메뉴 건너뛰기




Volumn 54, Issue 9, 2014, Pages 716-721

Midline lumbar fusion with cortical bone trajectory screw

Author keywords

Cortical bone trajectory; Midline lumbar fusion; Minimum invasive; Osteoporosis; Spondylolisthesis

Indexed keywords

ADULT; ARTICLE; BONE GRAFT; BONE SCREW; CAUDO CEPHALAD PATH; CLINICAL ARTICLE; CLINICAL PATHWAY; FEMALE; HUMAN; LAMINECTOMY; MALE; MEDICAL RECORD REVIEW; MIDDLE AGED; MIDLINE LUMBAR FUSION; MINIMALLY INVASIVE PROCEDURE; RADIODIAGNOSIS; SPINE FUSION; SPONDYLOLISTHESIS; TREATMENT OUTCOME; AGED; BONE TRANSPLANTATION; DEVICES; LUMBAR VERTEBRA; MICROSURGERY; NUCLEAR MAGNETIC RESONANCE IMAGING; OSTEOPOROSIS; PATHOLOGY; PEDICLE SCREW; PROCEDURES; PROSTHESIS IMPLANTATION; THREE DIMENSIONAL IMAGING; VERY ELDERLY; X-RAY COMPUTED TOMOGRAPHY;

EID: 84907481196     PISSN: 04708105     EISSN: 13498029     Source Type: Journal    
DOI: 10.2176/nmc.st.2013-0395     Document Type: Article
Times cited : (72)

