메뉴 건너뛰기




Volumn 7, Issue 3, 2015, Pages 213-221

Cortical Bone Trajectory for Lumbar Pedicle Screw Placement: A Review of Published Reports

Author keywords

Cortical bone trajectory; Cortical screw; Medio lateral superior trajectory; Pedicle fixation; Pedicle screw

Indexed keywords

BIOMECHANICS; DEVICES; EVIDENCE BASED MEDICINE; HUMAN; LUMBAR VERTEBRA; MATERIALS TESTING; MINIMALLY INVASIVE SURGERY; PEDICLE SCREW; PHYSIOLOGY; PROCEDURES; SPINE FUSION; SURGERY;

EID: 84942105402     PISSN: 17577853     EISSN: None     Source Type: Journal    
DOI: 10.1111/os.12185     Document Type: Review
Times cited : (69)

References (39)
  • 1
    • 0022551914 scopus 로고
    • Plating of thoracic, thoracolumbar, and lumbar injuries with pedicle screw plates
    • Roy-Camille R, Saillant G, Mazel C. Plating of thoracic, thoracolumbar, and lumbar injuries with pedicle screw plates. Orthop Clin North Am, 1986, 17: 147-159.
    • (1986) Orthop Clin North Am , vol.17 , pp. 147-159
    • Roy-Camille, R.1    Saillant, G.2    Mazel, C.3
  • 2
    • 0028567083 scopus 로고
    • Comparison of Cotrel-Dubousset pedicle screws and hooks in the treatment of idiopathic scoliosis
    • Suk SI, Lee CK, Min HJ, Cho KH, Oh JH. Comparison of Cotrel-Dubousset pedicle screws and hooks in the treatment of idiopathic scoliosis. Int Orthop, 1994, 18: 341-346.
    • (1994) Int Orthop , vol.18 , pp. 341-346
    • Suk, S.I.1    Lee, C.K.2    Min, H.J.3    Cho, K.H.4    Oh, J.H.5
  • 3
    • 33644877786 scopus 로고    scopus 로고
    • Pedicle screw placement in the thoracic spine: a comparison of image-guided and manual techniques in cadavers
    • Hart RA, Hansen BL, Shea M, Hsu F, Anderson GJ. Pedicle screw placement in the thoracic spine: a comparison of image-guided and manual techniques in cadavers. Spine (Phila Pa 1976), 2005, 30: E326-E331.
    • (2005) Spine (Phila Pa 1976) , vol.30 , pp. E326-E331
    • Hart, R.A.1    Hansen, B.L.2    Shea, M.3    Hsu, F.4    Anderson, G.J.5
  • 4
    • 79955603027 scopus 로고    scopus 로고
    • Pedicle screw insertion angle and pullout strength: comparison of 2 proposed strategies
    • Inceoğlu S, Montgomery WH Jr, St Clair S, McLain RF. Pedicle screw insertion angle and pullout strength: comparison of 2 proposed strategies. J Neurosurg Spine, 2011, 14: 670-676.
    • (2011) J Neurosurg Spine , vol.14 , pp. 670-676
    • Inceoğlu, S.1    Montgomery, W.H.2    St Clair, S.3    McLain, R.F.4
  • 5
    • 84896723365 scopus 로고    scopus 로고
    • In vivo analysis of insertional torque during pedicle screwing using cortical bone trajectory technique
    • Matsukawa K, Yato Y, Kato T, Imabayashi H, Asazuma T, Nemoto K. In vivo analysis of insertional torque during pedicle screwing using cortical bone trajectory technique. Spine (Phila Pa 1976), 2014, 39: E240-E245.
    • (2014) Spine (Phila Pa 1976) , vol.39 , pp. E240-E245
    • Matsukawa, K.1    Yato, Y.2    Kato, T.3    Imabayashi, H.4    Asazuma, T.5    Nemoto, K.6
  • 6
    • 0023790873 scopus 로고
    • Spinal pedicle fixation: reliability and validity of roentgenogram-based assessment and surgical factors on successful screw placement
    • Weinstein JN, Spratt KF, Spengler D, Brick C, Reid S. Spinal pedicle fixation: reliability and validity of roentgenogram-based assessment and surgical factors on successful screw placement. Spine (Phila Pa 1976), 1988, 13: 1012-1018.
