메뉴 건너뛰기




Volumn 39, Issue 7, 2015, Pages 787-822

Body Composition Tools for Assessment of Adult Malnutrition at the Bedside

Author keywords

bioimpedance; body cell mass; fat free mass; impedance ratio; intracellular water; lean body mass; malnutrition; muscle loss; muscle mass; nutrition status; phase angle; skeletal muscle; spectroscopy

Indexed keywords

ACOUSTIC IMPEDANCE; ADULT; AGED; ANALYTIC METHOD; ASSESSMENT OF HUMANS; BLAND ALTMAN ANALYSIS; BODY COMPOSITION; BODY POSITION; CLINICAL RESEARCH; COMPUTER ASSISTED TOMOGRAPHY; CORRELATION COEFFICIENT; DIAGNOSTIC ACCURACY; DIAGNOSTIC TEST ACCURACY STUDY; ECHOGRAPHY; ELECTROCHEMICAL IMPEDANCE SPECTROSCOPY; ENERGY EXPENDITURE; FAT FREE MASS; FEMALE; FUNCTIONAL STATUS; GOLD STANDARD; HUMAN; HYDRATION; IMPEDANCE; LEAN BODY WEIGHT; LINEAR REGRESSION ANALYSIS; MALE; MALNUTRITION; MIDDLE AGED; MUSCLE MASS; NEUTRON ACTIVATION ANALYSIS; NUTRITIONAL STATUS; PRIORITY JOURNAL; QUADRICEPS FEMORIS MUSCLE; RADIATION EXPOSURE; REFERENCE VALUE; REGRESSION ANALYSIS; REPRODUCIBILITY; REVIEW; SEX RATIO; STUDENT T TEST; TOTAL BODY POTASSIUM; TOTAL BODY WATER; URINALYSIS; VALIDATION PROCESS; VALIDATION STUDY; X RAY BONE DENSITOMETER; BODY MASS; METABOLISM; NUTRITIONAL ASSESSMENT; PHOTON ABSORPTIOMETRY; SKELETAL MUSCLE; THEORETICAL MODEL;

EID: 84939624235     PISSN: 01486071     EISSN: 19412444     Source Type: Journal    
DOI: 10.1177/0148607115595227     Document Type: Review
Times cited : (171)

References (208)
  • 1
    • 84865346447 scopus 로고    scopus 로고
    • Appropriate protein provision in critical illness: A systematic and narrative review
    • Hoffer LJ, Bistrian BR,. Appropriate protein provision in critical illness: a systematic and narrative review. Am J Clin Nutr. 2012; 96: 591-600.
    • (2012) Am J Clin Nutr , vol.96 , pp. 591-600
    • Hoffer, L.J.1    Bistrian, B.R.2
  • 2
    • 0343144797 scopus 로고    scopus 로고
    • Metabolic response to injury and sepsis: Changes in protein metabolism
    • Biolo G, Toigo G, Ciocchi B,. Metabolic response to injury and sepsis: changes in protein metabolism. Nutrition. 1997; 13 (9): 52S-57S.
    • (1997) Nutrition , vol.13 , Issue.9 , pp. 52S-57S
    • Biolo, G.1    Toigo, G.2    Ciocchi, B.3
  • 3
    • 77950340105 scopus 로고    scopus 로고
    • Consensus definition of sarcopenia, cachexia and pre-cachexia: Joint document elaborated by Special Interest Groups (SIG) '€'cachexia-anorexia in chronic wasting diseases'€' and '€'nutrition in geriatrics.'€'
    • Muscaritoli M, Anker SD, Argilés J,. Consensus definition of sarcopenia, cachexia and pre-cachexia: joint document elaborated by Special Interest Groups (SIG) '€'cachexia-anorexia in chronic wasting diseases'€' and '€'nutrition in geriatrics.'€'. Clin Nutr. 2010; 29 (2): 154-159.
    • (2010) Clin Nutr , vol.29 , Issue.2 , pp. 154-159
    • Muscaritoli, M.1    Anker, S.D.2    Argilés, J.3
  • 5
    • 84865863055 scopus 로고    scopus 로고
    • Sarcopenia is associated with postoperative infection and delayed recovery from colorectal cancer resection surgery
    • Lieffers JR, Bathe OF, Fassbender K, Winget M, Baracos VE,. Sarcopenia is associated with postoperative infection and delayed recovery from colorectal cancer resection surgery. Br J Cancer. 2012; 107 (6): 931-936.
    • (2012) Br J Cancer , vol.107 , Issue.6 , pp. 931-936
    • Lieffers, J.R.1    Bathe, O.F.2    Fassbender, K.3    Winget, M.4    Baracos, V.E.5
  • 6
    • 2142716770 scopus 로고    scopus 로고
    • Nutritional assessment: Lean body mass depletion at hospital admission is associated with an increased length of stay
    • Pichard C, Kyle UG, Morabia A, Perrier A, Vermeulen B, Unger P,. Nutritional assessment: lean body mass depletion at hospital admission is associated with an increased length of stay. Am J Clin Nutr. 2004; 79 (4): 613-618.
    • (2004) Am J Clin Nutr , vol.79 , Issue.4 , pp. 613-618
    • Pichard, C.1    Kyle, U.G.2    Morabia, A.3    Perrier, A.4    Vermeulen, B.5    Unger, P.6
  • 7
    • 84884252508 scopus 로고    scopus 로고
    • Skeletal muscle predicts ventilator-free days, ICU-free days, and mortality in elderly ICU patients
    • Moisey LL, Mourtzakis M, Cotton B,. Skeletal muscle predicts ventilator-free days, ICU-free days, and mortality in elderly ICU patients. Crit Care. 2013; 17 (5): R206.
    • (2013) Crit Care , vol.17 , Issue.5 , pp. R206
    • Moisey, L.L.1    Mourtzakis, M.2    Cotton, B.3
  • 8
    • 84856063726 scopus 로고    scopus 로고
    • Muscle wasting is associated with mortality in patients with cirrhosis
    • Montano-Loza AJ, Meza-Junco J, Prado CMM,. Muscle wasting is associated with mortality in patients with cirrhosis. Clin Gastroenterol Hepatol. 2012; 10 (2): 166-173.
    • (2012) Clin Gastroenterol Hepatol , vol.10 , Issue.2 , pp. 166-173
    • Montano-Loza, A.J.1    Meza-Junco, J.2    Prado, C.M.M.3
  • 9
    • 84855318187 scopus 로고    scopus 로고
    • Body composition, symptoms, and survival in advanced cancer patients referred to a phase i service
    • Parsons HA, Baracos VE, Dhillon N, Hong DS, Kurzrock R,. Body composition, symptoms, and survival in advanced cancer patients referred to a phase I service. PLoS One. 2012; 7 (1): e29330.
    • (2012) PLoS One , vol.7 , Issue.1 , pp. e29330
    • Parsons, H.A.1    Baracos, V.E.2    Dhillon, N.3    Hong, D.S.4    Kurzrock, R.5
  • 10
    • 0032522560 scopus 로고    scopus 로고
    • Epidemiology of sarcopenia among the elderly in New Mexico
    • Baumgartner RN, Koehler KM, Gallagher D,. Epidemiology of sarcopenia among the elderly in New Mexico. Am J Epidemiol. 1998; 147 (8): 755-763.
    • (1998) Am J Epidemiol , vol.147 , Issue.8 , pp. 755-763
    • Baumgartner, R.N.1    Koehler, K.M.2    Gallagher, D.3
  • 11
    • 45849124963 scopus 로고    scopus 로고
    • Prevalence and clinical implications of sarcopenic obesity in patients with solid tumours of the respiratory and gastrointestinal tracts: A population-based study
    • Prado CM, Lieffers JR, McCargar LJ,. Prevalence and clinical implications of sarcopenic obesity in patients with solid tumours of the respiratory and gastrointestinal tracts: a population-based study. Lancet Oncol. 2008; 9: 629-635.
    • (2008) Lancet Oncol , vol.9 , pp. 629-635
    • Prado, C.M.1    Lieffers, J.R.2    McCargar, L.J.3
  • 12
    • 0036246979 scopus 로고    scopus 로고
    • Low relative skeletal muscle mass (sarcopenia) in older persons is associated with functional impairment and physical disability
    • Janssen I, Heymsfield SB, Ross R,. Low relative skeletal muscle mass (sarcopenia) in older persons is associated with functional impairment and physical disability. J Am Geriatr Soc. 2002; 50 (5): 889-896.
    • (2002) J Am Geriatr Soc , vol.50 , Issue.5 , pp. 889-896
    • Janssen, I.1    Heymsfield, S.B.2    Ross, R.3
  • 13
    • 1042265092 scopus 로고    scopus 로고
    • Skeletal muscle cutpoints associated with elevated physical disability risk in older men and women
    • Janssen I, Baumgartner RN, Ross R, Rosenberg IH, Roubenoff R,. Skeletal muscle cutpoints associated with elevated physical disability risk in older men and women. Am J Epidemiol. 2004; 159 (4): 413-421.
    • (2004) Am J Epidemiol , vol.159 , Issue.4 , pp. 413-421
    • Janssen, I.1    Baumgartner, R.N.2    Ross, R.3    Rosenberg, I.H.4    Roubenoff, R.5
  • 14
    • 79955399340 scopus 로고    scopus 로고
    • Definition and classification of cancer cachexia: An international consensus
    • Fearon K, Strasser F, Anker SD,. Definition and classification of cancer cachexia: an international consensus. Lancet Oncol. 2011; 12 (5): 489-495.
    • (2011) Lancet Oncol , vol.12 , Issue.5 , pp. 489-495
    • Fearon, K.1    Strasser, F.2    Anker, S.D.3
  • 15
    • 84860279405 scopus 로고    scopus 로고
    • Consensus statement: Academy of Nutrition and Dietetics and American Society for Parenteral and Enteral Nutrition: Characteristics recommended for the identification and documentation of adult malnutrition (undernutrition)
    • White J, Guenter P, Jensen G, Malone A, Schofield M,. Consensus statement: Academy of Nutrition and Dietetics and American Society for Parenteral and Enteral Nutrition: characteristics recommended for the identification and documentation of adult malnutrition (undernutrition). JPEN J Parenter Enteral Nutr. 2012; 36 (3): 275-283.
    • (2012) JPEN J Parenter Enteral Nutr , vol.36 , Issue.3 , pp. 275-283
    • White, J.1    Guenter, P.2    Jensen, G.3    Malone, A.4    Schofield, M.5
  • 16
    • 84888623919 scopus 로고    scopus 로고
    • The Academy of Nutrition and Dietetics/the American Society for Parenteral and Enteral Nutrition consensus malnutrition characteristics: Application in practice
    • Malone A, Hamilton C,. The Academy of Nutrition and Dietetics/the American Society for Parenteral and Enteral Nutrition consensus malnutrition characteristics: application in practice. Nutr Clin Pract. 2013; 28 (6): 639-650.
    • (2013) Nutr Clin Pract , vol.28 , Issue.6 , pp. 639-650
    • Malone, A.1    Hamilton, C.2
  • 17
    • 77953870112 scopus 로고    scopus 로고
    • Sarcopenia: European consensus on definition and diagnosis
    • Cruz-Jentoft AJ, Baeyens JP, Bauer JM,. Sarcopenia: European consensus on definition and diagnosis. Age Ageing. 2010; 39 (4): 423.
    • (2010) Age Ageing , vol.39 , Issue.4 , pp. 423
    • Cruz-Jentoft, A.J.1    Baeyens, J.P.2    Bauer, J.M.3
  • 19
    • 84910106229 scopus 로고    scopus 로고
    • The prevalence of sarcopenia in patients with respiratory failure classified as normally nourished using computed tomography and subjective global assessment
    • Sheean PM, Peterson SJ, Gomez Perez S,. The prevalence of sarcopenia in patients with respiratory failure classified as normally nourished using computed tomography and subjective global assessment. JPEN J Parenter Enteral Nutr. 2014; 38 (7): 873-879.
    • (2014) JPEN J Parenter Enteral Nutr , vol.38 , Issue.7 , pp. 873-879
    • Sheean, P.M.1    Peterson, S.J.2    Gomez Perez, S.3
  • 22
    • 84855397331 scopus 로고    scopus 로고
    • Body composition (sarcopenia) in obese patients: Implications for care in the intensive care unit
    • Gallager D, DeLegge M,. Body composition (sarcopenia) in obese patients: implications for care in the intensive care unit. JPEN J Parenter Enteral Nutr. 2011; 35 (1): 21S-28S.
