Volumn 68, Issue 6, 2012, Pages 1900-1904

Hyperpolarized 129Xe gas lung MRI-SNR and T2 * comparisons at 1.5 T and 3 T

Author keywords

hyperpolarized; magnetic field strength; signal to noise ratio; SNR; xenon

Indexed keywords

BIOLOGICAL ORGANS; BIOMEDICAL SIGNAL PROCESSING; MAGNETIC RESONANCE IMAGING; XENON;

EID: 84870062183     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.24190     Document Type: Article
Times cited : (41)

References (21)
  • 4
    • 12844279813 scopus 로고    scopus 로고
    • Theoretical signal-to-noise ratio and spatial resolution dependence on the magnetic field strength for hyperpolarized noble gas magnetic resonance imaging of human lungs
    • Parra-Robles J, Cross AR, Santyr GE,. Theoretical signal-to-noise ratio and spatial resolution dependence on the magnetic field strength for hyperpolarized noble gas magnetic resonance imaging of human lungs. Med Phys 2005; 32: 221-229.
    • (2005) Med Phys , vol.32 , pp. 221-229
    • Parra-Robles, J.1    Cross, A.R.2    Santyr, G.E.3
  • 5
    • 12144283565 scopus 로고    scopus 로고
    • Hyperpolarized He-3 lung imaging at 0.5 and 1.5 tesla: A study of susceptibility-induced effects
    • Salerno M, Brookeman JR, de Lange EE, Mugler JP,. Hyperpolarized He-3 lung imaging at 0.5 and 1.5 tesla: a study of susceptibility-induced effects. Magn Reson Med 2005; 53: 212-216.
    • (2005) Magn Reson Med , vol.53 , pp. 212-216
    • Salerno, M.1    Brookeman, J.R.2    De Lange, E.E.3    Mugler, J.P.4
  • 10
    • 3442902841 scopus 로고    scopus 로고
    • MRI of the Lung using hyperpolarized 3He at very low magnetic field (3 mT)
    • Bidinosti CP, Choukeife J, Tastevin G, Vignaud A, Nacher PJ,. MRI of the Lung using hyperpolarized 3He at very low magnetic field (3 mT). MAGMA 2004; 16: 255-259.
    • (2004) MAGMA , vol.16 , pp. 255-259
    • Bidinosti, C.P.1    Choukeife, J.2    Tastevin, G.3    Vignaud, A.4    Nacher, P.J.5
  • 11
    • 0036201635 scopus 로고    scopus 로고
    • K-space filtering in 2D gradient-echo breath-hold hyperpolarized He-3 MRI: Spatial resolution and signal-to-noise ratio considerations
    • Wild JM, Paley MNJ, Viallon M, Schreiber WG, van Beek EJR, Griffiths PD,. k-space filtering in 2D gradient-echo breath-hold hyperpolarized He-3 MRI: spatial resolution and signal-to-noise ratio considerations. Magn Reson Med 2002; 47: 687-695.
    • (2002) Magn Reson Med , vol.47 , pp. 687-695
    • Wild, J.M.1    Paley, M.N.J.2    Viallon, M.3    Schreiber, W.G.4    Van Beek, E.J.R.5    Griffiths, P.D.6
  • 12
    • 80054822619 scopus 로고    scopus 로고
    • Signal-to-noise ratio for hyperpolarized (3)He MR imaging of human lungs: A 1.5 T and 3 T comparison
    • Dominguez-Viqueira W, Ouriadov A, O'Halloran R, Fain SB, Santyr GE,. Signal-to-noise ratio for hyperpolarized (3)He MR imaging of human lungs: a 1.5 T and 3 T comparison. Magn Reson Med 2011; 66: 1400-1404.
    • (2011) Magn Reson Med , vol.66 , pp. 1400-1404
    • Dominguez-Viqueira, W.1    Ouriadov, A.2    O'Halloran, R.3    Fain, S.B.4    Santyr, G.E.5
  • 13
    • 0031480383 scopus 로고    scopus 로고
    • Spin-exchange optical pumping of noble-gas nuclei
    • Walker TG, Happer W,. Spin-exchange optical pumping of noble-gas nuclei. RMP 1997; 69: 629-642.
    • (1997) RMP , vol.69 , pp. 629-642
    • Walker, T.G.1    Happer, W.2
  • 14
    • 77957744266 scopus 로고    scopus 로고
    • Enhancement of (129)Xe polarization by off-resonant spin exchange optical pumping
    • Parnell SR, Deppe MH, Parra-Robles J, Wild JM,. Enhancement of (129)Xe polarization by off-resonant spin exchange optical pumping. J Appl Phys 2010; 108: 064908-1-064908-5.
    • (2010) J Appl Phys , vol.108 , pp. 0649081-0649085
    • Parnell, S.R.1    Deppe, M.H.2    Parra-Robles, J.3    Wild, J.M.4
  • 16
    • 4243134903 scopus 로고    scopus 로고
    • Comparison between 2D and 3D gradient-echo sequences for MRI of human lung ventilation with hyperpolarized 3He
    • Wild JM, Woodhouse N, Paley MN, Fichele S, Said Z, Kasuboski L, van Beek EJ,. Comparison between 2D and 3D gradient-echo sequences for MRI of human lung ventilation with hyperpolarized 3He. Magn Reson Med 2004; 52: 673-678.
    • (2004) Magn Reson Med , vol.52 , pp. 673-678
    • Wild, J.M.1    Woodhouse, N.2    Paley, M.N.3    Fichele, S.4    Said, Z.5    Kasuboski, L.6    Van Beek, E.J.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.