    • (1988) Spine (Phila Pa 1976) , vol.13 , pp. 1012-1018
    • Weinstein, J.N.1    Spratt, K.F.2    Spengler, D.3    Brick, C.4    Reid, S.5
  • 7
    • 0033834616 scopus 로고    scopus 로고
    • Accuracy of pedicle screw insertion with and without computer assistance: a randomised controlled clinical study in 100 consecutive patients
    • Laine T, Lund T, Ylikoski M, Lohikoski J, Schlenzka D. Accuracy of pedicle screw insertion with and without computer assistance: a randomised controlled clinical study in 100 consecutive patients. Eur Spine J, 2000, 9: 235-240.
    • (2000) Eur Spine J , vol.9 , pp. 235-240
    • Laine, T.1    Lund, T.2    Ylikoski, M.3    Lohikoski, J.4    Schlenzka, D.5
  • 8
  • 10
    • 79955916080 scopus 로고    scopus 로고
    • Technique, challenges and indications for percutaneous pedicle screw fixation
    • Mobbs RJ, Sivabalan P, Li J. Technique, challenges and indications for percutaneous pedicle screw fixation. J Clin Neurosci, 2011, 18: 741-749.
    • (2011) J Clin Neurosci , vol.18 , pp. 741-749
    • Mobbs, R.J.1    Sivabalan, P.2    Li, J.3
  • 11
    • 84937968891 scopus 로고    scopus 로고
    • Indirect foraminal decompression following anterior lumbar interbody fusion (ALIF): a prospective radiographic study using a new pedicle to pedicle (P-P) technique
    • Rao PJ, Maharaj MM, Phan K, Lakshan Abeygunasekara M, Mobbs RJ. Indirect foraminal decompression following anterior lumbar interbody fusion (ALIF): a prospective radiographic study using a new pedicle to pedicle (P-P) technique. Spine J, 2015, 15: 817-824.
    • (2015) Spine J , vol.15 , pp. 817-824
    • Rao, P.J.1    Maharaj, M.M.2    Phan, K.3    Lakshan Abeygunasekara, M.4    Mobbs, R.J.5
  • 12
    • 85042452512 scopus 로고    scopus 로고
    • Cortical bone trajectory for thoracic pedicle screws: a technical note
    • Jul 29. [Epub ahead of print]
    • Matsukawa K, Yato Y, Hynes RA, etal. Cortical bone trajectory for thoracic pedicle screws: a technical note. J Spinal Disord Tech, 2014 Jul 29. [Epub ahead of print]
    • (2014) J Spinal Disord Tech
    • Matsukawa, K.1    Yato, Y.2    Hynes, R.A.3
  • 13
    • 84930572817 scopus 로고    scopus 로고
    • Comparison of navigated versus non-navigated pedicle screw placement in 260 patients and 1434 screws: screw accuracy, screw size, and the complexity of surgery
    • Luther N, Iorgulescu JB, Geannette C, etal. Comparison of navigated versus non-navigated pedicle screw placement in 260 patients and 1434 screws: screw accuracy, screw size, and the complexity of surgery. J Spinal Disord Tech, 2015, 28: E298-E303.
    • (2015) J Spinal Disord Tech , vol.28 , pp. E298-E303
    • Luther, N.1    Iorgulescu, J.B.2    Geannette, C.3
  • 14
    • 64849089881 scopus 로고    scopus 로고
    • Cortical bone trajectory for lumbar pedicle screws
    • Santoni BG, Hynes RA, McGilvray KC, etal. Cortical bone trajectory for lumbar pedicle screws. Spine J, 2009, 9: 366-373.
