Volumn 67, Issue , 2013, Pages S10-S13

Bioelectrical impedance validation studies: Alternative approaches to their interpretation

Author keywords

Error grids; Impedance analysis; Limits of agreement; Reference method precision

Indexed keywords

ANALYTIC METHOD; ARTICLE; BIOELECTRICAL IMPEDANCE ANALYSIS; BIOENERGY; BODY COMPOSITION; BODY FAT; BODY HEIGHT; BODY MASS; BODY WEIGHT; CONTROLLED STUDY; DUAL ENERGY X RAY ABSORPTIOMETRY; ELECTROCHEMICAL IMPEDANCE SPECTROSCOPY; HUMAN; INTERMETHOD COMPARISON; MEDICAL RESEARCH; OUTCOME ASSESSMENT; VALIDATION STUDY;

EID: 84872139093     PISSN: 09543007     EISSN: 14765640     Source Type: Journal    
DOI: 10.1038/ejcn.2012.159     Document Type: Article
Times cited : (10)

References (27)
  • 4
    • 0027374930 scopus 로고
    • Techniques for the measurement of body composition: A practical guide
    • Jebb SA, Elia M. Techniques for the measurement of body composition: a practical guide. Int J Obes Relat Metab Disor 1993; 17: 611-621.
    • (1993) Int J Obes Relat Metab Disor , vol.17 , pp. 611-621
    • Jebb, S.A.1    Elia, M.2
  • 5
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; 1: 307-310.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 6
    • 0036347504 scopus 로고    scopus 로고
    • Body composition, as assessed by bioelectrical impedance spectroscopy and dual-energy X-ray absorptiometry, in a healthy paediatric population
    • Fors H, Gelander L, Bjarnason R, Albertsson-Wikland K, Bosaeus I. Body composition, as assessed by bioelectrical impedance spectroscopy and dual-energy X-ray absorptiometry, in a healthy paediatric population. Acta Paediatr 2002; 91: 755-760.
    • (2002) Acta Paediatr , vol.91 , pp. 755-760
    • Fors, H.1    Gelander, L.2    Bjarnason, R.3    Albertsson-Wikland, K.4    Bosaeus, I.5
  • 7
    • 52249084563 scopus 로고    scopus 로고
    • Is bioelectrical impedance accurate for use in large epidemiological studies?
    • Dehghan M, Merchant AT. Is bioelectrical impedance accurate for use in large epidemiological studies? Nutr J 2008; 7: 26-32.
    • (2008) Nutr J , vol.7 , pp. 26-32
    • Dehghan, M.1    Merchant, A.T.2
  • 8
    • 0742289640 scopus 로고    scopus 로고
    • Evaluation of foot-to-foot bioelectrical impedance analysis for the prediction of total body water in oncology outpatients receiving radiotherapy
    • Isenring E, Bauer J, Capra S, Davies PS. Evaluation of foot-to-foot bioelectrical impedance analysis for the prediction of total body water in oncology outpatients receiving radiotherapy. Eur J Clin Nutr 2004; 58: 46-51.
    • (2004) Eur J Clin Nutr , vol.58 , pp. 46-51
    • Isenring, E.1    Bauer, J.2    Capra, S.3    Davies, P.S.4
  • 9
    • 0033003166 scopus 로고    scopus 로고
    • A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques
    • Critchley LA, Critchley JA. A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques. J Clin Monit Comput 1999; 15: 85-91.
    • (1999) J Clin Monit Comput , vol.15 , pp. 85-91
    • Critchley, L.A.1    Critchley, J.A.2
  • 10
    • 68849121782 scopus 로고    scopus 로고
    • Bench-to-bedside review: The importance of the precision of the reference technique in method comparison studies--with specific reference to the measurement of cardiac output
    • Cecconi M, Rhodes A, Poloniecki J, Della Rocca G, Grounds RM. Bench-to-bedside review: the importance of the precision of the reference technique in method comparison studies--with specific reference to the measurement of cardiac output. Crit Care 2009; 13: 201-206.
    • (2009) Crit Care , vol.13 , pp. 201-206
    • Cecconi, M.1    Rhodes, A.2    Poloniecki, J.3    Della Rocca, G.4    Grounds, R.M.5
  • 11
    • 0027410827 scopus 로고
    • Improved prediction of extracellular and total body water using impedance loci generated by multiple frequency bioelectrical impedance analysis
    • Cornish BH, Thomas BJ, Ward LC. Improved prediction of extracellular and total body water using impedance loci generated by multiple frequency bioelectrical impedance analysis. Phys Med Biol 1993; 38: 337-346.
    • (1993) Phys Med Biol , vol.38 , pp. 337-346
    • Cornish, B.H.1    Thomas, B.J.2    Ward, L.C.3
  • 12
    • 0030922764 scopus 로고    scopus 로고
    • Predicting body cell mass with bioimpedance by using theoretical methods: A technological review
    • De Lorenzo A, Andreoli A, Matthie J, Withers P. Predicting body cell mass with bioimpedance by using theoretical methods: a technological review. J Appl Physiol 1997; 82: 1542-1558.
    • (1997) J Appl Physiol , vol.82 , pp. 1542-1558
    • De Lorenzo, A.1    Reoli, A.2    Matthie, J.3    Withers, P.4
  • 13
    • 19744364550 scopus 로고    scopus 로고
    • AACB Uncertainty of measurement working group. Uncertainty of measurement in quantitative medical testing. A laboratory implementation guide