References (16)
  • 2
    • 79955916080 scopus 로고    scopus 로고
    • Technique, challenges and indications for percutaneous pedicle screw fixation
    • Mobbs RJ, Sivabalan P, Li J: Technique, challenges and indications for percutaneous pedicle screw fixation. J Clin Neurosci 18: 741–749, 2011
    • (2011) J Clin Neurosci , vol.18 , pp. 741-749
    • Mobbs, R.J.1    Sivabalan, P.2    Li, J.3
  • 4
    • 77955385364 scopus 로고    scopus 로고
    • The biomechanics of pedicle screw-based instrumentation
    • Cho W, Cho SK, Wu C: The biomechanics of pedicle screw-based instrumentation. J Bone Joint Surg Br 92: 1061–1065, 2010
    • (2010) J Bone Joint Surg Br , vol.92 , pp. 1061-1065
    • Cho, W.1    Cho, S.K.2    Wu, C.3
  • 6
    • 84862779081 scopus 로고    scopus 로고
    • Minimally invasive surgery compared to open spinal fusion for the treatment of degenerative lumbar spine pathologies
    • Mobbs RJ, Sivabalan P, Li J: Minimally invasive surgery compared to open spinal fusion for the treatment of degenerative lumbar spine pathologies. J Clin Neurosci 19: 829–835, 2012
    • (2012) J Clin Neurosci , vol.19 , pp. 829-835
    • Mobbs, R.J.1    Sivabalan, P.2    Li, J.3
  • 7
    • 0026398196 scopus 로고
    • Degenerative lumbar spon-dylolisthesis with spinal stenosis. A prospective study comparing decompression with decompression and intertransverse process arthrodesis
    • Herkowitz HN, Kurz LT: Degenerative lumbar spon-dylolisthesis with spinal stenosis. A prospective study comparing decompression with decompression and intertransverse process arthrodesis. J Bone Joint Surg Am 73: 802–808, 1991
    • (1991) J Bone Joint Surg Am , vol.73 , pp. 802-808
    • Herkowitz, H.N.1    Kurz, L.T.2
  • 8
    • 84907509920 scopus 로고    scopus 로고
    • Microsurgical Trumpet Laminectomy, minimum invasive surgical techniques for lumbar canal stenosis
    • Japanese
    • Mizuno M, Kubo Y, Niwa S, Microsurgical Trumpet Laminectomy, minimum invasive surgical techniques for lumbar canal stenosis. Spine & Spinal Cord 18: 303–309, 2005 (Japanese)
    • (2005) Spine & Spinal Cord , vol.18 , pp. 303-309
    • Mizuno, M.1    Kubo, Y.2    Niwa, S.3
  • 9
    • 69749126213 scopus 로고    scopus 로고
    • Mini-open versus conventional open posterior lumbar interbody fusion for the treatment of lumbar degenerative spondylolisthesis: Comparison of paraspinal muscle damage and slip reduction
    • Tsutsumimoto T, Shimogata M, Ohta H, Misawa H: Mini-open versus conventional open posterior lumbar interbody fusion for the treatment of lumbar degenerative spondylolisthesis: comparison of paraspinal muscle damage and slip reduction. Spine 34: 1923–1928, 2009
    • (2009) Spine , vol.34 , pp. 1923-1928
    • Tsutsumimoto, T.1    Shimogata, M.2    Ohta, H.3    Misawa, H.4
  • 10
    • 84907506484 scopus 로고    scopus 로고
    • In vivo analysis of insertion torque during pedicle screwing using cortical bone trajectory Technique
    • Japanese
    • Matsukawa K, Yato Y, Kato T, Imabayashi H, Asazuma T, Nemoto K: [In vivo analysis of insertion torque during pedicle screwing using cortical bone trajectory Technique]. Spine & Spinal Cord 26: 665–671, 2013 (Japanese)
    • (2013) Spine & Spinal Cord , vol.26 , pp. 665-671
    • Matsukawa, K.1    Yato, Y.2    Kato, T.3    Imabayashi, H.4    Asazuma, T.5    Nemoto, K.6
  • 11
    • 84876415609 scopus 로고    scopus 로고
    • Biomechanics of lumbar cortical screw-rod fixation versus pedicle screw-rod fxa-tion with and without interbody support
    • Perez-Orribo L, Kalb S, Reyes PM, Chang SW, Crawford NR: Biomechanics of lumbar cortical screw-rod fixation versus pedicle screw-rod fxa-tion with and without interbody support. Spine 38: 635–641, 2013
    • (2013) Spine , vol.38 , pp. 635-641
    • Perez-Orribo, L.1    Kalb, S.2    Reyes, P.M.3    Chang, S.W.4    Crawford, N.R.5
  • 12
    • 0031837773 scopus 로고    scopus 로고
    • Biome-chanical study of lumbar pedicle screws: Does convergence affect axial pullout strength?
    • Barber JW, Boden SD, Ganey T, Hutton WC: Biome-chanical study of lumbar pedicle screws: does convergence affect axial pullout strength? J Spinal Disord 11: 215–220, 1998
    • (1998) J Spinal Disord , vol.11 , pp. 215-220
    • Barber, J.W.1    Boden, S.D.2    Ganey, T.3    Hutton, W.C.4
  • 13
    • 84881012172 scopus 로고    scopus 로고
    • The “medio-latero-superior trajectory technique”: An alternative cortical trajectory for pedicle fixation
    • Mobbs RJ: The “medio-latero-superior trajectory technique”: an alternative cortical trajectory for pedicle fixation. Orthop Surg 5: 56–59, 2013
    • (2013) Orthop Surg , vol.5 , pp. 56-59
    • Mobbs, R.J.1
  • 14
    • 84907558939 scopus 로고    scopus 로고
    • Muscle-preserving posterior lumbar inter-body fusion using cortical bone trajectory screws
    • Japanese
    • Shiraishi T, Aoyama T, Yamane J, Ninomiya K, Ueda S, Kato K: [Muscle-preserving posterior lumbar inter-body fusion using cortical bone trajectory screws]. Seikei-saigai 56: 69–75, 2013 (Japanese)
    • (2013) Seikei-saigai , vol.56 , pp. 69-75
    • Shiraishi, T.1    Aoyama, T.2    Yamane, J.3    Ninomiya, K.4    Ueda, S.5    Kato, K.6
  • 15
    • 84881477180 scopus 로고    scopus 로고
    • Morphometric measurement of cortical bone trajectory for lumbar pedicle screw insertion using computed tomography
    • Matsukawa K, Yato Y, Nemoto O, Imabayashi H, Asazuma T, Nemoto K: Morphometric measurement of cortical bone trajectory for lumbar pedicle screw insertion using computed tomography. J Spinal Disord Tech 26: E248–E253, 2013
    • (2013) J Spinal Disord Tech , vol.26 , pp. E248-E253
    • Matsukawa, K.1    Yato, Y.2    Nemoto, O.3    Imabayashi, H.4    Asazuma, T.5    Nemoto, K.6
  • 16
    • 79955603027 scopus 로고    scopus 로고
    • Pedicle screw insertion angle and pullout strength: Comparison of 2 proposed strategies
    • Inceoğlu S, Montgomery WH, St Clair S, McLain RF: Pedicle screw insertion angle and pullout strength: comparison of 2 proposed strategies. J Neurosurg Spine 14: 670–676, 2011
    • (2011) J Neurosurg Spine , vol.14 , pp. 670-676
    • Inceoğlu, S.1    Montgomery, W.H.2    St Clair, S.3    McLain, R.F.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.