메뉴 건너뛰기




Volumn 204, Issue 6, 2015, Pages 1242-1247

Pulmonary nodules with ground-glass opacity can be reliably measured with low-dose techniques regardless of iterative reconstruction: Results of a phantom study

Author keywords

Ground glass opacity; Lung cancer; Pulmonary nodule; Quantitative imaging; Volume measurement

Indexed keywords

ALGORITHM; ARTICLE; COMPUTER ASSISTED TOMOGRAPHY; CONTROLLED STUDY; DIMENSIONAL MEASUREMENT ACCURACY; IMAGE ANALYSIS; IMAGE ENHANCEMENT; IMAGE RECONSTRUCTION; IMAGING PHANTOM; LUNG NODULE; MATHEMATICAL ANALYSIS; MEASUREMENT PRECISION; PRIORITY JOURNAL; RADIATION DOSE; RELIABILITY; COMPARATIVE STUDY; COMPUTER ASSISTED DIAGNOSIS; DEVICES; HUMAN; IMAGE QUALITY; LUNG TUMOR; PROCEDURES; RADIATION PROTECTION; RADIOGRAPHY; REPRODUCIBILITY; SENSITIVITY AND SPECIFICITY;

EID: 84937701179     PISSN: 0361803X     EISSN: 15463141     Source Type: Journal    
DOI: 10.2214/AJR.14.13820     Document Type: Article
Times cited : (25)

