메뉴 건너뛰기




Volumn 74, Issue 2, 2015, Pages 346-352

Feasibility of human lung ventilation imaging using highly polarized naturally abundant xenon and optimized three-dimensional steady-state free precession

Author keywords

3D steady state free precession; hyperpolarized gas; lung ventilation imaging; naturally abundant xenon 129

Indexed keywords

BIOLOGICAL ORGANS; IMAGE ENHANCEMENT; MAGNETIC RESONANCE IMAGING; OPTICAL PUMPING; SMOKE; XENON;

EID: 84937735823     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.25732     Document Type: Article
Times cited : (57)

References (38)
  • 2
    • 73249132982 scopus 로고    scopus 로고
    • Hyperpolarised 3He MRI versus HRCT in COPD and normal volunteers: PHIL trial
    • Van Beek EJR, Dahmen AM, Stavngaard T, et al., Hyperpolarised 3He MRI versus HRCT in COPD and normal volunteers: PHIL trial. Eur Respir J 2009; 34: 1311-1321.
    • (2009) Eur Respir J , vol.34 , pp. 1311-1321
    • Van Beek, E.J.R.1    Dahmen, A.M.2    Stavngaard, T.3
  • 4
    • 77950396804 scopus 로고    scopus 로고
    • Hyperpolarized 3He MR for sensitive imaging of ventilation function and treatment efficiency in young cystic fibrosis patients with normal lung function
    • Bannier E, Cieslar K, Mosbah K, Aubert F, Duboeuf F, Salhi Z, Gaillard S, Berthezène Y, Crémillieux Y, Reix P,. Hyperpolarized 3He MR for sensitive imaging of ventilation function and treatment efficiency in young cystic fibrosis patients with normal lung function. Radiology 2010; 255: 225-232.
    • (2010) Radiology , vol.255 , pp. 225-232
    • Bannier, E.1    Cieslar, K.2    Mosbah, K.3    Aubert, F.4    Duboeuf, F.5    Salhi, Z.6    Gaillard, S.7    Berthezène, Y.8    Crémillieux, Y.9    Reix, P.10
  • 5
    • 84863397729 scopus 로고    scopus 로고
    • Direct visualisation of collateral ventilation in COPD with hyperpolarised gas MRI
    • Marshall H, Deppe MH, Parra-Robles J, et al., Direct visualisation of collateral ventilation in COPD with hyperpolarised gas MRI. Thorax 2012; 67: 613-617.
    • (2012) Thorax , vol.67 , pp. 613-617
    • Marshall, H.1    Deppe, M.H.2    Parra-Robles, J.3
  • 6
    • 84867910322 scopus 로고    scopus 로고
    • Hyperpolarized 3He and 129Xe MR imaging in healthy volunteers and patients with chronic obstructive pulmonary disease
    • Kirby M, Svenningsen S, Owrangi A, et al., Hyperpolarized 3He and 129Xe MR imaging in healthy volunteers and patients with chronic obstructive pulmonary disease. Radiology 2012; 265: 600-610.
    • (2012) Radiology , vol.265 , pp. 600-610
    • Kirby, M.1    Svenningsen, S.2    Owrangi, A.3
  • 9
    • 84872943964 scopus 로고    scopus 로고
    • Hyperpolarized 129Xe MRI of the human lung
    • Mugler JP III, Altes TA,. Hyperpolarized 129Xe MRI of the human lung. J Magn Reson Imaging 2013; 37: 313-331.
    • (2013) J Magn Reson Imaging , vol.37 , pp. 313-331
    • Mugler, J.P.1    Altes, T.A.2
  • 13
    • 43249093673 scopus 로고    scopus 로고
    • Large production system for hyperpolarized 129Xe for human lung imaging studies
    • Hersman FW, Ruset IC, Ketel S, et al., Large production system for hyperpolarized 129Xe for human lung imaging studies. Acad Radiol 2008; 15: 683-692.
    • (2008) Acad Radiol , vol.15 , pp. 683-692
    • Hersman, F.W.1    Ruset, I.C.2    Ketel, S.3
  • 14
    • 84883373676 scopus 로고    scopus 로고
    • Near-unity nuclear polarization with an open-source 129Xe hyperpolarizer for NMR and MRI
    • Nikolaou P, Coffey AM, Walkup LL, et al., Near-unity nuclear polarization with an open-source 129Xe hyperpolarizer for NMR and MRI. Proc Natl Acad Sci U S A 2013; 110: 14150-14155.
    • (2013) Proc Natl Acad Sci U S A , vol.110 , pp. 14150-14155
    • Nikolaou, P.1    Coffey, A.M.2    Walkup, L.L.3
  • 15
    • 84873674849 scopus 로고    scopus 로고
    • Optimized production of hyperpolarized 129Xe at 2 bars for in vivo lung magnetic resonance imaging
    • Norquay G, Parnell SR, Xu X, Parra-Robles J, Wild JM,. Optimized production of hyperpolarized 129Xe at 2 bars for in vivo lung magnetic resonance imaging. J Appl Phys 2013; 113: 044908-044909.
    • (2013) J Appl Phys , vol.113 , pp. 044908-044909
    • Norquay, G.1    Parnell, S.R.2    Xu, X.3    Parra-Robles, J.4    Wild, J.M.5
  • 16
    • 84861227899 scopus 로고    scopus 로고
    • Variable flip angle schedules in bSSFP imaging of hyperpolarized noble gases
