메뉴 건너뛰기




Volumn 21, Issue 2, 2014, Pages 203-209

Cortical bone trajectory for lumbosacral fixation: Penetrating S-1 endplate screw technique: Technical note

Author keywords

Cortical bone trajectory; Insertional torque; Lumbar bicortical sacral screw; Lumbosacral fixation; Sacral endplate; Sacrum; Technique

Indexed keywords

ADULT; AGED; ARTICLE; BINOCULAR CONVERGENCE; COMPUTER ASSISTED TOMOGRAPHY; CORTICAL BONE TRAJECTORY; DEVICE SAFETY; DUAL ENERGY X RAY ABSORPTIOMETRY; FEMALE; FORCE; FRICTION; HUMAN; INTERVERTEBRAL DISK; LUMBOSACRAL SPINE; MAJOR CLINICAL STUDY; MALE; MIDDLE AGED; MORPHOMETRICS; NERVE ENDING; ORTHOPEDIC SURGERY; PEDICLE SCREW; PLATE FIXATION; SPINE STABILIZATION; SURGICAL TECHNIQUE; TORQUE; VERTEBRA BODY; VERY ELDERLY;

EID: 84905495112     PISSN: 15475654     EISSN: 15475646     Source Type: Journal    
DOI: 10.3171/2014.3.SPINE13665     Document Type: Article
Times cited : (68)