    • (2011) JPEN J Parenter Enteral Nutr , vol.35 , Issue.1 , pp. 21S-28S
    • Gallager, D.1    DeLegge, M.2
  • 23
    • 84876581806 scopus 로고    scopus 로고
    • Cancer cachexia in the age of obesity: Skeletal muscle depletion is a powerful prognostic factor, independent of body mass index
    • Martin L, Birdsell L, Macdonald N,. Cancer cachexia in the age of obesity: skeletal muscle depletion is a powerful prognostic factor, independent of body mass index. J Clin Oncol. 2013; 31 (12): 1539-1547.
    • (2013) J Clin Oncol , vol.31 , Issue.12 , pp. 1539-1547
    • Martin, L.1    Birdsell, L.2    Macdonald, N.3
  • 25
    • 0035131549 scopus 로고    scopus 로고
    • Multi-component body composition models: Recent advances and future directions
    • Pietrobelli A, Heymsfield SB, Wang ZM, Gallagher D,. Multi-component body composition models: recent advances and future directions. Eur J Clin Nutr. 2001; 55: 69-75.
    • (2001) Eur J Clin Nutr , vol.55 , pp. 69-75
    • Pietrobelli, A.1    Heymsfield, S.B.2    Wang, Z.M.3    Gallagher, D.4
  • 27
    • 0038178033 scopus 로고    scopus 로고
    • Body composition assessment in extreme obesity and after massive weight loss induced by gastric bypass surgery
    • Das SK, Roberts SB, Kehayias JJ,. Body composition assessment in extreme obesity and after massive weight loss induced by gastric bypass surgery. Am J Physiol Endocrinol Metab. 2003; 284 (6): E1080-E1088.
    • (2003) Am J Physiol Endocrinol Metab , vol.284 , Issue.6 , pp. E1080-E1088
    • Das, S.K.1    Roberts, S.B.2    Kehayias, J.J.3
  • 28
    • 0034043158 scopus 로고    scopus 로고
    • Relative overhydration of fat-free mass in postobese versus never-obese subjects
    • Leone PA, Gallagher D, Wang J, Heymsfield SB,. Relative overhydration of fat-free mass in postobese versus never-obese subjects. Ann N Y Acad Sci. 2000; 904: 514-519.
    • (2000) Ann N y Acad Sci , vol.904 , pp. 514-519
    • Leone, P.A.1    Gallagher, D.2    Wang, J.3    Heymsfield, S.B.4
  • 29
    • 84910027309 scopus 로고    scopus 로고
    • Lean tissue imaging: A new era for nutritional assessment and intervention
    • Prado CMM, Heymsfield SB,. Lean tissue imaging: a new era for nutritional assessment and intervention. JPEN J Parenter Enteral Nutr. 2014; 38: 940-953.
    • (2014) JPEN J Parenter Enteral Nutr , vol.38 , pp. 940-953
    • Prado, C.M.M.1    Heymsfield, S.B.2
  • 30
    • 0002961196 scopus 로고
    • Body cell mass and limits of hydration of the fat-free body: Their relation to estimated skeletal weight
    • Moore FD, Boyden CM,. Body cell mass and limits of hydration of the fat-free body: their relation to estimated skeletal weight. Ann N Y Acad Sci. 1963; 110: 62-71.
    • (1963) Ann N y Acad Sci , vol.110 , pp. 62-71
    • Moore, F.D.1    Boyden, C.M.2
  • 31
    • 9144248985 scopus 로고    scopus 로고
    • Body cell mass: Model development and validation at the cellular level of body composition
    • Wang Z, St-Onge M-P, Lecumberri B,. Body cell mass: model development and validation at the cellular level of body composition. Am J Physiol Endocrinol Metab. 2004; 286 (1): E123-E128.
    • (2004) Am J Physiol Endocrinol Metab , vol.286 , Issue.1 , pp. E123-E128
    • Wang, Z.1    St-Onge, M.-P.2    Lecumberri, B.3
  • 32
    • 0025300470 scopus 로고
    • Nutritional assessment with body composition measurements by multiple isotope dilution
    • (suppl)
    • Shizgal HM,. Nutritional assessment with body composition measurements by multiple isotope dilution. JPEN J Parenter Enteral Nutr. 1990; 17 (3)(suppl): 9-17.
    • (1990) JPEN J Parenter Enteral Nutr , vol.17 , Issue.3 , pp. 9-17
    • Shizgal, H.M.1
  • 33
    • 34948909214 scopus 로고    scopus 로고
    • Bioimpedance spectroscopy for clinical assessment of fluid distribution and body cell mass
    • Earthman C, Traughber D, Dobratz J, Howell W,. Bioimpedance spectroscopy for clinical assessment of fluid distribution and body cell mass. Nutr Clin Pract. 2007; 22 (4): 389-405.
    • (2007) Nutr Clin Pract , vol.22 , Issue.4 , pp. 389-405
    • Earthman, C.1    Traughber, D.2    Dobratz, J.3    Howell, W.4
  • 34
    • 0029811018 scopus 로고    scopus 로고
    • Metabolically active component of fat-free body mass: Influences of age, adiposity, and gender
    • Gallagher D, Visser M, Wang Z, Harris T, Pierson RN, Heymsfield SB,. Metabolically active component of fat-free body mass: influences of age, adiposity, and gender. Metabolism. 1996; 45 (8): 992-997.
    • (1996) Metabolism , vol.45 , Issue.8 , pp. 992-997
    • Gallagher, D.1    Visser, M.2    Wang, Z.3    Harris, T.4    Pierson, R.N.5    Heymsfield, S.B.6
  • 35
    • 0032080011 scopus 로고    scopus 로고
    • The quality of the body cell mass - 1996. Are we ready to measure it?
    • Pierson RN, Wang J, Thornton J, Heymsfield S,. The quality of the body cell mass-1996. Are we ready to measure it? Appl Radiat Isot. 1998; 49 (5): 429-435.
    • (1998) Appl Radiat Isot , vol.49 , Issue.5 , pp. 429-435
    • Pierson, R.N.1    Wang, J.2    Thornton, J.3    Heymsfield, S.4
  • 36
    • 0023547386 scopus 로고
    • Nutritional assessment with body composition measurements
    • (suppl)
    • Shizgal HM,. Nutritional assessment with body composition measurements. JPEN J Parenter Enteral Nutr. 1987; 11 (5)(suppl): 42S-47S.
    • (1987) JPEN J Parenter Enteral Nutr , vol.11 , Issue.5 , pp. 42S-47S
    • Shizgal, H.M.1
  • 37
    • 0022103034 scopus 로고
    • Hydration of fat-free body in protein-depleted patients
    • Beddoe A, Streat S, Hill G,. Hydration of fat-free body in protein-depleted patients. Am J Physiol. 1985; 249 (2, pt 1): E227-E233.
    • (1985) Am J Physiol , vol.249 , pp. E227-E233
    • Beddoe, A.1    Streat, S.2    Hill, G.3
  • 38
    • 0021167655 scopus 로고
    • Whole body cellular and collagen nitrogen in healthy and wasted man
    • James HM, Dabek JT, Chettle DR,. Whole body cellular and collagen nitrogen in healthy and wasted man. Clin Sci (Lond). 1984; 67: 73-82.
    • (1984) Clin Sci (Lond) , vol.67 , pp. 73-82
    • James, H.M.1    Dabek, J.T.2    Chettle, D.R.3
  • 39
    • 58149132163 scopus 로고    scopus 로고
    • Assessment methods in human body composition
    • Lee SY, Gallagher D,. Assessment methods in human body composition. Curr Opin Clin Nutr Metab Care. 2008; 11 (5): 566-572.
    • (2008) Curr Opin Clin Nutr Metab Care , vol.11 , Issue.5 , pp. 566-572
    • Lee, S.Y.1    Gallagher, D.2
  • 40
    • 84863419801 scopus 로고    scopus 로고
    • Advances in the science and application of body composition measurement
    • Baracos V, Caserotti P, Earthman CP,. Advances in the science and application of body composition measurement. JPEN J Parenter Enteral Nutr. 2012; 36 (1): 96-107.
    • (2012) JPEN J Parenter Enteral Nutr , vol.36 , Issue.1 , pp. 96-107
    • Baracos, V.1    Caserotti, P.2    Earthman, C.P.3
  • 41
    • 0030615216 scopus 로고    scopus 로고
    • Comparing methods of measurement
    • Ludbrook J,. Comparing methods of measurement. Clin Exp Pharmacol Physiol. 1997; 24 (2): 193-203.
    • (1997) Clin Exp Pharmacol Physiol , vol.24 , Issue.2 , pp. 193-203
    • Ludbrook, J.1
  • 42
    • 0032886760 scopus 로고    scopus 로고
    • Anthropometric measurement error and the assessment of nutritional status
    • Ulijaszek SJ, Kerr DA,. Anthropometric measurement error and the assessment of nutritional status. Br J Nutr. 1999; 82: 165.
    • (1999) Br J Nutr , vol.82 , pp. 165
    • Ulijaszek, S.J.1    Kerr, D.A.2
  • 44
    • 0021714977 scopus 로고
    • Research design and analysis of data procedures for predicting body density
    • Jackson AS,. Research design and analysis of data procedures for predicting body density. Med Sci Sports Exerc. 1984; 16 (6): 616-620.
    • (1984) Med Sci Sports Exerc , vol.16 , Issue.6 , pp. 616-620
    • Jackson, A.S.1
  • 45
    • 84872161280 scopus 로고    scopus 로고
    • What makes a BIA equation unique? Validity of eight-electrode multifrequency BIA to estimate body composition in a healthy adult population
    • (suppl 1)
    • Bosy-Westphal A, Schautz B, Later W, Kehayias J, Gallagher D, Müller M,. What makes a BIA equation unique? Validity of eight-electrode multifrequency BIA to estimate body composition in a healthy adult population. Eur J Clin Nutr. 2013; 67 (suppl 1): S14-S21.
    • (2013) Eur J Clin Nutr , vol.67 , pp. S14-S21
    • Bosy-Westphal, A.1    Schautz, B.2    Later, W.3    Kehayias, J.4    Gallagher, D.5    Müller, M.6
  • 46
    • 0034058703 scopus 로고    scopus 로고
    • A comparison of bioimpedance methods for detection of body cell mass change in HIV infection
    • Earthman CP, Matthie JR, Reid PM, Harper IT, Ravussin E, Howell WH,. A comparison of bioimpedance methods for detection of body cell mass change in HIV infection. J Appl Physiol. 2000; 88 (3): 944-956.
    • (2000) J Appl Physiol , vol.88 , Issue.3 , pp. 944-956
    • Earthman, C.P.1    Matthie, J.R.2    Reid, P.M.3    Harper, I.T.4    Ravussin, E.5    Howell, W.H.6
  • 47
    • 0034094682 scopus 로고    scopus 로고
    • Validation of bio-impedance spectroscopy: Effects of degree of obesity and ways of calculating volumes from measured resistance values
    • Cox-Reijven PL, Soeters PB,. Validation of bio-impedance spectroscopy: effects of degree of obesity and ways of calculating volumes from measured resistance values. Int J Obes Relat Metab Disord. 2000; 24 (3): 271-280.
    • (2000) Int J Obes Relat Metab Disord , vol.24 , Issue.3 , pp. 271-280
    • Cox-Reijven, P.L.1    Soeters, P.B.2
  • 48
    • 0036178326 scopus 로고    scopus 로고
    • Accuracy of bioelectrical impedance spectroscopy in measuring changes in body composition during severe weight loss
    • Cox-Reijven PLM, van Kreel B, Soeters PB,. Accuracy of bioelectrical impedance spectroscopy in measuring changes in body composition during severe weight loss. JPEN J Parenter Enteral Nutr. 2002; 26 (2): 120-127.
    • (2002) JPEN J Parenter Enteral Nutr , vol.26 , Issue.2 , pp. 120-127
    • Cox-Reijven, P.L.M.1    Van Kreel, B.2    Soeters, P.B.3
  • 49
    • 56049112558 scopus 로고    scopus 로고
    • Multifrequency bioelectrical impedance analysis and bioimpedance spectroscopy for monitoring fluid and body cell mass changes after gastric bypass surgery
    • Mager JR, Sibley SD, Beckman TR, Kellogg TA, Earthman CP,. Multifrequency bioelectrical impedance analysis and bioimpedance spectroscopy for monitoring fluid and body cell mass changes after gastric bypass surgery. Clin Nutr. 2008; 27 (6): 832-841.
    • (2008) Clin Nutr , vol.27 , Issue.6 , pp. 832-841
    • Mager, J.R.1    Sibley, S.D.2    Beckman, T.R.3    Kellogg, T.A.4    Earthman, C.P.5
  • 51
    • 84879204283 scopus 로고    scopus 로고
    • Critical role of nutrition in improving quality of care: An interdisciplinary call to action to address adult hospital malnutrition
    • Tappenden KA, Quatrara B, Parkhurst ML, Malone AM, Fanjiang G, Ziegler TR,. Critical role of nutrition in improving quality of care: an interdisciplinary call to action to address adult hospital malnutrition. JPEN J Parenter Enteral Nutr. 2013; 37 (4): 482-497.