References (27)
  • 1
    • 64949119251 scopus 로고    scopus 로고
    • Non-calcified lung nodules: Volumetric assessment with thoracic CT
    • Gavrielides MA, Kinnard LM, Myers KJ, Petrick N. Non-calcified lung nodules: volumetric assessment with thoracic CT. Radiology 2009; 251:26-37
    • (2009) Radiology , vol.251 , pp. 26-37
    • Gavrielides, M.A.1    Kinnard, L.M.2    Myers, K.J.3    Petrick, N.4
  • 2
    • 77956126688 scopus 로고    scopus 로고
    • Change in lung tumor volume as a biomarker of treatment response: A critical review of the evidence
    • Mozley PD, Schwartz LH, Bendtsen C, et al. Change in lung tumor volume as a biomarker of treatment response: a critical review of the evidence. Ann Oncol 2010; 21:1751-1755
    • (2010) Ann Oncol , vol.21 , pp. 1751-1755
    • Mozley, P.D.1    Schwartz, L.H.2    Bendtsen, C.3
  • 3
    • 40949159721 scopus 로고    scopus 로고
    • Fleischner society: Glossary of terms for thoracic imaging
    • Hansell DM, Bankier AA, MacMahon H, et al. Fleischner society: glossary of terms for thoracic imaging. Radiology 2008; 246:697-722
    • (2008) Radiology , vol.246 , pp. 697-722
    • Hansell, D.M.1    Bankier, A.A.2    MacMahon, H.3
  • 4
    • 0036109223 scopus 로고    scopus 로고
    • CT screening for lung cancer: Frequency and significance of part-solid and nonsolid nodules
    • Henschke CI, Yankelevitz DF, Mirtcheva R, et al. CT screening for lung cancer: frequency and significance of part-solid and nonsolid nodules. AJR 2002; 178:1053-1057
    • (2002) AJR , vol.178 , pp. 1053-1057
    • Henschke, C.I.1    Yankelevitz, D.F.2    Mirtcheva, R.3
  • 5
    • 79551563284 scopus 로고    scopus 로고
    • IASLC/ATS/ERS international multidisciplinary classification of lung adenocarcinoma
    • Travis WD, Brambilla E, Noguchi M, et al. IASLC/ATS/ERS international multidisciplinary classification of lung adenocarcinoma. J Thorac Oncol 2011; 6:244-285
    • (2011) J Thorac Oncol , vol.6 , pp. 244-285
    • Travis, W.D.1    Brambilla, E.2    Noguchi, M.3
  • 6
    • 84890559761 scopus 로고    scopus 로고
    • Tumor invasiveness as defined by the newly proposed IASLC/ATS/ERS classification has prognostic significance for pathologic stage IA lung adenocarcinoma and can be predicted by radiologic parameters
    • Takahashi M, Shigematsu Y, Ohta M, et al. Tumor invasiveness as defined by the newly proposed IASLC/ATS/ERS classification has prognostic significance for pathologic stage IA lung adenocarcinoma and can be predicted by radiologic parameters. J Thorac Cardiovasc Surg 2014; 147:54-59
    • (2014) J Thorac Cardiovasc Surg , vol.147 , pp. 54-59
    • Takahashi, M.1    Shigematsu, Y.2    Ohta, M.3
  • 7
    • 84871689360 scopus 로고    scopus 로고
    • Recommendations for the management of subsolid pulmonary nodules detected at CT: A statement from the Fleischner Society
    • Naidich DP, Bankier AA, MacMahon H, et al. Recommendations for the management of subsolid pulmonary nodules detected at CT: a statement from the Fleischner Society. Radiology 2013; 266:304-317
    • (2013) Radiology , vol.266 , pp. 304-317
    • Naidich, D.P.1    Bankier, A.A.2    MacMahon, H.3
  • 8
    • 62649137035 scopus 로고    scopus 로고
    • A comparison of six software packages for evaluation of solid lung nodules using semi-automated volumetry: What is the minimum increase in size to detect growth in repeated CT examinations?
    • de Hoop B, Gietema H, van Ginneken B, et al. A comparison of six software packages for evaluation of solid lung nodules using semi-automated volumetry: what is the minimum increase in size to detect growth in repeated CT examinations? Eur Radiol 2009; 19:800-808
    • (2009) Eur Radiol , vol.19 , pp. 800-808
    • De Hoop, B.1    Gietema, H.2    Van Ginneken, B.3
  • 9
    • 77950427436 scopus 로고    scopus 로고
    • Pulmonary ground-glass nodules: Increase in mass as an early indicator of growth
    • de Hoop B, Gietema H, van de Vorst S, et al. Pulmonary ground-glass nodules: increase in mass as an early indicator of growth. Radiology 2010; 255:199-206