    • (2009) Spine J , vol.9 , pp. 366-373
    • Santoni, B.G.1    Hynes, R.A.2    McGilvray, K.C.3
  • 15
    • 84881477180 scopus 로고    scopus 로고
    • Morphometric measurement of cortical bone trajectory for lumbar pedicle screw insertion using computed tomography
    • Matsukawa K, Yato Y, Nemoto O, Imabayashi H, Asazuma T, Nemoto K. Morphometric measurement of cortical bone trajectory for lumbar pedicle screw insertion using computed tomography. J Spinal Disord Tech, 2013, 26: E248-E253.
    • (2013) J Spinal Disord Tech , vol.26 , pp. E248-E253
    • Matsukawa, K.1    Yato, Y.2    Nemoto, O.3    Imabayashi, H.4    Asazuma, T.5    Nemoto, K.6
  • 16
    • 84927169903 scopus 로고    scopus 로고
    • Cortical screws used to rescue failed lumbar pedicle screw construct: a biomechanical analysis
    • Calvert GC, Lawrence BD, Abtahi AM, Bachus KN, Brodke DS. Cortical screws used to rescue failed lumbar pedicle screw construct: a biomechanical analysis. J Neurosurg Spine, 2015, 22: 166-172.
    • (2015) J Neurosurg Spine , vol.22 , pp. 166-172
    • Calvert, G.C.1    Lawrence, B.D.2    Abtahi, A.M.3    Bachus, K.N.4    Brodke, D.S.5
  • 17
    • 84908436166 scopus 로고    scopus 로고
    • Effect of physiological loads on cortical and traditional pedicle screw fixation
    • Baluch DA, Patel AA, Lullo B, etal. Effect of physiological loads on cortical and traditional pedicle screw fixation. Spine (Phila Pa 1976), 2014, 39: E1297-E1302.
    • (2014) Spine (Phila Pa 1976) , vol.39 , pp. E1297-E1302
    • Baluch, D.A.1    Patel, A.A.2    Lullo, B.3
  • 18
    • 84876415609 scopus 로고    scopus 로고
    • Biomechanics of lumbar cortical screw-rod fixation versus pedicle screw-rod fixation with and without interbody support
    • Perez-Orribo L, Kalb S, Reyes PM, Chang SW, Crawford NR. Biomechanics of lumbar cortical screw-rod fixation versus pedicle screw-rod fixation with and without interbody support. Spine (Phila Pa 1976), 2013, 38: 635-641.
    • (2013) Spine (Phila Pa 1976) , vol.38 , pp. 635-641
    • Perez-Orribo, L.1    Kalb, S.2    Reyes, P.M.3    Chang, S.W.4    Crawford, N.R.5
  • 19
    • 84942127121 scopus 로고    scopus 로고
    • Simulating the long-term biomechanical performance of cortical screws: can a more MIS screw option provide equivalent stability as traditional pedicle screws? Proceeding of SMISS Global Forum
    • Radcliff K, Klocke N, Harris J, etal. Simulating the long-term biomechanical performance of cortical screws: can a more MIS screw option provide equivalent stability as traditional pedicle screws? Proceeding of SMISS Global Forum, 2014.
    • (2014)
    • Radcliff, K.1    Klocke, N.2    Harris, J.3
  • 20
    • 84905495112 scopus 로고    scopus 로고
    • Cortical bone trajectory for lumbosacral fixation: penetrating S-1 endplate screw technique: technical note
    • Matsukawa K, Yato Y, Kato T, Imabayashi H, Asazuma T, Nemoto K. Cortical bone trajectory for lumbosacral fixation: penetrating S-1 endplate screw technique: technical note. J Neurosurg Spine, 2014, 21: 203-209.
    • (2014) J Neurosurg Spine , vol.21 , pp. 203-209
    • Matsukawa, K.1    Yato, Y.2    Kato, T.3    Imabayashi, H.4    Asazuma, T.5    Nemoto, K.6
  • 21
    • 77954887689 scopus 로고    scopus 로고
    • Monosegmental pedicle screw fixation for thoraco-lumbar burst fracture
    • Steel TR, Rust TM, Fairhall JM, Mobbs RJ. Monosegmental pedicle screw fixation for thoraco-lumbar burst fracture. J Bone Joint Surg Br, 2004, 86 (Suppl. IV): 458.