    • (2013) JPEN J Parenter Enteral Nutr , vol.37 , Issue.4 , pp. 482-497
    • Tappenden, K.A.1    Quatrara, B.2    Parkhurst, M.L.3    Malone, A.M.4    Fanjiang, G.5    Ziegler, T.R.6
  • 52
    • 0038287894 scopus 로고    scopus 로고
    • Correlation and simple linear regression
    • Zou KH, Tuncali K, Silverman SG,. Correlation and simple linear regression. Radiology. 2003; 227: 617-628.
    • (2003) Radiology , vol.227 , pp. 617-628
    • Zou, K.H.1    Tuncali, K.2    Silverman, S.G.3
  • 53
    • 0025325984 scopus 로고
    • Interpretation of the correlation coefficient: A basic review
    • Taylor R,. Interpretation of the correlation coefficient: a basic review. J Diagnostic Med Sonogr. 1990; 6 (1): 35-39.
    • (1990) J Diagnostic Med Sonogr , vol.6 , Issue.1 , pp. 35-39
    • Taylor, R.1
  • 54
    • 84875268549 scopus 로고    scopus 로고
    • Basic statistical concepts in nutrition research
    • Saracino G, Jennings LW, Hasse JM,. Basic statistical concepts in nutrition research. Nutr Clin Pract. 2013; 28 (2): 182-193.
    • (2013) Nutr Clin Pract , vol.28 , Issue.2 , pp. 182-193
    • Saracino, G.1    Jennings, L.W.2    Hasse, J.M.3
  • 55
    • 84939613239 scopus 로고    scopus 로고
    • Lane DM,. Online estatsbook. http://onlinestatbook.com/2/regression/accuracy.html. Accessed January 27, 2015.
    • Online Estatsbook
    • Lane, D.M.1
  • 56
    • 0000148378 scopus 로고    scopus 로고
    • Comment on the use of concordance correlation to assess the agreement between two variables
    • Atkinson G, Nevill A,. Comment on the use of concordance correlation to assess the agreement between two variables. Biometrics. 1997; 53 (2): 775-777.
    • (1997) Biometrics , vol.53 , Issue.2 , pp. 775-777
    • Atkinson, G.1    Nevill, A.2
  • 57
    • 0038675123 scopus 로고    scopus 로고
    • Applying the right statistics: Analyses of measurement studies
    • Bland JM, Altman DG,. Applying the right statistics: analyses of measurement studies. Ultrasound Obstet Gynecol. 2003; 22: 85-93.
    • (2003) Ultrasound Obstet Gynecol , vol.22 , pp. 85-93
    • Bland, J.M.1    Altman, D.G.2
  • 58
    • 0033967320 scopus 로고    scopus 로고
    • General Deming regression for estimating systematic bias and its confidence interval in method-comparison studies
    • Martin RF,. General Deming regression for estimating systematic bias and its confidence interval in method-comparison studies. Clin Chem. 2000; 46 (1): 100-104.
    • (2000) Clin Chem , vol.46 , Issue.1 , pp. 100-104
    • Martin, R.F.1
  • 59
    • 0031729269 scopus 로고    scopus 로고
    • Validity of linear regression in method comparison studies: Is it limited by the statistical model or the quality of the analytical input data?
    • Stöckl D, Dewitte K, Thienpont LM,. Validity of linear regression in method comparison studies: is it limited by the statistical model or the quality of the analytical input data? Clin Chem. 1998; 44 (11): 2340-2346.
    • (1998) Clin Chem , vol.44 , Issue.11 , pp. 2340-2346
    • Stöckl, D.1    Dewitte, K.2    Thienpont, L.M.3
  • 60
    • 0021045350 scopus 로고
    • A new biometrical procedure for testing the equality of measurements from two different analytical methods: Application of linear regression procedures for method comparison studies in clinical chemistry, part i
    • Passing H, Bablok W,. A new biometrical procedure for testing the equality of measurements from two different analytical methods: application of linear regression procedures for method comparison studies in clinical chemistry, part I. J Clin Chem Clin Biochem. 1983; 21 (11): 709-720.
    • (1983) J Clin Chem Clin Biochem , vol.21 , Issue.11 , pp. 709-720
    • Passing, H.1    Bablok, W.2
  • 61
    • 84942072472 scopus 로고
    • Comparison of several regression procedures for method comparison studies and determination of sample sizes: Application of linear regression procedures for method comparison studies in clinical chemistry, part II
    • Passing H, Bablok W,. Comparison of several regression procedures for method comparison studies and determination of sample sizes: application of linear regression procedures for method comparison studies in clinical chemistry, part II. J Clin Chem Clin Biochem. 1984; 22 (6): 431-445.
    • (1984) J Clin Chem Clin Biochem , vol.22 , Issue.6 , pp. 431-445
    • Passing, H.1    Bablok, W.2
  • 62
    • 79951688389 scopus 로고    scopus 로고
    • Lessons in biostatistics comparison of methods: Passing and Bablok regression
    • Bilic-Zulle L,. Lessons in biostatistics comparison of methods: Passing and Bablok regression. Biochem Med. 2011; 21 (3): 49-52.
    • (2011) Biochem Med , vol.21 , Issue.3 , pp. 49-52
    • Bilic-Zulle, L.1
  • 63
    • 0021807587 scopus 로고
    • Application of statistical procedures in analytical instrument testing
    • Bablok W, Passing H,. Application of statistical procedures in analytical instrument testing. J Automat Chem. 1985; 7 (2): 74-79.
    • (1985) J Automat Chem , vol.7 , Issue.2 , pp. 74-79
    • Bablok, W.1    Passing, H.2
  • 64
    • 0027414009 scopus 로고
    • Evaluation of regression procedures for methods comparison studies
    • Linnet K,. Evaluation of regression procedures for methods comparison studies. Clin Chem. 1993; 39 (3): 424-432.
    • (1993) Clin Chem , vol.39 , Issue.3 , pp. 424-432
    • Linnet, K.1
  • 65
    • 0018341055 scopus 로고
    • Incorrect least-squares regression coefficients in method-comparison analysis
    • Cornbleet PJ, Gochman N,. Incorrect least-squares regression coefficients in method-comparison analysis. Clin Chem. 1979; 25 (3): 432-438.
    • (1979) Clin Chem , vol.25 , Issue.3 , pp. 432-438
    • Cornbleet, P.J.1    Gochman, N.2
  • 66
    • 0024521543 scopus 로고
    • A concordance correlation coefficient to evaluate reproducibility
    • Lin LI,. A concordance correlation coefficient to evaluate reproducibility. Biometrics. 1989; 45 (1): 255-268.
    • (1989) Biometrics , vol.45 , Issue.1 , pp. 255-268
    • Lin, L.I.1
  • 67
    • 0029927989 scopus 로고    scopus 로고
    • A weighted concordance correlation coefficient for repeated measurement designs
    • Chinchilli VM, Martel JK, Kumanyika S, Lloyd T,. A weighted concordance correlation coefficient for repeated measurement designs. Biometrics. 1996; 52 (1): 341-353.
    • (1996) Biometrics , vol.52 , Issue.1 , pp. 341-353
    • Chinchilli, V.M.1    Martel, J.K.2    Kumanyika, S.3    Lloyd, T.4
  • 68
    • 34347395135 scopus 로고    scopus 로고
    • A repeated measures concordance correlation coefficient
    • King TS, Chinchilli VM, Carrasco JL,. A repeated measures concordance correlation coefficient. Stat Med. 2007; 26 (16): 3095-3113.
    • (2007) Stat Med , vol.26 , Issue.16 , pp. 3095-3113
    • King, T.S.1    Chinchilli, V.M.2    Carrasco, J.L.3
  • 69
    • 0032884749 scopus 로고    scopus 로고
    • Measuring agreement in method comparison studies
    • Bland JM, Altman DG,. Measuring agreement in method comparison studies. Stat Methods Med Res. 1999; 8 (99): 135-160.
    • (1999) Stat Methods Med Res , vol.8 , Issue.99 , pp. 135-160
    • Bland, J.M.1    Altman, D.G.2
  • 70
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG,. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986; 1 (8476): 307-310.
    • (1986) Lancet , vol.1 , Issue.8476 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 71
    • 61349197573 scopus 로고    scopus 로고
    • Progressive statistics for studies in sports medicine and exercise science
    • Hopkins WG, Marshall SW, Batterham AM, Hanin J,. Progressive statistics for studies in sports medicine and exercise science. Med Sci Sports Exerc. 2009; 41 (1): 3-12.
    • (2009) Med Sci Sports Exerc , vol.41 , Issue.1 , pp. 3-12
    • Hopkins, W.G.1    Marshall, S.W.2    Batterham, A.M.3    Hanin, J.4
  • 72
    • 33744460863 scopus 로고    scopus 로고
    • Bias in Bland-Altman but not regression validity analyses
    • Hopkins WG,. Bias in Bland-Altman but not regression validity analyses. Sportscience. 2004; 8: 42-26.
    • (2004) Sportscience , vol.8 , pp. 42-26
    • Hopkins, W.G.1
  • 73
    • 48549092221 scopus 로고    scopus 로고
    • Design, analysis and interpretation of method-comparison studies
    • Hanneman SK,. Design, analysis and interpretation of method-comparison studies. AACN Adv Crit Care. 2008; 19 (2): 223-234.
    • (2008) AACN Adv Crit Care , vol.19 , Issue.2 , pp. 223-234
    • Hanneman, S.K.1
  • 74
    • 75649119259 scopus 로고    scopus 로고
    • Confidence in Altman-Bland plots: A critical review of the method of differences
    • Ludbrook J,. Confidence in Altman-Bland plots: a critical review of the method of differences. Clin Exp Pharmacol Physiol. 2010; 37 (2): 143-149.
    • (2010) Clin Exp Pharmacol Physiol , vol.37 , Issue.2 , pp. 143-149
    • Ludbrook, J.1
  • 75
    • 84872139093 scopus 로고    scopus 로고
    • Bioelectrical impedance validation studies: Alternative approaches to their interpretation
    • (suppl 1)
    • Ward LC,. Bioelectrical impedance validation studies: alternative approaches to their interpretation. Eur J Clin Nutr. 2013; 67 (suppl 1): S10-S13.
    • (2013) Eur J Clin Nutr , vol.67 , pp. S10-S13
    • Ward, L.C.1
  • 76
    • 68849121782 scopus 로고    scopus 로고
    • Bench-to-bedside review: The importance of the precision of the reference technique in method comparison studies - With specific reference to the measurement of cardiac output
    • Cecconi M, Rhodes A, Poloniecki J, Della Rocca G, Grounds RM,. Bench-to-bedside review: the importance of the precision of the reference technique in method comparison studies-with specific reference to the measurement of cardiac output. Crit Care. 2009; 13: 201.
    • (2009) Crit Care , vol.13 , pp. 201
    • Cecconi, M.1    Rhodes, A.2    Poloniecki, J.3    Della Rocca, G.4    Grounds, R.M.5
  • 77
    • 0033003166 scopus 로고    scopus 로고
    • A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques
    • Critchley LA, Critchley JA,. A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques. J Clin Monit Comput. 1999; 15: 85-91.
    • (1999) J Clin Monit Comput , vol.15 , pp. 85-91
    • Critchley, L.A.1    Critchley, J.A.2
  • 78
    • 0034116222 scopus 로고    scopus 로고
    • Human body composition: In vivo methods
    • Ellis KJ,. Human body composition: in vivo methods. Physiol Rev. 2000; 80 (2): 649-680.
    • (2000) Physiol Rev , vol.80 , Issue.2 , pp. 649-680
    • Ellis, K.J.1
  • 79
    • 84939606053 scopus 로고    scopus 로고
    • In-vivo and in-vitro bromide equilibration time course in adults and sample handling effect
    • Schlosser K, Kehayias J, Tegenkamp M, Schoeller D,. In-vivo and in-vitro bromide equilibration time course in adults and sample handling effect. Int J Body Compos Res. 2009; 7 (4): 141-146.
    • (2009) Int J Body Compos Res , vol.7 , Issue.4 , pp. 141-146
    • Schlosser, K.1    Kehayias, J.2    Tegenkamp, M.3    Schoeller, D.4
  • 80
    • 0242693176 scopus 로고    scopus 로고
    • Precision of the doubly labeled water method in a large-scale application: Evaluation of a streamlined-dosing protocol in the Observing Protein and Energy Nutrition (OPEN) study
    • Trabulsi J, Troiano R, Subar A,. Precision of the doubly labeled water method in a large-scale application: evaluation of a streamlined-dosing protocol in the Observing Protein and Energy Nutrition (OPEN) study. Eur J Clin Nutr. 2003; 57 (11): 1370-1377.