    • White GH, Farrance I. AACB Uncertainty of measurement working group. Uncertainty of measurement in quantitative medical testing. A laboratory implementation guide. Clin Biochem Rev 2004; 25: S1-S24.
    • (2004) Clin Biochem Rev , vol.25 , pp. S1-S24
    • White, G.H.1    Farrance, I.2
  • 14
    • 70449646306 scopus 로고    scopus 로고
    • Noninvasive cardiac output and blood pressure monitoring cannot replace an invasive monitoring system in critically ill patients
    • Stover JF, Stocker R, Lenherr R, Neff TA, Cottini SR, Zoller B et al. Noninvasive cardiac output and blood pressure monitoring cannot replace an invasive monitoring system in critically ill patients. BMC Anesthesiol 2009; 9: 6-10.
    • (2009) BMC Anesthesiol , vol.9 , pp. 6-10
    • Stover, J.F.1    Stocker, R.2    Lenherr, R.3    Neff, T.A.4    Cottini, S.R.5    Zoller, B.6
  • 16
    • 77950845525 scopus 로고    scopus 로고
    • Accuracy of DXA in estimating body composition changes in elite athletes using a four compartment model as the reference method
    • Santos DA, Silva AM, Matias CN, Fields DA, Heymsfield SB, Sardinha LB. Accuracy of DXA in estimating body composition changes in elite athletes using a four compartment model as the reference method. Nutr Metab (Lond) 2010; 7: 22-30.
    • (2010) Nutr Metab (Lond) , vol.7 , pp. 22-30
    • Santos, D.A.1    Silva, A.M.2    Matias, C.N.3    Fields, D.A.4    Heymsfield, S.B.5    Sardinha, L.B.6
  • 18
    • 0002317811 scopus 로고    scopus 로고
    • Dual energy X-ray Absorptiometry
    • Roche AF, Heymsfield SB, Lohman TG, Human Kinetics: Champaign, IL
    • Lohman TG. Dual energy X-ray Absorptiometry. In: Roche AF, Heymsfield SB, Lohman TG (eds). Human Body Composition. Human Kinetics: Champaign, IL, 1996, pp 63-78.
    • (1996) Human Body Composition , pp. 63-78
    • Lohman, T.G.1
  • 19
    • 0142062027 scopus 로고    scopus 로고
    • Validity of six field and laboratory methods for measurement of body composition in boys
    • Parker L, Reilly JJ, Slater C, Wells JC, Pitsiladis Y. Validity of six field and laboratory methods for measurement of body composition in boys. Obes Res 2003; 11: 852-858.
    • (2003) Obes Res , vol.11 , pp. 852-858
    • Parker, L.1    Reilly, J.J.2    Slater, C.3    Wells, J.C.4    Pitsiladis, Y.5
  • 20
    • 0036271429 scopus 로고    scopus 로고
    • Setting performance goals and evaluating total analytical error for diagnostic assays
    • Krouwer JS. Setting performance goals and evaluating total analytical error for diagnostic assays. Clin Chem 2002; 48: 919-927.
    • (2002) Clin Chem , vol.48 , pp. 919-927
    • Krouwer, J.S.1
  • 21
    • 77951733801 scopus 로고    scopus 로고
    • A review of standards and statistics used to describe blood glucose monitor performance
    • Krouwer JS, Cembrowski GS. A review of standards and statistics used to describe blood glucose monitor performance. J Diabetes Sci Technol 2010; 4: 75-83.
    • (2010) J Diabetes Sci Technol , vol.4 , pp. 75-83
    • Krouwer, J.S.1    Cembrowski, G.S.2
  • 24
    • 0028851809 scopus 로고
    • Physical status: The use and interpretation of anthropometry. Report of a WHO Expert Committee
    • World Health Organization: Geneva
    • World Health Organisation. Physical status: the use and interpretation of anthropometry. Report of a WHO Expert Committee. WHO Technical Report Series 854. World Health Organization: Geneva, 1995.
    • (1995) WHO Technical Report Series , vol.854
  • 25
    • 77957341769 scopus 로고    scopus 로고
    • The relationship between BMI and percent body fat, measured by bioelectrical impedance, in a large adult sample is curvilinear and influenced by age and sex
    • Meeuwsen S, Horgan GW, Elia M. The relationship between BMI and percent body fat, measured by bioelectrical impedance, in a large adult sample is curvilinear and influenced by age and sex. Clin Nutr 2010; 29: 560-566.
    • (2010) Clin Nutr , vol.29 , pp. 560-566
    • Meeuwsen, S.1    Horgan, G.W.2    Elia, M.3
  • 26
    • 58949097009 scopus 로고    scopus 로고
    • Is body mass index really the best measure of obesity in individuals?
    • Green DJ. Is body mass index really the best measure of obesity in individuals? J Am Coll Cardiol 2009; 53: 526.
    • (2009) J am Coll Cardiol , vol.53 , pp. 526
    • Green, D.J.1
  • 27
    • 84859224327 scopus 로고    scopus 로고
    • Measuring adiposity in patients: The utility of body mass index (BMI), percent body fat, and leptin
    • Shah NR, Braverman ER. Measuring adiposity in patients: the utility of body mass index (BMI), percent body fat, and leptin. PLoS One 2012; 7: e33308.
    • (2012) Plos One , vol.7
    • Shah, N.R.1    Braverman, E.R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.