    • (2010) Radiology , vol.255 , pp. 199-206
    • De Hoop, B.1    Gietema, H.2    Van De Vorst, S.3
  • 10
    • 80655139859 scopus 로고    scopus 로고
    • Lung cancer screening with low-dose helical CT: Results from the National Lung Screening Trial (NLST)
    • Kramer BS, Berg CD, Aberle DR, Prorok PC. Lung cancer screening with low-dose helical CT: results from the National Lung Screening Trial (NLST). J Med Screen 2011; 18:109-111
    • (2011) J Med Screen , vol.18 , pp. 109-111
    • Kramer, B.S.1    Berg, C.D.2    Aberle, D.R.3    Prorok, P.C.4
  • 12
    • 79851512500 scopus 로고    scopus 로고
    • Assessment of lung-cancer mortality reduction from CT screening
    • Henschke CI, Boffetta P, Gorlova O, et al. Assessment of lung-cancer mortality reduction from CT screening. Lung Cancer 2011; 71:328-332
    • (2011) Lung Cancer , vol.71 , pp. 328-332
    • Henschke, C.I.1    Boffetta, P.2    Gorlova, O.3
  • 13
    • 80054952663 scopus 로고    scopus 로고
    • Estimated radiation dose associated with low-dose chest CT of average-size participants in the National Lung Screening Trial
    • Larke FJ, Kruger RL, Cagnon CH, et al. Estimated radiation dose associated with low-dose chest CT of average-size participants in the National Lung Screening Trial. AJR 2011; 197:1165-1169
    • (2011) AJR , vol.197 , pp. 1165-1169
    • Larke, F.J.1    Kruger, R.L.2    Cagnon, C.H.3
  • 14
    • 84907481886 scopus 로고    scopus 로고
    • Accuracy of lung nodule volumetry in low-dose CT with iterative reconstruction: An anthropomorphic thoracic phantom study
    • Doo KW, Kang EY, Yong HS, et al. Accuracy of lung nodule volumetry in low-dose CT with iterative reconstruction: an anthropomorphic thoracic phantom study. Br J Radiol 2014; 87:20130644
    • (2014) Br J Radiol , vol.87 , pp. 20130644
    • Doo, K.W.1    Kang, E.Y.2    Yong, H.S.3
  • 15
    • 67649786646 scopus 로고    scopus 로고
    • Volumetric measurement pulmonary ground-glass opacity nodules with multi-detector CT: Effect of various tube current on measurement accuracy-A chest CT phantom study
    • Linning E, Daqing M. Volumetric measurement pulmonary ground-glass opacity nodules with multi-detector CT: effect of various tube current on measurement accuracy-a chest CT phantom study. Acad Radiol 2009; 16:934-939
    • (2009) Acad Radiol , vol.16 , pp. 934-939
    • Linning, E.1    Daqing, M.2
  • 16
    • 76149092829 scopus 로고    scopus 로고
    • Computer-aided volumetry of pulmonary nodules exhibiting groundglass opacity at MDCT
    • Oda S, Awai K, Murao K, et al. Computer-aided volumetry of pulmonary nodules exhibiting groundglass opacity at MDCT. AJR 2010; 194:398-406
    • (2010) AJR , vol.194 , pp. 398-406
    • Oda, S.1    Awai, K.2    Murao, K.3
  • 17
    • 84889633438 scopus 로고    scopus 로고
    • Volumetric quantification of lung nodules in CT with iterative reconstruction (ASiR and MBIR)
    • Chen B, Barnhart H, Richard S, et al. Volumetric quantification of lung nodules in CT with iterative reconstruction (ASiR and MBIR). Med Phys 2013; 40:111902
    • (2013) Med Phys , vol.40 , pp. 111902
    • Chen, B.1    Barnhart, H.2    Richard, S.3
  • 18
    • 84870947386 scopus 로고    scopus 로고
    • Systematic error in lung nodule volumetry: Effect of iterative reconstruction versus filtered back projection at different CT parameters
    • Willemink MJ, Leiner T, Budde RP, et al. Systematic error in lung nodule volumetry: effect of iterative reconstruction versus filtered back projection at different CT parameters. AJR 2012; 199:1241-1246
    • (2012) AJR , vol.199 , pp. 1241-1246
    • Willemink, M.J.1    Leiner, T.2    Budde, R.P.3
  • 19
    • 84886952447 scopus 로고    scopus 로고
    • A resource for the assessment of lung nodule size estimation methods: Database of thoracic CT scans of an anthropomorphic phantom