    • (2003) Eur J Clin Nutr , vol.57 , Issue.11 , pp. 1370-1377
    • Trabulsi, J.1    Troiano, R.2    Subar, A.3
  • 84
    • 0024312652 scopus 로고
    • Bromide space determination using anion-exchange chromatography for measurement of bromide
    • Miller E,. Bromide space determination using anion-exchange chromatography for measurement of bromide. Am J Clin Nutr. 1989; 50 (1): 168-171.
    • (1989) Am J Clin Nutr , vol.50 , Issue.1 , pp. 168-171
    • Miller, E.1
  • 85
    • 0021433390 scopus 로고
    • Anion-exchange chromatographic determination of bromide in serum
    • Miller ME, Cappon CJ,. Anion-exchange chromatographic determination of bromide in serum. Clin Chem. 1984; 30 (5): 781-783.
    • (1984) Clin Chem , vol.30 , Issue.5 , pp. 781-783
    • Miller, M.E.1    Cappon, C.J.2
  • 86
    • 84856358067 scopus 로고    scopus 로고
    • Water homeostasis, frailty and cognitive function in the nursing home
    • Kehayias J, Ribeiro S, Skahan A,. Water homeostasis, frailty and cognitive function in the nursing home. J Nutr Heal Aging. 2012; 16 (1): 35-39.
    • (2012) J Nutr Heal Aging , vol.16 , Issue.1 , pp. 35-39
    • Kehayias, J.1    Ribeiro, S.2    Skahan, A.3
  • 87
    • 84939611429 scopus 로고    scopus 로고
    • International Atomic Energy Agency, Division of Human Health
    • Nutritional and Health-Related Environmental Studies. International Atomic Energy Agency, Division of Human Health. Hum Heal Ser. 2014. http://www-naweb.iaea.org/nahu/NAHRES/publication.html. Accessed April 19, 2015.
    • (2014) Hum Heal ser
  • 89
    • 0030061711 scopus 로고    scopus 로고
    • Reliability of the doubly labeled water method for the measurement of total daily energy expenditure in free-living subjects
    • Schoeller DA, Hnilicka JM,. Reliability of the doubly labeled water method for the measurement of total daily energy expenditure in free-living subjects. J Nutr. 1996; 126 (1): 348S-354S.
    • (1996) J Nutr , vol.126 , Issue.1 , pp. 348S-354S
    • Schoeller, D.A.1    Hnilicka, J.M.2
  • 90
    • 34247568590 scopus 로고    scopus 로고
    • Alternative definitions of sarcopenia, lower extremity performance, and functional impairment with aging in older men and women
    • Delmonico MJ, Harris TB, Lee JS,. Alternative definitions of sarcopenia, lower extremity performance, and functional impairment with aging in older men and women. J Am Geriatr Soc. 2007; 55 (5): 769-774.
    • (2007) J Am Geriatr Soc , vol.55 , Issue.5 , pp. 769-774
    • Delmonico, M.J.1    Harris, T.B.2    Lee, J.S.3
  • 91
    • 58149108980 scopus 로고    scopus 로고
    • Reproducibility of DXA measurements of bone mineral density and body composition in children
    • Leonard CM, Roza MA, Barr RD, Webber CE,. Reproducibility of DXA measurements of bone mineral density and body composition in children. Pediatr Radiol. 2009; 39: 148-154.
    • (2009) Pediatr Radiol , vol.39 , pp. 148-154
    • Leonard, C.M.1    Roza, M.A.2    Barr, R.D.3    Webber, C.E.4
  • 92
    • 0030965341 scopus 로고    scopus 로고
    • Components of variance when assessing the reproducibility of body composition measurements using bio-impedance and the Hologic QDR-2000 DXA scanner
    • Jensen M, Hermann A, Hessov I, Mosekilde L,. Components of variance when assessing the reproducibility of body composition measurements using bio-impedance and the Hologic QDR-2000 DXA scanner. Clin Nutr. 1997; 16 (2): 61-65.
    • (1997) Clin Nutr , vol.16 , Issue.2 , pp. 61-65
    • Jensen, M.1    Hermann, A.2    Hessov, I.3    Mosekilde, L.4
  • 93
    • 79551614788 scopus 로고    scopus 로고
    • Muscle wasting in cancer cachexia: Clinical implications, diagnosis, and emerging treatment strategies
    • Dodson S, Baracos VE, Jatoi A,. Muscle wasting in cancer cachexia: clinical implications, diagnosis, and emerging treatment strategies. Annu Rev Med. 2011; 62: 265-279.
    • (2011) Annu Rev Med , vol.62 , pp. 265-279
    • Dodson, S.1    Baracos, V.E.2    Jatoi, A.3
  • 94
    • 53649107585 scopus 로고    scopus 로고
    • A practical and precise approach to quantification of body composition in cancer patients using computed tomography images acquired during routine care
    • Mourtzakis M, Prado CMM, Lieffers JR, Reiman T, McCargar LJ, Baracos VE,. A practical and precise approach to quantification of body composition in cancer patients using computed tomography images acquired during routine care. Appl Physiol Nutr Metab. 2008; 33 (5): 997-1006.
    • (2008) Appl Physiol Nutr Metab , vol.33 , Issue.5 , pp. 997-1006
    • Mourtzakis, M.1    Prado, C.M.M.2    Lieffers, J.R.3    Reiman, T.4    McCargar, L.J.5    Baracos, V.E.6
  • 96
    • 8744237041 scopus 로고    scopus 로고
    • Bioelectrical impedance analysis - Part II: Utilization in clinical practice
    • Kyle UG, Bosaeus I, De Lorenzo AD,. Bioelectrical impedance analysis-part II: utilization in clinical practice. Clin Nutr. 2004; 23 (6): 1430-1453.
    • (2004) Clin Nutr , vol.23 , Issue.6 , pp. 1430-1453
    • Kyle, U.G.1    Bosaeus, I.2    De Lorenzo, A.D.3
  • 97
    • 84927130153 scopus 로고    scopus 로고
    • Bioimpedance at the bedside: Current applications, limitations, and opportunities
    • Mulasi U, Kuchnia AJ, Cole AJ, Earthman CP,. Bioimpedance at the bedside: current applications, limitations, and opportunities. Nutr Clin Pract. 2015; 30 (2): 180-193.
    • (2015) Nutr Clin Pract , vol.30 , Issue.2 , pp. 180-193
    • Mulasi, U.1    Kuchnia, A.J.2    Cole, A.J.3    Earthman, C.P.4
  • 98
    • 0036957389 scopus 로고    scopus 로고
    • Body composition estimates from NHANES III bioelectrical impedance data
    • Chumlea WC, Guo SS, Kuczmarski RJ,. Body composition estimates from NHANES III bioelectrical impedance data. Int J Obes Relat Metab Disord. 2002; 26 (12): 1596-1609.
    • (2002) Int J Obes Relat Metab Disord , vol.26 , Issue.12 , pp. 1596-1609
    • Chumlea, W.C.1    Guo, S.S.2    Kuczmarski, R.J.3
  • 100
    • 84872156713 scopus 로고    scopus 로고
    • Evolution of bioimpedance: A circuitous journey from estimation of physiological function to assessment of body composition and a return to clinical research
    • (suppl 1)
    • Lukaski HC,. Evolution of bioimpedance: a circuitous journey from estimation of physiological function to assessment of body composition and a return to clinical research. Eur J Clin Nutr. 2013; 67 (suppl 1): S2-S9.
    • (2013) Eur J Clin Nutr , vol.67 , pp. S2-S9
    • Lukaski, H.C.1
  • 101
    • 4544322570 scopus 로고    scopus 로고
    • Bioelectrical impedance analysis - Part I: Review of principles and methods
    • Kyle UG, Bosaeus I, De Lorenzo AD,. Bioelectrical impedance analysis-part I: review of principles and methods. Clin Nutr. 2004; 23 (5): 1226-1243.
    • (2004) Clin Nutr , vol.23 , Issue.5 , pp. 1226-1243
    • Kyle, U.G.1    Bosaeus, I.2    De Lorenzo, A.D.3
  • 102
    • 49849100171 scopus 로고    scopus 로고
    • Bioimpedance measurements of human body composition: Critical analysis and outlook
    • Matthie JR,. Bioimpedance measurements of human body composition: critical analysis and outlook. Expert Rev Med Devices. 2008; 5 (2): 239-261.
    • (2008) Expert Rev Med Devices , vol.5 , Issue.2 , pp. 239-261
    • Matthie, J.R.1
  • 103
    • 56249087544 scopus 로고    scopus 로고
    • Body fluid volumes measurements by impedance: A review of bioimpedance spectroscopy (BIS) and bioimpedance analysis (BIA) methods
    • Jaffrin MY, Morel H,. Body fluid volumes measurements by impedance: a review of bioimpedance spectroscopy (BIS) and bioimpedance analysis (BIA) methods. Med Eng Phys. 2008; 30 (10): 1257-1269.
    • (2008) Med Eng Phys , vol.30 , Issue.10 , pp. 1257-1269
    • Jaffrin, M.Y.1    Morel, H.2
  • 104
    • 84902974742 scopus 로고    scopus 로고
    • Analysis of body composition: A critical review of the use of bioelectrical impedance analysis
    • Mialich MS, Maria J, Sicchieri F, Afonso A, Junior J,. Analysis of body composition: a critical review of the use of bioelectrical impedance analysis. Int J Clin Nutr. 2014; 2 (1): 1-10.
    • (2014) Int J Clin Nutr , vol.2 , Issue.1 , pp. 1-10
    • Mialich, M.S.1    Maria, J.2    Sicchieri, F.3    Afonso, A.4    Junior, J.5
  • 105
    • 0029783015 scopus 로고    scopus 로고
    • Use of bioelectrical impedance analysis measurements in the clinical management of patients undergoing dialysis
    • (suppl)
    • Kushner RF, de Vries PM, Gudivaka R,. Use of bioelectrical impedance analysis measurements in the clinical management of patients undergoing dialysis. Am J Clin Nutr. 1996; 64 (3)(suppl): 503S-509S.
    • (1996) Am J Clin Nutr , vol.64 , Issue.3 , pp. 503S-509S
    • Kushner, R.F.1    De Vries, P.M.2    Gudivaka, R.3
  • 106
    • 78149487428 scopus 로고    scopus 로고
    • Reproducibility and validity of bioimpedance spectroscopy for tracking changes in total body water: Implications for repeated measurements
    • Moon JR, Stout JR, Smith AE,. Reproducibility and validity of bioimpedance spectroscopy for tracking changes in total body water: implications for repeated measurements. Br J Nutr. 2010; 104 (9): 1384-1394.
    • (2010) Br J Nutr , vol.104 , Issue.9 , pp. 1384-1394
    • Moon, J.R.1    Stout, J.R.2    Smith, A.E.3
  • 108
    • 0029740978 scopus 로고    scopus 로고
    • Clinical characteristics influencing bioelectrical impedance analysis measurements
    • (suppl)
    • Kushner RF, Gudivaka R, Schoeller DA,. Clinical characteristics influencing bioelectrical impedance analysis measurements. Am J Clin Nutr. 1996; 64 (suppl): 423S-427S.
    • (1996) Am J Clin Nutr , vol.64 , pp. 423S-427S
    • Kushner, R.F.1    Gudivaka, R.2    Schoeller, D.A.3
  • 109
    • 85047696573 scopus 로고    scopus 로고
    • Total body water measurement using bioelectrical impedance analysis, isotope dilution and total body potassium: A scoring system to facilitate intercomparison
    • Gonzalez C, Evans J, Smye S, Holland P,. Total body water measurement using bioelectrical impedance analysis, isotope dilution and total body potassium: a scoring system to facilitate intercomparison. Eur J Clin Nutr. 2002; 56 (4): 326-337.
    • (2002) Eur J Clin Nutr , vol.56 , Issue.4 , pp. 326-337
    • Gonzalez, C.1    Evans, J.2    Smye, S.3    Holland, P.4
  • 110
    • 0028338537 scopus 로고
    • Segmental bioelectrical impedance analysis: Theory and application of a new technique
    • Organ L, Bradham G, Gore D, Lozier S,. Segmental bioelectrical impedance analysis: theory and application of a new technique. J Appl Physiol. 1994; 77 (1): 98-112.
    • (1994) J Appl Physiol , vol.77 , Issue.1 , pp. 98-112
    • Organ, L.1    Bradham, G.2    Gore, D.3    Lozier, S.4
  • 111
    • 84865520675 scopus 로고    scopus 로고
    • Segmental bioelectrical impedance analysis
    • Ward LC,. Segmental bioelectrical impedance analysis. Curr Opin Clin Nutr Metab Care. 2012; 15 (5): 424-429.