References (30)
  • 2
    • 0031837773 scopus 로고    scopus 로고
    • Biomechanical study of lumbar pedicle screws: Does convergence affect axial pullout strength?
    • Barber JW, Boden SD, Ganey T, Hutton WC: Biomechanical study of lumbar pedicle screws: does convergence affect axial pullout strength? J Spinal Disord 11:215-220, 1998 (Pubitemid 28278167)
    • (1998) Journal of Spinal Disorders , vol.11 , Issue.3 , pp. 215-220
    • Barber, J.W.1    Boden, S.D.2    Ganey, T.3    Hutton, W.C.4
  • 4
    • 65549171537 scopus 로고    scopus 로고
    • Low profile pelvic fixation: Anatomic parameters for sacral alariliac fixation versus traditional iliac fixation
    • Chang TL, Sponseller PD, Kebaish KM, Fishman EK: Low profile pelvic fixation: anatomic parameters for sacral alariliac fixation versus traditional iliac fixation. Spine (Phila Pa 1976) 34:436-440, 2009
    • (2009) Spine (Phila Pa 1976) , vol.34 , pp. 436-440
    • Chang, T.L.1    Sponseller, P.D.2    Kebaish, K.M.3    Fishman, E.K.4
  • 5
    • 0033954922 scopus 로고    scopus 로고
    • Internal architecture of the sacrum in the elderly. An anatomic and radiographic study
    • Ebraheim N, Sabry FF, Nadim Y, Xu R, Yeasting RA: Internal architecture of the sacrum in the elderly. An anatomic and radiographic study. Spine (Phila Pa 1976) 25:292-297, 2000
    • (2000) Spine (Phila Pa 1976) , vol.25 , pp. 292-297
    • Ebraheim, N.1    Sabry, F.F.2    Nadim, Y.3    Xu, R.4    Yeasting, R.A.5
  • 6
    • 34548592230 scopus 로고    scopus 로고
    • Neurovascular risks of sacral screws with bicortical purchase: An anatomical study
    • DOI 10.1007/s00586-007-0326-x
    • Ergur I, Akcali O, Kiray A, Kosay C, Tayefi H: Neurovascular risks of sacral screws with bicortical purchase: an anatomical study. Eur Spine J 16:1519-1523, 2007 (Pubitemid 47389499)
    • (2007) European Spine Journal , vol.16 , Issue.9 , pp. 1519-1523
    • Ergur, I.1    Akcali, O.2    Kiray, A.3    Kosay, C.4    Tayefi, H.5
  • 9
    • 78650385318 scopus 로고    scopus 로고
    • Spinal instrumentation for sacral-pelvic fixation: A biomechanical comparison between constructs ending with either S2 bicortical, bitriangulated screws or iliac screws
    • Kim JH, Horton W, Hamasaki T, Freedman B, Whitesides TE Jr, Hutton WC: Spinal instrumentation for sacral-pelvic fixation: a biomechanical comparison between constructs ending with either S2 bicortical, bitriangulated screws or iliac screws. J Spinal Disord Tech 23:506-512, 2010
    • (2010) J Spinal Disord Tech , vol.23 , pp. 506-512
    • Kim, J.H.1    Horton, W.2    Hamasaki, T.3    Freedman, B.4    Whitesides Jr., T.E.5    Hutton, W.C.6
  • 10
    • 0024152846 scopus 로고
    • Depth of insertion of transpedicular vertebral screws into human vertebrae: Effect upon screw-vertebra interface strength
    • Krag MH, Beynnon BD, Pope MH, DeCoster TA: Depth of insertion of transpedicular vertebral screws into human vertebrae: effect upon screw-vertebra interface strength. J Spinal Disord 1:287-294, 1988 (Pubitemid 19157350)
    • (1988) Journal of Spinal Disorders , vol.1 , Issue.4 , pp. 287-294
    • Krag, M.H.1    Beynnon, B.D.2    Pope, M.H.3    DeCoster, T.A.4
  • 11
    • 0037089381 scopus 로고    scopus 로고
    • Advantage of pedicle screw fixation directed into the apex of the sacral promontory over bicortical fixation: A biomechanical analysis
    • Lehman RA Jr, Kuklo TR, Belmont PJ Jr, Andersen RC, Polly DW Jr: Advantage of pedicle screw fixation directed into the apex of the sacral promontory over bicortical fixation: a biomechanical analysis. Spine (Phila Pa 1976) 27:806-811, 2002
    • (2002) Spine (Phila Pa 1976) , vol.27 , pp. 806-811
    • Lehman Jr., R.A.1    Kuklo, T.R.2    Belmont Jr., P.J.3    Andersen, R.C.4    Polly Jr., D.W.5
  • 12
    • 0032213850 scopus 로고    scopus 로고
    • Comparison of the strengths of lumbosacral fixation achieved with techniques using one and two triangulated sacral screws
    • Leong JCY, Lu WW, Zheng Y, Zhu Q, Zhong S: Comparison of the strengths of lumbosacral fixation achieved with techniques using one and two triangulated sacral screws. Spine (Phila Pa 1976) 23:2289-2294, 1998
    • (1998) Spine (Phila Pa 1976) , vol.23 , pp. 2289-2294
    • Leong, J.C.Y.1    Lu, W.W.2    Zheng, Y.3    Zhu, Q.4    Zhong, S.5
  • 13
    • 14344261941 scopus 로고    scopus 로고
    • A stronger bicortical sacral pedicle screw fixation through the S1 endplate: An in vitro cyclic loading and pull-out force evaluation
    • Luk KDK, Chen L, Lu WW: A stronger bicortical sacral pedicle screw fixation through the S1 endplate: an in vitro cyclic loading and pull-out force evaluation. Spine (Phila Pa 1976) 30:525-529, 2005
    • (2005) Spine (Phila Pa 1976) , vol.30 , pp. 525-529
    • Luk, K.D.K.1    Chen, L.2    Lu, W.W.3