    • Deppe MH, Wild JM,. Variable flip angle schedules in bSSFP imaging of hyperpolarized noble gases. Magn Reson Med 2012; 67: 1656-1664.
    • (2012) Magn Reson Med , vol.67 , pp. 1656-1664
    • Deppe, M.H.1    Wild, J.M.2
  • 17
    • 79960959388 scopus 로고    scopus 로고
    • Hyperpolarized 129Xe MR imaging with balanced steady-state free precession in spontaneously breathing mouse lungs
    • Imai F, Kashiwagi R, Imai H, Iguchi S, Kimura A, Fujiwara H,. Hyperpolarized 129Xe MR imaging with balanced steady-state free precession in spontaneously breathing mouse lungs. Magn Reson Med Sci 2011; 10: 33-40.
    • (2011) Magn Reson Med Sci , vol.10 , pp. 33-40
    • Imai, F.1    Kashiwagi, R.2    Imai, H.3    Iguchi, S.4    Kimura, A.5    Fujiwara, H.6
  • 22
    • 0031480383 scopus 로고    scopus 로고
    • Spin-exchange optical pumping of noble-gas nuclei
    • Walker TG, Happer W,. Spin-exchange optical pumping of noble-gas nuclei. Rev Mod Phys 1997; 69: 629-642.
    • (1997) Rev Mod Phys , vol.69 , pp. 629-642
    • Walker, T.G.1    Happer, W.2
  • 23
    • 0034956696 scopus 로고    scopus 로고
    • Characterization and reduction of the transient response in steady-state MR imaging
    • Hargreaves BA, Vasanawala SS, Pauly JM, Nishimura DG,. Characterization and reduction of the transient response in steady-state MR imaging. Magn Reson Med 2001; 46: 149-158.
    • (2001) Magn Reson Med , vol.46 , pp. 149-158
    • Hargreaves, B.A.1    Vasanawala, S.S.2    Pauly, J.M.3    Nishimura, D.G.4
  • 24
    • 0025902111 scopus 로고
    • Analytical solution and verification of diffusion effect in SSFP
    • Carney CE, Wong STS, Patz S,. Analytical solution and verification of diffusion effect in SSFP. Magn Reson Med 1991; 19: 240-246.
    • (1991) Magn Reson Med , vol.19 , pp. 240-246
    • Carney, C.E.1    Wong, S.T.S.2    Patz, S.3
  • 28
    • 84932199766 scopus 로고    scopus 로고
    • Dedicated receiver array coil for 1H lung imaging with same-breath acquisition of hyperpolarized 3He and 129Xe gas
    • Rao M, Robb F, Wild JM,. Dedicated receiver array coil for 1H lung imaging with same-breath acquisition of hyperpolarized 3He and 129Xe gas. Magn Reson Med 2015; 74: 291-299.
    • (2015) Magn Reson Med , vol.74 , pp. 291-299
    • Rao, M.1    Robb, F.2    Wild, J.M.3
  • 30
    • 84875051321 scopus 로고    scopus 로고
    • Quantitative analysis of hyperpolarized 129Xe ventilation imaging in healthy volunteers and subjects with chronic obstructive pulmonary disease
    • Virgincar RS, Cleveland ZI, Sivaram Kaushik S, et al., Quantitative analysis of hyperpolarized 129Xe ventilation imaging in healthy volunteers and subjects with chronic obstructive pulmonary disease. NMR Biomed 2013; 26: 424-435.
    • (2013) NMR Biomed , vol.26 , pp. 424-435
    • Virgincar, R.S.1    Cleveland, Z.I.2    Sivaram Kaushik, S.3
  • 31
    • 0001144758 scopus 로고
    • Nuclear spin relaxation by intermolecular magnetic dipole coupling in the gas phase. 129Xe in oxygen
    • Jameson CJ, Jameson AK, Hwang JK,. Nuclear spin relaxation by intermolecular magnetic dipole coupling in the gas phase. 129Xe in oxygen. J Chem Phys 1988; 89: 4074-4081.
    • (1988) J Chem Phys , vol.89 , pp. 4074-4081
    • Jameson, C.J.1    Jameson, A.K.2    Hwang, J.K.3
  • 35
    • 84892806625 scopus 로고    scopus 로고
    • Regional mapping of gas uptake by blood and tissue in the human lung using hyperpolarized xenon-129 MRI
    • Qing K, Ruppert K, Jiang Y, et al., Regional mapping of gas uptake by blood and tissue in the human lung using hyperpolarized xenon-129 MRI. J Magn Reson Imaging 2014; 39: 346-359.
    • (2014) J Magn Reson Imaging , vol.39 , pp. 346-359
    • Qing, K.1    Ruppert, K.2    Jiang, Y.3
  • 38
    • 79151474320 scopus 로고    scopus 로고
    • Interdependence of in-cell xenon density and temperature during Rb/ 129Xe spin-exchange optical pumping using VHG-narrowed laser diode arrays
    • Whiting N, Nikolaou P, Eschmann NA, Goodson BM, Barlow MJ,. Interdependence of in-cell xenon density and temperature during Rb/ 129Xe spin-exchange optical pumping using VHG-narrowed laser diode arrays. J Magn Reson 2011; 208: 298-304.
    • (2011) J Magn Reson , vol.208 , pp. 298-304
    • Whiting, N.1    Nikolaou, P.2    Eschmann, N.A.3    Goodson, B.M.4    Barlow, M.J.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.