    • (2012) Curr Opin Clin Nutr Metab Care , vol.15 , Issue.5 , pp. 424-429
    • Ward, L.C.1
  • 112
    • 0030978220 scopus 로고    scopus 로고
    • Effect of postural changes on the reliability of volume estimations from bioimpedance spectroscopy data
    • Scharfetter H, Monif M, László Z, Lambauer T, Hutten H, Hinghofer-Szalkay H,. Effect of postural changes on the reliability of volume estimations from bioimpedance spectroscopy data. Kidney Int. 1997; 51: 1078-1087.
    • (1997) Kidney Int , vol.51 , pp. 1078-1087
    • Scharfetter, H.1    Monif, M.2    László, Z.3    Lambauer, T.4    Hutten, H.5    Hinghofer-Szalkay, H.6
  • 113
    • 0029764778 scopus 로고    scopus 로고
    • Effect of skin temperature on multifrequency bioelectrical impedance analysis
    • Gudivaka R, Schoeller D, Kushner RF,. Effect of skin temperature on multifrequency bioelectrical impedance analysis. J Appl Physiol. 1996; 81 (2): 838-845.
    • (1996) J Appl Physiol , vol.81 , Issue.2 , pp. 838-845
    • Gudivaka, R.1    Schoeller, D.2    Kushner, R.F.3
  • 114
    • 84872154696 scopus 로고    scopus 로고
    • Body composition by whole-body bioelectrical impedance and prediction of clinically relevant outcomes: Overvalued or underused?
    • (suppl 1)
    • Elia M,. Body composition by whole-body bioelectrical impedance and prediction of clinically relevant outcomes: overvalued or underused? Eur J Clin Nutr. 2013; 67 (suppl 1): S60-S70.
    • (2013) Eur J Clin Nutr , vol.67 , pp. S60-S70
    • Elia, M.1
  • 115
    • 84897377374 scopus 로고    scopus 로고
    • Comparison of fluid volume estimates in chronic hemodialysis patients by bioimpedance, direct isotopic, and dilution methods
    • Raimann JG, Zhu F, Wang J,. Comparison of fluid volume estimates in chronic hemodialysis patients by bioimpedance, direct isotopic, and dilution methods. Kidney Int. 2014; 85 (4): 898-908.
    • (2014) Kidney Int , vol.85 , Issue.4 , pp. 898-908
    • Raimann, J.G.1    Zhu, F.2    Wang, J.3
  • 116
    • 0029777445 scopus 로고    scopus 로고
    • Prediction of body cell mass, fat-free mass, and total body water with bioelectrical impedance analysis: Effects of race, sex, and disease
    • (suppl)
    • Kotler D, Burastero S, Wang J, Pierson R,. Prediction of body cell mass, fat-free mass, and total body water with bioelectrical impedance analysis: effects of race, sex, and disease. Am J Clin Nutr. 1996; 64 (suppl): 489S-497S.
    • (1996) Am J Clin Nutr , vol.64 , pp. 489S-497S
    • Kotler, D.1    Burastero, S.2    Wang, J.3    Pierson, R.4
  • 117
    • 0024446834 scopus 로고
    • Magnitude of body-cell-mass depletion and the timing of death from wasting in AIDS
    • Kotler DP, Tierney AR, Wang J, Pierson RN,. Magnitude of body-cell-mass depletion and the timing of death from wasting in AIDS. Am J Clin Nutr. 1989; 50 (3): 444-447.
    • (1989) Am J Clin Nutr , vol.50 , Issue.3 , pp. 444-447
    • Kotler, D.P.1    Tierney, A.R.2    Wang, J.3    Pierson, R.N.4
  • 118
    • 27444432435 scopus 로고    scopus 로고
    • Bioimpedance, dry weight and blood pressure control: New methods and consequences
    • Kuhlmann MK, Zhu F, Seibert E, Levin NW,. Bioimpedance, dry weight and blood pressure control: new methods and consequences. Curr Opin Nephrol Hypertens. 2005; 14 (6): 543-549.
    • (2005) Curr Opin Nephrol Hypertens , vol.14 , Issue.6 , pp. 543-549
    • Kuhlmann, M.K.1    Zhu, F.2    Seibert, E.3    Levin, N.W.4
  • 119
    • 77953606707 scopus 로고    scopus 로고
    • Calf bioimpedance ratio improves dry weight assessment and blood pressure control in hemodialysis patients
    • Zhou Y-L, Liu J, Sun F,. Calf bioimpedance ratio improves dry weight assessment and blood pressure control in hemodialysis patients. Am J Nephrol. 2010; 32 (2): 109-116.
    • (2010) Am J Nephrol , vol.32 , Issue.2 , pp. 109-116
    • Zhou, Y.-L.1    Liu, J.2    Sun, F.3
  • 120
    • 1842503926 scopus 로고    scopus 로고
    • Adjustment of dry weight in hemodialysis patients using intradialytic continuous multifrequency bioimpedance of the calf
    • Zhu F, Kuhlmann MK, Sarkar SKC,. Adjustment of dry weight in hemodialysis patients using intradialytic continuous multifrequency bioimpedance of the calf. Int J Artif Organs. 2004; 27 (2): 104-109.
    • (2004) Int J Artif Organs , vol.27 , Issue.2 , pp. 104-109
    • Zhu, F.1    Kuhlmann, M.K.2    Sarkar, S.K.C.3
  • 121
    • 65249173419 scopus 로고    scopus 로고
    • The mortality risk of overhydration in haemodialysis patients
    • Wizemann V, Wabel P, Chamney P,. The mortality risk of overhydration in haemodialysis patients. Nephrol Dial Transplant. 2009; 24 (5): 1574-1579.
    • (2009) Nephrol Dial Transplant , vol.24 , Issue.5 , pp. 1574-1579
    • Wizemann, V.1    Wabel, P.2    Chamney, P.3
  • 122
    • 58549120372 scopus 로고    scopus 로고
    • Towards improved cardiovascular management: The necessity of combining blood pressure and fluid overload
    • Wabel P, Moissl U, Chamney P,. Towards improved cardiovascular management: the necessity of combining blood pressure and fluid overload. Nephrol Dial Transplant. 2008; 23 (9): 2965-2971.
    • (2008) Nephrol Dial Transplant , vol.23 , Issue.9 , pp. 2965-2971
    • Wabel, P.1    Moissl, U.2    Chamney, P.3
  • 123
    • 84903832274 scopus 로고    scopus 로고
    • Clinical significance of multi-frequency bioimpedance spectroscopy in peritoneal dialysis patients: Independent predictor of patient survival
    • O'Lone EL, Visser A, Finney H, Fan SL,. Clinical significance of multi-frequency bioimpedance spectroscopy in peritoneal dialysis patients: independent predictor of patient survival. Nephrol Dial Transplant. 2014; 29 (7): 1430-1437.
    • (2014) Nephrol Dial Transplant , vol.29 , Issue.7 , pp. 1430-1437
    • O'Lone, E.L.1    Visser, A.2    Finney, H.3    Fan, S.L.4
  • 124
    • 84903278381 scopus 로고    scopus 로고
    • Bioimpedance-guided fluid management in maintenance hemodialysis: A pilot randomized controlled trial
    • Onofriescu M, Hogas S, Voroneanu L,. Bioimpedance-guided fluid management in maintenance hemodialysis: a pilot randomized controlled trial. Am J Kidney Dis. 2014; 64 (1): 111-118.
    • (2014) Am J Kidney Dis , vol.64 , Issue.1 , pp. 111-118
    • Onofriescu, M.1    Hogas, S.2    Voroneanu, L.3
  • 125
    • 0037403524 scopus 로고    scopus 로고
    • Can bioelectrical impedance analysis identify malnutrition in preoperative nutrition assessment?
    • Barbosa-Silva MCG, Barros AJD, Post CLA, Waitzberg DL, Heymsfield SB,. Can bioelectrical impedance analysis identify malnutrition in preoperative nutrition assessment? Nutrition. 2003; 19 (5): 422-426.
    • (2003) Nutrition , vol.19 , Issue.5 , pp. 422-426
    • Barbosa-Silva, M.C.G.1    Barros, A.J.D.2    Post, C.L.A.3    Waitzberg, D.L.4    Heymsfield, S.B.5
  • 126
    • 17844378715 scopus 로고    scopus 로고
    • Bioelectrical impedance analysis in clinical practice: A new perspective on its use beyond body composition equations
    • Barbosa-Silva MCG, Barros AJD,. Bioelectrical impedance analysis in clinical practice: a new perspective on its use beyond body composition equations. Curr Opin Clin Nutr Metab Care. 2005; 8 (3): 311-317.
    • (2005) Curr Opin Clin Nutr Metab Care , vol.8 , Issue.3 , pp. 311-317
    • Barbosa-Silva, M.C.G.1    Barros, A.J.D.2
  • 127
    • 84870243624 scopus 로고    scopus 로고
    • Bioelectrical phase angle and impedance vector analysis: Clinical relevance and applicability of impedance parameters
    • Norman K, Stobäus N, Pirlich M, Bosy-Westphal A,. Bioelectrical phase angle and impedance vector analysis: clinical relevance and applicability of impedance parameters. Clin Nutr. 2012; 31 (6): 854-861.
    • (2012) Clin Nutr , vol.31 , Issue.6 , pp. 854-861
    • Norman, K.1    Stobäus, N.2    Pirlich, M.3    Bosy-Westphal, A.4
  • 129
    • 84920684551 scopus 로고    scopus 로고
    • Bioelectrical impedance analysis to estimate body composition in surgical and oncological patients: A systematic review
    • Haverkort EB, Reijven PLM, Binnekade JM,. Bioelectrical impedance analysis to estimate body composition in surgical and oncological patients: a systematic review. Eur J Clin Nutr. 2015; 69 (1): 3-13.
    • (2015) Eur J Clin Nutr , vol.69 , Issue.1 , pp. 3-13
    • Haverkort, E.B.1    Reijven, P.L.M.2    Binnekade, J.M.3
  • 130
    • 84872160978 scopus 로고    scopus 로고
    • Bioelectrical impedance analysis for assessment of fluid status and body composition in neonates - The good, the bad and the unknown
    • (suppl 1)
    • Lingwood BE,. Bioelectrical impedance analysis for assessment of fluid status and body composition in neonates-the good, the bad and the unknown. Eur J Clin Nutr. 2013; 67 (suppl 1): S28-S33.
    • (2013) Eur J Clin Nutr , vol.67 , pp. S28-S33
    • Lingwood, B.E.1
  • 131
    • 4644262992 scopus 로고    scopus 로고
    • The validity of bioelectrical impedance models in clinical populations
    • Buchholz AC, Bartok C, Schoeller DA,. The validity of bioelectrical impedance models in clinical populations. Nutr Clin Pract. 2004; 19 (5): 433-446.
    • (2004) Nutr Clin Pract , vol.19 , Issue.5 , pp. 433-446
    • Buchholz, A.C.1    Bartok, C.2    Schoeller, D.A.3
  • 132
    • 0034130716 scopus 로고    scopus 로고
    • Bioelectrical impedance analysis: What does it measure?
    • Schoeller DA,. Bioelectrical impedance analysis: what does it measure? Ann N Y Acad Sci. 2000; 904: 159-162.
    • (2000) Ann N y Acad Sci , vol.904 , pp. 159-162
    • Schoeller, D.A.1
  • 133
    • 1242319548 scopus 로고    scopus 로고
    • Aging, physical activity and height-normalized body composition parameters
    • Kyle UG, Genton L, Gremion G, Slosman DO, Pichard C,. Aging, physical activity and height-normalized body composition parameters. Clin Nutr. 2004; 23 (1): 79-88.
    • (2004) Clin Nutr , vol.23 , Issue.1 , pp. 79-88
    • Kyle, U.G.1    Genton, L.2    Gremion, G.3    Slosman, D.O.4    Pichard, C.5
  • 134
    • 84899629980 scopus 로고    scopus 로고
    • Skeletal muscle mass in hospitalized elderly patients: Comparison of measurements by single-frequency BIA and DXA
    • Bosaeus I, Wilcox G, Rothenberg E, Strauss BJ,. Skeletal muscle mass in hospitalized elderly patients: comparison of measurements by single-frequency BIA and DXA. Clin Nutr. 2014; 33 (3): 426-431.
    • (2014) Clin Nutr , vol.33 , Issue.3 , pp. 426-431
    • Bosaeus, I.1    Wilcox, G.2    Rothenberg, E.3    Strauss, B.J.4
  • 135
    • 0035055321 scopus 로고    scopus 로고
    • Single prediction equation for bioelectrical impedance analysis in adults aged 20-94 years
    • Kyle UG, Genton L, Karsegard L, Slosman DO, Pichard C,. Single prediction equation for bioelectrical impedance analysis in adults aged 20-94 years. Nutrition. 2001; 17 (3): 248-253.