  • 14
    • 84881477180 scopus 로고    scopus 로고
    • Morphometric measurement of cortical bone trajectory for lumbar pedicle screw insertion using computed tomography
    • Matsukawa K, Yato Y, Nemoto O, Imabayashi H, Asazuma T, Nemoto K: Morphometric measurement of cortical bone trajectory for lumbar pedicle screw insertion using computed tomography. J Spinal Disord Tech 26:E248-E253, 2013
    • (2013) J Spinal Disord Tech , vol.26
    • Matsukawa, K.1    Yato, Y.2    Nemoto, O.3    Imabayashi, H.4    Asazuma, T.5    Nemoto, K.6
  • 18
    • 0033998139 scopus 로고    scopus 로고
    • Can insertional torque predict screw loosening and related failures? An in vivo study of pedicle screw fixation augmenting posterior lumbar interbody fusion
    • Okuyama K, Abe E, Suzuki T, Tamura Y, Chiba M, Sato K: Can insertional torque predict screw loosening and related failures? An in vivo study of pedicle screw fixation augmenting posterior lumbar interbody fusion. Spine (Phila Pa 1976) 25:858-864, 2000
    • (2000) Spine (Phila Pa 1976) , vol.25 , pp. 858-864
    • Okuyama, K.1    Abe, E.2    Suzuki, T.3    Tamura, Y.4    Chiba, M.5    Sato, K.6
  • 19
    • 77952371041 scopus 로고    scopus 로고
    • Advantages of the paraspinal muscle splitting approach in comparison with conventional midline approach for S1 pedicle screw placement
    • Ota M, Neo M, Fujibayashi S, Takemoto M, Nakamura T: Advantages of the paraspinal muscle splitting approach in comparison with conventional midline approach for S1 pedicle screw placement. Spine (Phila Pa 1976) 35:E452-E457, 2010
    • (2010) Spine (Phila Pa 1976) , vol.35
    • Ota, M.1    Neo, M.2    Fujibayashi, S.3    Takemoto, M.4    Nakamura, T.5
  • 22
    • 84876415609 scopus 로고    scopus 로고
    • Biomechanics of lumbar cortical screw-rod fixation versus pedicle screw-rod fixation with and without interbody support
    • Perez-Orribo L, Kalb S, Reyes PM, Chang SW, Crawford NR: Biomechanics of lumbar cortical screw-rod fixation versus pedicle screw-rod fixation with and without interbody support. Spine (Phila Pa 1976) 38:635-641, 2013
    • (2013) Spine (Phila Pa 1976) , vol.38 , pp. 635-641
    • Perez-Orribo, L.1    Kalb, S.2    Reyes, P.M.3    Chang, S.W.4    Crawford, N.R.5
  • 23
    • 0033503395 scopus 로고    scopus 로고
    • Pedicle screw placement at the sacrum: Anatomical characterization and limitations at S1
    • Robertson PA, Plank LD: Pedicle screw placement at the sacrum: anatomical characterization and limitations at S1. J Spinal Disord 12:227-233, 1999 (Pubitemid 30263410)
    • (1999) Journal of Spinal Disorders , vol.12 , Issue.3 , pp. 227-233
    • Robertson, P.A.1    Plank, L.D.2
  • 26
    • 0028900193 scopus 로고
    • Morphometric evaluation of the first sacral vertebra and the projection of its pedicle on the posterior aspect of the sacrum
    • Xu R, Ebraheim NA, Yeasting RA, Wong FY, Jackson WT: Morphometric evaluation of the first sacral vertebra and the projection of its pedicle on the posterior aspect of the sacrum. Spine (Phila Pa 1976) 20:936-940, 1995
    • (1995) Spine (Phila Pa 1976) , vol.20 , pp. 936-940
    • Xu, R.1    Ebraheim, N.A.2    Yeasting, R.A.3    Wong, F.Y.4    Jackson, W.T.5
  • 27
  • 28
    • 0033951314 scopus 로고    scopus 로고
    • Variation in bone mineral density of the sacrum in young adults and its significance for sacral fixation
    • Zheng Y, Lu WW, Zhu Q, Qin L, Zhong S, Leong JCY: Variation in bone mineral density of the sacrum in young adults and its significance for sacral fixation. Spine (Phila Pa 1976) 25:353-357, 2000
    • (2000) Spine (Phila Pa 1976) , vol.25 , pp. 353-357
    • Zheng, Y.1    Lu, W.W.2    Zhu, Q.3    Qin, L.4    Zhong, S.5    Leong, J.C.Y.6
  • 29
    • 0034194437 scopus 로고    scopus 로고
    • The effects of cyclic loading on pull-out strength of sacral screw fixation: An in vitro biomechanical study
    • Zhu Q, Lu WW, Holmes AD, Zheng Y, Zhong S, Leong JCY: The effects of cyclic loading on pull-out strength of sacral screw fixation: an in vitro biomechanical study. Spine (Phila Pa 1976) 25:1065-1069, 2000
    • (2000) Spine (Phila Pa 1976) , vol.25 , pp. 1065-1069
    • Zhu, Q.1    Lu, W.W.2    Holmes, A.D.3    Zheng, Y.4    Zhong, S.5    Leong, J.C.Y.6
  • 30
    • 0022628372 scopus 로고
    • A biomechanical study of intrapeduncular screw fixation in the lumbosacral spine
    • Zindrick MR, Wiltse LL, Widell EH, Thomas JC, Holland WR, Field BT, et al: A biomechanical study of intrapeduncular screw fixation in the lumbosacral spine. Clin Orthop Relat Res (203):99-112, 1986 (Pubitemid 16115318)
    • (1986) Clinical Orthopaedics and Related Research , Issue.203 , pp. 99-112
    • Zindrick, M.R.1    Wiltse, L.L.2    Widell, E.H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.