    • Gavrielides MA, Kinnard LM, Myers KJ, et al. A resource for the assessment of lung nodule size estimation methods: database of thoracic CT scans of an anthropomorphic phantom. Opt Express 2010; 18:15244-15255
    • (2010) Opt Express , vol.18 , pp. 15244-15255
    • Gavrielides, M.A.1    Kinnard, L.M.2    Myers, K.J.3
  • 20
    • 80051517687 scopus 로고    scopus 로고
    • Combination of a low tube voltage technique with the hybrid iterative reconstruction (iDose) algorithm at coronary CT angiography
    • Funama Y, Taguchi K, Utsunomiya D, et al. Combination of a low tube voltage technique with the hybrid iterative reconstruction (iDose) algorithm at coronary CT angiography. J Comput Assist Tomogr 2011; 35:480-485
    • (2011) J Comput Assist Tomogr , vol.35 , pp. 480-485
    • Funama, Y.1    Taguchi, K.2    Utsunomiya, D.3
  • 21
    • 77957585579 scopus 로고    scopus 로고
    • Information-theoretic approach for analyzing bias and variance in lung nodule size estimation
    • Gavrielides MA, Zeng R, Kinnard LM, Myers KJ, Petrick N. Information-theoretic approach for analyzing bias and variance in lung nodule size estimation. IEEE Trans Med Imaging 2010; 29:1795-1807
    • (2010) IEEE Trans Med Imaging , vol.29 , pp. 1795-1807
    • Gavrielides, M.A.1    Zeng, R.2    Kinnard, L.M.3    Myers, K.J.4    Petrick, N.5
  • 22
    • 66649123262 scopus 로고    scopus 로고
    • Imprecision in automated volume measurements of pulmonary nodules and its effect on the level of uncertainty in volume doubling time estimation
    • Nietert PJ, Ravenel JG, Leue WM, et al. Imprecision in automated volume measurements of pulmonary nodules and its effect on the level of uncertainty in volume doubling time estimation. Chest 2009; 135:1580-1587
    • (2009) Chest , vol.135 , pp. 1580-1587
    • Nietert, P.J.1    Ravenel, J.G.2    Leue, W.M.3
  • 23
    • 84857587615 scopus 로고    scopus 로고
    • Quantitative CT: Technique dependence of volume estimation on pulmonary nodules
    • Chen B, Barnhart H, Richard S, et al. Quantitative CT: technique dependence of volume estimation on pulmonary nodules. Phys Med Biol 2012; 57:1335-1348
    • (2012) Phys Med Biol , vol.57 , pp. 1335-1348
    • Chen, B.1    Barnhart, H.2    Richard, S.3
  • 24
    • 0034594628 scopus 로고    scopus 로고
    • New guidelines to evaluate the response to treatment in solid tumors
    • Therasse P, Arbuck SG, Eisenhauer EA, et al. New guidelines to evaluate the response to treatment in solid tumors. J Natl Cancer Inst 2000; 92:205-216
    • (2000) J Natl Cancer Inst , vol.92 , pp. 205-216
    • Therasse, P.1    Arbuck, S.G.2    Eisenhauer, E.A.3
  • 25
    • 57849117384 scopus 로고    scopus 로고
    • New response evaluation criteria in solid tumours: Revised RECIST guideline (version 1.1)
    • Eisenhauer EA, Therasse P, Bogaerts J, et al. New response evaluation criteria in solid tumours: revised RECIST guideline (version 1.1). Eur J Cancer 2009; 45:228-247
    • (2009) Eur J Cancer , vol.45 , pp. 228-247
    • Eisenhauer, E.A.1    Therasse, P.2    Bogaerts, J.3
  • 26
    • 84873526859 scopus 로고    scopus 로고
    • Benefit of overlapping reconstruction for improving the quantitative assessment of CT lung nodule volume
    • Gavrielides MA, Zeng R, Myers KJ, Sahiner B, Petrick N. Benefit of overlapping reconstruction for improving the quantitative assessment of CT lung nodule volume. Acad Radiol 2013; 20:173-180
    • (2013) Acad Radiol , vol.20 , pp. 173-180
    • Gavrielides, M.A.1    Zeng, R.2    Myers, K.J.3    Sahiner, B.4    Petrick, N.5
  • 27
    • 75749133314 scopus 로고    scopus 로고
    • Variability of semiautomated lung nodule volumetry on ultralowdose CT: Comparison with nodule volumetry on standard-dose CT
    • Hein PA, Romano VC, Rogalla P, et al. Variability of semiautomated lung nodule volumetry on ultralowdose CT: comparison with nodule volumetry on standard-dose CT. J Digit Imaging 2010; 23:8-17
    • (2010) J Digit Imaging , vol.23 , pp. 8-17
    • Hein, P.A.1    Romano, V.C.2    Rogalla, P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.