    • (2001) Nutrition , vol.17 , Issue.3 , pp. 248-253
    • Kyle, U.G.1    Genton, L.2    Karsegard, L.3    Slosman, D.O.4    Pichard, C.5
  • 136
    • 0036314279 scopus 로고    scopus 로고
    • Fat-free mass index and fat mass index percentiles in Caucasians aged 18-98 y
    • Schutz Y, Kyle UUG, Pichard C,. Fat-free mass index and fat mass index percentiles in Caucasians aged 18-98 y. Int J Obes Relat Metab Disord. 2002; 26 (7): 953-960.
    • (2002) Int J Obes Relat Metab Disord , vol.26 , Issue.7 , pp. 953-960
    • Schutz, Y.1    Kyle, U.U.G.2    Pichard, C.3
  • 137
    • 0033883484 scopus 로고    scopus 로고
    • Estimation of skeletal muscle mass by bioelectrical impedance analysis
    • Janssen I, Heymsfield SB, Baumgartner RN,. Estimation of skeletal muscle mass by bioelectrical impedance analysis. J Appl Physiol. 2000; 89: 465-471.
    • (2000) J Appl Physiol , vol.89 , pp. 465-471
    • Janssen, I.1    Heymsfield, S.B.2    Baumgartner, R.N.3
  • 138
    • 34347386393 scopus 로고    scopus 로고
    • Phase angle from bioelectrical impedance analysis: Population reference values by age, sex, and body mass index
    • Bosy-Westphal A, Danielzik S, Dorhofer R-P, Later W, Wiese S, Muller M,. Phase angle from bioelectrical impedance analysis: population reference values by age, sex, and body mass index. JPEN J Parenter Enteral Nutr. 2006; 30 (4): 309-316.
    • (2006) JPEN J Parenter Enteral Nutr , vol.30 , Issue.4 , pp. 309-316
    • Bosy-Westphal, A.1    Danielzik, S.2    Dorhofer, R.-P.3    Later, W.4    Wiese, S.5    Muller, M.6
  • 139
    • 23444457788 scopus 로고    scopus 로고
    • Bioelectrical impedance analysis: Population reference values for phase angle by age and sex
    • Barbosa-Silva MCG, Barros AJD, Wang J, Heymsfield SB, Pierson RN,. Bioelectrical impedance analysis: population reference values for phase angle by age and sex. Am J Clin Nutr. 2005; 82 (1): 49-52.
    • (2005) Am J Clin Nutr , vol.82 , Issue.1 , pp. 49-52
    • Barbosa-Silva, M.C.G.1    Barros, A.J.D.2    Wang, J.3    Heymsfield, S.B.4    Pierson, R.N.5
  • 140
    • 0025223809 scopus 로고
    • Height-normalized indices of the body'€™s fat-free mass and fat mass: Potentially useful indicators of nutritional status
    • VanItallie T, Yang M-U, Heymsfield S, Funk R, Boileau R,. Height-normalized indices of the body'€™s fat-free mass and fat mass: potentially useful indicators of nutritional status. Am J Clin Nutr. 1990; 52: 953-959.
    • (1990) Am J Clin Nutr , vol.52 , pp. 953-959
    • Vanitallie, T.1    Yang, M.-U.2    Heymsfield, S.3    Funk, R.4    Boileau, R.5
  • 141
    • 0037305892 scopus 로고    scopus 로고
    • Development of bioelectrical impedance analysis prediction equations for body composition with the use of a multicomponent model for use in epidemiologic surveys
    • Sun SS, Chumlea WC, Heymsfield SB,. Development of bioelectrical impedance analysis prediction equations for body composition with the use of a multicomponent model for use in epidemiologic surveys. Am J Clin Nutr. 2003; 77 (2): 331-340.
    • (2003) Am J Clin Nutr , vol.77 , Issue.2 , pp. 331-340
    • Sun, S.S.1    Chumlea, W.C.2    Heymsfield, S.B.3
  • 142
    • 0038045423 scopus 로고    scopus 로고
    • Body composition interpretation: Contributions of the fat-free mass index and the body fat mass index
    • Kyle UG, Schutz Y, Dupertuis YM, Pichard C,. Body composition interpretation: contributions of the fat-free mass index and the body fat mass index. Nutrition. 2003; 19 (7-8): 597-604.
    • (2003) Nutrition , vol.19 , Issue.7-8 , pp. 597-604
    • Kyle, U.G.1    Schutz, Y.2    Dupertuis, Y.M.3    Pichard, C.4
  • 143
    • 84866751873 scopus 로고    scopus 로고
    • Comparison between nutritional risk tools and parameters derived from bioelectrical impedance analysis with subjective global assessment
    • Meireles MS, Wazlawik E, Bastos JL, Garcia MF,. Comparison between nutritional risk tools and parameters derived from bioelectrical impedance analysis with subjective global assessment. J Acad Nutr Diet. 2012; 112 (10): 1543-1549.
    • (2012) J Acad Nutr Diet , vol.112 , Issue.10 , pp. 1543-1549
    • Meireles, M.S.1    Wazlawik, E.2    Bastos, J.L.3    Garcia, M.F.4
  • 144
    • 80055025464 scopus 로고    scopus 로고
    • The impact of low preoperative fat-free body mass on infections and length of stay after cardiac surgery: A prospective cohort study
    • Van Venrooij LM, de Vos R, Zijlstra E, Borgmeijer-Hoelen MM, van Leeuwen PA, de Mol BA,. The impact of low preoperative fat-free body mass on infections and length of stay after cardiac surgery: a prospective cohort study. J Thorac Cardiovasc Surg. 2011; 142 (5): 1263-1269.
    • (2011) J Thorac Cardiovasc Surg , vol.142 , Issue.5 , pp. 1263-1269
    • Van Venrooij, L.M.1    De Vos, R.2    Zijlstra, E.3    Borgmeijer-Hoelen, M.M.4    Van Leeuwen, P.A.5    De Mol, B.A.6
  • 145
  • 146
    • 0034078686 scopus 로고    scopus 로고
    • Assessment of intracellular water by whole body bioelectrical impedance and total body potassium in HIV-positive patients
    • Schwenk A, Eschner W, Kremer G, Ward LC,. Assessment of intracellular water by whole body bioelectrical impedance and total body potassium in HIV-positive patients. Clin Nutr. 2000; 19 (2): 109-113.
    • (2000) Clin Nutr , vol.19 , Issue.2 , pp. 109-113
    • Schwenk, A.1    Eschner, W.2    Kremer, G.3    Ward, L.C.4
  • 147
    • 0028915122 scopus 로고
    • Bioelectrical impedance analysis as a predictor of survival in patients with human immunodeficiency virus infection
    • Ott M, Fischer H, Polat H,. Bioelectrical impedance analysis as a predictor of survival in patients with human immunodeficiency virus infection. J Acquir Immune Defic Syndr Hum Retrovirol. 1995; 9: 20-25.
    • (1995) J Acquir Immune Defic Syndr Hum Retrovirol , vol.9 , pp. 20-25
    • Ott, M.1    Fischer, H.2    Polat, H.3
  • 148
    • 51249103843 scopus 로고    scopus 로고
    • Bioelectrical impedance phase angle as a prognostic indicator in breast cancer
    • Gupta D, Lammersfeld CA, Vashi PG,. Bioelectrical impedance phase angle as a prognostic indicator in breast cancer. BMC Cancer. 2008; 8: 249.
    • (2008) BMC Cancer , vol.8 , pp. 249
    • Gupta, D.1    Lammersfeld, C.A.2    Vashi, P.G.3
  • 149
    • 60749135297 scopus 로고    scopus 로고
    • Bioelectrical impedance phase angle in clinical practice: Implications for prognosis in stage IIIB and IV non-small cell lung cancer
    • Gupta D, Lammersfeld CA, Vashi PG,. Bioelectrical impedance phase angle in clinical practice: implications for prognosis in stage IIIB and IV non-small cell lung cancer. BMC Cancer. 2009; 9: 37.
    • (2009) BMC Cancer , vol.9 , pp. 37
    • Gupta, D.1    Lammersfeld, C.A.2    Vashi, P.G.3
  • 150
    • 11144288145 scopus 로고    scopus 로고
    • Bioelectrical impedance phase angle as a prognostic indicator in advanced pancreatic cancer
    • Gupta D, Lis CG, Dahlk SL, Vashi PG, Grutsch JF, Lammersfeld CA,. Bioelectrical impedance phase angle as a prognostic indicator in advanced pancreatic cancer. Br J Nutr. 2004; 92 (6): 957-962.
    • (2004) Br J Nutr , vol.92 , Issue.6 , pp. 957-962
    • Gupta, D.1    Lis, C.G.2    Dahlk, S.L.3    Vashi, P.G.4    Grutsch, J.F.5    Lammersfeld, C.A.6
  • 151
    • 48249104340 scopus 로고    scopus 로고
    • The relationship between bioelectrical impedance phase angle and subjective global assessment in advanced colorectal cancer
    • Gupta D, Lis CG, Dahlk SL,. The relationship between bioelectrical impedance phase angle and subjective global assessment in advanced colorectal cancer. Nutr J. 2008; 7 (1): 7-19.
    • (2008) Nutr J , vol.7 , Issue.1 , pp. 7-19
    • Gupta, D.1    Lis, C.G.2    Dahlk, S.L.3
  • 153
    • 0036550667 scopus 로고    scopus 로고
    • Norms and correlates of bioimpedance phase angle in healthy human subjects, hospitalized patients, and patients with liver cirrhosis
    • Selberg O, Selberg D,. Norms and correlates of bioimpedance phase angle in healthy human subjects, hospitalized patients, and patients with liver cirrhosis. Eur J Appl Physiol. 2002; 86: 509-516.
    • (2002) Eur J Appl Physiol , vol.86 , pp. 509-516
    • Selberg, O.1    Selberg, D.2
  • 154
    • 0029903409 scopus 로고    scopus 로고
    • Nutritional and prognostic correlates of bioimpedance indexes in hemodialysis patients
    • Maggiore Q, Nigrelli S, Ciccarelli C, Grimaldi C, Rossi GA, Michelassi C,. Nutritional and prognostic correlates of bioimpedance indexes in hemodialysis patients. Kidney Int. 1996; 50 (6): 2103-2108.
    • (1996) Kidney Int , vol.50 , Issue.6 , pp. 2103-2108
    • Maggiore, Q.1    Nigrelli, S.2    Ciccarelli, C.3    Grimaldi, C.4    Rossi, G.A.5    Michelassi, C.6
  • 155
    • 77957363381 scopus 로고    scopus 로고
    • Bioelectric impedance phase angle is associated with hospital mortality of geriatric patients
    • Wirth R, Volkert D, Rösler A, Sieber CC, Bauer JM,. Bioelectric impedance phase angle is associated with hospital mortality of geriatric patients. Arch Gerontol Geriatr. 2010; 51: 290-294.
    • (2010) Arch Gerontol Geriatr , vol.51 , pp. 290-294
    • Wirth, R.1    Volkert, D.2    Rösler, A.3    Sieber, C.C.4    Bauer, J.M.5
  • 156
    • 0344896644 scopus 로고    scopus 로고
    • Reliability and variability of bioimpedance measures in normal adults: Effects of age, gender, and body mass
    • Dittmar M,. Reliability and variability of bioimpedance measures in normal adults: effects of age, gender, and body mass. Am J Phys Anthropol. 2003; 122 (4): 361-370.
    • (2003) Am J Phys Anthropol , vol.122 , Issue.4 , pp. 361-370
    • Dittmar, M.1
  • 157
    • 0034930132 scopus 로고    scopus 로고
    • Fat-free and fat mass percentiles in 5225 healthy subjects aged 15 to 98 years
    • Kyle UG, Genton L, Slosman DO, Pichard C,. Fat-free and fat mass percentiles in 5225 healthy subjects aged 15 to 98 years. Nutrition. 2001; 17 (7-8): 534-541.
    • (2001) Nutrition , vol.17 , Issue.7-8 , pp. 534-541
    • Kyle, U.G.1    Genton, L.2    Slosman, D.O.3    Pichard, C.4
  • 158
    • 77956643014 scopus 로고    scopus 로고
    • Cutoff percentiles of bioelectrical phase angle predict functionality, quality of life, and mortality in patients with cancer
    • Norman K, Stoba N, Zocher D,. Cutoff percentiles of bioelectrical phase angle predict functionality, quality of life, and mortality in patients with cancer. J Clin Nutr. 2010; 92 (3): 612-619.
    • (2010) J Clin Nutr , vol.92 , Issue.3 , pp. 612-619
    • Norman, K.1    Stoba, N.2    Zocher, D.3
  • 160
    • 0028048393 scopus 로고
    • A new method for monitoring body fluid variation by bioimpedance analysis: The RXc graph
    • Piccoli A, Rossi B, Pillon L, Bucciante G,. A new method for monitoring body fluid variation by bioimpedance analysis: the RXc graph. Kidney Int. 1994; 46: 534-539.