    • (2004) J Bone Joint Surg Br , vol.86 , pp. 458
    • Steel, T.R.1    Rust, T.M.2    Fairhall, J.M.3    Mobbs, R.J.4
  • 22
    • 84887105085 scopus 로고    scopus 로고
    • Posterior corrective fusion using a double-trajectory technique (cortical bone trajectory combined with traditional trajectory) for degenerative lumbar scoliosis with osteoporosis: technical note
    • Ueno M, Imura T, Inoue G, Takaso M. Posterior corrective fusion using a double-trajectory technique (cortical bone trajectory combined with traditional trajectory) for degenerative lumbar scoliosis with osteoporosis: technical note. J Neurosurg Spine, 2013, 19: 600-607.
    • (2013) J Neurosurg Spine , vol.19 , pp. 600-607
    • Ueno, M.1    Imura, T.2    Inoue, G.3    Takaso, M.4
  • 23
    • 84942081928 scopus 로고    scopus 로고
    • Cortical bone trajectory versus percutaneous pedicle screw in minimally invasive posterior lumbar fusion
    • Gonchar I, Kotani Y, Matsumoto Y. Cortical bone trajectory versus percutaneous pedicle screw in minimally invasive posterior lumbar fusion. Spine J, 2014, 14: S114-S115.
    • (2014) Spine J , vol.14 , pp. S114-S115
    • Gonchar, I.1    Kotani, Y.2    Matsumoto, Y.3
  • 24
    • 84942127122 scopus 로고    scopus 로고
    • Experience of 100 consecutive spine reconstructions using cortical bone trajectory (CBT) screws vs traditional pedicle screws. Proceeding of SMISS Global Forum
    • Gonchar I, Kotani Y, Matsui Y, Miyazaki T, Kasemura T, Masuko T. Experience of 100 consecutive spine reconstructions using cortical bone trajectory (CBT) screws vs traditional pedicle screws. Proceeding of SMISS Global Forum, 2014.
    • (2014)
    • Gonchar, I.1    Kotani, Y.2    Matsui, Y.3    Miyazaki, T.4    Kasemura, T.5    Masuko, T.6
  • 27
    • 84942127123 scopus 로고    scopus 로고
    • Comparison study of lumbar interbody fusion with cortical bone trajectory screws versus conventional open posterior lumbar interbody fusion. Proceeding of SMISS Global Forum
    • Okudaira T, Konishi H, Baba H, Hiura K, Yamashita K, Yamada S. Comparison study of lumbar interbody fusion with cortical bone trajectory screws versus conventional open posterior lumbar interbody fusion. Proceeding of SMISS Global Forum, 2014.
    • (2014)
    • Okudaira, T.1    Konishi, H.2    Baba, H.3    Hiura, K.4    Yamashita, K.5    Yamada, S.6
  • 28
    • 84897667745 scopus 로고    scopus 로고
    • Novel placement of cortical bone trajectory screws in previously instrumented pedicles for adjacent-segment lumbar disease using CT image-guided navigation
    • Rodriguez A, Neal MT, Liu A, Somasundaram A, Hsu W, Branch CL Jr. Novel placement of cortical bone trajectory screws in previously instrumented pedicles for adjacent-segment lumbar disease using CT image-guided navigation. Neurosurg Focus, 2014, 36: E9.
    • (2014) Neurosurg Focus , vol.36 , pp. E9
    • Rodriguez, A.1    Neal, M.T.2    Liu, A.3    Somasundaram, A.4    Hsu, W.5    Branch, C.L.6
  • 29
    • 84907562798 scopus 로고    scopus 로고
    • Hybrid technique of cortical bone trajectory and pedicle screwing for minimally invasive spine reconstruction surgery: a technical note
    • Takata Y, Matsuura T, Higashino K, etal. Hybrid technique of cortical bone trajectory and pedicle screwing for minimally invasive spine reconstruction surgery: a technical note. J Med Invest, 2014, 61: 388-392.
