Y.A.2    Ugaz, V.M.3
  • 36
    • 14744284141 scopus 로고    scopus 로고
    • A microchip-based PCR device using flexible printed circuit technology
    • Shen K, Chen X, Guo M, Cheng J (2005) A microchip-based PCR device using flexible printed circuit technology. Sensor Actuat B—Chem 105:251–258
    • (2005) Sensor Actuat B—Chem , vol.105 , pp. 251-258
    • Shen, K.1    Chen, X.2    Guo, M.3    Cheng, J.4
  • 37
    • 34547133960 scopus 로고    scopus 로고
    • A circular ferrofluid driven microchip for rapid polymerase chain reaction
    • Sun Y, Kwok YC, Nguyen NT (2007) A circular ferrofluid driven microchip for rapid polymerase chain reaction. Lab Chip 7:1012–1017
    • (2007) Lab Chip , vol.7 , pp. 1012-1017
    • Sun, Y.1    Kwok, Y.C.2    Nguyen, N.T.3
  • 38
    • 84912074823 scopus 로고    scopus 로고
    • Thermal gradient continuous-flow PCR: a guide to design
    • Thomas S, Orozco R, Ameel T (2014) Thermal gradient continuous-flow PCR: a guide to design. Microfluid Nanofluid 17:1039–1051
    • (2014) Microfluid Nanofluid , vol.17 , pp. 1039-1051
    • Thomas, S.1    Orozco, R.2    Ameel, T.3
  • 39
    • 77955442141 scopus 로고    scopus 로고
    • Kinetic characteristics of continuous flow polymerase chain reaction chip: a numerical investigation
    • Wang S, Wang W (2010) Kinetic characteristics of continuous flow polymerase chain reaction chip: a numerical investigation. Sci China Technol Sci 53:1967–1972
    • (2010) Sci China Technol Sci , vol.53 , pp. 1967-1972
    • Wang, S.1    Wang, W.2
  • 41
    • 34547981243 scopus 로고    scopus 로고
    • Multi-physics simulational analysis of a novel PCR micro-device
    • Wang Y, Pant K, Grover J, Sundaram S (2007) Multi-physics simulational analysis of a novel PCR micro-device. Nanotech 3:456–459
    • (2007) Nanotech , vol.3 , pp. 456-459
    • Wang, Y.1    Pant, K.2    Grover, J.3    Sundaram, S.4
  • 42
    • 62649132171 scopus 로고    scopus 로고
    • Microfluidic DNA amplification—a review
    • Zhang Y, Ozdemir P (2009) Microfluidic DNA amplification—a review. Anal Chim Acta 638:115–125
    • (2009) Anal Chim Acta , vol.638 , pp. 115-125
    • Zhang, Y.1    Ozdemir, P.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.