    • (1994) Kidney Int , vol.46 , pp. 534-539
    • Piccoli, A.1    Rossi, B.2    Pillon, L.3    Bucciante, G.4
  • 161
    • 0027410827 scopus 로고
    • Improved prediction of extracellular and total body water using impedance loci generated by multiple frequency bioelectrical impedance analysis
    • Cornish BH, Thomas BJ, Ward LC,. Improved prediction of extracellular and total body water using impedance loci generated by multiple frequency bioelectrical impedance analysis. Phys Med Biol. 1993; 38: 337-346.
    • (1993) Phys Med Biol , vol.38 , pp. 337-346
    • Cornish, B.H.1    Thomas, B.J.2    Ward, L.C.3
  • 162
    • 13744251529 scopus 로고    scopus 로고
    • Comparison of multifrequency bioelectrical impedance analysis with dual-energy X-ray absorptiometry for assessment of percentage body fat in a large, healthy population
    • Sun G, French CR, Martin GR,. Comparison of multifrequency bioelectrical impedance analysis with dual-energy X-ray absorptiometry for assessment of percentage body fat in a large, healthy population. Am J Clin Nutr. 2005; 81 (1): 74-78.
    • (2005) Am J Clin Nutr , vol.81 , Issue.1 , pp. 74-78
    • Sun, G.1    French, C.R.2    Martin, G.R.3
  • 163
    • 0031008370 scopus 로고    scopus 로고
    • Validation of multifrequency bioelectrical impedance analysis in monitoring fluid balance in healthy elderly subjects
    • Olde Rikkert MG, Deurenberg P, Jansen RW, vantHof MA, Hoefnagels WH,. Validation of multifrequency bioelectrical impedance analysis in monitoring fluid balance in healthy elderly subjects. J Gerontol A Biol Sci Med Sci. 1997; 52 (3): M137-M141.
    • (1997) J Gerontol A Biol Sci Med Sci , vol.52 , Issue.3 , pp. M137-M141
    • Olde Rikkert, M.G.1    Deurenberg, P.2    Jansen, R.W.3    Vanthof, M.A.4    Hoefnagels, W.H.5
  • 164
    • 84876415157 scopus 로고    scopus 로고
    • Accuracy of segmental multi-frequency bioelectrical impedance analysis for assessing whole-body and appendicular fat mass and lean soft tissue mass in frail women aged 75 years and older
    • Kim M, Kim H,. Accuracy of segmental multi-frequency bioelectrical impedance analysis for assessing whole-body and appendicular fat mass and lean soft tissue mass in frail women aged 75 years and older. Eur J Clin Nutr. 2013; 67 (4): 395-400.
    • (2013) Eur J Clin Nutr , vol.67 , Issue.4 , pp. 395-400
    • Kim, M.1    Kim, H.2
  • 165
    • 0036143664 scopus 로고    scopus 로고
    • Evaluation of different methods for assessing intracellular fluid in healthy older people: A cross-validation study
    • Dittmar M, Reber H,. Evaluation of different methods for assessing intracellular fluid in healthy older people: a cross-validation study. J Am Geriatr Soc. 2002; 50 (1): 104-110.
    • (2002) J Am Geriatr Soc , vol.50 , Issue.1 , pp. 104-110
    • Dittmar, M.1    Reber, H.2
  • 166
    • 0028952999 scopus 로고
    • Multi-frequency impedance for the prediction of extracellular water and total body water
    • Deurenberg P, Tagliabue A, Schouten FJ,. Multi-frequency impedance for the prediction of extracellular water and total body water. Br J Nutr. 1995; 73 (3): 349-358.
    • (1995) Br J Nutr , vol.73 , Issue.3 , pp. 349-358
    • Deurenberg, P.1    Tagliabue, A.2    Schouten, F.J.3
  • 167
    • 84865161025 scopus 로고    scopus 로고
    • Utility of multifrequency bioelectrical impedance compared with dual-energy X-ray absorptiometry for assessment of total and regional body composition varies between men and women
    • Anderson LJ, Erceg DN, Schroeder ET,. Utility of multifrequency bioelectrical impedance compared with dual-energy X-ray absorptiometry for assessment of total and regional body composition varies between men and women. Nutr Res. 2012; 32 (7): 479-485.
    • (2012) Nutr Res , vol.32 , Issue.7 , pp. 479-485
    • Anderson, L.J.1    Erceg, D.N.2    Schroeder, E.T.3
  • 168
    • 0028881307 scopus 로고
    • Comparison of bio-impedance spectroscopy and multi-frequency bio-impedance analysis for the assessment of extracellular and total body water in surgical patients
    • Hannan WJ, Cowen SJ, Plester CE, Fearon KCH, DeBeau A,. Comparison of bio-impedance spectroscopy and multi-frequency bio-impedance analysis for the assessment of extracellular and total body water in surgical patients. Clin Sci. 1995; 89 (6): 651-658.
    • (1995) Clin Sci , vol.89 , Issue.6 , pp. 651-658
    • Hannan, W.J.1    Cowen, S.J.2    Plester, C.E.3    Fearon, K.C.H.4    DeBeau, A.5
  • 169
    • 0032080285 scopus 로고    scopus 로고
    • Proximal and distal measurements of extracellular and total body water by multi-frequency bio-impedance analysis in surgical patients
    • Hannan WJ, Cowen SJ, Plester C, Fearon KC,. Proximal and distal measurements of extracellular and total body water by multi-frequency bio-impedance analysis in surgical patients. Appl Radiat Isot. 1998; 49 (5-6): 621-622.
    • (1998) Appl Radiat Isot , vol.49 , Issue.5-6 , pp. 621-622
    • Hannan, W.J.1    Cowen, S.J.2    Plester, C.3    Fearon, K.C.4
  • 170
    • 0035142257 scopus 로고    scopus 로고
    • Estimation of body water compartments in cirrhosis by multiple-frequency bioelectrical-impedance analysis
    • Lehnert ME, Clarke DD, Gibbons JG,. Estimation of body water compartments in cirrhosis by multiple-frequency bioelectrical-impedance analysis. Nutrition. 2001; 17 (1): 31-34.
    • (2001) Nutrition , vol.17 , Issue.1 , pp. 31-34
    • Lehnert, M.E.1    Clarke, D.D.2    Gibbons, J.G.3
  • 171
    • 84927129694 scopus 로고    scopus 로고
    • Bioimpedance illness marker compared to phase angle as a predictor of malnutrition in hospitalised patients
    • (suppl 1)
    • Plank LD, Li A,. Bioimpedance illness marker compared to phase angle as a predictor of malnutrition in hospitalised patients. Clin Nutr. 2013; 32 (suppl 1): S85.
    • (2013) Clin Nutr , vol.32 , pp. S85
    • Plank, L.D.1    Li, A.2
  • 172
    • 84927131661 scopus 로고    scopus 로고
    • Impedance ratio Z200/Z5 compared to phase angle at 50 kHz better predicts nutritional status and length of stay in hospitalized patients
    • Earthman CP, Kruizenga HM, Weijs PJM,. Impedance ratio Z200/Z5 compared to phase angle at 50 kHz better predicts nutritional status and length of stay in hospitalized patients. Int J Obes. 2011; 35 (2): S58.
    • (2011) Int J Obes , vol.35 , Issue.2 , pp. S58
    • Earthman, C.P.1    Kruizenga, H.M.2    Weijs, P.J.M.3
  • 173
    • 33645050901 scopus 로고    scopus 로고
    • Impact of oedema on recovery after major abdominal surgery and potential value of multifrequency bioimpedance measurements
    • Itobi E, Stroud M, Elia M,. Impact of oedema on recovery after major abdominal surgery and potential value of multifrequency bioimpedance measurements. Br J Surg. 2006; 93 (3): 354-361.
    • (2006) Br J Surg , vol.93 , Issue.3 , pp. 354-361
    • Itobi, E.1    Stroud, M.2    Elia, M.3
  • 174
    • 84879976595 scopus 로고    scopus 로고
    • Low albumin levels and high impedance ratio as risk factors for worsening kidney function during hospitalization of decompensated heart failure patients
    • Valdespino-Trejo A, Orea-Tejeda A, Castillo-Martínez L,. Low albumin levels and high impedance ratio as risk factors for worsening kidney function during hospitalization of decompensated heart failure patients. Exp Clin Cardiol. 2013; 18 (2): 113-117.
    • (2013) Exp Clin Cardiol , vol.18 , Issue.2 , pp. 113-117
    • Valdespino-Trejo, A.1    Orea-Tejeda, A.2    Castillo-Martínez, L.3
  • 175
    • 34247624484 scopus 로고    scopus 로고
    • Bioelectrical impedance and strength measurements in patients with heart failure: Comparison with functional class
    • Castillo Martínez L, Colín Ramírez E, Orea Tejeda A,. Bioelectrical impedance and strength measurements in patients with heart failure: comparison with functional class. Nutrition. 2007; 23 (5): 412-418.
    • (2007) Nutrition , vol.23 , Issue.5 , pp. 412-418
    • Castillo Martínez, L.1    Colín Ramírez, E.2    Orea Tejeda, A.3
  • 176
    • 0030922764 scopus 로고    scopus 로고
    • Predicting body cell mass with bioimpedance by using theoretical methods: A technological review
    • De Lorenzo A, Andreoli A, Matthie J, Withers P,. Predicting body cell mass with bioimpedance by using theoretical methods: a technological review. J Appl Physiol. 1997; 82 (5): 1542-1558.
    • (1997) J Appl Physiol , vol.82 , Issue.5 , pp. 1542-1558
    • De Lorenzo, A.1    Andreoli, A.2    Matthie, J.3    Withers, P.4
  • 178
    • 0002196509 scopus 로고    scopus 로고
    • Electrical properties of emulsions
    • In: ed. London, UK: Academic Press
    • Hanai T,. Electrical properties of emulsions. In: Sherman PH, ed. Emulsion Science. London, UK: Academic Press; 1968: 354-377.
    • Emulsion Science , vol.1968 , pp. 354-377
    • Hanai, T.1    Sherman, P.H.2
  • 179
    • 23044470007 scopus 로고    scopus 로고
    • Second generation mixture theory equation for estimating intracellular water using bioimpedance spectroscopy
    • Matthie JR., Second generation mixture theory equation for estimating intracellular water using bioimpedance spectroscopy. J Appl Physiol. 2005; 99 (2): 780-781.
    • (2005) J Appl Physiol , vol.99 , Issue.2 , pp. 780-781
    • Matthie, J.R.1
  • 180
    • 0031661274 scopus 로고    scopus 로고
    • Human hydrometry: Comparison of multifrequency bioelectrical impedance with 2H2O and bromine dilution
    • Ellis KJ, Wong WW,. Human hydrometry: comparison of multifrequency bioelectrical impedance with 2H2O and bromine dilution. J Appl Physiol. 1998; 85 (3): 1056-1062.
    • (1998) J Appl Physiol , vol.85 , Issue.3 , pp. 1056-1062
    • Ellis, K.J.1    Wong, W.W.2
  • 181
    • 0032080105 scopus 로고    scopus 로고
    • Evaluation of multifrequency bioimpedance spectroscopy for measurement of the extracellular water space in critically ill patients
    • Plank LD, Monk DN, Woollard G, Hill GL,. Evaluation of multifrequency bioimpedance spectroscopy for measurement of the extracellular water space in critically ill patients. Appl Radiat Isot. 1998; 49 (5-6): 481-483.
    • (1998) Appl Radiat Isot , vol.49 , Issue.5-6 , pp. 481-483
    • Plank, L.D.1    Monk, D.N.2    Woollard, G.3    Hill, G.L.4
  • 182
    • 33746557390 scopus 로고    scopus 로고
    • Body fluid volume determination via body composition spectroscopy in health and disease
    • Moissl UM, Wabel P, Chamney PW,. Body fluid volume determination via body composition spectroscopy in health and disease. Physiol Meas. 2006; 27 (9): 921-933.
    • (2006) Physiol Meas , vol.27 , Issue.9 , pp. 921-933
    • Moissl, U.M.1    Wabel, P.2    Chamney, P.W.3
  • 183
    • 33846092266 scopus 로고    scopus 로고
    • A whole-body model to distinguish excess fluid from the hydration of major body tissues
    • Chamney PW, Wabel P, Moissl UM,. A whole-body model to distinguish excess fluid from the hydration of major body tissues. Am J Clin Nutr. 2007; 85 (1): 80-89.
    • (2007) Am J Clin Nutr , vol.85 , Issue.1 , pp. 80-89
    • Chamney, P.W.1    Wabel, P.2    Moissl, U.M.3
  • 184
    • 58849150742 scopus 로고    scopus 로고
    • Importance of whole-body bioimpedance spectroscopy for the management of fluid balance
    • Wabel P, Chamney P, Moissl U, Jirka T,. Importance of whole-body bioimpedance spectroscopy for the management of fluid balance. Blood Purif. 2009; 27 (1): 75-80.