    • (2014) J Med Invest , vol.61 , pp. 388-392
    • Takata, Y.1    Matsuura, T.2    Higashino, K.3
  • 30
    • 84881012172 scopus 로고    scopus 로고
    • The "medio-latero-superior trajectory technique": an alternative cortical trajectory for pedicle fixation
    • Mobbs RJ. The "medio-latero-superior trajectory technique": an alternative cortical trajectory for pedicle fixation. Orthop Surg, 2013, 5: 56-59.
    • (2013) Orthop Surg , vol.5 , pp. 56-59
    • Mobbs, R.J.1
  • 31
    • 84929381070 scopus 로고    scopus 로고
    • Systematic review and meta-analysis: techniques and a guide for the academic surgeon
    • Phan K, Tian DH, Cao C, Black D, Yan TD. Systematic review and meta-analysis: techniques and a guide for the academic surgeon. Ann Cardiothorac Surg, 2015, 4: 112-122.
    • (2015) Ann Cardiothorac Surg , vol.4 , pp. 112-122
    • Phan, K.1    Tian, D.H.2    Cao, C.3    Black, D.4    Yan, T.D.5
  • 32
    • 0027203876 scopus 로고
    • Pedicle screw pullout strength. Correlation with insertional torque
    • Zdeblick TA, Kunz DN, Cooke ME, McCabe R. Pedicle screw pullout strength. Correlation with insertional torque. Spine (Phila Pa 1976), 1993, 18: 1673-1676.
    • (1993) Spine (Phila Pa 1976) , vol.18 , pp. 1673-1676
    • Zdeblick, T.A.1    Kunz, D.N.2    Cooke, M.E.3    McCabe, R.4
  • 33
    • 0016910007 scopus 로고
    • Osteosynthesis of thoraco-lumbar spine fractures with metal plates screwed through the vertebral pedicles
    • Roy-Camille R, Saillant G, Berteaux D, Salgado V. Osteosynthesis of thoraco-lumbar spine fractures with metal plates screwed through the vertebral pedicles. Reconstr Surg Traumatol, 1976, 15: 2-16.
    • (1976) Reconstr Surg Traumatol , vol.15 , pp. 2-16
    • Roy-Camille, R.1    Saillant, G.2    Berteaux, D.3    Salgado, V.4
  • 34
    • 0026437203 scopus 로고
    • Posterior screw plate fixation in thoracolumbar injuries
    • Roy-Camille R. Posterior screw plate fixation in thoracolumbar injuries. Instr Course Lect, 1992, 41: 157-163.
    • (1992) Instr Course Lect , vol.41 , pp. 157-163
    • Roy-Camille, R.1
  • 36
    • 0018764348 scopus 로고
    • The anatomy of the so-called "articular nerves" and their relationship to facet denervation in the treatment of low-back pain
    • Bogduk N, Long DM. The anatomy of the so-called "articular nerves" and their relationship to facet denervation in the treatment of low-back pain. J Neurosurg, 1979, 51: 172-177.
    • (1979) J Neurosurg , vol.51 , pp. 172-177
    • Bogduk, N.1    Long, D.M.2
  • 38
    • 0032532465 scopus 로고    scopus 로고
    • Clinical relevance of accuracy of pedicle screw placement. A computed tomographic-supported analysis
    • discussion 20-21.
    • Schulze CJ, Munzinger E, Weber U. Clinical relevance of accuracy of pedicle screw placement. A computed tomographic-supported analysis. Spine (Phila Pa 1976), 1998, 23: 2215-2220, discussion 20-21.
    • (1998) Spine (Phila Pa 1976) , vol.23 , pp. 2215-2220
    • Schulze, C.J.1    Munzinger, E.2    Weber, U.3
  • 39
    • 84942136322 scopus 로고    scopus 로고
    • Systematic reviews and meta-analyses in spine surgery, neurosurgery and orthopedics: guidelines for the surgeon scientist
    • Phan K, Mobbs RJ. Systematic reviews and meta-analyses in spine surgery, neurosurgery and orthopedics: guidelines for the surgeon scientist. J Spine Surg, 2015, doi: 10.3978/jss.2015.06.01.
    • (2015) J Spine Surg
    • Phan, K.1    Mobbs, R.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.