    • (2009) Blood Purif , vol.27 , Issue.1 , pp. 75-80
    • Wabel, P.1    Chamney, P.2    Moissl, U.3    Jirka, T.4
  • 185
    • 84936856233 scopus 로고    scopus 로고
    • Body composition and survival in dialysis patients: Results from an international cohort study [published online April 21, 2015]
    • Marcelli D, Usvyat L a., Kotanko P,. Body composition and survival in dialysis patients: results from an international cohort study [published online April 21, 2015]. Clin J Am Soc Nephrol.
    • Clin J Am Soc Nephrol
    • Marcelli, D.1    Kotanko, P.2
  • 187
    • 0036369371 scopus 로고    scopus 로고
    • Ultrasound of muscles
    • Peetrons P,. Ultrasound of muscles. Eur Radiol. 2002; 12: 35-43.
    • (2002) Eur Radiol , vol.12 , pp. 35-43
    • Peetrons, P.1
  • 188
    • 33748450279 scopus 로고    scopus 로고
    • Measurement of muscle thickness as quantitative muscle evaluation for adults with severe cerebral palsy
    • Ohata K, Tsuboyama T, Ichihashi N, Minami S,. Measurement of muscle thickness as quantitative muscle evaluation for adults with severe cerebral palsy. Phys Ther. 2006; 86 (9): 1231-1239.
    • (2006) Phys Ther , vol.86 , Issue.9 , pp. 1231-1239
    • Ohata, K.1    Tsuboyama, T.2    Ichihashi, N.3    Minami, S.4
  • 189
    • 0029103190 scopus 로고
    • Muscle thickness, measured with ultrasound, may be an indicator of lean tissue wasting in multiple organ failure in the presence of edema
    • Campbell IT, Watt T, Withers D,. Muscle thickness, measured with ultrasound, may be an indicator of lean tissue wasting in multiple organ failure in the presence of edema. Am J Clin Nutr. 1995; 62: 533-539.
    • (1995) Am J Clin Nutr , vol.62 , pp. 533-539
    • Campbell, I.T.1    Watt, T.2    Withers, D.3
  • 190
    • 41349122451 scopus 로고    scopus 로고
    • Muscle wasting in intensive care patients: Ultrasound observation of the M. Quadriceps femoris muscle layer
    • Gruther W, Benesch T, Zorn C,. Muscle wasting in intensive care patients: ultrasound observation of the M. quadriceps femoris muscle layer. J Rehabil Med. 2008; 40 (3): 185-189.
    • (2008) J Rehabil Med , vol.40 , Issue.3 , pp. 185-189
    • Gruther, W.1    Benesch, T.2    Zorn, C.3
  • 191
    • 84969371910 scopus 로고    scopus 로고
    • An analysis of reliability and accuracy of muscle thickness ultrasonography in critically ill children and adults [published online March 9, 2015]
    • Fivez T, Hendrickx a, Van Herpe T,. An analysis of reliability and accuracy of muscle thickness ultrasonography in critically ill children and adults [published online March 9, 2015]. JPEN J Parenter Enteral Nutr.
    • JPEN J Parenter Enteral Nutr
    • Fivez, T.1    Hendrickx, A.2    Van Herpe, T.3
  • 192
    • 78649718977 scopus 로고    scopus 로고
    • Structure to function: Muscle failure in critically ill patients
    • Puthucheary Z, Montgomery H, Moxham J, Harridge S, Hart N,. Structure to function: muscle failure in critically ill patients. J Physiol. 2010; 588: 4641-4648.
    • (2010) J Physiol , vol.588 , pp. 4641-4648
    • Puthucheary, Z.1    Montgomery, H.2    Moxham, J.3    Harridge, S.4    Hart, N.5
  • 193
    • 84922660984 scopus 로고    scopus 로고
    • Validity of ultrasound prediction equations for total and regional muscularity in middle-aged and older men and women
    • Abe T, Loenneke JP, Young KC,. Validity of ultrasound prediction equations for total and regional muscularity in middle-aged and older men and women. Ultrasound Med Biol. 2015; 41 (2): 557-564.
    • (2015) Ultrasound Med Biol , vol.41 , Issue.2 , pp. 557-564
    • Abe, T.1    Loenneke, J.P.2    Young, K.C.3
  • 194
    • 84995202143 scopus 로고
    • Prediction equations for body composition of Japanese adults by B-mode ultrasound
    • Abe T, Kondo M, Kawakami Y, Fukunaga T,. Prediction equations for body composition of Japanese adults by B-mode ultrasound. Am J Hum Biol. 1994; 6: 161-170.
    • (1994) Am J Hum Biol , vol.6 , pp. 161-170
    • Abe, T.1    Kondo, M.2    Kawakami, Y.3    Fukunaga, T.4
  • 195
    • 84905711216 scopus 로고    scopus 로고
    • Applicability of ultrasound muscle thickness measurements for predicting fat-free mass in elderly population
    • Takai Y, Ohta M, Akagi R,. Applicability of ultrasound muscle thickness measurements for predicting fat-free mass in elderly population. J Nutr Heal Aging. 2014; 18 (6): 579-585.
    • (2014) J Nutr Heal Aging , vol.18 , Issue.6 , pp. 579-585
    • Takai, Y.1    Ohta, M.2    Akagi, R.3
  • 196
    • 29544443907 scopus 로고    scopus 로고
    • Prediction and validation of total and regional skeletal muscle mass by ultrasound in Japanese adults
    • Sanada K, Kearns CF, Midorikawa T, Abe T,. Prediction and validation of total and regional skeletal muscle mass by ultrasound in Japanese adults. Eur J Appl Physiol. 2006; 96 (1): 24-31.
    • (2006) Eur J Appl Physiol , vol.96 , Issue.1 , pp. 24-31
    • Sanada, K.1    Kearns, C.F.2    Midorikawa, T.3    Abe, T.4
  • 197
    • 84897530614 scopus 로고    scopus 로고
    • Relationship between dual-relationship between dual-energy X-ray absorptiometry-derived appendicular lean tissue mass and total body skeletal muscle mass estimated by ultrasound
    • Abe T, Dabbs NC, Nahar VK, Ford MA, Bass MA, Loftin M,. Relationship between dual-relationship between dual-energy X-ray absorptiometry-derived appendicular lean tissue mass and total body skeletal muscle mass estimated by ultrasound. Int J Clin Med. 2013; 4: 283-286.
    • (2013) Int J Clin Med , vol.4 , pp. 283-286
    • Abe, T.1    Dabbs, N.C.2    Nahar, V.K.3    Ford, M.A.4    Bass, M.A.5    Loftin, M.6
  • 198
    • 84906099280 scopus 로고    scopus 로고
    • Bedside ultrasound measurement of skeletal muscle
    • Mourtzakis M, Wischmeyer P,. Bedside ultrasound measurement of skeletal muscle. Curr Opin Clin Nutr Metab Care. 2014; 17 (5): 389-395.
    • (2014) Curr Opin Clin Nutr Metab Care , vol.17 , Issue.5 , pp. 389-395
    • Mourtzakis, M.1    Wischmeyer, P.2
  • 199
    • 84855738689 scopus 로고    scopus 로고
    • Neuromuscular ultrasonography: Quantifying muscle and nerve measurements
    • Mayans D, Cartwright MS, Walker FO,. Neuromuscular ultrasonography: quantifying muscle and nerve measurements. Phys Med Rehabil Clin N Am. 2012; 23: 133-148.
    • (2012) Phys Med Rehabil Clin N Am , vol.23 , pp. 133-148
    • Mayans, D.1    Cartwright, M.S.2    Walker, F.O.3
  • 200
    • 67649213565 scopus 로고    scopus 로고
    • Quantification of muscle volume by echography: Comparison with MRI data on subjects in long-term bed rest
    • Arbeille P, Kerbeci P, Capri A, Dannaud C, Trappe SW, Trappe TA,. Quantification of muscle volume by echography: comparison with MRI data on subjects in long-term bed rest. Ultrasound Med Biol. 2009; 35 (7): 1092-1097.
    • (2009) Ultrasound Med Biol , vol.35 , Issue.7 , pp. 1092-1097
    • Arbeille, P.1    Kerbeci, P.2    Capri, A.3    Dannaud, C.4    Trappe, S.W.5    Trappe, T.A.6
  • 201
    • 84981210373 scopus 로고    scopus 로고
    • Ultrasound assessment of hamstring muscle size using posterior thigh muscle thickness [published online November 3, 2014]
    • Abe T, Loenneke JP, Thiebaud RS,. Ultrasound assessment of hamstring muscle size using posterior thigh muscle thickness [published online November 3, 2014]. Clin Physiol Funct Imaging.
    • Clin Physiol Funct Imaging
    • Abe, T.1    Loenneke, J.P.2    Thiebaud, R.S.3
  • 202
    • 79958803320 scopus 로고    scopus 로고
    • Comparison of ultrasound-measured age-related, site-specific muscle loss between healthy Japanese and German men
    • Abe T, Kawakami Y, Kondo M, Fukunaga T., Comparison of ultrasound-measured age-related, site-specific muscle loss between healthy Japanese and German men. Clin Physiol Funct Imaging. 2011; 31: 320-325.
    • (2011) Clin Physiol Funct Imaging , vol.31 , pp. 320-325
    • Abe, T.1    Kawakami, Y.2    Kondo, M.3    Fukunaga, T.4
  • 203
    • 66049143918 scopus 로고    scopus 로고
    • Ultrasound measurement of rectus femoris cross-sectional area and the relationship with quadriceps strength in COPD
    • Seymour JM, Ward K, Sidhu PS,. Ultrasound measurement of rectus femoris cross-sectional area and the relationship with quadriceps strength in COPD. Thorax. 2009; 64 (5): 418-423.
    • (2009) Thorax , vol.64 , Issue.5 , pp. 418-423
    • Seymour, J.M.1    Ward, K.2    Sidhu, P.S.3
  • 204
    • 80052969228 scopus 로고    scopus 로고
    • Ultrasound method for estimating the cross-sectional area of the psoas major muscle
    • Takai Y, Katsumata Y, Kawakami Y, Kanehisa H, Fukunaga T,. Ultrasound method for estimating the cross-sectional area of the psoas major muscle. Med Sci Sports Exerc. 2011; 43: 2000-2004.
    • (2011) Med Sci Sports Exerc , vol.43 , pp. 2000-2004
    • Takai, Y.1    Katsumata, Y.2    Kawakami, Y.3    Kanehisa, H.4    Fukunaga, T.5
  • 205
    • 84921055061 scopus 로고    scopus 로고
    • Bedside ultrasound is a practical and reliable measurement tool for assessing quadriceps muscle layer thickness
    • Tillquist M, Kutsogiannis DJ, Wischmeyer PE,. Bedside ultrasound is a practical and reliable measurement tool for assessing quadriceps muscle layer thickness. JPEN J Parenter Enteral Nutr. 2013; 38 (7): 886-890.
    • (2013) JPEN J Parenter Enteral Nutr , vol.38 , Issue.7 , pp. 886-890
    • Tillquist, M.1    Kutsogiannis, D.J.2    Wischmeyer, P.E.3
  • 206
    • 80053184391 scopus 로고    scopus 로고
    • Technical considerations for accurate measurement of subcutaneous adipose tissue thickness using B-mode ultrasound
    • Toomey C, McCreesh K, Leahy S, Jakeman P,. Technical considerations for accurate measurement of subcutaneous adipose tissue thickness using B-mode ultrasound. Ultrasound. 2011; 19 (2): 91-96.
    • (2011) Ultrasound , vol.19 , Issue.2 , pp. 91-96
    • Toomey, C.1    McCreesh, K.2    Leahy, S.3    Jakeman, P.4
  • 207
    • 84939609170 scopus 로고    scopus 로고
    • Heyland D,. Clinical evaluation research unit. 2015. http://www.criticalcarenutrition.com/index.php?option=com-content&view=article&id=182&Itemid=79. Accessed April 23, 2015.
    • (2015) Clinical Evaluation Research Unit
    • Heyland, D.1
  • 208
    • 84939642769 scopus 로고    scopus 로고
    • Value of multifrequency bioelectrical impedance in assessing fluid disturbances in patients undergoing major abdominal surgery
    • Itobi E, Stroud M, Elia M,. Value of multifrequency bioelectrical impedance in assessing fluid disturbances in patients undergoing major abdominal surgery. Eur J Gastroenterol Hepatol. 1997; 9 (8): 9-10.
    • (1997) Eur J Gastroenterol Hepatol , vol.9 , Issue.8 , pp. 9-10
    • Itobi, E.1    Stroud, M.2    Elia, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.